Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “wind turbine generator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

High-Fidelity Modeling of a Type-5 Wind Turbine Gearbox (Intern Poster) [Poster]

Type-5 wind turbines are unique in their use of a permanent magnet synchronous generator, as well as their use of a hydraulic torque converter. This architecture presents an opportunity to provide steady and grid-ready energy without the need for a power converter. With infrastructure continuity and reliability being an important topic amongst renewable energies, researchers have been prompted to further investigate the benefits of type-5 turbines’ unique electromechanical configuration on stable electricity generation. Researchers involved in the WindSG project, SG standing for synchronous generator, are aiming to model a type-5 turbine using Real Time Digital Simulation (RTDS) to evaluate its efficacy in the grid. RSCAD, the software run on the RTDS, comes pre-loaded with electrical and electromechanical components to help simulate electrical generation and grid conditions. However, within this repertoire there is a lack of a component to represent a gearbox with high-fidelity. Within RSCAD’s case studies, the gearbox is often represented simply by a gear ratio value. This presented the task of developing a high-fidelity gearbox model in RSCAD for use in the larger RTDS type-5 wind turbine model. This poster describes a method of developing a lumped parameter mathematical model to represent a planetary-parallel-parallel gearbox in RSCAD for use in RTDS.

17 WIND ENERGY↗

High-Fidelity Modeling of a Type-5 Wind Turbine Gearbox (Intern Technical Presentation) (Poster)

Type-5 wind turbines are unique in their use of a permanent magnet synchronous generator, as well as their use of a hydraulic torque converter. This architecture presents an opportunity to provide steady and grid-ready energy without the need for a power converter. With infrastructure continuity and reliability being an important topic amongst renewable energies, researchers have been prompted to further investigate the benefits of type-5 turbines’ unique electromechanical configuration on stable electricity generation. Researchers involved in the WindSG project, SG standing for synchronous generator, are aiming to model a type-5 turbine using Real Time Digital Simulation (RTDS) to evaluate its efficacy in the grid. RSCAD, the software run on the RTDS, comes pre-loaded with electrical and electromechanical components to help simulate electrical generation and grid conditions. However, within this repertoire there is a lack of a component to represent a gearbox with high-fidelity. Within RSCAD’s case studies, the gearbox is often represented simply by a gear ratio value. This presented the task of developing a high-fidelity gearbox model in RSCAD for use in the larger RTDS type-5 wind turbine model. This presentation describes a method of developing a lumped parameter mathematical model to represent a planetary-parallel-parallel gearbox in RSCAD for use in RTDS.

17 WIND ENERGY↗

Comparison of wind-farm control strategies under realistic offshore wind conditions: wake quantities of interest

Wind-farm control strategies aim to increase the efficiency, and therefore lower the levelized cost of energy, of wind farms. This is done by using turbine settings such as the yaw angle, blade pitch angles, or generator torque to manipulate the wake that negatively affects downstream turbines in the farm. Two inherently different wind-farm control methods have been identified in the literature: wake steering (WS) and active wake mixing (AWM). As one of two companion papers focused on understanding practical aspects of these two wind-farm control strategies using large-eddy simulation (LES), we below analyze the wake quantities of interest for a single wind turbine performing WS and AWM, while the companion article (Frederik et al., 2025) focuses on turbine quantities of interest including power and structural loads for the same computational setup and also includes two-turbine arrays with full and partial wake overlap. The simulations, which are based in the LES solver AMR-Wind, are tailored to have inflow conditions representative of measurements from a site off the East Coast of the US, including with strong veer and low turbulence. The turbine, which is modeled in OpenFAST and coupled to the LES, is the IEA 15 MW, an open-source offshore design. After presenting an overview of the wake recovery for the different wake-control cases, the analysis probes the fluid-dynamic causes for the different performance of the arrays reported in the companion article by examining control volumes around the wakes and the budget of the mean-flow kinetic energy (MKE) within these volumes. In the high veer environment considered, the MKE recovery is dominated by mean convection, and this is shown to especially benefit the WS strategy when a neighboring turbine is directly downstream: there is ≈65 % more available power for a downstream turbine than in the baseline case, and this power is gained primarily through mean convection on the left-tip and top-tip faces of the control volume. However, the case with imperfect knowledge of the exact wind direction favors the pulse-type AWM strategy, largely because of ≈9 % increased turbulent entrainment from aloft versus the baseline that could be related to an apparent resistance to skewing in the pulsed wake. The general reduced effectiveness of helix-type and other individual-pitch-based AWM strategies for inflow with high veer and low turbulence as reported in the companion paper is due, in part, to low magnitudes of phase-averaged turbulent entrainment. Two main findings of this study are thus that veer has a significant impact on the effectiveness of different wake-control strategies and that pulse-type AWM may be a useful strategy when the objective is power maximization in realistic, offshore flow environments with imperfect knowledge of the exact wake overlap position on the downstream turbine.

