Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage prediction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

An improved push-pull voltage fed converter using a tapped output-filter inductor

A new concept of using a tapped output-filter inductor and an auxiliary commutating diode to reduce the likelihood of transformer core saturation in a push-pull, voltage-fed converter is presented. The linearized circuit model and transfer functions are derived with a hybrid approach using both state-space and circuit averaging. Operation of the new converter - including parasitic effects - is discussed, and a design equation for inductor tap ratio is established. It is predicted and experimentally confirmed that the new converter has more symmetrical transformer core operation, and the potential exits for lower transistor turnon current and reduced transistor voltage stress. These benefits reduce switching loss and enhance transistor reliability.

Wester, G. W.↗

A DC Transformer

A component level dc transformer is described in which no alternating currents or voltages are present. It operates by combining features of a homopolar motor and a homopolar generator, both de devices, such that the output voltage of a de power supply can be stepped up (or down) with a corresponding step down (or up) in current. The basic theory for this device is developed, performance predictions are made, and the results from a small prototype are presented. Based on demonstrated technology in the literature, this de transformer should be scalable to low megawatt levels, but it is more suited to high current than high voltage applications. Significant development would be required before it could achieve the kilovolt levels needed for de power transmission.

Youngquist, Robert C.↗

Spatially Resolved Performance Analysis for Perovskite Solar Cells

This review explores the current state of the art in spatially resolved characterization of mixed-halide perovskite solar cells. As the size of perovskite cells and modules continues to grow, quantification of the spatial distribution of key cell parameters will become increasingly valuable in predicting ultimate cell-level performance and tracking process homogeneity. Here, both high resolution microscopic approaches using scanning techniques and camera-based methods for full-area cell and/or module analysis are discussed. The value of this local data in predicting performance losses at the cell level is particularly emphasized. Measurable physical parameters sensitive to losses of voltage, current, fill factor, and efficiency are discussed together with selected experimental results. It is demonstrated that a combination of spatially resolved cell parameter mapping/imaging can be used to quantitatively discriminate various loss contributions at high resolution. The impact and control of inhomogeneities become particularly important when upscaling from small devices to large formats compatible with industrial mass production.

14 SOLAR ENERGY↗

Design of High Power Density 100 kW Surface Permanent Magnet Machine with No Heavy Rare Earth Material Using Current Source Inverter for Traction Application

Surface permanent magnet (SPM) machines are appealing candidates for traction applications because of high power density and high efficiency. Rare-earth magnets deliver high performance but raise concerns about material supply dependability, particularly if they use heavy rare-earth materials. This paper presents the design of a high-performance SPM machine without any heavy rare-earth material that is optimized specifically for a current-source inverter (CSI) traction drive. This machine is designed for a constant-power speed ratio (CPSR) of 3. A genetic algorithm has been performed to achieve a target of 50 kW/L active power density at speeds up to 20,000 rpm. Operation at a peak line-to-line voltage of 800 V can be achieved using 1200 V power devices with a safety margin. The predicted electromagnetic and rotor structural performance characteristics are presented using both analytical and finite element analysis (FEA) results.

(CPSR)↗

Dopant Optimization of Donors in Semiconductor Opening Switches to Eliminate Prepulse

