Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “water storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

T–x diagrams for the CO 2 –H 2 O system: The importance of water content in CO 2 transportation for carbon capture and storage

Abstract When water is present in a CO 2 pipeline, corrosion or plugging can occur due to the formation of liquid water or gas hydrate, respectively. Understanding how corrosion and hydrate plugging can be avoided is important for enhanced oil recovery and carbon dioxide capture and storage processes. If the CO 2 is sufficiently dried prior to transportation, the formation of these problematic free‐water phases can be avoided. In this work, isobaric T–x diagrams were developed from the P–T diagram for the CO 2 –H 2 O binary system. Pressures ranging from just below the lower quadruple point to above the lower critical end point were studied. These diagrams are meant to give the reader a better conceptual understanding of how the water composition in CO 2 –H 2 O mixtures will influence phases that form at different temperatures and pressures. The diagrams are analyzed from the perspective of flow assurance in CO 2 transportation.

Wadsworth, Lindsey A.↗

Microwave Remote Sensing and the Cold Land Processes Field Experiment

The Cold Land Processes Field Experiment (CLPX) has been designed to advance our understanding of the terrestrial cryosphere. Developing a more complete understanding of fluxes, storage, and transformations of water and energy in cold land areas is a critical focus of the NASA Earth Science Enterprise Research Strategy, the NASA Global Water and Energy Cycle (GWEC) Initiative, the Global Energy and Water Cycle Experiment (GEWEX), and the GEWEX Americas Prediction Project (GAPP). The movement of water and energy through cold regions in turn plays a large role in ecological activity and biogeochemical cycles. Quantitative understanding of cold land processes over large areas will require synergistic advancements in 1) understanding how cold land processes, most comprehensively understood at local or hillslope scales, extend to larger scales, 2) improved representation of cold land processes in coupled and uncoupled land-surface models, and 3) a breakthrough in large-scale observation of hydrologic properties, including snow characteristics, soil moisture, the extent of frozen soils, and the transition between frozen and thawed soil conditions. The CLPX Plan has been developed through the efforts of over 60 interested scientists that have participated in the NASA Cold Land Processes Working Group (CLPWG). This group is charged with the task of assessing, planning and implementing the required background science, technology, and application infrastructure to support successful land surface hydrology remote sensing space missions. A major product of the experiment will be a comprehensive, legacy data set that will energize many aspects of cold land processes research. The CLPX will focus on developing the quantitative understanding, models, and measurements necessary to extend our local-scale understanding of water fluxes, storage, and transformations to regional and global scales. The experiment will particularly emphasize developing a strong synergism between process-oriented understanding, land surface models and microwave remote sensing. The experimental design is a multi-sensor, multi-scale (1-ha to 160,000 km ^ {2}) approach to providing the comprehensive data set necessary to address several experiment objectives. A description focusing on the microwave remote sensing components (ground, airborne, and spaceborne) of the experiment will be presented.

Kim, Edward J.↗

Phenomenon Identification and Ranking Table Development for Future Application Figure-of-Merit Studies on Thermal Energy Storage Integrations with Light Water Reactors

There are no standard prioritization criteria for evaluating thermal energy storage (TES) options for use in integrated energy systems. A framework for proposing, analyzing, and presenting energy storage integration with power producers and users is presented along with a specific figure-of-merit (FOM) study based in this framework. This basis for evaluating storage technologies can provide a structure for the energy industry to analyze and prioritize energy storage in different applications and environments. The phenomena identification and ranking table (PIRT) presents a series of design questions specific to energy storage applications. The FOM study, built in this PIRT framework based on a nuclear-renewable hybrid energy system using TES to produce power and provide process energy for a secondary user, successfully identified specific technologies to use based on the project requirements. Expanding the library of projects using this framework will expand the deployable options for energy storage and increase its potential for energy security.