17 WIND ENERGY↗

An accumulation method for early fault warning and its application to wind turbine systems

Unexpected failures in engineering systems lead to expensive maintenance actions and should be avoided if at all possible. This is particularly true for wind turbine systems for which unexpected failures not only demand costly repairs but also cause long downtime. Motivated by this need, we present an accumulation method for fault early warning and failure anticipation. Here, our research shows that one critical element allowing the ability of early warning is to accumulate the small-magnitude symptoms resulting from gradual changes in an engineering system like wind turbines. Our idea is inspired by the classical cumulative sum method, or CUSUM, but we have to redesign the accumulation mechanism for tackling unique challenges in wind turbine data. The new accumulation method is applied to two real wind turbine datasets, one with gearbox failures and the other with generator failures, and demonstrates superior performance as compared with CUSUM.

17 WIND ENERGY↗

Graph Neural Networks for Surrogate Modeling of Offshore Floating Platforms

Floating offshore wind turbines (FOWTs) present an significant opportunity to increase renewable energy generation. However, significant challenges remain before FOWTs can be widely commercialized and deployed. In particular, hydrodynamic loading on the platforms can stress the overall structure, damage the mooring systems, and impact power generation. Studying these loads is difficult and often relies on computationally expensive models or experiments. In this work, we explore the use of graph neural networks (GNNs) to construct flexible, data-driven surrogates for hydrodynamic loads on platforms. We leverage the natural graph-like structure of offshore wind platform designs to enable the GNN model to learn to approximate the loads for different wave conditions and structural designs. We demonstrate potential uses for the surrogate by performing parameter sweeps and ridge analysis on the trained model to identify the impacts of different wave and structural features on the loads.

floating offshore wind turbines↗

Invertible Neural Networks for Aerodynamic Design of Wind Turbine Blades

The state-of-the-practice methods for aerodynamic design of wind turbine blads use linearized blade element momentum theory (BEM) to optimize the twist and chord profiles from a pre-selected set of 2D airfoil shapes. In this work, we apply invertible neural network (INN) tools to enable the rapid inverse aerodynamic design of wind turbine blades including component airfoils. The INN is trained on data obtained through the use of robust automated mesh generation and the HAMSTR computational fluid dynamics solver with advanced turbulence and transition models validated for turbine applications. Our design technique is a significant improvement over the state-of-the-practice linearized blade element momentum (BEM) techniques in capturing 3D nonlinear aerodynamic effects that are critical for optimal design of the rotors. This is made possible by developing sparse, invertible neural networks (INNs) for inverse design and optimization that realize a 100x cost reduction compared to adjoint-based computational fluid dynamics (CFD) approaches, while enabling increased robustness of the final design. We demonstrate the INN tool for design of a section of the NREL 5-MW blade. All generated shapes satisfy the desired aerodynamic characteristics, demonstrating the success of the INN approach for inverse design of wind turbine blades.

aerodynamic design↗

The Area Localized Coupled Model for Analytical Mean Flow Prediction in Arbitrary Wind Farm Geometries

This work introduces the area localized coupled (ALC) model, which extends the applicability of approaches that couple classical wake superposition models and atmospheric boundary layer models to wind farms with arbitrary layouts. Coupling wake and top–down boundary layer models is particularly challenging since the latter requires averaging over planform areas associated with turbine-specific regions of the flow that need to be specified. The ALC model uses Voronoi tessellation to define this local area around each turbine. A top–down description of a developing internal boundary layer is then applied over Voronoi cells upstream of each turbine to estimate the local mean velocity profile. Coupling between the velocity at hub-height based on this localized top–down model and a wake model is achieved by enforcing a minimum least-square-error in mean velocity in each cell. The wake model in the present implementation takes into account variations in wind farm inflow velocity and represents the wake profile behind each turbine as a super-Gaussian function that smoothly transitions between a top-hat shape in the region immediately following the turbine to a Gaussian profile downstream. Detailed comparisons to large-eddy simulation (LES) data from two different wind farms demonstrate the efficacy of the model in accurately predicting both wind farm power output and local turbine hub-height velocity for different wind farm geometries. These validations using data generated from two different LES codes demonstrate the model's versatility with respect to capturing results from different simulation setups and wind farm configurations.