Semiconductor opening switches are solid-state devices capable of delivering nanosecond, hundreds of kilovolts pulses by interrupting kiloamps of current. The interruption of the current occurs in a moderately doped p-region when a high electric field region (HFR) is formed. The HFR occurs because the reverse pumping current cannot be supported by the saturation velocity and majority carrier concentration of the doping level. However, the donor profile also significantly affects the pulse performance. A secondary prepulse occurs if a secondary HFR is formed at the interface of the background n-doping and N+ doping (X n ) . By moving the location of X n deeper into the diode, the effect of the prepulse is reduced. This article investigates the effect of the donor doping profile on the performance metrics of semiconductor opening switches through technology computer-aided design (TCAD) simulations and experimental results. Through a SILVACO TCAD optimization, we designed a P + /p/n - base/n/N + where the intersection of the moderate p-region and intrinsic n-base region (X p ) is at 160 μm and X n is at 220 μm. This profile is fabricated via silicon epitaxy. Experimentally, it is shown that a deep X n (220 μm) compared with a shallow X n (300 μm) reduces the rise time by >5× . In addition, the magnitude of current density during interruption affects the prepulse foot and pulse shape. At lower current densities without the graded donor profile, high peak voltages are not achieved. Comparing the experimental results to the TCAD simulations shows that the model is predictive under high-current densities in the semiconductor opening switch (SOS) regime.

nanosecond pulse power↗

HERMES 2019 Upgrade Characterization - Quick Look Report (UUR)

Characterizing the electromagnetic environment created by the recently upgraded HERMES III pulser is the primary objective addressed by this report. The pulser upgrade design was intended not only to provide higher electric field and magnetic field illumination amplitudes but also to provide a more collimated beam, focused along the center-line of the courtyard. For high-voltage pulsers to be useful as qualification systems, they must have the requisite peak values and uniform, predictable peak field spatial patterns. To assess the peak electric field values and uniformity of the spatial pattern of the electric fields for the upgraded HERMES system, a 1 6 full-power shot illumination of 9 electric and 9 magnetic field sensors in the courtyard of the HERMES III facility was conducted. The data acquired from this test showed an increase an increase in electric field amplitude, but still an asymmetry in the spatial distributions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Designing Hydropower Flows to Balance Energy and Environmental Needs (HydroWIRES Topic A Final Project Report)

Hydropower is expected to play a new role in the US electricity grid as more variable renewable energy sources like wind and solar come online. Wind and solar generation increase fluctuations in electrical supply increasing the value of flexible generation sources that can quickly ramp generation up and down. The flexible generation hydropower can provide as well as the ancillary services (e.g., frequency and voltage regulation and reserves, black start capability) it provides for balancing and stabilizing the power grid are predicted to be of increased value in these future grid scenarios. Yet, the flexibility of hydropower may come with environmental costs due to up- and down-ramping of hydropower plants (i.e., quickly increasing or decreasing generation flows, respectively) which may strand fish, dewater or scour fish nests, alter habitat, or create unsafe recreational conditions that may be unacceptable to participants in the hydropower regulatory process. These types of environmental impacts are often mitigated through environmental flow requirements that specify minimum or maximum flow releases, or ramp-rates changes allowed at a hydropower facility. While it is not currently known to what degree electrical grid reliability could be affected by environmental flow requirements, gaining a better understanding of these interactions before the grid becomes more deeply decarbonized can help define what policy, regulation, or infrastructure may be needed to support the clean energy transition. As the future grid will rely on hydropower to provide both flexibility and robust environmental protections, the analyses and tools described in this report are centered on making mechanistic linkages between energy and the environment in hydropower systems. This understanding of energy-environment linkages can provide the foundational understanding needed to quantitatively assess the trade-offs between the increased generation flexibility that hydropower will be expected to provide and the environmental impacts of this flexibility. This report seeks to provide an objective foundation for building future science and tools that can be used by a broad spectrum of the hydropower community that is involved in licensing or environmental regulatory proceedings tasked with balancing energy and environmental objectives through flow management.

