Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “wind potential”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Generator Interconnection Cost Analysis in the Midcontinent Independent System Operator (MISO) territory

Electric transmission system operators (ISOs, RTOs, or utilities) require new large generators seeking to connect to the grid to undergo a series of impact studies before they can be built. This process establishes what new transmission equipment or upgrades may be needed before a project can connect to the system and assigns the costs of that equipment. Berkeley Lab has collected interconnection cost data from interconnection studies for the Midcontinent Independent System Operator (MISO), representing nearly 50% of all projects requesting interconnection from 2010 to 2020. Project-level cost summary data are available for download on this page. We find: -Average interconnection costs have grown as the number of interconnection requests have escalated -Projects that have completed all required interconnection studies have the lowest cost compared to applicants still actively working through the interconnection process or those that have withdrawn. -Broader network upgrade costs are the primary driver of recent cost increase. -Potential interconnection costs for wind, storage, and solar are larger than for natural gas -Larger generators have greater interconnection costs in absolute terms, but economies of scale exist on a per kW basis. -Interconnection costs vary by location Berkeley Lab will publish a series of short analytical papers of generator interconnection costs to the transmission system for MISO, PJM, SPP, ISO-NE and NYISO, which you can find at https://emp.lbl.gov/interconnection_costs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cyber-Physical Resiliency for Wind Power Generation

During the next three years, wind power generation is expected to add more generation capacity to the national electrical grid than any other energy sector. With new wind turbine designs rated power over 10 MW and wind farms reaching over 1 GW capacities, the consequences of cyber-attacks on wind power generation are becoming increasingly more critical. Moreover, the known vulnerabilities of wind turbine control systems and the potential damaging effects of intrusions, motivate an urgent protection improvement for the wind power generation sector. This program has developed a variety of new adaptive defense technologies that enable wind power generation systems to survive sophisticated cyberattacks by enhancing the control systems capabilities of detection, localization, and accommodation. The introduction of these technologies in the on-shore and the emerging off-shore market will result in a significantly more reliable and secure wind power infrastructure.

17 WIND ENERGY↗

Interconnection Cost Analysis in the PJM Territory

Electric transmission system operators (ISOs, RTOs, or utilities) require new large generators seeking to connect to the grid to undergo a series of impact studies before they can be built. This process establishes what new transmission equipment or upgrades may be needed before a project can connect to the system and assigns the costs of that equipment. Berkeley Lab has collected interconnection cost data from interconnection studies for the PJM Territory, representing nearly 86% of all new unique generators requesting interconnection from 2000 to 2022. Project-level cost summary data are available for download on this page. We find: -Average interconnection costs have grown as the number of interconnection requests have escalated -Projects that have completed all required interconnection studies have the lowest cost compared to applicants still actively working through the interconnection process or those that have withdrawn. -Broader network upgrade costs are the primary driver of recent cost increase. -Potential interconnection costs for wind, storage, and solar are larger than for natural gas -Larger generators have greater interconnection costs in absolute terms, but economies of scale exist on a per kW basis. -Interconnection costs vary by location Berkeley Lab will publish a series of short analytical papers of generator interconnection costs to the transmission system for MISO, PJM, SPP, ISO-NE and NYISO, which you can find at https://emp.lbl.gov/interconnection_costs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Weather Analysis for Xcel Energy's 2030 Colorado Preferred Plan

The Public Service Company of Colorado (PSCo), a subsidiary of Xcel Energy (Xcel), plans to meet its target of an 80% reduction in CO 2 emissions over 2005 levels by 2030 through its Preferred Plan1,2 that includes increasing the wind and solar energy on its system, reducing coal, and adjusting the operation and dispatch of new and existing thermal generation. The objective of our analysis reported here is to identify how the PSCo generation and transmission of its Preferred Plan might operate in the face of specific weather events. We investigate weather events that currently cause stress to PSCo’s system, such as winter storms and extreme heat. In addition, we explore how the future system responds to scenarios that may be considered normal weather conditions today, but that have a large impact on wind and solar generation potential.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Transformer Analysis with ANSYS Maxwell and COMSOL

This is an extension of work described by Rodriguez et al . (2021). It continues analyses of a generic transformer design by Wes Greenwood. In this report, we summarize that work and add comparable results using the ANSYS Maxwell software (henceforward, “ANSYS”), and with COMSOL . We found the ANSYS and COMSOL calculations of inductance agreed well with previous results for simplified coils in air, and with a ferromagnetic core. We then describe the ANSYS and COMSOL approach and show results for a full transformer model based on magnetic field analyses. Finally, we present electrostatic analyses of E field enhancement, once again resolving individual wires. The purpose is to assess the electrostatic fields in order to locate where electric breakdown is likely to originate. We found the maximum enhancement between the secondary and either the primary or the tertiary at the end of the windings with a large potential difference.

