Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “3D image processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Technical Note: Unsupervised C-arm pose tracking with radiographic fiducial

Purpose: C-arm fluoroscopy reconstruction, such as that used in prostate brachytherapy, requires that the relative poses of the individual C-arm fluoroscopy images must be known prior to reconstruction. Radiographic fiducials can provide excellent C-arm pose tracking, but they need to be segmented in the image. The authors report an automated and unsupervised method that does not require prior segmentation of the fiducial. Methods: The authors compute the individual C-arm poses relative to a stationary radiographic fiducial of known geometry. The authors register a filtered 2D fluoroscopy image of the fiducial to its 3D model by using image intensity alone without prior segmentation. To enhance the C-arm images, the authors investigated a three-step cascade filter and a line enhancement filter. The authors tested the method on a composite fiducial containing beads, straight lines, and ellipses. Ground-truth C-arm pose was provided by a clinically proven method. Results: Using 111 clinical C-arm images and {+-}10 deg. and {+-}10 mm random perturbation around the ground-truth pose, a total of 2775 cases were evaluated. The average rotation and translation errors were 0.62 deg. (STD=0.31 deg.) and 0.72 mm (STD=0.55 mm) for the three-step filter and 0.67 deg. (STD=0.40 deg.) and 0.87 mm (STD=0.27 mm) using the line enhancement filter. Conclusions: The C-arm pose tracking method was sufficiently accurate and robust on human patient data for subsequent 3D implant reconstruction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In Situ Analysis of Laser Powder Bed Fusion Using Simultaneous High-Speed Infrared and X-ray Imaging

Laser powder bed fusion is a metal additive manufacturing technique that has received significant scientific and industrial attention over the past decades. However, the quality and reproducibility of parts manufactured by this technique is still a problem. Overcoming this issue requires an understanding of multiple complex physical phenomena which occur simultaneously during the process. Here, we illustrate a powerful new technique which synchronizes high-speed x-ray imaging with high-speed infrared imaging to study laser powder bed fusion processes in real time. Using this technique, we demonstrate the simultaneous observation of multiple phenomena including three-dimensional melt pool visualization, vapor plume dynamics, spatter formation, thermal history, and point cooling rates. The paired observation of these dynamic phenomena is critical to understanding the fundamentals of laser powder bed fusion, and the overall impact of process parameters on print quality.

36 MATERIALS SCIENCE↗

Performance of Compact Pulsed Thermal Imaging System for In-Service Applications. Pulsed thermal tomography nondestructive examination of additively manufactured reactor materials and components

Additive manufacturing (AM) is an emerging method for cost-efficient fabrication of complex topology nuclear reactor parts from high-strength corrosion resistance alloys, such as stainless steel and Inconel. AM of metallic structures for nuclear energy applications is currently based on laser powder bed fusion (LPBF) process, which has the capability of melting metallic powder and net shaping the structures with relatively high precision. Some of the challenges with using LPBF method for nuclear manufacturing include the possibility of introducing pores into metallic structures. Integrity of AM structures needs to be evaluated nondestructively because material flaws could lead to premature failures due to creep in high temperature nuclear reactor environment. Currently, there exist limited capabilities to evaluate actual AM structures nondestructively. Pulsed Thermography (PT) imaging provides a capability for non-destructive evaluation (NDE) of sub-surface defects in arbitrary size structures. The PT method is based on recording material surface temperature transients with infrared (IR) camera following thermal pulse delivered on material surface with flash light. The PT method has advantages for NDE of actual AM structures because the method involves one-sided non-contact measurements and fast processing of large sample areas captured in one image. The data cube of PT measurements consists of surface temperature taken at sequential time intervals T(x,y,t). Material defects can be detected either by analyzing the thermograms T(x,y,t) data cube, or by using thermal tomography (TT) algorithm to obtain 3D spatial reconstruction of thermal effusivity e(x,y,z). To reduce the cost and enable in-service NDE in spatially constrained environment, it is highly desirable to develop PT with compact and inexpensive IR camera. Following initial qualification of an AM component for deployment in a nuclear reactor, a compact PT system can also be used for in-service nondestructive evaluation (NDE) applications. However, data cube obtained with PT based on compact IR camera suffers from strong thermal noises and loss of features due to relatively low sampling rate. In this report we describe two unsupervised machine learning (ML) algorithms for enhancement of PT images obtained with compact IR camera. In one approach, we introduce Sparse Coding Discrete Cosine Transform (SC/DCT) algorithm to remove additive white Gaussian noise (AWGN) from spatial thermal effusivity reconstructions. In another approach we introduce a Spatial Temporal Denoised Thermal Source Separation (STDTSS) ML algorithm to process thermograms. The STDTSS algorithm consists of spatial and temporal denoising using Gaussian and Savitzky–Golay filtering, followed by the matrix decomposition using Principal Component Analysis (PCA), and Independent Component Analysis (ICA) to automatically detect flaws. In the work described in this report, we constructed a compact PT system using a relatively small and low-cost FLIR A65 camera, consisting on uncooled microbolometer detector. Performance of SC/DCT algorithm was demonstrated on enhancing TT images of Inconel 718 AM plate. Performance of the STDTSS methods was investigated using thermography data obtained from imaging stainless steel 316L specimens produced with LPBF method with imprinted calibrated porosity defects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Comparison of automated chemical-guided segmentation and human annotation of soil organic matter in X-ray microcomputed tomography imaging in contrasted soil types

