Multi-Constituent Airborne Contaminants Capture with Low Cost Oxide Getters and Mitigation of Cathode Poisoning in Solid Oxide Fuel Cell

The technical effort and scientific findings, discussed in this report, documents operational barriers and associated long term performance stability challenges posed by the presence of trace airborne multi-constituent contaminants present in high-temperature electrochemical systems, including Solid Oxide Fuel Cells (SOFCs), Solid Oxide Electrolysis Cells (SOECs), Ion Transport Membranes, and Gas Separation systems. Above systems, offering promises for cleanliness and energy efficiency, face challenges with electrode poisoning stemming from the presence of trace contaminants including gaseous Cr/B/Si vapors in the presence of intrinsic contaminants SO 2 /CO 2 /H 2 O gases. The study indicates that the long-term electrical performance degradation in SOFC systems can be traced to electrochemical, structural, and mechanical changes across cell, stack, and balance of plant components resulting from interactions with trace contaminants leading to increase in both ohmic and non-ohmic polarizations. The degradation primarily results from solid-state and gas-phase materials migration, electrode poisoning, and interactions at the cell and stack levels. Cathode degradation emerges as a significant factor impacting overall SOFC performance, especially related to the presence of intrinsic and extrinsic airborne impurities such as SOx, CrOx(OH)y, SOx, Si(OH)x, and HBOx. Although at trace levels, prolong systems operation at higher airflow (3-10X stoichiometric) allow the accumulation of contaminants within the cell components leading to electrical performance degradation through poisoning and electrode deactivation.

20 FOSSIL-FUELED POWER PLANTS↗

Performance Demonstration of an Occupancy Sensor-enabled Integrated Solution for Commercial Buildings

Traditionally, a single-loop fixed-gain controller is applied to supply fan (SF) and cooling coil (CC) valve controls while a fixed-damper position control is applied to outdoor air (OA) damper control at air handling units (AHUs) in commercial buildings. With the increasing application of occupancy sensors, the information generated by occupancy sensors is applied to not only reduce the electricity loads from lighting and controllable plug loads, but also reset OA intake and minimum supply airflow setpoints. Meanwhile, these intermittent operation actions greatly elevate the dynamics of AHU systems, which may introduce unstable SF and CC valve operations and inaccurate OA flow control at AHUs and consequently degrade maximum energy efficiency gains. With virtual fan and valve flow meter technologies, two advanced controls, including cascade control and gain scheduling control, can be implemented on both the SF and CC valve, and an advanced control using a virtual OA flow meter can be implemented on OA damper integrated with occupancy sensors. The goal of this project is to demonstrate the savings, cost, and performance of an integrated solution that integrates the three advanced HVAC controls with occupancy sensors to allow accurate and stable AHU operations in real buildings. The project objectives are to: 1) develop and validate an advance SF control algorithm; 2) develop and validate an advanced CC valve control algorithm; 3) validate an algorithm to implement a virtual OA flow meter; and 4) demonstrate the savings, cost, and performance of the integrated solution in real buildings. The technical approaches are to: 1) select a test system at the University of Oklahoma; 2) develop and implement the algorithms of advanced SF and CC valve controls and validate the performance; 3) develop and implement the advanced OA control using a virtual OA flow meter and validate the performance; 4) demonstrate the savings, cost, and performance of the proposed integrated solution with and without three advanced HVAC controls; and 5) disseminate the project results through publications and presentations. For the SF control, both the gain scheduling and cascade controls can improve the fan energy performance by reducing the fan power during the transient period and the fan control performance at lower speeds by reducing fan speed variation. Moreover, the gain scheduling control provides a simple and low-cost solution and is recommended. The fan power savings can reach 30% in a transient period. For the CC valve control, the gain scheduling control can considerably reduce the supply air temperature oscillation range and frequency under both higher and lower load conditions and the control valve response is much more stable. As a result, the gain scheduling control is recommended. The projected pump energy consumption can be reduced by 68.5%. With the developed virtual OA flow meter, the OA can be accurately controlled at its setpoint, which is determined based on the actual number of occupants in the building provided by occupancy sensors. The RMSE of the proposed OA control is 15.9 L/s. The energy data shows that the fan power and CC cooling energy were significantly reduced. On the other hand, the energy savings majorly results from the occupancy sensors and the energy savings by the advanced HVAC controls is minimal because that the controllers in the test AHU were tuned with very slow response. An annual technical savings potential is estimated as 0.5 quads in the commercial sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