25 ENERGY STORAGE↗

Hydrogen Recombiner Catalyst Evaluations for Waste Storage

Radiolysis of water in nuclear waste storage generates hydrogen gas that can accumulate within sludge style waste and be rapidly released during agitation events, creating a significant flammability hazard. Engineering controls are therefore required to limit hydrogen concentrations during both quiescent storage and transient disturbances. Catalytic recombination of hydrogen in waste storage offgas is a proven mitigation strategy, maintaining hydrogen levels below flammability limits and managing sudden concentration spikes. Conventional recombiners rely on platinum and/or palladium catalysts, with development efforts focused on extending service life, increasing active surface area, and ensuring safe deployment in radioactive environments. Savannah River National Laboratory (SRNL) is evaluating a newly developed hydrogen recombiner catalyst from Canadian Nuclear Laboratories as a cost-effective and durable alternative for nuclear waste applications. Testing was conducted in SRNL’s Shielded Cells facility, which enables reduced-scale experimental modeling under radiation fields and near-use-case conditions relevant to radioactive waste storage. Catalyst performance was evaluated using a custom offgas characterization system designed for near-zero flow conditions. The experimental apparatus consisted of a gas-tight 2.7 L PTFE vessel equipped with temperature monitoring, gas flow controls, and a variable-speed mixer to simulate sludge agitation. Offgas composition was monitored using a dedicated gas chromatograph with argon carrier gas and a krypton internal standard. Measurements were obtained for an empty vessel, the vessel containing a well characterized radioactive tank waste sample, and the same configuration with the candidate catalyst installed. Results demonstrate that the new catalyst effectively reduced hydrogen concentrations in the offgas within the constraints of the experimental design. In addition to confirming catalytic activity, the testing provided valuable insights into experimental optimization and considerations for future performance evaluations. These findings support the potential scalability of the technology and highlight its applicability to broader nuclear waste management operations, offering improved safety and reduced operational costs through enhanced catalyst durability and lower replacement frequency.

Tener, Zachary P. [Savannah River National Laborat↗

Water Management Cost Assessment of CO2 Storage Operations

A three panel poster providing an analysis of treatment of produced waters from potential CO2 storage reservoirs. Selected water treatment technologies are modeled for several formations in five sedimentary basins in the lower 48 states assessing storage costs across a range of water quality present in these potential CO2 storage reservoirs.

Wendt, Anna↗

Optimize heat prosumers' economic performance under current heating price models by using water tank thermal energy storage

Due to heat prosumers' dual roles of heat producer and heat consumer, the future district heating (DH) systems will become more flexible and competitive. However, the current heating price models have not yet supported the reverse heat supply from prosumers to the central DH system, which means the prosumers would gain no economic benefit from supplying heat to the central DH system. These unidirectional heating price models will reduce interest in prosumers, and thus hinder the promotion of prosumers in DH systems. This study aimed to optimize prosumers' economic performance under the current heating price models by introducing water tank thermal energy storage (WTTES). A dynamic optimization problem was formulated to explore prosumers' economic potentials. The size parameter of WTTESs was swept in prosumers to obtain the optimal storage size considering the trade-off between the payback period and the heating cost saving. The proposed method was tested on a campus DH system in Norway. The results showed that the prosumer's annual heating cost was saved up to 9%, and the investment of WTTES could be recovered in less than ten years. This study could provide guidelines on improving prosumers' economic performance and promote the development of prosumers during the transformation period of DH systems.

Li, H↗

Special Issue of IJGGC: Nexus of Water and Carbon Capture and Storage

The mission of the Regional Carbon Sequestration Partnership (RCSP) Water Working Group (WWG) is to address stakeholder concerns regarding emerging carbon capture and storage (CCS) technology and potential interactions with local and regional water resources. As part of that mission, the WWG has been working with the International Journal of Greenhouse Gas Control (IJGGC) to develop a Special Issue dedicated to the nexus of water and CCS. Research papers were solicited, edited, and subsequently published in IJGGC. These articles were then submitted to IJGGC on December, 29, 2016, to be published online in a virtual special issue. The articles published in the virtual special issue build upon the research that has been published in IJGGC over the previous 4 years to complete a more comprehensive understanding of water issues associated with CCS.

54 ENVIRONMENTAL SCIENCES↗

Improving charge transport in integrated MoO 3 /C electrode materials for water-in-salt energy storage systems by incorporating oxygen vacancies