49 EE - Wind and Water Power Program - Wind (EE-4W↗

Distributed Wind Controls: A Research Roadmap for Microgrids, Infrastructure Resilience, and Controls Launchpad (MIRACL)

The Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL) project’s controls research area aims to expand the benefits from distributed wind (DW) generation assets beyond solely providing low cost power directly to consumers. To make distributed wind turbines operate more effectively there is a need for more advanced ways to control them, allowing power companies, businesses, and energy consumers to take advantage of the unique characteristics of wind energy. DW can contribute to the safe and secure operation of grid by providing services such as voltage regulation, frequency regulation, spinning reserves, and even black start capabilities. In the larger DER context where much of the research has focused around solar technologies, the inertia available in wind technologies has generally not been considered. For wind turbines to provide these services in an optimal and expanded way, development and demonstration of control methods and communication interfaces within a grid and microgrid framework are required. In this document, NREL led the literature review in collaboration with SNL, of DER controls-focused integration research to establish a baseline for the controls research under the MIRACL project to identify specific control functions to be focused on throughout this project. This literature review focused primarily on the control functions of variable distributed generation, largely pulling from past solar PV and battery controls works, with a specific focus on applicability for distributed wind energy systems. The goal of this document is to identify a research roadmap based on the open literature and past national laboratory works to inform advanced wind turbine and power electronics control functions for four use cases: 1) distributed wind in isolated systems, 2) grid-connected microgrids (wind-hybrid systems and islanded operation), 3) behind-the-meter distributed wind applications in the power distribution systems, and 4) front-of-the-meter distributed wind applications in the power distribution systems.

17 WIND ENERGY↗

On the characteristics of the wake of a wind turbine undergoing large motions caused by a floating structure: an insight based on experiments and multi-fidelity simulations from the OC6 project Phase III

This study reports the results of the second round of analyses of the Offshore Code Comparison, Collaboration, Continued, with Correlation and unCertainty (OC6) project Phase III. While the first round investigated rotor aerodynamic loading, here, focus is given to the wake behavior of a floating wind turbine under large motion. Wind tunnel experimental data from the UNsteady Aerodynamics for FLOating Wind (UNAFLOW) project are compared with the results of simulations provided by participants with methods and codes of different levels of fidelity. The effect of platform motion on both the near and the far wake is investigated. More specifically, the behavior of tip vortices in the near wake is evaluated through multiple metrics, such as streamwise position, core radius, convection velocity, and circulation. Additionally, the onset of velocity oscillations in the far wake is analyzed because this can have a negative effect on stability and loading of downstream rotors. Results in the near wake for unsteady cases confirm that simulations and experiments tend to diverge from the expected linearized quasi-steady behavior when the rotor reduced frequency increases over 0.5. Additionally, differences across the simulations become significant, suggesting that further efforts are required to tune the currently available methodologies in order to correctly evaluate the aerodynamic response of a floating wind turbine in unsteady conditions. Regarding the far wake, it is seen that, in some conditions, numerical methods overpredict the impact of platform motion on the velocity fluctuations. Moreover, results suggest that the effect of platform motion on the far wake, differently from original expectations about a faster wake recovery in a floating wind turbine, seems to be limited or even oriented to the generation of a wake less prone to dissipation.

17 WIND ENERGY↗

Chapter 14 - Reliability of Wind Turbines

The global wind energy industry has grown at a fast pace during the past half-decade. Advancements from design and manufacturing to operation and maintenance have led to reduced capital and maintenance costs, which make wind power an indispensable source for a comprehensive solution to global electricity needs. Once wind turbines are installed, the opportunity to lower wind power costs is mainly through improved operation and maintenance practices. Modern wind turbines are equipped with tens or hundreds of measurement channels and are generating an abundance of data, with lot of efforts being put into data analysis by both the research community and the industry. One type of analysis is through the exploration of reliability engineering methods based on readily available data or maintenance records collected at typical wind power plants. If adopted and conducted appropriately, these analyses can quickly save operation and maintenance costs in a potentially impactful manner. The wind industry has adopted this discipline more broadly in recent years. This chapter discusses wind turbine reliability by highlighting the methodology of reliability engineering life data analysis. It first briefly discusses the fundamentals of wind turbine reliability and the current industry status. Then, the reliability engineering method for life analysis, including data collection, model development, and forecasting, is presented in detail and illustrated through two case studies. The chapter concludes with some remarks on potential opportunities to improve wind turbine reliability. An owner and operator's perspective is taken and mechanical components are used to exemplify the potential benefits of reliability engineering analysis to improve wind turbine reliability and availability.