42 ENGINEERING↗

Hybrid Power Plants for Energy Resilience: A Case Study

As renewable energy technologies are increasingly adopted, they pose an opportunity to improve the sustainability and resilience of distributed grids, especially when their design and operation is coordinated as a hybrid power plant. When included in hybrid power plants, distributed wind turbines in particular have the potential to enhance the resilience of distributed grids in areas with good wind resource, due to their ability to provide more consistent generation and ancillary services as compared to photo-voltaic (PV) solar panels. Despite this benefit, U.S. distributed wind adoption is lower than other comparable renewable energy technologies. In this study, we seek to demonstrate how hybrid power plants that include distributed wind turbines can contribute to distribution grid resilience by meeting loads (especially critical loads) more consistently, increasing reserve capacity, and providing value to customers during outages. To demonstrate these contributions, we integrate three separate frameworks and apply them to a case study in a rural electric cooperative in Iowa. Through this case study, we simulate and compare hybrid power plant design and operation during two hazard events: a tornado that causes a 48-hour distribution outage and a winter weather event that causes a 6-hour generation outage. The inclusion of a hybrid power plant that leverages 1) increased battery duration and 2) advanced forecasting and dispatch strategies that reserve capacity leading up to a hazard event best reduce lost loads as well as diesel consumption that would otherwise be used to meet those loads during short- and long-duration hazard events. Depending on the hybrid power plant capacity and operation, we find that the outage mitigation value of a hybrid power plant (measured in value to customers to avoid an outage and avoided lost revenues for the utility) is significant in both hazard events; adding wind, solar, and battery assets to the existing system adds about $50-$100M in avoided lost load and at least $4-$8k in utility value in the tornado hazard event, and $570k-$2.2M in avoided lost load and at least $220-$650 in utility value in the winter hazard scenario. In both the tornado and winter hazard scenarios, optimizing the operation of the hybrid system for resilience can lend similar value as increasing battery duration by 5 MWh for the lower capacity systems considered.

17 WIND ENERGY↗

Evaluating the potential of short-term instrument deployment to improve distributed wind resource assessment

Distributed wind projects, which are connected at the distribution level of an electricity system or in off-grid applications to serve specific or local energy needs, often rely solely on wind resource models to establish wind speed and energy generation expectations. Historically, anemometer loan programs have provided an affordable avenue for more accurate onsite wind resource assessment, and the lowering cost of lidar systems has shown similar advantages for more recent assessments. While a full 12 months of onsite wind measurement is the standard for correcting model-based long-term wind speed estimates for utility-scale wind farms, the time and capital investment involved in gathering onsite measurements must be reconciled with the energy needs and funding opportunities that drive expedient deployment of distributed wind projects. Much literature exists to quantify the performance of correcting long-term wind speed estimates with 1 or more years of observational data, but few studies explore the impacts of correcting with months-long observational periods. This study aims to answer the question of how short you can go in terms of the observational time period needed to make impactful improvements to model-based long-term wind speed estimates. Three algorithms, multivariable linear regression, adaptive regression splines, and regression trees, are evaluated for their skill at correcting long-term wind resource estimates from the European Centre for Medium-Range Weather Forecasts Reanalysis version 5 (ERA5) using months-long periods of observational data from 66 locations across the US. On average, correction with even 1 month of observations provides significant improvement over the baseline ERA5 wind speed estimates and produces median bias magnitudes and relative errors within 0.22 m s −1 and 4 percentage points of the median bias magnitudes and relative errors achieved using the standard 12 months of data for correction. However, in cases when the shortest observational periods (1 to 2 months) used for correction are not well correlated with the overlapping ERA5 reference, the resultant long-term wind speed errors are worse than those produced using ERA5 without correction. Summer months, which are characterized by weaker relative wind speeds and standard deviations for most of the evaluation sites, tend to produce the worst results for long-term correction using months-long observations. The three tested algorithms perform similarly for long-term wind speed bias; however, regression trees perform notably worse than multivariable linear regression and adaptive regression splines in terms of correlation when using 6 months or less of observational data for correction. Translating the analysis to wind energy, median relative errors in the capacity factor are on average within 10 % using 1 month of training. If the observation period used for correction is not well correlated with the reference data, however, misrepresentation of the observed capacity factor can be substantial. The risk associated with poor correlation between the observed and reference datasets decreases with increasing training period length. In the worst-correlation scenarios, the median capacity factor relative errors from using 1, 3, and 6 months are within 47 %, 26 %, and 16 %, respectively.