Improvements in the charge storage properties of α-MoO 3 used as an electrode with a 30m ZnCl 2 water-in-salt electrolyte have been achieved by enhancements in electron and ion transport enabled by an inventive synthesis route. Electron transport was improved through the integration of MoO 3 with dopamine-derived carbon via a chemical preintercalation route, and enhanced ion transport was achieved by incorporating oxygen vacancies in MoO 3 structure through ethanol 2 reduction under hydrothermal conditions. Here, the presence of carbon was confirmed by corresponding D and G bands observed in Raman spectroscopy measurements. The presence of oxygen vacancies was proven through correlated XPS, TGA, Raman spectroscopy and XRD analyses, with the introduction of oxygen vacancies leading to an expanded interlayer region. Four-point probe measurements provided evidence of increased electronic conductivity due to the incorporation of carbon, and cyclic voltammetry-based charge storage mechanism analyses revealed increases in ion transport kinetics due to oxygen vacancy formation. Tuning the oxygen vacancy concentration is critical, as excessive concentrations of these point defects leads to structural instability and poor capacity retention. This work demonstrates the combined potential of carbon and oxygen vacancies in moderate concentrations to enhance the charge storage properties of transition metal oxides. The strategies developed in this study offer a path to the development of promising materials for high-rate, high-capacity, and long-duration electrochemical energy storage technologies.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Effective Storage of Electrons in Water by the Formation of Highly Reduced Polyoxometalate Clusters

Aqueous solutions of polyoxometalates (POMs) have been shown to have potential as high-capacity energy storage materials due to their potential for multi-electron redox processes, yet the mechanism of reduction and practical limits are currently unknown. Herein, we explore the mechanism of multi-electron redox processes that allow the highly reduced POM clusters of the form {MO 3 } y to absorb y electrons in aqueous solution, focusing mechanistically on the Wells-Dawson structure X 6 [P 2 W 18 O 62 ], which comprises 18 metal centers and can uptake up to 18 electrons reversibly (y = 18) per cluster in aqueous solution when the countercations are lithium. This unconventional redox activity is rationalized by density functional theory, molecular dynamics simulations, UV-vis, electron paramagnetic resonance spectroscopy, and small-angle X-ray scattering spectra. These data point to a new phenomenon showing that cluster protonation and aggregation allow the formation of highly electron-rich meta-stable systems in aqueous solution, which produce H 2 when the solution is diluted. Finally, we show that this understanding is transferrable to other salts of [P 5 W 30 O 110 ] 15- and [P 8 W 48 O 184 ] 40- anions, which can be charged to 23 and 27 electrons per cluster, respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of different operating strategies of thermal energy storage with radiant cooling system

Thermal energy storage systems in building cooling applications have been explored extensively as a peak load-shifting technology. Thermal energy storage performance has been recognized and studied from an energy cost-savings point of view because of peak-valley price differences, but not many studies have been conducted from an energy savings viewpoint. This study experimentally investigates the performance of the energy storage-retrofitted to a ceiling-type radiant cooling system. To study the performance, a water-based storage system was designed and developed for an academic office building equipped with a radiant cooling system. The water in the storage tank was cooled to a certain storage temperature in the nighttime, and the same water was used during the daytime for meeting the cooling load. Different combinations of charging and discharging schedules were analyzed. The key objective of the study was to achieve energy savings and energy-cost savings simultaneously. This objective was accomplished by identifying the major factors contributing to the energy consumption of the storage-retrofitted cooling system and devising novel operating strategies, leading to an enhanced energy savings potential. Two operating strategies comprising 24 operating scenarios were compared and the storage was used to dispatch the load for 3 hours of the day as a full storage unit. Results showed that in hot and dry climate conditions, using the storage with the radiant cooling system offered energy savings of 3% to 14%. The energy-cost analysis was also performed using a time-of-day electricity tariff plan. The energy-cost savings varied from 17.5% to 22.4% for these operating scenarios.

25 ENERGY STORAGE↗

Energy, economic, and environmental analysis of integration of thermal energy storage into district heating systems using waste heat from data centres

Data centres produce waste heat, which can be utilized in district heating systems. However, the mismatch between data centres’ heat supply and district heating systems’ heat demands limits its utilization. Further, high peak loads increase the operation cost of district heating systems. This study aimed to solve these problems by introducing thermal energy storages. A water tank and a borehole thermal energy storage system were selected as the short-term and long-term thermal energy storage, respectively. Energy, economic, and environmental indicators were introduced to evaluate different solutions. The case study was a campus district heating system in Norway. Results showed that the water tank could shave the peak load by 31% and save the annual energy cost by 5%. The payback period was lower than 15 years when the storage efficiency remained higher than 80%. However, it had no obvious benefits in terms of mismatch relieving and CO emissions reduction. In contrast, the borehole thermal energy storage increased the waste heat utilization rate to 96% and reduced the annual CO emissions by 8%. However, the payback period was more than 17 years. These results provide guidelines for the retrofit of district heating systems, where data centres’ waste heat is available.