database↗

The Oregon State University wind studies

The economic feasibility of commercial use of wind generated power in selected areas of Oregon is assessed. A number of machines for generating power have been examined. These include the Savonius rotor, translators, conventional wind turbines, the circulation controlled rotor and the vertical axis winged turbine. Of these machines, the conventional wind turbine and the vertical axis winged turbine show the greatest promise on the basis of the power developed per unit of rotor blade area. Attention has been focused on the structural and fatigue analysis of rotors since the economics of rotary winged, wind generated power depends upon low cost, long lifetime rotors. Analysis of energy storage systems and tower design has also been undertaken. An economic means of energy storage has not been found to date. Tower design studies have produced cost estimates that are in general agreement with the cost of the updated Putnam 110-foot tower.

Wilson, R. E.↗

Wind energy utilization: A bibliography with abstracts - Cumulative volume 1944/1974

Bibliography, up to 1974 inclusive, of articles and books on utilization of wind power in energy generation. Worldwide literature is surveyed, and short abstracts are provided in many cases. The citations are grouped by subject: (1) general; (2) utilization; (3) wind power plants; (4) wind power generators (rural, synchronous, remote station); (5) wind machines (motors, pumps, turbines, windmills, home-built); (6) wind data and properties; (7) energy storage; and (8) related topics (control and regulation devices, wind measuring devices, blade design and rotors, wind tunnel simulation, aerodynamics). Gross-referencing is aided by indexes of authors, corporate sources, titles, and keywords.

Source record↗

How many offshore wind turbines does New England need?

The proliferation of countries and regions with 100% clean or renewable energy targets necessitates an analysis to determine the number of generating units and storage needed to meet real-time electricity demand on the electric grid. The coastal areas of New England have the capacity to produce a large percentage of the region's energy needs with offshore wind turbines. Here we model offshore wind turbine power production data using MERRA-2 reanalysis and lidar wind speed data sets. We compare this power production to the New England hourly grid demand over the course of one year. 2,000 10 MW offshore wind turbines could satisfy New England's grid demand for about 37% of the year. When combined with 55 GWh of storage, 2,000 turbines could satisfy grid demand for about 72% of the year.

17 WIND ENERGY↗

Learning from Arctic Microgrids: Cost and Resiliency Projections for Renewable Energy Expansion with Hydrogen and Battery Storage

Electricity in rural Alaska is provided by more than 200 standalone microgrid systems powered predominantly by diesel generators. Incorporating renewable energy generation and storage to these systems can reduce their reliance on costly imported fuel and improve sustainability; however, uncertainty remains about optimal grid architectures to minimize cost, including how and when to incorporate long-duration energy storage. This study implements a novel, multi-pronged approach to assess the techno-economic feasibility of future energy pathways in the community of Kotzebue, which has already successfully deployed solar photovoltaics, wind turbines, and battery storage systems. Using real community load, resource, and generation data, we develop a series of comparison models using the HOMER Pro software tool to evaluate microgrid architectures to meet over 90% of the annual community electricity demand with renewable generation, considering both battery and hydrogen energy storage. We find that near-term planned capacity expansions in the community could enable over 50% renewable generation and reduce the total cost of energy. Additional build-outs to reach 75% renewable generation are shown to be competitive with current costs, but further capacity expansion is not currently economical. We additionally include a cost sensitivity analysis and a storage capacity sizing assessment that suggest hydrogen storage may be economically viable if battery costs increase, but large-scale seasonal storage via hydrogen is currently unlikely to be cost-effective nor practical for the region considered. While these findings are based on data and community priorities in Kotzebue, we expect this approach to be relevant to many communities in the Arctic and Sub-Arctic regions working to improve energy reliability, sustainability, and security.

25 ENERGY STORAGE↗

Power output of turbines mounted on tension-leg platforms subjected to fully developed ocean gravity waves

A concern in the deployment of large wind turbines on ocean floating platforms is the effect of floating-platform motions on their electrical power generation. Further, it is not clear how floating motions influence waking, which might affect the combined power generation of collections of turbines. We examine the average power output of a single and a collection of NREL 5 MW wind turbines mounted on a tension-leg platform (TLP) under the action of fully developed ocean wave motions, coupling floating motions with the large-eddy simulation (LES) of atmospheric and rotor dynamics. The ocean dynamics enter as fully developed waves derived from the Pierson–Moskowitz spectrum. To assess the influence of ocean motions, we performed simulations over the full range of wind speeds in the operational range of the turbine, reporting comparisons of average power output when the platforms are allowed to move to when they are held rigidly in place. In all simulations, we find that the effects of the TLP floating-platform's induced motions have a minor effect on single and multiple turbine power production and wake deficits. Even when using coherent and large amplitude harmonic-floating-induced perturbations, any significant wake modifications from floating motions are confined to the near-wake region, where downstream turbines are unlikely to be located. The relatively small amplitude of TLP motions relative to pre-existing turbulent fluctuations are the primary reason for low wake and power modifications downstream.