13 HYDRO ENERGY↗

Operation at Reduced Atmospheric Pressure and Concept of Reliability Redundancy for Optimized Design of Insulation Systems

Electrified transportation is calling for insulation design criteria that is adequate to provide elevated levels of power density, power dynamics and reliability. Increasing voltage levels are expected to cause accelerated intrinsic and extrinsic aging effects which will not be easily predictable at the design stage due to a lack of suitable modeling. Designing reliable insulation systems would require finding solutions able to control accelerated aging due to an unpredictable increase of intrinsic stresses and the onset of extrinsic stresses as partial discharges. This paper proposes the concept of reliability redundancy for the insulation design of aerospace electrical asset components, which is also validated at lower-than-standard atmospheric pressure. The principle is that extrinsic-aging-free design might be achieved upon determining the aging stress or abnormal service stresses distribution and being sure that aging will not generate conditions that can incept extrinsic aging (partial discharges) during operation life. However, such information is never, in practice, fully available to insulation system designers. Hence, especially in critical applications such as electrified aircraft, aerospace, and combat ships a further level of reliability should be added to a partial-discharge-free design, which can consist of the use of corona-resistant materials and/or of life models able to consider the accelerated aging effect of partial discharges (or any other type of extrinsic-accelerated aging factor). Innovative life modeling considering both extrinsic and intrinsic aging stresses, insulating material testing to estimate model parameters, and a metric for quantifying the extent of corona (or partial discharge) resistance can lead to establishing feasibility and limit conditions for optimized or fully reliability-redundant design. It is shown in the paper that if an extrinsic-aging-free design is not feasible, and it is therefore replaced by a redundant design, a further level of reliability redundancy can be provided by effective condition monitoring plans.

Montanari, Gian Carlo↗

Multiple soliton production and the Korteweg-de Vries equation.

Compressive square-wave pulses are launched in a double-plasma device. Their evolution is interpreted according to the Korteweg-de Vries description of Washimi and Taniuti. Square-wave pulses are an excitation for which an explicit solution of the Schrodinger equation permits an analytical prediction of the number and amplitude of emergent solitons. Bursts of energetic particles (pseudowaves) appear above excitation voltages greater than an electron thermal energy, and may be mistaken for solitons.

Hershkowitz, N.↗

Recent experimental measurements of space platform charging at LEO altitudes

The paper discusses some of the results of vehicle electrical potential from recent sounding rocket experiments involving charging of a space platform by both electron beam emission and by the application of differential bias between elements of the platform. Conclusions are presented that are applicable to the experimental parameters of the CHARGE-2 and SPEAR-1 payloads. The currents collected by HV biased collectors in the sphere show strong magnetic limiting and are close to the values predicted by Parker and Murphy (1967). No volume breakdown was observed above 100 km altitude by exposing voltages up to 45 kV to the ionosphere in the SPEAR-1 payload. The release of gas at flow rates typical of ACS systems can provide sufficient plasma to electronically neutralize space platforms biased at either positive or negative potentials.

Raitt, W. J.↗

Photovoltaic Plasma Interaction Test 2

The International Space Station (ISS) program is developing a plasma contactor to mitigate the harmful effects of charge collection on the station's large photovoltaic arrays. The purpose of the present test was to examine the effects of charge collection on the solar array electrical circuit and to verify the effectiveness of the plasma contactor. The results showed that the plasma contactor was able to eliminate structure arcing for any array output voltage. However, the current requirements of the plasma contactor were higher than those for prior testing and predicted by analysis. Three possible causes for this excess current demand are discussed. The most likely appeared to be a high local pressure on or very near the surface of the array as a result of vacuum tank conditions. Therefore, in actual space conditions, the plasma contactor should work as predicted.

Kaufman, Bradford A.↗

Low Intensity Low Temperature (LILT) Measurements and Coefficients on New Photovoltaic Structures

