Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “volume visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Modeling fuels and fire effects in 3D: Model description and applications

Scientists and managers critically need ways to assess how fuel treatments alter fire behavior, yet few tools currently exist for this purpose. In this work, we present a spatially-explicit-fuel-modeling system, FuelManager, which models fuels, vegetation growth, fire behavior (using a physics-based model, FIRETEC), and fire effects. FuelManager's flexible approach facilitates modeling fuels across a wide range of detail. Large trees or shrubs with specific coordinates are modeled as individual “Plants”, while understory plants are modeled as collections of plants called “LayerSets”. Both Plants and LayerSets contain various fuel particles (leaves, needles, twigs) with various properties including shape, size and surface area to volume ratio. A wide range of vegetation and treatments can be modeled, analyzed quantitatively and visualized in a 3D viewer. We describe the modeling approach and demonstrate fuel modeling at different levels of detail, fuel treatment and fire effects capabilities. Lastly, detailed model equations are provided in the Appendices.

54 ENVIRONMENTAL SCIENCES↗

A Semi-Supervised Learning Method for the Identification of Bad Exposures in Large Imaging Surveys

As the data volume of astronomical imaging surveys rapidly increases, traditional methods for image anomaly detection, such as visual inspection by human experts, are becoming impractical. We introduce a machine-learning-based approach to detect poor-quality exposures in large imaging surveys, with a focus on the DECam Legacy Survey (DECaLS) in regions of low extinction (i.e., E ( B − V ) < 0.04 ). Our semi-supervised pipeline integrates a vision transformer (ViT), trained via self-supervised learning (SSL), with a k-Nearest Neighbor (kNN) classifier. We train and validate our pipeline using a small set of labeled exposures observed by surveys with the Dark Energy Camera (DECam). A clustering-space analysis of where our pipeline places images labeled in good and bad categories suggests that our approach can efficiently and accurately determine the quality of exposures. Applied to new imaging being reduced for DECaLS Data Release 11, our pipeline identifies 780 problematic exposures, which we subsequently verify through visual inspection. Being highly efficient and adaptable, our method offers a scalable solution for quality control in other large imaging surveys.

Luo, Yufeng (ORCID:0000000246230683)↗

Cloud Giovanni: Reining in Costs and Improving Performance with Analytical Data Stores Using Scalable Serverless Architecture

Giovanni is the Geospatial Interactive Online Visualization ANd aNalysis Infrastructure developed at NASA GES DISC which provides a simple and intuitive way to visualize, analyze, and access vast amounts of Earth science data. It receives large number of user requests each day for a variety of analysis and visualization services, which leads to the big data challenge of serving gradually increasing large data volumes with diverse statistical algorithms. We hereby propose a multi-dimensional accumulation method which provides fast and cost-efficient cloud analysis for diverse services including both area averaging and time averaging. This method involves the weighted volume integration over multiple variable dimensions (time and space), and is implemented in AWS using Athena providing serverless and highly scalable data analysis. Compared to the standard method, this approach dramatically reduced the computational time by order of magnitude with a minimal AWS cost incurred. For example, for a benchmark of 10-year area averaging over the 1x1 degree daily variable, the computational time was reduced from minutes to seconds, and the Athena cost is only $5 for 100,000 requests.

Zhang, Hailiang↗

Management of Operations under Visual Flight Rules in UTM for Disaster Response Missions

