Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage mitigation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Nitrogen-doped graphene-wrapped Cu 2 S as a superior anode in sodium-ion batteries

Sodium-ion batteries (SIBs) have been attracting an ever-growing research interest, mainly ascribed to their cost-effectiveness. However, SIBs have been significantly hindered by lack of a suitable anode. Herein, an exceptional Cu 2 S-based composite anode is developed via a facile ball-milling method, in which Cu 2 S particles are wrapped by nitrogen-doped graphene sheets (Cu 2 S@NG). This Cu 2 S@NG composite anode enables extremely long cycling life, ultra-stable cyclability with high capacity, and excellent rate capability. The superior performance of the Cu 2 S@NG composite is owing to its intriguing core-shell structure and the exceptional properties of both the Cu 2 S and NG. In this study, it is found that the NG shell yields multiple merits in improving the performance of Cu 2 S: (i) mitigating the loss of active materials, (ii) constituting a stable interface, (iii) providing improved electrical conductivity and good ionic transfer, and (iv) enhancing mechanical integrity. Additionally, the vital effects of different voltage windows and a surface coating via atomic layer deposition on further enhancing performance are clarified. Significantly, the electrochemical mechanism of Cu 2 S during sodiation/desodiation is unveiled using advanced synchrotron-based in-situ X-ray diffraction and X-ray adsorption spectroscopy. This work represents a great advance in seeking high-performance anodes in SIBs.

25 ENERGY STORAGE↗

Renewable Energy, Photovoltaic Systems Near Airfields. Electromagnetic Interference

Recent increases in photovoltaic (PV) systems on Department of the Navy (DON) land and potential siting near airfields prompted Commander, Naval Installations Command to fund the Naval Facilities Engineering Command to evaluate the impact of electromagnetic interference (EMI) from PV systems on airfield electronic equipment. Naval Facilities Engineering and Expeditionary Warfare Center tasked Department of Energy National Renewable Energy laboratory (NREL) to conduct the assessment. PV systems often include high-speed switching semiconductor circuits to convert the voltage produced by the PV arrays to the voltage needed by the end user. Switching circuits inherently produce electromagnetic radiation at harmonics of the switching frequency. In this report, existing literature is summarized and tests to measure emissions and mitigation methods are discussed. The literature shows that the emissions from typical PV systems are low strength and unlikely to cause interference to most airfield electronic systems. With diligent procurement and siting of PV systems, including specifications for FCC Part 15 Class A compliant equipment and a 250-foot setback from communication equipment, NREL anticipates little to no EMI impact on nearby communications or telemetry equipment.

14 SOLAR ENERGY↗

Total Dose Effects on Single Event Transients in Digital CMOS and Linear Bipolar Circuits

This presentation discusses the effects of ionizing radiation on single event transients (SETs) in circuits. The exposure of integrated circuits to ionizing radiation changes electrical parameters. The total ionizing dose effect is observed in both complementary metal-oxide-semiconductor (CMOS) and bipolar circuits. In bipolar circuits, transistors exhibit grain degradation, while in CMOS circuits, transistors exhibit threshold voltage shifts. Changes in electrical parameters can cause changes in single event upset(SEU)/SET rates. Depending on the effect, the rates may increase or decrease. Therefore, measures taken for SEU/SET mitigation might work at the beginning of a mission but not at the end following TID exposure. The effect of TID on SET rates should be considered if SETs cannot be tolerated.

Buchner, S.↗

Event-Driven Predictive Approach for Real-Time Volt/VAR control with CVR in solar PV rich Active Distribution Network

The focus of this paper is on analyzing the impact of conservation voltage reduction in the presence of active devices such as solar photovoltaic (PV) and developing controls that leverage these distributed energy resources. An event-driven predictive approach for real-time volt/volt-ampere reactive (VAR) optimization, along with local two-level adaptive volt/VAR droop-based control algorithm for advanced distribution management systems, is introduced. The methodology covers aggregated and autonomous controls under different timescale operations, including the impact and effect of unpredicted events such as cloud transients on PV power production. In addition, the control schemes include the uncertainties in PV power generation and load power demand. The proposed methodology is validated in a real-time framework using the real-time digital simulator platform through co-simulation with models based on Python and OpenDSS (Open Distribution System Simulator). The developed methodology is tested on the modified IEEE 123-feeder test system. The results reveal that the proposed methodology works well in the presence of high penetrations of PV power, produces significant energy savings, and mitigates over-/undervoltage problems.