Past NASA missions to Mars, Jupiter and the outer planets were powered by radioisotope thermal generators (RTGs). Although these devices proved to be reliable, their high cost and highly toxic radioactive heat source has made them far less desirable for future planetary missions. This has resulted in a renewed search for alternate energy sources, some of them being photovoltaics (PV) and thermophotovoltaics (TPV). Both of these alternate energy sources convert light/thermal energy directly into electricity. In order to create a viable PV data base for planetary mission planners and cell designers, we have compiled low intensity low temperature (LILT) I-V data on single junction and multi-junction high efficiency solar cells. The cells tested here represent the latest photovoltaic technology. Using this LILT data to calculate Short Circuit Current (I(sub sc)), Open Circuit Voltage (V(sub os)), and Fill Factor (FF) as a function of temperature and intensity, an accurate prediction of cell performance under the AM0 spectrum can be determined. When combined with QUantum efficiency at Low Temperature (QULT) data, one can further enhance the data by adding spectral variations to the measurements. This paper presents an overview of LILT measurements and is only intended to be used as a guideline for material selection and performance predictions. As single junction and multi-junction cell technologies emerge, new test data must be collected. Cell materials included are Si, GaAs/Ge, GaInP/GaAs/GaAs, InP, InGaAs/InP, InP/InGaAs/InP, and GaInP. Temperatures range down to as low as -180 C and intensities range from 1 sun down to 0.02 suns. The coefficients presented in this paper represent experimental results and are intended to provide the user with approximate numbers.

Scheiman, David A.↗

Electrical Properties and Power Considerations of a Piezoelectric Actuator

This paper assesses the electrical characteristics of piezoelectric wafers for use in aeronautical applications such as active noise control in aircraft. Determination of capacitive behavior and power consumption is necessary to optimize the system configuration and to design efficient driving electronics. Empirical relations are developed from experimental data to predict the capacitance and loss tangent of a PZT5A ceramic as nonlinear functions of both applied peak voltage and driving frequency. Power consumed by the PZT is the rate of energy required to excite the piezoelectric system along with power dissipated due to dielectric loss and mechanical and structural damping. Overall power consumption is thus quantified as a function of peak applied voltage and driving frequency. It was demonstrated that by incorporating the variation of capacitance and power loss with voltage and frequency, satisfactory estimates of power requirements can be obtained. These relations allow general guidelines in selection and application of piezoelectric actuators and driving electronics for active control applications.

Jordan, T.↗

DISTRIBUTION TRANSFORMER ASSET MONITORING ON THE GRID EDGE USING SMART SENSOR DATA

As new loads such as rooftop photovoltaics, electric vehicles and other distributed energy resources become commonplace on the distribution grid, the stress on already aging assets begins to escalate. This increased loading and changing dynamics can exacerbate failure rates. While traditional monitoring efforts focus on transmission and generation assets, utilities are now beginning to pay close attention to distribution assets in order to increase reliability indices and reduce cost from unexpected outages. This research develops low-cost and scalable methods to monitoring the health of a critical distribution grid asset: the service transformer. Existing methods in literature are either invasive and thus difficult to implement or require the device to be tested offline in an expensive lab setting. Data from the ubiquitous smart meter as well as a novel Bluetooth based transformer monitor are leveraged to automatically notify the utility of deteriorating or damaged transformers. Voltage, temperature, and vibration are some of the signals measured and analyzed by the proposed algorithms to predict transformer failures. Furthermore, these algorithms are designed to keep the implementation and processing costs low by taking advantage of edge computing where possible.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Modeling of Power Conversion Stages for an Exascale Supercomputer

In this paper a power conversion and energy consumption model for an exascale supercomputer is investigated. Power consumption, energy loss and efficiency are derived for the 27.2 MW liquid-cooled, centralized, High Performance Computing (HPC) power system, which is supplied directly from the 480 V three-phase mains. Two energy conversion stages are analyzed, measured and modeled. The model is developed in order to be adapted and implemented in a digital twin platform utilizing a Resource Allocator and Power Simulator (RAPS) module. RAPS enables estimation of potential energy savings in the direct AC power supply architecture via both conventional rectifier load sharing (commonly used in HPC systems), as well as smart rectifier load sharing. Moreover, besides the direct AC supply architecture analysis, the full direct DC supply architecture with with 1 kV DC bus were also studied. Comparison of 10 hour time frame operation of the system, with direct 480 V AC voltage supply with conventional and smart load sharing and medium dc voltage supply were done. For the direct AC supply architecture, with conventional and smart load sharing the predicted power loss was approximately 840 kW and 820 kW, respectively and the predicted total system efficiency was 92.87% and 93.05%, respectively. For the direct DC supply architecture with the 1000 V DC supply bus power loss was approximately 340 kW and the predicted total system efficiency was 97.02%.