Restrepo, Juan [ORNL] (ORCID:0000000326092882)↗

Distributed Energy Resource (DER) Reliability for Backup Electric Power Systems

Hospitals, emergency services, military bases, ports, airports, industries, commercial facilities, and others rely on backup power systems to provide electricity for their critical loads during grid outages. The purpose of this report it to provide accurate reliability information on commonly deployed distributed energy resources (DERs) to improve quantitative estimates for the reliability of these backup power systems during a grid outage. A backup power system consists of DERs, an electric distribution system with its associated switches and other devices, and mechanisms to control and manage the flow of electricity. Too often, facilities and campuses fail to properly quantify the reliability of their backup power systems. DERs are assumed to be 100% reliable, with the only concern being the availability of fuel. Such assumptions can lead to gross errors in the backup system's reliability estimates, particularly for long-duration outages. This report provides a set of estimates for reliability of emergency diesel generators (EDGs), natural gas prime generators and combined heat and power (CHP) prime movers, solar photovoltaics (PV), wind turbines, and Li-ion battery energy storage systems (BESS). The estimates are derived from empirical data when available and supplemented by modeling results when needed. These reliability estimates are for the DERs ability to provide power during a grid outage, ranging from an hour to 2 weeks.

14 SOLAR ENERGY↗

Enabling Floating Offshore VAWT Design by Coupling OWENS and OpenFAST

Vertical-axis wind turbines (VAWTs) have a long history, with a wide variety of turbine archetypes that have been designed and tested since the 1970s. While few utility-scale VAWTs currently exist, the placement of the generator near the turbine base could make VAWTs advantageous over tradition horizontal-axis wind turbines for floating offshore wind applications via reduced platform costs and improved scaling potential. However, there are currently few numerical design and analysis tools available for VAWTs. One existing engineering toolset for aero-hydro-servo-elastic simulation of VAWTs is the Offshore Wind ENergy Simulator (OWENS), but its current modeling capability for floating systems is non-standard and not ideal. This article describes how OWENS has been coupled to several OpenFAST modules to update and improve modeling of floating offshore VAWTs and discusses the verification of these new capabilities and features. The results of the coupled OWENS verification test agree well with a parallel OpenFAST simulation, validating the new modeling and simulation capabilities in OWENS for floating VAWT applications. These developments will enable the design and optimization of floating offshore VAWTs in the future.

17 WIND ENERGY↗

SAM™ (System Advisor Model™) [SWR-16-02, SWR-10-13]

See the SAM™ website to build a desktop version of the National Laboratory of the Rockies' (NLR's) System Advisor Model™ (SAM). https://sam.nlr.gov/ The System Advisor Model™ (SAM™) is a free techno-economic software model that facilitates decision-making for people in the renewable energy industry: -Project managers and engineers -Policy analysts -Technology developers -Researchers SAM can model many types of renewable energy systems: -Photovoltaic systems, from small residential rooftop to large utility-scale systems -Battery storage with Lithium ion, lead acid, or flow batteries for front-of-meter or behind-the-meter applications -Concentrating Solar Power systems for electric power generation, including parabolic trough, power tower, and linear Fresnel -Industrial process heat from parabolic trough and linear Fresnel systems -Wind power, from individual turbines to large wind farms -Marine energy wave and tidal systems -Solar water heating -Fuel cells -Geothermal power generation -Biomass combustion for power generation -High concentration photovoltaic systems SAM's financial models are for the following types of projects: -Residential and commercial projects where the renewable energy system is on the customer side of the electric utility meter (behind the meter), and power from the system is used to reduce the customer's electricity bill. -Power purchase agreement (PPA) projects where the system is connected to the grid at an interconnection point, and the project earns revenue through power sales. The project may be owned and operated by a single owner or by a partnership involving a flip or leaseback arrangement. -Third party ownership where the system is installed on the customer's (host) property and owned by a separate entity (developer), and the host is compensated for power generated by the system through either a PPA or lease agreement. For a more detailed description of SAM, see Blair et al. (2018), System Advisor Model (SAM) General Description (Version 2017.9.5), NREL/TP-6A20-70414. https://www.nrel.gov/docs/fy18osti/70414.pdf

Ryberg, David↗