Soil organic matter (OM) formation and persistence is strongly influenced by the spatial distribution of organic substrates and microscale soil heterogeneity by dictating OM accessibility to microorganisms. However, traditional size and/or density fractionation techniques disrupt aggregate architecture, eliminating spatial information needed to fully understand intra-aggregate OM distribution. To quantify three-dimensional OM spatial distribution and automate segmentation in X-ray microcomputed tomography (µCT) imaging without human annotation bias, we developed an iodine gas vapor (I2) based staining workflow that eliminates labor-intensive manual annotation while maintaining segmentation accuracy, using aggregates from four taxonomically diverse soils (Xerofluvent, Haploxeroll Sphagnofibrist, Palehumult) with an 8-fold range of soil organic carbon. Human annotation of 10 µCT slices by the experienced and inexperienced annotators resulted in variations up to 3% in the Dice similarity coefficient (DSC), reflecting a degree of inherent subjectivity of manual labeling. Such inconsistencies are expected to compound as the number of manually annotated slices increases. Dual-energy µCT imaging at 33.1 keV (below the iodine (I) K-edge) and 33.2 keV (above the I K-edge) was used to resolve aggregate microstructure following I2 staining. The automated image subtraction pipeline identified OM regions by the I Kedge induced brightness increases, achieving DSC values of 0.58–0.83 relative to an experienced annotator. Sensitivity analyses revealed that the reconstruction alpha value—optimized via the open-source tool TomocuPy—and the 3D registration slice count were the primary determinants of accuracy, providing a novel benchmark for dual-energy soil imaging. The pipeline without GPU acceleration achieved 9.6 to 43.2 times faster than manual annotation. Using GPU-accelerated image post-processing and affine transformation matrices, the pipeline successfully segmented OM elements for large-scale datasets (3232×3232 pixel, 2048 slices) within ~5200 s from raw file acquisition to segmented output. The high-throughput approach enables the quantification of OM spatial distribution across diverse and heterogeneous soil.

Soil microbial biomass↗

SU-E-I-74: Image-Matching Technique of Computed Tomography Images for Personal Identification: A Preliminary Study Using Anthropomorphic Chest Phantoms