The disaster response domain has experienced an increased focus in recent years due to the rise in number and scale of events, lessons learned from past experience, and emerging technologies that make possible a more coordinated and effective response. As part of this focus, JAXA and NASA have been collaborating on the integration of manned and unmanned aircraft in support of disaster response operations through integrated testing of their respective mission planning and optimization system (Disaster Relief Aircraft Information Sharing Network, or D-NET) and an automated UAS traffic management system (e.g., UTM). In 2018, JAXA and NASA jointly participated in a large-scale disaster drill in Japan where the integration of systems was successfully demonstrated through real-time data exchanges, visualization, and decision making as part of the coordinated airspace management of a manned helicopter in VFR conditions and unmanned small UAS operating in common areas. This work details a flight test consisting of two flights that were conducted December 2019 near the Chofu Aerodrome in Tokyo, which focused on the evaluation of pilots operating under Visual Flight Rules (VFR) communicating through D-NET and sharing intent and position information within UTM. This work contributes to defining the necessary requirements for digital coordination between manned and unmanned operations. UTM requires the use of operation volumes, which are spatial and temporal volumes that encompass UAS flight trajectories and account for technical performance errors and deviations due to disturbances (e.g., wind). A series of flights, representing different missions, used landmark-based operation volumes and conformance of the aircraft to those operation volumes were tracked within UTM. Experienced disaster response helicopter pilots provided insight on the development of the operation plans and their usability during disaster response operations. Results from the flight test supported the suggested benefits of using landmarks for planning and positional awareness and highlighted the need for future research in advanced visualization capabilities to support operations that consider both system constraints and flight deck/airspace management interaction.

disaster response↗

Tools for Analysis and Visualization of Large Time-Varying CFD Data Sets

In the second year, we continued to built upon and improve our scanline-based direct volume renderer that we developed in the first year of this grant. This extremely general rendering approach can handle regular or irregular grids, including overlapping multiple grids, and polygon mesh surfaces. It runs in parallel on multi-processors. It can also be used in conjunction with a k-d tree hierarchy, where approximate models and error terms are stored in the nodes of the tree, and approximate fast renderings can be created. We have extended our software to handle time-varying data where the data changes but the grid does not. We are now working on extending it to handle more general time-varying data. We have also developed a new extension of our direct volume renderer that uses automatic decimation of the 3D grid, as opposed to an explicit hierarchy. We explored this alternative approach as being more appropriate for very large data sets, where the extra expense of a tree may be unacceptable. We also describe a new approach to direct volume rendering using hardware 3D textures and incorporates lighting effects. Volume rendering using hardware 3D textures is extremely fast, and machines capable of using this technique are becoming more moderately priced. While this technique, at present, is limited to use with regular grids, we are pursuing possible algorithms extending the approach to more general grid types. We have also begun to explore a new method for determining the accuracy of approximate models based on the light field method described at ACM SIGGRAPH '96. In our initial implementation, we automatically image the volume from 32 equi-distant positions on the surface of an enclosing tessellated sphere. We then calculate differences between these images under different conditions of volume approximation or decimation. We are studying whether this will give a quantitative measure of the effects of approximation. We have created new tools for exploring the differences between images produced by various rendering methods. Images created by our software can be stored in the SGI RGB format. Our idtools software reads in pair of images and compares them using various metrics. The differences of the images using the RGB, HSV, and HSL color models can be calculated and shown. We can also calculate the auto-correlation function and the Fourier transform of the image and image differences. We will explore how these image differences compare in order to find useful metrics for quantifying the success of various visualization approaches. In general, progress was consistent with our research plan for the second year of the grant.

Wilhelms, Jane↗

TU-F-17A-01: BEST IN PHYSICS (JOINT IMAGING-THERAPY) - An Automatic Toolkit for Efficient and Robust Analysis of 4D Respiratory Motion