Wojda, Rafal↗

BatteryPro: A Python Toolkit for Battery Data Analysis and Machine Learning Predictions

Analyzing battery test data for research & development can be time-consuming since battery tests often run on the order of months to years, generating large volumes of data. BatteryPro is a comprehensive Python package and software designed to facilitate advanced analysis and performance predictions for battery test data. Developed for battery researchers, it supports data types from widely used battery testing instruments, including MACCOR and Biologic cycling systems. The software provides a variety of tools for extracting and plotting key battery parameters such as time, voltage, capacity, current, and pressure. In addition to its extensive data analysis capabilities, BatteryPro features a dedicated machine learning module that employs a Bayesian Gaussian Mixture Model (GMM) to predict battery performance and degradation. Users can generate synthetic capacity fade data, calculate fade metrics, and leverage predictive models to forecast long-term battery behavior. The software's graphical user interface (GUI) enhances usability, allowing researchers to upload, merge, and analyze multiple data files with full customizability. The GUI also supports machine learning predictions, enabling users to fit models and make predictions based on selected data and parameters. BatteryPro is built using QtDesigner, scikit-learn, matplotlib, and pandas, ensuring a high level of customization, flexibility, and accuracy in battery data analysis. This tool aims to empower researchers with the ability to perform detailed battery analysis and make informed predictions, ultimately advancing the field of battery research.

25 - ENERGY STORAGE↗

A Generic Two-Vector Model Predictive Control for Hybrid Multilevel Converters

In this article, a generic two-vector model predictive control (TV-MPC) strategy is proposed for the hybrid multilevel converters (HMCs). The proposed method selects two optimal voltage vectors among all the vector candidates using a geometric positioning approach to reduce the computational burden, which is a common issue in the existing MPC methods for HMC. Then duty cycles of the two selected vectors are optimized to minimize the current tracking error, such that the current tracking performance can be enhanced compared with the conventional MPC. In addition, the voltages of the floating dc capacitors can be balanced by evaluating all switching sequences that belong to the optimal voltage vectors with optimal duty cycles. Here, the concept of the proposed TV-MPC is generic and applicable for any HMCs. A typical HMC based on active neutral-point-clamped topology is adopted as a case study in this work. Comprehensive simulation and experimental studies are performed on an all silicon-carbide HMC prototype to validate the effectiveness of the proposed control scheme.

42 ENGINEERING↗

Simple Cell Balance Circuit

A method has been developed for continuous cell voltage balancing for rechargeable batteries (e.g. lithium ion batteries). A resistor divider chain is provided that generates a set of voltages representing the ideal cell voltage (the voltage of each cell should be as if the cells were perfectly balanced). An operational amplifier circuit with an added current buffer stage generates the ideal voltage with a very high degree of accuracy, using the concept of negative feedback. The ideal voltages are each connected to the corresponding cell through a current- limiting resistance. Over time, having the cell connected to the ideal voltage provides a balancing current that moves the cell voltage very close to that ideal level. In effect, it adjusts the current of each cell during charging, discharging, and standby periods to force the cell voltages to be equal to the ideal voltages generated by the resistor divider. The device also includes solid-state switches that disconnect the circuit from the battery so that it will not discharge the battery during storage. This solution requires relatively few parts and is, therefore, of lower cost and of increased reliability due to the fewer failure modes. Additionally, this design uses very little power. A preliminary model predicts a power usage of 0.18 W for an 8-cell battery. This approach is applicable to a wide range of battery capacities and voltages.

Johnson, Steven D.↗