25 ENERGY STORAGE↗

Machine Learning Assisted Reservoir Operation Model for Long–Term Water Management Simulation

This study explores strategies for long-term reservoir simulations by combining generic rule-based reservoir management model (RMM) and machine learning (ML) models for two major multipurpose reservoirs — Allatoona Lake and Lake Sidney Lanier in the southeastern United States. First, a standalone RMM is developed to simulate daily release and storage during Water Year 1981–2015. Next, using Long-Short Term Memory (LSTM) as the ML technique, a standalone LSTM model is trained based on reservoir inflow and meteorological observations to simulate reservoir release and estimate reservoir storage through water balance calculation. Three hybrid modeling strategies are developed, one using RMM output as an additional LSTM input (H1), another using LSTM as the initial release estimate in RMM (H2), and the third combining the first two strategies (H3). The Nash–Sutcliffe efficiency (NSE) for release (NSE-r), storage (NSE-s), and their mean (NSE-avg) are used for model evaluation. Overall, H1 improves NSE-r to 0.65 and 0.54 for Allatoona and Lanier, respectively, compared to standalone RMM (0.44 and 0.21); however, its storage trajectory did not produce a physically feasible solution, similar to LSTM. H2 and especially H3 show that they can retain the best features from RMM and LSTM, with H3 NSE-avg being 0.695 and 0.55 for Allatoona and Lanier outperforming RMM (0.615 and 0.29). In conclusion, the findings suggest a robust simulation capacity for large-scale water management in future studies.

54 ENVIRONMENTAL SCIENCES↗

LARGO hot water system thermal performance test report

The thermal performance tests and results on the LARGO Solar Hot Water System under natural environmental conditions is presented. Some objectives of these evaluations are to determine the amount of energy collected, the amount of energy delivered to the household as contributed by solar power supplied to operate the system and auxiliary power to maintain tank temperature at proper level, overall system efficiency and to determine temperature distribution within the tank. The Solar Hot Water system is termed a Dump-type because of the draining system for freeze protection. The solar collector is a single glazed flat plate. An 82-gallon domestic water heater is provided as the energy storage vessel. Water is circulated through the collector and water heater by a 5.3 GPM capacity pump, and control of the pump motor is achieved by a differential temperature controller.

Source record↗

Medium-temperature phase change material integration in domestic heat pump water heaters for improved thermal energy storage

In this review, we examine state-of-the-art developments in integrating phase change materials (PCMs) for thermal energy storage (TES) in domestic heat pump water heaters (HPWHs). The component design optimization and control optimization of HPWHs and TES are reviewed for insight into improving the thermal capacity and efficiency of a PCM-integrated HPWH. The state-of-the-art review is categorized by the stage of development of the PCM for deployment in HPWHs. To select appropriate PCMs for HPWHs, a six-factor down-selection process is used to determine the best material(s) for integration in HPWHs with appropriate heat exchanger design. Ultimately, food-grade PCMs appear to be the best candidate for integration of TES in domestic HPWHs because they are nontoxic, highly cyclable, and have heat transfer properties accommodable to water heating when integrated in a manner to overcome the thermal conductivity limitations of the material. A key parameter of water heating performance is thermal heating power of the PCM component, which is not often reported. Many studies report significant improvement in capacity and efficiency. Furthermore, many performance metrics are identified from the literature to quantify the system performance, but agreement across studies is not found. Unified energy factor and first hour rating performance tests are required for commercially available HPWHs, and these performance metrics could homogenize the literature. Ultimately, we find that select PCMs are ready for deployment with HPWHs for performance improvement, and component design and control optimizations are new avenues of research and development required for a commercially viable PCM-integrated HPWH system.