Purpose: To provide an automatic image analysis toolkit to process thoracic 4-dimensional computed tomography (4DCT) and extract patient-specific motion information to facilitate investigational or clinical use of 4DCT. Methods: We developed an automatic toolkit in MATLAB to overcome the extra workload from the time dimension in 4DCT. This toolkit employs image/signal processing, computer vision, and machine learning methods to visualize, segment, register, and characterize lung 4DCT automatically or interactively. A fully-automated 3D lung segmentation algorithm was designed and 4D lung segmentation was achieved in batch mode. Voxel counting was used to calculate volume variations of the torso, lung and its air component, and local volume changes at the diaphragm and chest wall to characterize breathing pattern. Segmented lung volumes in 12 patients are compared with those from a treatment planning system (TPS). Voxel conversion was introduced from CT# to other physical parameters, such as gravity-induced pressure, to create a secondary 4D image. A demon algorithm was applied in deformable image registration and motion trajectories were extracted automatically. Calculated motion parameters were plotted with various templates. Machine learning algorithms, such as Naive Bayes and random forests, were implemented to study respiratory motion. This toolkit is complementary to and will be integrated with the Computational Environment for Radiotherapy Research (CERR). Results: The automatic 4D image/data processing toolkit provides a platform for analysis of 4D images and datasets. It processes 4D data automatically in batch mode and provides interactive visual verification for manual adjustments. The discrepancy in lung volume calculation between this and the TPS is <±2% and the time saving is by 1–2 orders of magnitude. Conclusion: A framework of 4D toolkit has been developed to analyze thoracic 4DCT automatically or interactively, facilitating both investigational and clinical use. More software tools are under development for automatic analysis of other 4D imaging modalities. This research is in part supported by NIH (U54CA137788/132378) and City Seed FY13(Grant No. 93348-14 01). AY would like to thank MSKCC summer medical student research program supported by National Cancer Institute and hosted by Department of Medical Physics at MSKCC.

60 APPLIED LIFE SCIENCES↗

Ultrascale Visualization of Climate Data

Fueled by exponential increases in the computational and storage capabilities of high-performance computing platforms, climate simulations are evolving toward higher numerical fidelity, complexity, volume, and dimensionality. These technological breakthroughs are coming at a time of exponential growth in climate data, with estimates of hundreds of exabytes by 2020. To meet the challenges and exploit the opportunities that such explosive growth affords, a consortium of four national laboratories, two universities, a government agency, and two private companies formed to explore the next wave in climate science. Working in close collaboration with domain experts, the Ultrascale Visualization Climate Data Analysis Tools (UV-CDAT) project aims to provide high-level solutions to a variety of climate data analysis and visualization problems.

analysis tools↗

THE RELATION BETWEEN GAS AND DUST IN THE TAURUS MOLECULAR CLOUD

We report a study of the relation between dust and gas over a 100 deg{sup 2} area in the Taurus molecular cloud. We compare the H{sub 2} column density derived from dust extinction with the CO column density derived from the {sup 12}CO and {sup 13}CO J = 1 {yields} 0 lines. We derive the visual extinction from reddening determined from 2MASS data. The comparison is done at an angular size of 200'' corresponding to 0.14 pc at a distance of 140 pc. We find that the relation between visual extinction A{sub V} and N(CO) is linear between A{sub V} {approx_equal} 3 and 10 mag in the region associated with the B213-L1495 filament. In other regions, the linear relation is flattened for A{sub V{approx}}> 4 mag. We find that the presence of temperature gradients in the molecular gas affects the determination of N(CO) by {approx}30%-70% with the largest difference occurring at large column densities. Adding a correction for this effect and accounting for the observed relation between the column density of CO and CO{sub 2} ices and A{sub V}, we find a linear relationship between the column of carbon monoxide and dust for observed visual extinctions up to the maximum value in our data {approx_equal}23 mag. We have used these data to study a sample of dense cores in Taurus. Fitting an analytical column density profile to these cores we derive an average volume density of about 1.4 x 10{sup 4} cm{sup -3} and a CO depletion age of about 4.2 x 10{sup 5} yr. At visual extinctions smaller than {approx}3 mag, we find that the CO fractional abundance is reduced by up to two orders of magnitude. The data show a large scatter suggesting a range of physical conditions of the gas. We estimate the H{sub 2} mass of Taurus to be about 1.5 x 10{sup 4} M{sub sun}, independently derived from the A{sub V} and N(CO) maps. We derive a CO integrated intensity to H{sub 2} conversion factor of about 2.1 x 10{sup 20} cm{sup -2} (K km s{sup -1}){sup -1}, which applies even in the region where the [CO]/[H{sub 2}] ratio is reduced by up to two orders of magnitude. The distribution of column densities in our Taurus maps resembles a log-normal function but shows tails at large and low column densities. The length scale at which the high column density tail starts to be noticeable is about 0.4 pc.