IoT-Based Comfort Control and Fault Diagnostics System for Energy-Efficient Homes

This project studies an Internet of Things (IoT)-based comfort control and fault diagnostics system (referred as iComfort in this report) for energy-efficient homes. The system delivers an occupant-comfort-oriented thermal environment adaptive to fault scenarios and achieves HVAC energy savings in a cost-effective and straightforward way. This smart iComfort home system consists of the following key features. 1) Cost-effectiveness and scalability of the entire hardware and software system: The system includes low-cost temperature, humidity, and airflow sensors, and a Raspberry Pi-based local hub that interfaces with the cloud and IoT-enabled devices. The cost is low, not only for sensors, but also the costs associated with sensor installation, system setup and commissioning, data communication and storage, and data analytics (e.g., the development of automated fault detection and diagnosis (AFDD), as well as adaptive control strategies that are both computationally efficient and practical to implement). 2) Energy performance and user satisfaction: The system delivers user satisfaction and energy savings. This includes a) ease of use, b) optimal occupant thermal comfort, and c) accurate system feedback (e.g., low false alarm of AFDD strategies). 3) Favorable demonstrated prototype performance: The prototype tested at the Pacific Northwest National Laboratory (PNNL) Lab Homes demonstrates the accuracy of fault detections and diagnoses and shows thermal comfort improvement and energy savings through adaptive and optimal HVAC operations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential HVAC Fault Data Collection Plan – Refrigerant Undercharge and Overcharge Faults

Heating, ventilation, and air-conditioning (HVAC) systems can develop faults due to poor installation practices or gradual wear and tear, leading to decreased HVAC system’s efficiency, compromised thermal comfort, and shortened equipment lifespan (EERE, 2018). Automated fault detection and diagnosis (AFDD) technologies offer a solution by identifying energy-wasting HVAC faults, such as inadequate indoor airflow and incorrect refrigerant charge, and guiding technicians to enhance system efficiency. In the realm of residential HVAC, AFDD can be implemented through various fault detection and diagnosis capabilities, sensor configurations, and target applications. These technologies typically fall into three categories: smart diagnostic tools, original equipment manufacturer (OEM)-embedded tools, and add-on tools. Smart diagnostic tools employ temporarily installed sensors to directly measure HVAC system characteristics, while OEM-embedded tools utilize factory-installed sensors to identify faults or assess system performance. However, both these types of AFDD technologies are often only accessible for high-end HVAC equipment or require additional sensor installation by qualified technicians, resulting in high investment costs and limited applicability for low-income residential buildings. On the other hand, add-on tools rely solely on data from smart thermostats and meters to detect faults by continuously analyzing equipment runtime or energy usage. As smart thermostat and meter costs decrease and their prevalence increases, these tools can be readily deployed in low-income residential buildings. However, they possess limited capabilities as they rely solely on basic trend analysis. Enhancing such tools with advanced machine learning algorithms can significantly improve their effectiveness.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and Validation of Home Comfort System for Total Performance Deficiency/Fault Detection and Optimal Comfort Control