17 WIND ENERGY↗

Interregional Renewable Energy Zones

Interregional Renewable Energy Zones (IREZs) are a component of the National Transmission Planning Study (NTPS), which analyzes strategies for building out transmission infrastructure to support decarbonizing the electricity sector by 2035. In particular, IREZs envision long-distance transmission corridors for moving large amounts of low-cost renewable energy. An IREZ is a transmission collection point that is easily accessible to a very high volume of low-cost developable wind and solar energy potential. This dataset includes 155 IREZs identified across the continental United States where each IREZ is characterized by its primary and secondary resource.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Planetary ionospheres

An analogy is drawn between the Eath's ionosphere and the existence of ionospheres around other planets or natural satellites. An ionosphere is defined as a series of layers (D, E, E1, F2) and their characteristics are discussed. Emphasis is on the role of solar wind impacting with the potential ionosphere and the subsequent chemical and diffusion processes that can be observed. Data from the MARINER and PIONEER space programs are cited concerning measured electron density and ionospheric refractivity of extraterrestrial ionospheres, then an attempt is made to model these atmospheres based on Earth ionosphere theory.

Bauer, S. J.↗

Interaction of a tethered satellite with the atmosphere and the resultant environment

The calibration of apparatus like mass spectrometers under free molecular conditions and the design and execution of relevant calibration experiments in the transition regime in low density wind tunnels is addressed. Potential access to the tethered satellite for beam instrumentation is discussed and would involve aerodynamic design input on the satellite, both as to preferred shape for the experiments and aerodynamic control for up-stream pointing. Aerodynamic design for the purpose of stabilization and pointing is also discussed.

Deleeuw, J. H.↗

A solar encounter mission - Starprobe

Accurate measurements of the internal mass distribution and dynamics of the sun as well as in situ observations of its environs are proposed through a JPL-designed satellite, STARPROBE. Scheduled for launch in 1988 under NASA's five-year plan, the probe will conduct radiometric experiments to determine the solar quadrupole moment (J2), fields-and-particles experiments (evaluating such phenomena as heating, acceleration, and peak random velocity of solar wind), and optical experiments potentially superior to those of the Earth-orbiting Solar Optical Telescope (SOT). With flight times ranging from 2.7 to 5.9 years, present delivery options comprise planetary gravity-assist trajectories that will give the spacecraft a perihelion of four solar radii at a 90 deg-inclination. Owing to science- and mission requirements, the thermal shield of the craft should tolerate a solar flux 3000 times greater than that at earth, radioisotope thermoelectric generators supplying 700 watts of power, and a three-axis stabilization system with reaction wheels providing control torque. Implementation concepts now under study may change some of the details of the design.

Randolph, J. E.↗

A comparison of theoretical and experimental pressure distributions for two advanced fighter wings

A comparison was made between experimental pressure distributions measured during testing of the Vought A-7 fighter and the theoretical predictions of four transonic potential flow codes. Isolated wind and three wing-body codes were used for comparison. All comparisons are for transonic Mach numbers and include both attached and separate flows. In general, the wing-body codes gave better agreement with the experiment than did the isolated wing code but, because of the greater complexity of the geometry, were found to be considerably more expensive and less reliable.

Haney, H. P.↗

The NASA Lewis large wind turbine program

The program is directed toward development of the technology for safe, reliable, environmentally acceptable large wind turbines that have the potential to generate a significant amount of electricity at costs competitive with conventional electric generation systems. In addition, these large wind turbines must be fully compatible with electric utility operations and interface requirements. Advances are made by gaining a better understanding of the system design drivers, improvements in the analytical design tools, verification of design methods with operating field data, and the incorporation of new technology and innovative designs. An overview of the program activities is presented and includes results from the first and second generation field machines (Mod-OA, -1, and -2), the design phase of the third generation wind turbine (Mod-5) and the advanced technology projects. Also included is the status of the Department of Interior WTS-4 machine.