14 SOLAR ENERGY↗

A Real-Time Testbed for Smart Inverter Cyber Security Studies

Distributed energy resources (DER) have become a popular solution to modern-day issues surrounding the efficiency and reliability of power generation, as well as climate change concerns. Energy centers are shifting towards incorporating smart inverters with embedded functionalities such as high voltage ride through (HVRT), low voltage ride through (LVRT), active and reactive power compensation. However, the integration of smart inverters leave DER systems highly vulnerable to cybersecurity threats. The distributed network protocol 3 (DNP3) is a common method of communication between grid-tied hardware. Despite its popularity, the level of security leaves all hardware connected to the grid at risk of severe cyber-attacks. Thus, it is important to study any potential cybersecurity threats towards grid-tied smart inverters to mitigate cybersecurity vulnerabilities and refine existing cyber-security protections. This report describes the proposed testbed design to study cybersecurity threats to smart inverters. The testbed utilizes a real-time simulation case in RSCAD that includes a grid-tied wind turbine (WT) topology featuring two back-to-back two-level voltage source converters (BTB,2L-VSCs) and a permanent magnet synchronous machine (PMSM). The simulated case runs within the NovaCor real time digital simulator (RTDS). This report focuses on the design and implementation of a single module of the GTNETx2 card as a distributed network protocol and the configuration of an IEEE 1518 DNP database file that includes input and output variables mapped to different connection points in the grid that transmit and receive discrete, analog, and binary signals on command. This allows realistic emulation of the communication between the smart inverter and the grid for cybersecurity studies.

97 MATHEMATICS AND COMPUTING↗

In-situ hydrogen microstructural characterization of Si heterojunction passivation: Addressing V OC degradation and mitigation pathways

Si heterojunction (SHJ) solar cells have demonstrated record efficiency >27%, approaching the theoretical limit of ≈ 29%, primarily due to best surface/interface defect passivation provided by deposited thin layers of hydrogenated amorphous silicon (a-Si:H). Such excellent surface/interface passivation reduces recombination loss and result in >100 mV improvement of cell open circuit voltage (V OC ) to ≈ 750 mV, thus the cell efficiency. However, fielded SHJ modules exhibit loss of V OC and hence efficiency over time in years, presumably due to degradation related to a-Si:H layers. This adversely affects the technology’s market acceptance, and levelized cost of energy (LCOE). It is hypothesized that the origin of a-Si:H degradation is somehow related to the presence of weak Si–Si bonds and hydrogen in a-Si:H films. The objective of this project is to test this hypothesis by directly measuring chemical and structural changes occurring within SHJ component layers and solar cells. This is achieved by developing an innovative in-situ Fourier transform infrared (FTIR) spectrometry apparatus to monitor hydrogen microstructural changes occurring within amorphous silicon and decipher hydrogen evolution kinetics over time when samples are exposed to heat and/or light stress. These in-situ measured hydrogen microstructural changes are correlated to the changes in effective minority carrier lifetime (τ eff ), implied V OC (iV OC ), surface recombination velocity (S), and cell V OC . These mechanistic understandings will provide critical guidance to mitigate the V OC -driven degradation of SHJ solar cell performance. Passivation optimization and degradation analysis of individual SHJ component structures were achieved through systematic deposition of three symmetric structures and the completed SHJ solar cell structure. The three symmetric structures used were intrinsic a-Si:H [(i)a-Si:H] layers in a bilayer structure, intrinsic and p-type doped stacked layers [(i-p)a-Si:H] representing the front heterojunction in the SHJ cell, and intrinsic and n-typed doped stacked layers [(i-n)a-Si:H] representing the back-side back surface field (BSF) in the SHJ cell. State-of-the-art passivation qualities are demonstrated by a champion iV OC of 740 mV for the (i)a-Si:H layers, and the (i-n)a-Si:H symmetric structure. A 725 mV iV OC is observed for the (i-p)a-Si:H symmetric structure. These symmetric passivated SHJ component structures were subsequently subjected to different accelerated lifetime (ALT) stressors to identify which conditions contribute the most to iV OC degradation. Degradation of the thin (10 nm) (i)a-Si:H passivation layers without any additional overlying layers is minimal; complexity of this study arises due to unavoidable surface oxidation of (i)a-Si:H layer during most of the stress application, which is likely irrelevant for a full SHJ cell configuration with overlying protective layers. The iV OC degradation of symmetric structures is found to occur primarily at the (i-p)a-Si:H passivation stack under dark heat stress with associated hydrogen loss from the (p)a-Si:H layer. An activation energy for increase in S (defect creation) of 0.65 eV can be correlated to the activation energy of ≈ 0.4 eV for hydrogen loss from the (i-p)a-Si:H stack. This also suggests the presence of weakly bonded hydrogen in the (p)a-Si:H films, which effuses out of the film stack at such low activation energy. When light and heat stress are applied together, similar hydrogen loss from (i-p)a-Si:H stack is observed, however, does not appreciably degrade iV OC or increase S. This is an important result and departure from direct correlation between hydrogen loss and defect creation. This perhaps indicates additional defect chemistries or annealing that might be occurring in the presence of light requiring further detailed defect measurements. The full SHJ cell structure used for this project is depicted in Fig.1(d). SHJ cells with an initial V OC ≈ 700 mV were fabricated and subjected to similar ALT stress conditions. Cell V OC is found to degrade the most under dark heat stress and is confirmed by observed hydrogen migration out of the (i-p)a-Si:H stack. However, hydrogen cannot escape from the cell stack, it accumulates near the (p)a-Si:H/ITO contact interface, where ITO acts as a barrier preventing hydrogen loss. Furthermore, light-heat combined stress does not degrade V OC appreciably, confirming the occurrence of a defect annealing process.