Purpose: Fingerprints, dental impressions, and DNA are used to identify unidentified bodies in forensic medicine. Cranial Computed tomography (CT) images and/or dental radiographs are also used for identification. Radiological identification is important, particularly in the absence of comparative fingerprints, dental impressions, and DNA samples. The development of an automated radiological identification system for unidentified bodies is desirable. We investigated the potential usefulness of bone structure for matching chest CT images. Methods: CT images of three anthropomorphic chest phantoms were obtained on different days in various settings. One of the phantoms was assumed to be an unidentified body. The bone image and the bone image with soft tissue (BST image) were extracted from the CT images. To examine the usefulness of the bone image and/or the BST image, the similarities between the two-dimensional (2D) or threedimensional (3D) images of the same and different phantoms were evaluated in terms of the normalized cross-correlation value (NCC). Results: For the 2D and 3D BST images, the NCCs obtained from the same phantom assumed to be an unidentified body (2D, 0.99; 3D, 0.93) were higher than those for the different phantoms (2D, 0.95 and 0.91; 3D, 0.89 and 0.80). The NCCs for the same phantom (2D, 0.95; 3D, 0.88) were greater compared to those of the different phantoms (2D, 0.61 and 0.25; 3D, 0.23 and 0.10) for the bone image. The difference in the NCCs between the same and different phantoms tended to be larger for the bone images than for the BST images. These findings suggest that the image-matching technique is more useful when utilizing the bone image than when utilizing the BST image to identify different people. Conclusion: This preliminary study indicated that evaluating the similarity of bone structure in 2D and 3D images is potentially useful for identifying of an unidentified body.

60 APPLIED LIFE SCIENCES↗

Fully Mechanically Controlled Automated Electron Microscopic Tomography

Knowledge of three-dimensional (3D) structures of each individual particles of asymmetric and flexible proteins is essential in understanding those proteins' functions; but their structures are difficult to determine. Electron tomography (ET) provides a tool for imaging a single and unique biological object from a series of tilted angles, but it is challenging to image a single protein for three-dimensional (3D) reconstruction due to the imperfect mechanical control capability of the specimen goniometer under both a medium to high magnification (approximately 50,000-160,000×) and an optimized beam coherence condition. Here, we report a fully mechanical control method for automating ET data acquisition without using beam tilt/shift processes. This method could reduce the accumulation of beam tilt/shift that used to compensate the error from the mechanical control, but downgraded the beam coherence. Our method was developed by minimizing the error of the target object center during the tilting process through a closed-loop proportional-integral (PI) control algorithm. The validations by both negative staining (NS) and cryo-electron microscopy (cryo-EM) suggest that this method has a comparable capability to other ET methods in tracking target proteins while maintaining optimized beam coherence conditions for imaging.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Insights into the Morphology and Kinetics of Growth of Silver Metal–Organic Nanotubes

The kinetics of the formation of novel porous metal organic nanotubes, [Ag2(4,4 -(1,4-(xylene)diyl)bis- (1,2,4-triazole) (NO3)2] NMP, was investigated by means of ex-situ time-resolved small-angle X-ray scattering (SAXS) and scanning electron microscopy (SEM). The SAXS results were modeled using the Gualtieri model, which decouples the nucleation and growth processes giving additional insight into the crystal formation mechanism. The results show that the semirigid 4,4 -(1,4-(xylene)diyl)bis(1,2,4-triazole) ligand (L) binds with silver ions, adopting a seesaw geometry to form a polydisperse isotropic framework immediately after mixing the ligands and metal ions. In addition, the SEM imaging demonstrates that the microcrystals grow anisotropically, with nucleation along the edge of the 3D aggregate. These combined data demonstrate that the growth of this MONT occurs in two steps: a rapid formation of an isotropic porous structure immediately after mixing the reactant, which then develops anisotropically as the aggregates of nanorods grow in a preferred direction. The anisotropic growth of the crystal is autocatalytic and determined by the rate of nucleation of new growth sites on the crystals. Moreover, the results of this analysis elucidate, for the rst time, the exact order of the competing processes that occur in the synthesis of these MONTs, showing that their anisotropic growth occurs on the initial 3D aggregate and appears to be directed by the interplay between the surface energies that exist during the MONT formation process. This insight is crucial to the use of crystal engineering to guide the crystal formation processes in MONTs to targeted structures, properties, and applications.

36 MATERIALS SCIENCE↗

Using micro-XRF to characterize chloride ingress through cold joints in 3D printed concrete

Digital fabrication methods with concrete have been rapidly developing, with many problems related to component production and material control being solved in recent years. These processes produce inherently layered cementitious components that are anisotropic, and in many cases, produces a weak interface between layers, which are generally referred to as cold joints. While material strength at these interfaces has been well studied in recent years, durability has received less attention, even though cold joints can function as channels for aggressive agents, such as chlorides. This work presents a method using micro-X-ray fluorescence (μXRF) to image chloride ingress into layer interfaces of 3D printed fine-grained concrete specimens produced with varying layer deposition time intervals, and also compares it to neutron imaging of moisture uptake. The results show that cold joints formed after a 1 day time interval are highly susceptible to chloride ingress, and that curing conditions play a major role in how quickly interfacial transport can take place. The μXRF method is also shown to be useful for study of transport of chlorides in cold joints, due to its spatial resolution and direct analysis of an aggressive species of interest.