Thomas, R. L.↗

Wind shear and vortex wake research in UK, 1982

A wind shear and vortex wake and their impact on aircraft were investigated. The systems and advice to help pilots, and rational scientific methods to assist in advising certification authorities and those interested in improving flight safety were developed. Wind Shear and Vortex Wakes are related, they are both invisible enemies of aircraft in the form of large disturbances in the atmosphere, both cause major accidents. Problems of building wakes at airports are is considered. Research on wind shear was initiated by the American FAA following the Boston, New York and Denver accidents to civil airliners. This resulted in: useful advice to pilots about wind shear; better attempts by the meteorologists at forecasting wind shear conditions; and useful ideas for wind shear measurement and warning systems. Three major research tasks are outstanding: (1) Worldwide measurements to give reliable estimates of probability and details of the forms of large wind shears; (2) Developments of real time wind shear measuring systems for ground or airborne use; and (3) Establishing relationships between measured wind shear and the potential hazard to an aircraft, or class of aircraft.

Alan A. Woodfield↗

The microburst - Hazard to aircraft

In encounters with microbursts, low altitude aircraft first encounter a strong headwind which increases their wing lift and altitude; this phenomenon is followed in short succession by a decreasing headwind component, a downdraft, and finally a strong tailwind that catastrophically reduces wing lift and precipitates a crash dive. It is noted that the potentially lethal low altitude wind shear of a microburst may lie in apparently harmless, rain-free air beneath a cloud base. Occasionally, such tell-tale signs as localized blowing of ground dust may be sighted in time. Microbursts may, however, occur in the heavy rain of a thunderstorm, where they will be totally obscured from view. Wind shear may be detected by an array of six anemometers and vanes situated in the vicinity of an airport, and by Doppler radar equipment at the airport or aboard aircraft.

Mccarthy, J.↗

Ultraviolet spectral morphology of the O stars. IV - The OB supergiant sequence

An atlas of 25 O3-B8 supergiant spectra in the wavelength ranges 1320-1580 A and 1620-1880 A is presented, based on high-resolution data from the IUE archives. The remarkably detailed relationship between the stellar-wind profiles and the optical spectral classifications throughout this sequence is emphasized. For instance, the (Si IV)/(C IV) ratio reverses between O4 and O6.5; and the B0, B0.5, and B0.7 Ia wind characteristics are each qualitatively unique and distinct from one another. The systematic behavior of nine stellar-wind features with ionization potentials ranging from 114 to 19 eV is summarized as a function of advancing spectral type.

Walborn, Nolan R.↗

The role of the sea-surface temperature distribution on numerically simulated cyclogenesis during ERICA

The goal was to quantify the extent to which a sea surface temperature (SST) front can influence cyclogenesis. The approach was to use the Drexel Limited-Area Mesoscale Prediction System (LAMPS) dynamical model to simulate cyclogenesis over various SST fields. Research during the past year focused on the development and testing of a four dimensional data assimilation (FDDA) technique within LAMPS. The technique is a continuous dynamical assimilation where forcing terms are added to the governing model equations to gradually nudge the model solution toward a gridded analysis. Here, the nudging is used as a dynamic initialization tool during a 12 hour preforecast to generate model balanced initial conditions for a subsequent 24 hour numerical prediction. Tests were performed to determine which variables to nudge and how to specify the four dimensional weighting function used to scale the nudging terms. To date, optimal results were obtained by nudging the u and v components of the wind along with the potential temperature. The weighting function ranged from 0 to 1 and varies in time as a quadratic polynomial. It was initialized at 0, reached its maximum at 9 hours into the preforecast, and fell back at 0 to 12 hours. The nudging terms are included in the model equations for all grid points except those within the model predicted oceanic boundary layer. This design attempts to confine changes imposed by the specified SST field to the oceanic boundary layer during the preforecast period.

Lapenta, William M.↗

Hub and pylon fairing integration for helicopter drag reduction

The results of testing hub and pylon fairings mounted on a one-fifth scale helicopter with the goal of reducing parasite drag are presented. Lift, drag, and pitching moment, as well as side force and yawing moment, were measured. The primary objective of the test was to validate the drag reduction capability of integrated hub and pylon configurations in the aerodynamic environment produced by a rotating hub in forward flight. In addition to the baseline helicopter without fairings, three hub fairings and three pylon fairings were tested in various combinations. The three hub fairings tested reflect two different conceptual design approaches to implementing an integrated fairing configuration on an actual aircraft. The design philosophy is discussed in detail and comparisons are made between the wind tunnel models and potential full-scale prototypes. The data show that model drag can be reduced by as much as 20.8 percent by combining a small hub fairing with circular arc upper and flat lower surfaces and a nontapered 34-percent thick pylon fairing. Aerodynamic effects caused by the fairings, which may have a significant impact on static longitudinal and directional stability, were observed. The results support previous research which showed that the greatest reduction in model drag is achieved if the hub and pylon fairings are integrated with minimum gap between the two.

Martin, D. M.↗