14 SOLAR ENERGY↗

Unveiling the Role of Al 2 O 3 in Preventing Surface Reconstruction During High-Voltage Cycling of Lithium-Ion Batteries

Recent achievements in high-energy batteries have been made by using Ni-rich NMC cathodes (LiNi x Mn y Co 1–x–y O 2 with x > 0.5) in conjunction with higher cell voltages. However, these gains have come at a cost of fast capacity fade and poor rate performace. In our previous study, we showed that Al 2 O 3 ALD coatings on LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811) and LiNi 0.8 Co 0.15 Al 0.05 O 2 (NCA) cathodes prevented surface phase transitions, reduced impedance, and extended cycle life in high voltage cells. In this work, neutron diffraction (ND), X-ray photoelectron spectroscopy (XPS), and electron energy loss spectroscopy (EELS) are used to fully investigate the mechanism by which ALD surface coatings mitigate NMC811 cathode degredation. Refinement of ND patterns indicated no changes in the bulk crystal structure of cycled cathodes with or without the Al 2 O 3 coating. Rather, the improved performance of ALD-coated cathodes is clearly due to surface stabilization. EELS established that all three transition metal oxidation states were reduced at the surface of the uncoated cathode after cycling, whereas the coated cathode showed no changes in surface oxidation states relative to the bulk. The surface coatings also prevented transition metal dissolution and crossover. XPS analysis of the anode harvested from cycled cells with uncoated cathodes showed significant amounts of Mn deposited within the SEI. In contrast, no Mn could be detected on the anodes cycled with coated cathodes. These results affirm that ALD coatings can effectively reduce the reactivity of the NMC surface and prevent detrimental side reactions that shorten battery cycle life.

25 ENERGY STORAGE↗

First observation of unlocking the locked mode by electrode biasing on J-TEXT tokamak

Major disruptions, often caused by locked m/n = 2/1 modes (m/n is the poloidal/toroidal mode number), are great threat to a tokamak fusion reactor and should be mitigated or avoided. The locked 2/1 modes have been unlocked by electrode biasing (EB) for the first time in J-TEXT tokamak experiments. Furthermore, the application of a sufficiently negative EB voltage in plasma edge region quickly changes the phase and amplitude of the locked 2/1 mode and drives the mode to rotate in about 10–30 ms. For a larger EB current or a smaller locked mode amplitude, the mode is more easily to be unlocked, revealing a new method for mode unlocking and avoiding plasma disruptions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Operating Klystrons at the Spallation Neutron Source – Two Decades of Perspective

Klystron amplifiers have been operated at the Spallation Neutron Source (SNS) in support of the user program since 2006. SNS tubes have amassed over 100,000 hours of high-voltage and filament-on time providing a significant source of operational statistics for high power, high-duty klystrons. Additionally, the SNS Radiofrequency (RF) Systems Group has developed operational methods to mitigate specific reliability challenges, such as cathode arcing and output power instability. Despite much progress, many of these challenges persist, prompting the SNS to update the procedures used for klystron processing as well as develop a higher throughput test stand.