36 MATERIALS SCIENCE↗

A real-time applicator position monitoring system for gynecologic intracavitary brachytherapy

Purpose: To develop a real-time applicator position monitoring system (RAPS) for intracavitary brachytherapy using an infrared camera and reflective markers. Methods: 3D image-guided brachytherapy requires high accuracy of applicator localization; however, applicator displacement can happen during patient transfer for imaging and treatment delivery. No continuous applicator position monitoring system is currently available. The RAPS system was developed for real-time applicator position monitoring without additional radiation dose to patients. It includes an infrared camera, reflective markers, an infrared illuminator, and image processing software. After reflective markers are firmly attached to the applicator and the patient body, applicator displacement can be measured by computing the relative change in distance between the markers. The reflective markers are magnetic resonance imaging (MRI) compatible, which is suitable for MRI-guided HDR brachytherapy paradigm. In our prototype, a Microsoft Kinect sensor with a resolution of 640 by 480 pixels is used as an infrared camera. A phantom study was carried out to compare RAPS' measurements with known displacements ranging from −15 to +15 mm. A reproducibility test was also conducted. Results: The RAPS can achieve 4 frames/s using a laptop with Intel{sup ®} Core™2 Duo processor. When the pixel size is 0.95 mm, the difference between RAPS' measurements and known shift values varied from 0 to 0.8 mm with the mean value of 0.1 mm and a standard deviation of 0.44 mm. The system reproducibility was within 0.6 mm after ten reposition trials. Conclusions: This work demonstrates the feasibility of a real-time infrared camera based gynecologic intracavitary brachytherapy applicator monitoring system. Less than 1 mm accuracy is achieved when using an off-the-shelf infrared camera.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deep reinforcement learning of cell movement in the early stage of C.elegans embryogenesis

Motivation: Cell movement in the early phase of Caenorhabditis elegans development is regulated by a highly complex process in which a set of rules and connections are formulated at distinct scales. Previous efforts have demonstrated that agent-based, multi-scale modeling systems can integrate physical and biological rules and provide new avenues to study developmental systems. However, the application of these systems to model cell movement is still challenging and requires a comprehensive understanding of regulatory networks at the right scales. Recent developments in deep learning and reinforcement learning provide an unprecedented opportunity to explore cell movement using 3D time-lapse microscopy images. Results: We present a deep reinforcement learning approach within an agent-based modeling system to characterize cell movement in the embryonic development of C.elegans. Our modeling system captures the complexity of cell movement patterns in the embryo and overcomes the local optimization problem encountered by traditional rule-based, agent-based modeling that uses greedy algorithms. Here, we tested our model with two real developmental processes: the anterior movement of the Cpaaa cell via intercalation and the rearrangement of the superficial left-right asymmetry. In the first case, the model results suggested that Cpaaa’s intercalation is an active directional cell movement caused by the continuous effects from a longer distance (farther than the length of two adjacent cells), as opposed to a passive movement caused by neighbor cell movements. In the second case, a leader-follower mechanism well explained the collective cell movement pattern in the asymmetry rearrangement. These results showed that our approach to introduce deep reinforcement learning into agent-based modeling can test regulatory mechanisms by exploring cell migration paths in a reverse engineering perspective. Lastly, this model opens new doors to explore the large datasets generated by live imaging. Availability and implementation: Source code is available at https://github.com/zwang84/drl4cellmovement.