79 ASTRONOMY AND ASTROPHYSICS↗

Topological Cacti: Visualizing Contour-based Statistics

Contours, the connected components of level sets, play an important role in understanding the global structure of a scalar field. In particular their nestingbehavior and topology-often represented in form of a contour tree-have been used extensively for visualization and analysis. However, traditional contour trees onlyencode structural properties like number of contours or the nesting of contours, but little quantitative information such as volume or other statistics. Here we use thesegmentation implied by a contour tree to compute a large number of per-contour (interval) based statistics of both the function defining the contour tree as well asother co-located functions. We introduce a new visual metaphor for contour trees, called topological cacti, that extends the traditional toporrery display of acontour tree to display additional quantitative information as width of the cactus trunk and length of its spikes. We apply the new technique to scalar fields ofvarying dimension and different measures to demonstrate the effectiveness of the approach.

97 MATHEMATICS AND COMPUTING↗

Volumetric Density-Equalizing Reference Map with Applications

The density-equalizing map, a technique developed for cartogram creation, has been widely applied to data visualization but only for 2D applications. Here, we propose a novel method called the volumetric density-equalizing reference map (VDERM) for computing density-equalizing map for volumetric domains. Given a prescribed density distribution in a volumetric domain in $\mathbb{R}^3$, the proposed method continuously deforms the domain, with different volume elements enlarged or shrunk according to the density distribution. With the aid of the proposed method, medical and sociological data can be visualized via deformations of 3D objects. The method can also be applied to adaptive remeshing and shape modeling. Furthermore, by exploiting the time-dependent nature of the proposed method, applications to shape morphing can be easily achieved. Experimental results are presented to demonstrate the effectiveness of the proposed method.

97 MATHEMATICS AND COMPUTING↗

Predictive Parameters of CyberKnife Fiducial-less (XSight Lung) Applicability for Treatment of Early Non-Small Cell Lung Cancer: A Single-Center Experience

Purpose: To determine which parameters allow for CyberKnife fiducial-less tumor tracking in stereotactic body radiation therapy (SBRT) for early-stage non-small cell lung cancer. Methods and Materials: A total of 133 lung SBRT patients were preselected for direct soft-tissue tracking based on manufacturer recommendations (peripherally located tumors ≥1.5 cm with a dense appearance) and staff experience. Patients underwent a tumor visualization test to verify adequate detection by the tracking system (orthogonal radiographs). An analysis of potential predictors of successful tumor tracking was conducted looking at: tumor stage, size, histology, tumor projection on the vertebral column or mediastinum, distance to the diaphragm, lung-to-soft tissue ratio, and patient body mass index. Results: Tumor visualization was satisfactory for 88 patients (66%) and unsatisfactory for 45 patients (34%). Median time to treatment start was 6 days in the success group (range, 2-18 days) and 15 days (range, 3-63 days) in the failure group. A stage T2 (P=.04), larger tumor size (volume of 15.3 cm{sup 3} vs 6.5 cm{sup 3} in success and failure group, respectively) (P<.0001), and higher tumor density (0.86 g/cm{sup 3} vs 0.79 g/cm{sup 3}) were predictive of adequate detection. There was a 63% decrease in failure risk with every 1-cm increase in maximum tumor dimension (relative risk for failure = 0.37, CI=0.23-0.60, P=.001). A diameter of 3.6 cm predicted a success probability of 80%. Histology, lung-to-soft tissue ratio, distance to diaphragm, patient's body mass index, and tumor projection on vertebral column and mediastinum were not found to be predictive of success. Conclusions: Tumor size, volume, and density were the most predictive factors of a successful XSight Lung tumor tracking. Tumors >3.5 cm have ≥80% chance of being adequately visualized and therefore should all be considered for direct tumor tracking.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-time data-intensive computing