In this project, we developed and tested a learning-based home thermal model that facilitates the operation of a model predictive control (MPC)-based optimization agent and an automated fault detection and diagnosis (AFDD) agent. The home thermal model was constructed using a two-node resistor-capacitor model. Moreover, two accompanying parameter identification methods were introduced, least-squares and optimization. Based on the home thermal model, the MPC-based optimization agent was developed to optimize residential HVAC operation. Using two FDD methods, the AFDD agent was constructed to detect and diagnose two prevalent residential AC faults, airflow reduction and refrigerant undercharge. The home thermal model, along with the MPC-based optimization agent and AFDD agent, were tested at the Norman Test House, Miami Test House, Pacific Northwest National Laboratory (PNNL) Test House A, and PNNL Test House B. Finally, they were also field tested in nine demonstration homes with real occupants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multiphysics Simulations of Thermal Shock Testing of Nanofibrous High Power Targets

Increase of primary beam power for neutrino beam-lines leads to a reduced lifespan for production targets. The field of High Power Targetry (HPT) is generating new concepts to meet the need for robust targets. One idea being investigated by the HPT Research and Development Group at Fermilab is an electrospun nanofiber target. As part of their evaluation, samples with different densities were sent to the HiRadMat facility at CERN for thermal shock tests. The samples with the higher density, irradiated under a high intensity beam pulse, exhibit major damages at the impact site whereas those with the lower density show no apparent damages. The exact cause of this failure was unclear at the time. In this paper, we present the results of multiphysics simulations of the thermal shock experienced by the nanofiber targets that suggest the failure originates from the reduced permeability of the high density sample to airflow. The air present in the porous target expands due to heating from the beam, but is unable to flow freely in the high density sample, resulting in a larger back pressure that blows apart the mat. We close with a discussion on how to further validate this hypothesis.

43 PARTICLE ACCELERATORS↗

Cyber-Physical Simulation of the Cold Startup of Solid Oxide Fuel Cell – Gas Turbine (SOFC-GT) Hybrid Systems

This work introduces experimental studies for the cold startup process (CPS) of the SOFC-GT hybrid system using the cyber-physical simulation approach. The physical gas turbine is coupled with a cyber-physical SOFC stack, which is represented using the integration of a real time dynamic SOFC model with physical components (e.g., pressure chamber, natural gas burner, etc.). Different ramp rates of the turbine speed were tested out during the startup processes. Bypass valves were also used to manipulate the airflow during SOFC-GT hybrid system start-up process. Different ramp rates enable the rapid start-up of the turbine to avoid surge and stall, meanwhile enable acceptable warm rate of the fuel cell stack without damaging the cell material. CPS can enable dynamic characterizations of highly integrated systems at lower cost.

Zhou, Nana↗

Assembling the SSR2 Cavities String for PIP-II

Characterization of the interaction between airflow and a superconducting radio frequency cavity for particle accelerators in an ultra-clean environment

Tamburrino, Alessandro [Pisa U.]↗

Design, Fabrication and On-Sun Performance Evaluation of SiC Receiver Feature Specimens for CST Applications Using Additively Manufactured SiC Materials

Increasing operating temperatures of solar receivers is paramount to the efficiency of concentrated solar thermal (CST) and solar power (CSP) systems. Successful development of CST systems to generate heat for industrial applications requires significant increase in temperature capability and techno-economically viability of the receiver systems. Supported by an award from the Solar Technology Office (SETO), US Department of Energy (DOE), GE Aerospace Research in collaboration with Heliogen Holdings Inc and Sandia National Lab, is engaged in the development of ultra-High Operating Temperature SiC-matrix Solar Thermal Air Receiver (HOTSSTAR) enabled by additive manufacturing. The program objective is to demonstrate SiC receiver with air exit temperatures up to 1100 oC and high thermal efficiencies. We report design, fabrication and on-sun test results of SiC components of a prototype 50kW (thermal) HOTSSTAR module. The receiver module architecture is based on a radial airflow design and consists of a series of radial SiC receiver sectors organized around a SiC center absorber. The SiC components are fabricated using binder-jet printed SiC followed by melt-infiltration reaction bonding process. To enhance the reliability and to minimize the risk of cracking damage of SiC test articles in thermal gradient and thermal shock environment of the application, the components were laminated with GE’s MI SiC-SiC CMC. Following extensive design and lab test analyses, selected SiC component designs are tested at Heliogen Lancaster Solar field under highly concentrated solar fluxes around 2000 suns to assess the thermal performance characteristics under realistic field conditions. We report on the test results and compare the thermal performances of different HOTSSTAR SiC absorbers. Finally, we discuss fabrication and initial assembly of a 50kW prototype test module in preparation of on-sun field tests to assess the performance of our final design.