59 BASIC BIOLOGICAL SCIENCES↗

A convolution-superposition dose calculation engine for GPUs

Purpose: Graphic processing units (GPUs) are increasingly used for scientific applications, where their parallel architecture and unprecedented computing power density can be exploited to accelerate calculations. In this paper, a new GPU implementation of a convolution/superposition (CS) algorithm is presented. Methods: This new GPU implementation has been designed from the ground-up to use the graphics card's strengths and to avoid its weaknesses. The CS GPU algorithm takes into account beam hardening, off-axis softening, kernel tilting, and relies heavily on raytracing through patient imaging data. Implementation details are reported as well as a multi-GPU solution. Results: An overall single-GPU acceleration factor of 908x was achieved when compared to a nonoptimized version of the CS algorithm implemented in PlanUNC in single threaded central processing unit (CPU) mode, resulting in approximatively 2.8 s per beam for a 3D dose computation on a 0.4 cm grid. A comparison to an established commercial system leads to an acceleration factor of approximately 29x or 0.58 versus 16.6 s per beam in single threaded mode. An acceleration factor of 46x has been obtained for the total energy released per mass (TERMA) calculation and a 943x acceleration factor for the CS calculation compared to PlanUNC. Dose distributions also have been obtained for a simple water-lung phantom to verify that the implementation gives accurate results. Conclusions: These results suggest that GPUs are an attractive solution for radiation therapy applications and that careful design, taking the GPU architecture into account, is critical in obtaining significant acceleration factors. These results potentially can have a significant impact on complex dose delivery techniques requiring intensive dose calculations such as intensity-modulated radiation therapy (IMRT) and arc therapy. They also are relevant for adaptive radiation therapy where dose results must be obtained rapidly.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effects of rapid thermal annealing on the structural and local atomic properties of ZnO: Ge nanocomposite thin films

We have investigated the structural and local atomic properties of Ge nanocrystals (Ge-ncs) embedded ZnO (ZnO: Ge) thin films. The films were deposited by sequential sputtering of ZnO and Ge thin film layers on z-cut quartz substrates followed by an ex-situ rapid thermal annealing (RTA) at 600 °C for 30, 60, and 90 s under forming gas atmosphere. Effects of RTA time on the evolution of Ge-ncs were investigated by x-ray diffraction (XRD), scanning electron microscopy (SEM), hard x-ray photoelectron spectroscopy (HAXPES), and extended x-ray absorption fine structure (EXAFS). XRD patterns have clearly shown that fcc diamond phase Ge-ncs of sizes ranging between 18 and 27 nm are formed upon RTA and no Ge-oxide peak has been detected. However, cross-section SEM images have clearly revealed that after RTA process, Ge layers form varying size nanoclusters composed of Ge-ncs regions. EXAFS performed at the Ge K-edge to probe the local atomic structure of the Ge-ncs has revealed that as prepared ZnO:Ge possesses Ge-oxide but subsequent RTA leads to crystalline Ge structure without the oxide layer. In order to study the occupied electronic structure, HAXPES has been utilized. The peak separation between the Zn 2p and Ge 3d shows no significant change due to RTA. This implies little change in the valence band offset due to RTA.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

High-Energy X-ray Tomographic Analysis of Precursor Metal Powders (Ti-6Al-4V) Used for Additive Manufacturing

We utilized high-energy x-ray tomography to characterize Ti-6Al-4V metal powders (both as-received and recycled) used in powder-bed additive manufacturing process. The image processing workflow was developed to process and analyze large amount of data objectively by computer program. The distribution of size and shape of the metal particles as well as defect (mainly porosity) inside the particles was analyzed with the statistical representation and resolution in micrometer. The result revealed that circular-shaped porosity with various sizes could be embedded in the powder particles. These porosities could potentially be transferred to the 3D printed part and critically affect the mechanical performance of the component. The present study shows the effectiveness of characterizing metal powders using x-ray imaging techniques where sufficient number of particles can be sampled within tens of minutes with a minimum sample preparation and high accuracy. Clear structural differences in the as-received and recycled powders were delineated that helps in determining the feasibility of using the recycled powders.