Today users visit synchrotrons as sources of understanding and discovery—not as sources of just light, and not as sources of data. To achieve this, the synchrotron facilities frequently provide not just light but often the entire end station and increasingly, advanced computational facilities that can reduce terabytes of data into a form that can reveal a new key insight. The Advanced Light Source (ALS) has partnered with high performance computing, fast networking, and applied mathematics groups to create a “super-facility”, giving users simultaneous access to the experimental, computational, and algorithmic resources to make this possible. This combination forms an efficient closed loop, where data—despite its high rate and volume—is transferred and processed immediately and automatically on appropriate computing resources, and results are extracted, visualized, and presented to users or to the experimental control system, both to provide immediate insight and to guide decisions about subsequent experiments during beamtime. We will describe our work at the ALS ptychography, scattering, micro-diffraction, and micro-tomography beamlines.

43 PARTICLE ACCELERATORS↗

SU-E-J-109: Evaluation of Deformable Accumulated Parotid Doses Using Different Registration Algorithms in Adaptive Head and Neck Radiotherapy

Purpose: Three deformable image registration (DIR) algorithms are utilized to perform deformable dose accumulation for head and neck tomotherapy treatment, and the differences of the accumulated doses are evaluated. Methods: Daily MVCT data for 10 patients with pathologically proven nasopharyngeal cancers were analyzed. The data were acquired using tomotherapy (TomoTherapy, Accuray) at the PLA General Hospital. The prescription dose to the primary target was 70Gy in 33 fractions.Three DIR methods (B-spline, Diffeomorphic Demons and MIMvista) were used to propagate parotid structures from planning CTs to the daily CTs and accumulate fractionated dose on the planning CTs. The mean accumulated doses of parotids were quantitatively compared and the uncertainties of the propagated parotid contours were evaluated using Dice similarity index (DSI). Results: The planned mean dose of the ipsilateral parotids (32.42±3.13Gy) was slightly higher than those of the contralateral parotids (31.38±3.19Gy)in 10 patients. The difference between the accumulated mean doses of the ipsilateral parotids in the B-spline, Demons and MIMvista deformation algorithms (36.40±5.78Gy, 34.08±6.72Gy and 33.72±2.63Gy ) were statistically significant (B-spline vs Demons, P<0.0001, B-spline vs MIMvista, p =0.002). And The difference between those of the contralateral parotids in the B-spline, Demons and MIMvista deformation algorithms (34.08±4.82Gy, 32.42±4.80Gy and 33.92±4.65Gy ) were also significant (B-spline vs Demons, p =0.009, B-spline vs MIMvista, p =0.074). For the DSI analysis, the scores of B-spline, Demons and MIMvista DIRs were 0.90, 0.89 and 0.76. Conclusion: Shrinkage of parotid volumes results in the dose increase to the parotid glands in adaptive head and neck radiotherapy. The accumulated doses of parotids show significant difference using the different DIR algorithms between kVCT and MVCT. Therefore, the volume-based criterion (i.e. DSI) as a quantitative evaluation of registration accuracy is essential besides the visual assessment by the treating physician. This work was supported in part by the grant from Chinese Natural Science Foundation (Grant No. 11105225)

60 APPLIED LIFE SCIENCES↗

Turbulent Processes that Influence Boundary-Layer Cloud Structure (Final Technical Report)

Many models of the atmosphere simulate vertical profiles of observable fields, such as temperature, moisture, and vertical velocity. To assess the realism of such model output, it is important to evaluate the modeled profiles against observations. However, many extant evaluations consist of comparing time averaged profiles from the model and the observations. Such time averages can smooth out unrealistic features that appear in instantaneous profiles. In this way, the time averages may obscure certain model errors from detection. For instance, many models misrepresent turbulent processes, leading to profiles that are too smoothed out or too noisy. E.g., if a model has coarse vertical resolution and overly strong diffusion, then the model may be unable to produce observed sharp peaks. On the other hand, a model may have artificial approximations that produce spurious jumps in the vertical. Much can be learned by browsing through instantaneous snapshots of model output. But the volume of output produced by a global model is far too great to rely purely on visual inspection. In addition, we need a way to statistically characterize the profiles, so that anomalies can be detected more conveniently.