CST, CSP, high temperature, air receiver, SiC, add↗

Performance Evaluation of an Additively Manufactured ultra-High Operating Temperature SiC Solar-Thermal Air Receiver (HOTSSTAR) Test Module

Increasing operating temperatures of solar receivers is paramount to the efficiency of concentrated solar thermal and solar power systems. GE Aerospace Research in collaboration with Heliogen Inc and Sandia National Laboratories (SNL) is engaged in the development of ultra-High Operating Temperature SiC-matrix Solar Thermal Air Receiver (HOTSSTAR) enabled by additive manufacturing. HOTSSTAR goal is to demonstrate SiC receiver with air exit temperatures up to 1100oC. We discuss fabrication and on-sun test results of a prototype 50kWth test module. The receiver architecture is based on a radial airflow design and consists of a series of radial SiC receiver sectors organized around central absorber. These components were fabricated using binder-jet printed SiC followed by melt-infiltration reaction bonding process. To enhance the thermo-mechanical reliability of SiC test articles in thermal gradient/ shock environment of the application, the components were laminated with GE’s MI SiC CMC. A dedicated test facility was constructed at SNL Solar Tower to evaluate the operational performance of HOTSSTAR module under solar fluxes >200 W/cm2. We report on our final 50kW test module fabrication, integration at the test facility at Sandia, and discuss on-sun test results. We compare the performance of HOTSSTAR module relative to our model predictions.

14 SOLAR ENERGY↗

Thermal Management Solution for an Integrated Outer-Rotor Motor Drive: Opportunities and Challenges

This work highlights an integrated thermal management solution for the outer-rotor motor (ORM) drive. The integrated ORM drive utilizes water-ethylene glycol coolant for power electronics and stator cooling. Air cooling is used for rotor laminations, magnets and outer-rotor structures, and the rotor shaft. To fully understand the performance of the integrated ORM drive and thermal management coupling effects, a full drive conjugate heat transfer model has been developed to investigate coupled cooling performance of various components of the ORM drive. Various motor rotational speeds, power output scenarios, and cooling options for the integrated ORM drive have been investigated. The model estimates the operating window for the ORM drive while keeping component operating temperatures below prescribed limits. The model also highlights the importance of windage losses at higher rotational speeds for this ORM design, which involves higher rotor surface area per unit width of the rotor. Different designs are also investigated, particularly focusing on rotor cooling with air either naturally induced by rotor spin or forced airflow with the help of a blower, to circumvent challenges imposed by higher windage losses. The work highlights motor rotational speed limitations and the need for potential liquid cooling options for desired rotor performance at higher rotational speeds. Liquid cooling for the rotor may even become more critical for nonuniform rotor-stator gaps, leading to even higher and uneven windage losses across the full circumference of the motor, consequentially, more heating for the rotor.

30 DIRECT ENERGY CONVERSION↗

A Field and Laboratory Study to Characterize Fault Prevalence in Residential Comfort Systems

This report describes a project whose goal was to determine the prevalence of residential comfort system faults. The focus is on air conditioners and heat pumps, and on key faults that can occur during installation and have significant impacts on performance: (1) incorrect refrigerant charge level (undercharge or overcharge); (2) indoor coil airflow rate; (3) liquid line restrictions; (4) non-condensable gas in the refrigerant; and (5) duct leakage. In addition to quantifying fault prevalence, we collected metadata that could be studied to determine whether there are correlations that suggest drivers of fault prevalence, such as regional variations in practice, economic factors, climatic impacts, and others.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mechanical Ventilation and Indoor Air Quality in Recently Constructed U.S. Homes in Marine and Cold-Dry Climates Data from Building America Project