36 MATERIALS SCIENCE↗

SU-F-E-13: Design and Fabrication of Gynacological Brachytherapy Shielding & Non Shielding Applicators Using Indigenously Developed 3D Printing Machine

Purpose: In this innovative work we have developed Gynecological Brachytherapy shielding & Non Shielding Applicators and compared with the commercially available applicators by using the indigenously developed 3D Printing machine. Methods: We have successfully indigenously developed the 3D printing machine. Which contain the 3 dimensional motion platform, Heater unit, base plate, ect… To fabricate the Gynecological Brachytherapy shielding & non shielding applicators the 3D design were developed in the computer as virtual design. This virtual design is made in a CAD computer file using a 3D modeling program. Separate programme for the shielding & non shielding applicators. We have also provided the extra catheter insert provision in the applicator for the multiple catheter. The DICOM file of the applicator were then converted to stereo Lithography file for the 3D printer. The shielding & Non Shielding Applicators were printed on a indigenously developed 3D printer material. The same dimensions were used to develop the applicators in the acrylic material also for the comparative study. A CT scan was performed to establish an infill-density calibration curve as well as characterize the quality of the print such as uniformity and the infill pattern. To commission the process, basic CT and dose properties of the printing materials were measured in photon beams and compared against water and soft tissue. Applicator were then scanned to confirm the placement of multiple catheter position. Finally dose distributions with rescanned CTs were compared with those computer-generated applicators. Results: The doses measured from the ion Chamber and X-Omat film test were within 2%. The shielded applicator reduce the rectal dose comparatively with the non shielded applicator. Conclusion: As of submission 3 unique cylinders have been designed, printed, and tested dosimetrically. A standardizable workflow for commissioning custom 3D printed applicators was codified and will be reported.

60 APPLIED LIFE SCIENCES↗

WE-F-16A-04: Micro-Irradiator Treatment Verification with High-Resolution 3D-Printed Rodent-Morphic Dosimeters

Purpose: Pre-clinical micro-radiation therapy studies often utilize very small beams (∼0.5-5mm), and require accurate dose delivery in order to effectively investigate treatment efficacy. Here we present a novel high-resolution absolute 3D dosimetry procedure, capable of ∼100-micron isotopic dosimetry in anatomically accurate rodent-morphic phantoms Methods: Anatomically accurate rat-shaped 3D dosimeters were made using 3D printing techniques from outer body contours and spinal contours outlined on CT. The dosimeters were made from a radiochromic plastic material PRESAGE, and incorporated high-Z PRESASGE inserts mimicking the spine. A simulated 180-degree spinal arc treatment was delivered through a 2 step process: (i) cone-beam-CT image-guided positioning was performed to precisely position the rat-dosimeter for treatment on the XRad225 small animal irradiator, then (ii) treatment was delivered with a simulated spine-treatment with a 180-degree arc with 20mm x 10mm cone at 225 kVp. Dose distribution was determined from the optical density change using a high-resolution in-house optical-CT system. Absolute dosimetry was enabled through calibration against a novel nano-particle scintillation detector positioned in a channel in the center of the distribution. Results: Sufficient contrast between regular PRESAGE (tissue equivalent) and high-Z PRESAGE (spinal insert) was observed to enable highly accurate image-guided alignment and targeting. The PRESAGE was found to have linear optical density (OD) change sensitivity with respect to dose (R{sup 2} = 0.9993). Absolute dose for 360-second irradiation at isocenter was found to be 9.21Gy when measured with OD change, and 9.4Gy with nano-particle detector- an agreement within 2%. The 3D dose distribution was measured at 500-micron resolution Conclusion: This work demonstrates for the first time, the feasibility of accurate absolute 3D dose measurement in anatomically accurate rat phantoms containing variable density PRESAGE material (tissue equivalent and bone equivalent). This method enables precise treatment verification of micro-radiation therapies, and enhances the robustness of tumor radio-response studies. This work was supported by NIH R01CA100835.

60 APPLIED LIFE SCIENCES↗

A Novel Method for Preoperative Positioning of Total Ankle Replacement Using 3D Digital Model