54 ENVIRONMENTAL SCIENCES↗

Wavelet-Based Interpolation and Representation of Non-Uniformly Sampled Spacecraft Mission Data

A well-documented problem in the analysis of data collected by spacecraft instruments is the need for an accurate, efficient representation of the data set. The data may suffer from several problems, including additive noise, data dropouts, an irregularly-spaced sampling grid, and time-delayed sampling. These data irregularities render most traditional signal processing techniques unusable, and thus the data must be interpolated onto an even grid before scientific analysis techniques can be applied. In addition, the extremely large volume of data collected by scientific instrumentation presents many challenging problems in the area of compression, visualization, and analysis. Therefore, a representation of the data is needed which provides a structure which is conducive to these applications. Wavelet representations of data have already been shown to possess excellent characteristics for compression, data analysis, and imaging. The main goal of this project is to develop a new adaptive filtering algorithm for image restoration and compression. The algorithm should have low computational complexity and a fast convergence rate. This will make the algorithm suitable for real-time applications. The algorithm should be able to remove additive noise and reconstruct lost data samples from images.

Bose, Tamal↗

A simple method for quantitating the propensity for calcium oxalate crystallization in urine

To assess the propensity for spontaneous crystallization of calcium oxalate in urine, the permissible increment in oxalate is calculated. The previous method required visual observation of crystallization with the addition of oxalate, this warranted the need for a large volume of urine and a sacrifice in accuracy in defining differences between small incremental changes of added oxalate. Therefore, this method has been miniaturized and spontaneous crystallization is detected from the depletion of radioactive oxalate. The new "micro" method demonstrated a marked decrease (p < 0.001) in the permissible increment in oxalate in urine of stone formers versus normal subjects. Moreover, crystallization inhibitors added to urine, in vitro (heparin or diphosphonate) or in vivo (potassium citrate administration), substantially increased the permissible increment in oxalate. Thus, the "micro" method has proven reliable and accurate in discriminating stone forming from control urine and in distinguishing changes of inhibitory activity.

NASA Discipline Regulatory Physiology↗

HEALPix: A Framework for High-Resolution Discretization and Fast Analysis of Data Distributed on the Sphere

HEALPix the Hierarchical Equal Area isoLatitude Pixelization is a versatile structure for the pixelization of data on the sphere. An associated library of computational algorithms and visualization software supports fast scientific applications executable directly on discretized spherical maps generated from very large volumes of astronomical data. Originally developed to address the data processing and analysis needs of the present generation of cosmic microwave background experiments (e.g., BOOMERANG, WMAP), HEALPix can be expanded to meet many of the profound challenges that will arise in confrontation with the observational output of future missions and experiments, including, e.g., Planck, Herschel, SAFIR, and the Beyond Einstein inflation probe. In this paper we consider the requirements and implementation constraints on a framework that simultaneously enables an efficient discretization with associated hierarchical indexation and fast analysis/synthesis of functions defined on the sphere. We demonstrate how these are explicitly satisfied by HEALPix.

cosmic microwave background↗

Generation of Parametric Equivalent-Area Targets for Design of Low-Boom Supersonic Concepts

A tool with an Excel visual interface is developed to generate equivalent-area (A(sub e)) targets that satisfy the volume constraints for a low-boom supersonic configuration. The new parametric Ae target explorer allows users to interactively study the tradeoffs between the aircraft volume constraints and the low-boom characteristics (e.g., loudness) of the ground signature. Moreover, numerical optimization can be used to generate the optimal A(sub e) target for given A(sub e) volume constraints. A case study is used to demonstrate how a generated low-boom Ae target can be matched by a supersonic configuration that includes a fuselage, wing, nacelle, pylon, aft pod, horizontal tail, and vertical tail. The low-boom configuration is verified by sonic-boom analysis with an off-body pressure distribution at three body lengths below the configuration

Li, Wu↗