25 ENERGY STORAGE↗

Effects of film thickness on electrochemical properties of nanoscale polyethylenedioxythiophene (PEDOT) thin films grown by oxidative molecular layer deposition (oMLD)

Poly(3,4-ethylene dioxythiophene) (PEDOT) has a high theoretical charge storage capacity, making it of interest for electrochemical applications including energy storage and water desalination. Nanoscale thin films of PEDOT are particularly attractive for these applications to enable faster charging. Recent work has demonstrated that nanoscale thin films of PEDOT can be formed using sequential gas-phase exposures via oxidative molecular layer deposition, or oMLD, which provides advantages in conformality and uniformity on high aspect ratio substrates over other deposition techniques. But to date, the electrochemical properties of these oMLD PEDOT thin films have not been well-characterized. In this work, we examine the electrochemical properties of 5–100 nm thick PEDOT films formed using 20–175 oMLD deposition cycles. We find that film thickness of oMLD PEDOT films affects the orientation of ordered domains leading to a substantial change in charge storage capacity. Interestingly, we observe a minimum in charge storage capacity for an oMLD PEDOT film thickness of ~30 nm (60 oMLD cycles at 150 °C), coinciding with the highest degree of face-on oriented PEDOT domains as measured using grazing incidence wide angle X-ray scattering (GIWAXS). Thinner and thicker oMLD PEDOT films exhibit higher fractions of oblique (off-angle) orientations and corresponding increases in charge capacity of up to 120 mA h g -1 . Electrochemical measurements suggest that higher charge capacity in films with mixed domain orientation arise from the facile transport of ions from the liquid electrolyte into the PEDOT layer. Greater exposure of the electrolyte to PEDOT domain edges is posited to facilitate faster ion transport in these mixed domain films. In conclusion, these insights will inform future design of PEDOT coated high-aspect ratio structures for electrochemical energy storage and water treatment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Storage and recycling of water and carbon dioxide in the earth

The stabilities and properties of water- and carbon-bearing phases in the earth have been determined from phase equilibrium measurements, combined with new data on the equations of state of water, carbon dioxide, carbonates and hydrates. The data have then been used to predict the fate of calcite and hydrous phases in subducting oceanic lithosphere. From the compositions of MORB's one can estimate concentrations of water and carbon of around 200 ppm and 80 ppm respectively in the upper mantle. Lower mantle estimates are very uncertain, but 1900 ppm water and 2000 ppm C are plausible concentrations. Measurements of the density of supercritical water to 3 GPa demonstrate that this phase is less compressible than anticipated from the equations of state of Haar et al. or Saul and Wagner and is closer to predictions based on molecular dynamics simulations. Conversely, fugacity measurements on carbon dioxide to 7 GPa show that this fluid is more compressible than predicted from the MRK equation of state. The results imply that hydrates are relatively more stable and carbonates less stable at pressures greater than 5 GPa than would be predicted from simple extrapolation of the low pressure data. Nevertheless, carbonates remain extremely refractory phases within both the upper and lower mantle.

Wood, Bernard J.↗

Methyl jasmonate effects on sugarbeet root responses to postharvest dehydration

Background: Sugarbeet (Beta vulgaris L.) roots are stored under conditions that cause roots to dehydrate, which increases postharvest losses. Although exogenous jasmonate applications can reduce drought stress in intact plants, their ability to alleviate the effects of dehydration in postharvest sugarbeet roots or other stored plant products is unknown. Research was conducted to determine whether jasmonate treatment could mitigate physiological responses to dehydration in postharvest sugarbeet roots. Methods: Freshly harvested sugarbeet roots were treated with 10 µM methyl jasmonate (MeJA) or water and stored under dehydrating and non-dehydrating storage conditions. Changes in fresh weight, respiration rate, wound healing, leaf regrowth, and proline metabolism of treated roots were investigated throughout eight weeks in storage. Results: Dehydrating storage conditions increased root weight loss, respiration rate, and proline accumulation and prevented leaf regrowth from the root crown. Under dehydrating conditions, MeJA treatment reduced root respiration rate, but only in severely dehydrated roots. MeJA treatment also hastened wound-healing, but only in the late stages of barrier formation. MeJA treatment did not impact root weight loss or proline accumulation under dehydrating conditions or leaf regrowth under non-dehydrating conditions. Both dehydration and MeJA treatment affected expression of genes involved in proline metabolism. In dehydrated roots, proline dehydrogenase expression declined 340-fold, suggesting that dehydration-induced proline accumulation was governed by reducing proline degradation. MeJA treatment altered proline biosynthetic and catabolic gene expression, with greatest effect in nondehydrated roots. Overall, MeJA treatment alleviated physiological manifestations of dehydration stress in stored roots, although the beneficial effects were small. Postharvest jasmonate applications, therefore, are unlikely to significantly reduce dehydrationrelated storage losses in sugarbeet roots.

54 ENVIRONMENTAL SCIENCES↗