Data were collected to characterize whole-house mechanical ventilation (WHMV) and indoor air quality (IAQ) in 55 homes in the Marine climate of Oregon and Cold-Dry climate of Colorado in the U.S. Sixteen homes were monitored for two weeks, with and without WHMV operating. Ventilation airflows; airtightness; time-resolved CO2, PM2.5 and radon; and time-integrated NO2, NOX and formaldehyde were measured. Participants provided information about IAQ-impacting activities, perceptions and ventilation use. All homes had operational cooktop ventilation and bathroom exhaust. Thirty homes had equipment that could meet the ASHRAE 62.2-2010 standard with continuous or controlled runtime and 34 had some WHMV operating as found. Thirty-five of 46 participants with WHMV reported they did not know how to operate it, and only half of the systems were properly labeled. Two-week homes had lower formaldehyde, radon, CO2, and NO (NOX-NO2) when operated with WHMV; and also had faster PM2.5 decays following indoor emission events. Overall IAQ satisfaction was similar in Oregon and Colorado, but more Colorado participants (19 vs. 3%) felt their IAQ could be improved and more reported dryness as a problem (58 vs. 14%). The collected data indicate that there are benefits of operating WHMV, even when continuous use may not be needed because outdoor pollutant concentrations are low and indoor sources do not present substantial challenges.

air quality↗

Biofilm mitigation in hybrid chemical-biological upcycling of waste polymers

Accumulation of plastic waste in the environment is a serious global issue. To deal with this, there is a need for improved and more efficient methods for plastic waste recycling. One approach is to depolymerize plastic using pyrolysis or chemical deconstruction followed by microbial-upcycling of the monomers into more valuable products. Microbial consortia may be able to increase stability in response to process perturbations and adapt to diverse carbon sources, but may be more likely to form biofilms that foul process equipment, increasing the challenge of harvesting the cell biomass. To better understand the relationship between bioprocess conditions, biofilm formation, and ecology within the bioreactor, in this study a previously-enriched microbial consortium (LS1_Calumet) was grown on (1) ammonium hydroxide-depolymerized polyethylene terephthalate (PET) monomers and (2) the pyrolysis products of polyethylene (PE) and polypropylene (PP). Bioreactor temperature, pH, agitation speed, and aeration were varied to determine the conditions that led to the highest production of planktonic biomass and minimal formation of biofilm. The community makeup and diversity in the planktonic and biofilm states were evaluated using 16S rRNA gene amplicon sequencing. Results showed that there was very little microbial growth on the liquid product from pyrolysis under all fermentation conditions. When grown on the chemically-deconstructed PET the highest cell density (0.69 g/L) with minimal biofilm formation was produced at 30°C, pH 7, 100 rpm agitation, and 10 sL/hr airflow. Results from 16S rRNAsequencing showed that the planktonic phase had higher observed diversity than the biofilm, and that Rhodococcus, Paracoccus, and Chelatococcus were the most abundant genera for all process conditions. Biofilm formation by Rhodococcus sp. And Paracoccus sp. Isolates was typically lower than the full microbial community and varied based on the carbon source. Ultimately, the results indicate that biofilm formation within the bioreactor can be significantly reduced by optimizing process conditions and using pure cultures or a less diverse community, while maintaining high biomass productivity. The results of this study provide insight into methods for upcycling plastic waste and how process conditions can be used to control the formation of biofilm in bioreactors.