Abstract Objective To establish a digital model of the ankle joint through 3D imaging technology and explore the preoperative placement of ankle replacement prostheses. Methods Computed tomography images of intact ankle joints from 54 cases in the outpatient and inpatient departments of our hospital were collected; according to the INBONE® total ankle system surgery process, the surgery model and surgical osteotomy were finished using MIMICS based on computer simulation method. The shortest distance was measured between the center point and the anterior, posterior, medial, and lateral, respectively, to ensure the precise position of the ankle replacement prosthesis by digital simulation surgery. The relationship between the two variables was analyzed by bivariate correlation analysis. Results The dataset of this study included 48 cases of the sub‐data set (26 males and 22 females) and included 27 cases of left ankle and 21 cases of right ankle. The average medial malleolar angle was 18.67°± 2.87°, the average amount of bone resection was 12.13 ± 1.86 cm 3 , the mid‐anterior distance was 1.72 ± 0.19 cm, the mid‐posterior distance was 2.00 ± 0.19 cm, the ratio of mid‐anterior to mid‐posterior was 0.87, the mid‐medial distance was 1.26 ± 0.17 cm, the mid‐lateral distance was 1.19 ± 0.16 cm, and the ratio of mid‐medial to mid‐lateral was 1.06. After osteotomy, the anteroposterior diameter was 3.73 ± 0.32 cm, the transverse diameter was 2.46 ± 0.27 cm, and the ratio of anteroposterior diameter to transverse diameter was 1.53. In the bottom view, the shape after osteotomy is rectangular. The mid‐anterior distance was strongly negatively correlated with age, the mid‐anterior distance and the amount of bone resection, the mid‐medial distance and the amount of bone resection, the mid‐lateral distance and the amount of bone resection, the mid‐lateral distance and the anteroposterior diameter, the anteroposterior diameter and the transverse diameter were all strongly positively correlated. Conclusion The projection point of the lower tibia centerline on the tibial horizontal osteotomy surface is located at a position slightly anterior to the midpoint of the transverse diameter after ankle arthroplasty. The rational positioning of the total ankle replacement is located at both a position slightly anterior to the midpoint of the transverse diameter and midpoint of the anteroposterior diameter, which can be used as a reference method before total ankle arthroplasty surgery.

Wu, Shi‐xun↗

TU-F-CAMPUS-I-02: Contrast Enhanced Cone Beam CT Imaging with Dual- Gantry Image Acquisition and Constrained Iterative Reconstruction-a Simulation Study for Liver Imaging Application

Purpose: Contrast time-density curves may help differentiate malignant tumors from normal tissues or benign tumors. Repetitive scans using conventional CT or cone beam CT techniques, which Result in unacceptably high dose, may not achieve the desired temporal resolution. In this study we describe and demonstrate a 4D imaging technique for imaging and quantifying contrast flows requiring only one or two 360° scans. Methods: A dual-gantry system is used to simultaneously acquire two projection images at orthogonal orientations. Following the scan, each or both of the two 360° projection sets are used to reconstruct an average contrast enhanced image set which is then segmented to form a 3D contrast map. Alternatively, a pre-injection scan may be made and used to reconstruct a pre-injection image set which is subtracted from the post-injection image set to form the 3D contrast map. Each of the two 360° projection sets is divided into 12 subsets, thus creating 12 pairs of 30° limited angle projection sets, each corresponding to a time spanning over 1/12 of the scanning time. Each pair of the projection sets are reconstructed as a time specific 3D image set with the maximum likelihood estimation iterative algorithm using the contrast map as the constraint. As a demonstration, a 4D abdominal phantom was constructed from clinical CT images with blood flow through the normal tissue and a tumor modeled and imaging process simulated. Results: We have successfully generated a 4D image phantom, and calculated the projection images. The time density curves derived from the reconstructed image set matched well with the flow model used to generate the phantom. Conclusion: Dual-gantry image acquisition and constrained iterative reconstruction algorithm may help to obtain time-density curves of contrast agents in blood flows, which may help differentiate malignant tumors from normal tissues or benign tumors.

60 APPLIED LIFE SCIENCES↗

Fine-tuning TrailMap: The utility of transfer learning to improve the performance of deep learning in axon segmentation of light-sheet microscopy images

Light-sheet microscopy has made possible the 3D imaging of both fixed and live biological tissue, with samples as large as the entire mouse brain. However, segmentation and quantification of that data remains a time-consuming manual undertaking. Machine learning methods promise the possibility of automating this process. This study seeks to advance the performance of prior models through optimizing transfer learning. We fine-tuned the existing TrailMap model using expert-labeled data from noradrenergic axonal structures in the mouse brain. By changing the cross-entropy weights and using augmentation, we demonstrate a generally improved adjusted F1-score over using the originally trained TrailMap model within our test datasets.

97 MATHEMATICS AND COMPUTING↗