36 MATERIALS SCIENCE↗

Development of Advanced Smart Ventilation Controls for Residential Applications

This study examined the use of zoned ventilation systems using a coupled CONTAM/EnergyPlus model for new California dwellings. Several smart control strategies were developed with a target of halving ventilation-related energy use, largely through reducing dwelling ventilation rates based on zone occupancy. The controls were evaluated based on the annual energy consumption relative to continuously operating non-zoned, code-compliant mechanical ventilation systems. The systems were also evaluated from an indoor air quality perspective using the equivalency approach, where the annual personal concentration of a contaminant for a control strategy is compared to the personal concentration that would have occurred using a continuously operating, non-zoned system. Individual occupant personal concentrations were calculated for the following contaminants of concern: moisture, CO2, particles, and a generic contaminant. Zonal controls that saved energy by reducing outside airflow achieved typical reductions in ventilation-related energy of 10% to 30%, compared to the 7% savings from the unzoned control. However, this was at the expense of increased personal concentrations for some contaminants in most cases. In addition, care is required in the design and evaluation of zonal controls, because control strategies may reduce exposure to some contaminants, while increasing exposure to others.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Arctic observations and numerical simulations of surface wind effects on Multi-Angle Snowflake Camera measurements

Abstract. Ground-based measurements of frozen precipitation are heavily influenced by interactions of surface winds with gauge-shield geometry. The Multi-Angle Snowflake Camera (MASC), which photographs hydrometeors in free-fall from three different angles while simultaneously measuring their fall speed, has been used in the field at multiple midlatitude and polar locations both with and without wind shielding. Here, we present an analysis of Arctic field observations – with and without a Belfort double Alter shield – and compare the results to computational fluid dynamics (CFD) simulations of the airflow and corresponding particle trajectories around the unshielded MASC. MASC-measured fall speeds compare well with Ka-band Atmospheric Radiation Measurement (ARM) Zenith Radar (KAZR) mean Doppler velocities only when winds are light (≤5ms-1) and the MASC is shielded. MASC-measured fall speeds that do not match KAZR-measured velocities tend to fall below a threshold value that increases approximately linearly with wind speed but is generally <0.5ms-1. For those events with wind speeds ≤1.5ms-1, hydrometeors fall with an orientation angle mode of 12∘ from the horizontal plane, and large, low-density aggregates are as much as 5 times more likely to be observed. Simulations in the absence of a wind shield show a separation of flow at the upstream side of the instrument, with an upward velocity component just above the aperture, which decreases the mean particle fall speed by 55 % (74 %) for a wind speed of 5 m s−1 (10 m s−1). We conclude that accurate MASC observations of the microphysical, orientation, and fall speed characteristics of snow particles require shielding by a double wind fence and restriction of analysis to events where winds are light (≤5ms-1). Hydrometeors do not generally fall in still air, so adjustments to these properties' distributions within natural turbulence remain to be determined.

54 ENVIRONMENTAL SCIENCES↗

University of Nebraska unmanned aerial system (UAS) profiling during the LAPSE-RATE field campaign

Abstract. This paper describes the data collected by the University of Nebraska-Lincoln (UNL) as part of the field deployments during the Lower Atmospheric Process Studies at Elevation – a Remotely-piloted Aircraft Team Experiment (LAPSE-RATE) flight campaign in July 2018. The UNL deployed two multirotor unmanned aerial systems (UASs) at multiple sites in the San Luis Valley (Colorado, USA) for data collection to support three science missions: convection initiation, boundary layer transition, and cold air drainage flow. We conducted 172 flights resulting in over 21 h of cumulative flight time. Our novel design for the sensor housing onboard the UAS was employed in these flights to meet the aspiration and shielding requirements of the temperature and humidity sensors and to separate them from the mixed turbulent airflow from the propellers. Data presented in this paper include timestamped temperature and humidity data collected from the sensors, along with the three-dimensional position and velocity of the UAS. Data are quality-controlled and time-synchronized using a zero-order-hold interpolation without additional post-processing. The full dataset is also made available for download at https://doi.org/10.5281/zenodo.4306086 (Islam et al., 2020).

Islam, Ashraful (ORCID:000000022826269X)↗