Moss, John [ORNL] (ORCID:0009000085988916)↗

Nature-Inspired Motivation for Developing Self-Healable Electrical Insulation

Polymeric aircraft electrical insulation normally degrade by partial discharge with increasing voltage, which causes excessive localized Joule heating in the material and ultimately leads to dielectric failure of the insulator through thermal breakdown. Self-healing insulation may be a viable option to mitigate permanent mechanical degradation, thus increasing the longevity of the material. Instead of relying on catalyst and monomer-filled microcapsules to crack, flow, and cure at the damaged sites described in well-published mechanisms, self-healing through establishment of ionic crosslinks allows for multiple healing events to occur as well as achieving full recovery strength under certain thermal environments. Surlyn®, a commercial ionically-crosslinked material, was investigated as a self-healing insulation candidate based on prior demonstrations of self-healing behavior. Thin films of varying thicknesses were investigated and the effects of thickness on the dielectric strength were evaluated and compared to representative polymer insulators. The effects of thermal conditioning on the recovery strength and healing were observed as a function of time following dielectric breakdown. Moisture absorption was studied to determine if moisture absorption rates in Surlyn® were lower than that of common polyimide insulators. Preliminary data showed that when cut, Surlyn® films lost nearly 60 percent of its original dielectric strength. However, when Surlyn® was cut and subsequently annealed, the films not only re-mended, but also recouped approximately 93 percent of its original dielectric strength, along with 90-97 percent of its mechanical strength.

electrical↗

Power-Domain Impedance Theory for the Analysis and Mitigation of Interarea Oscillations: Preprint

This paper presents an impedance-based theory for the analysis and mitigation of interarea oscillations in power systems. Because low-frequency power system oscillations primarily manifest in phasor quantities, including active and reactive power flows, and the magnitude and frequency of bus voltages, a new-type of impedance, called power-domain impedance, is defined in terms of these phasor quantities. The power-domain impedance provides an intuitive framework for the analysis of interarea oscillations without requiring internal details of generators, and it is ideally suited for developing oscillation damping controls in inverter-based resources. The power-domain impedance theory is demonstrated in this paper using PSCAD simulations of a two-area system. The theory is also used for designing damping control in synchronous generators and a wind power plant in the two-area system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power system effects and mitigation recommendations for DER cyberattacks

Extensive deployment of interoperable distributed energy resources (DER) is increasing the power system cyber security attack surface. National and jurisdictional interconnection standards require DER to include a range of autonomous and commanded grid‐support functions, which can drastically influence power quality, voltage, and bulk system frequency. Here, the authors investigate the impact to the cyber‐physical power system in scenarios where communications and operations of DER are controlled by an adversary. The findings show that each grid‐support function exposes the power system to distinct types and magnitudes of risk. The physical impact from cyber actions was analysed in cases of DER providing distribution system voltage regulation and transmission system support. Finally, recommendations are presented for minimising the risk using engineered parameter limits and segmenting the control network to minimise common‐mode vulnerabilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Constructing uniform oxygen defect engineering on primary particle level for high-stability lithium-rich cathode materials

Lithium-rich layered cathode materials are considered to be research focus of cathode candidates for next generation lithium-ion batteries due to their high specific capacity and low cost. However, lattice deoxidation associated with elemental migration and internal local shrinkage usually results in deteriorated cyclic performance and notorious voltage attenuation, severely limiting its application. In this paper, we have successfully injected uniform oxygen defects into surface region of Li 1.2 Ni 0.13 Co 0.13 Mn 0.54 O 2 primary particles under the high-pressure and weak carbonate environment. Various experimental investigations indicate that the injected robust oxygen defects can not only mitigate detrimental interfacial reactions but also suppress unfavorable lattice variation and particle breakage. More importantly, theoretical calculations unravel the critical roles of oxygen defects in regulating energy band structure for strengthened anionic reversibility. Owing to stabilization effects of unique oxygen defect engineering, the modified Li 1.2 Ni 0.13 Co 0.13 Mn 0.54 O 2 cathode has harvested dramatically enhanced electrochemical performance including a high initial coulombic efficiency of 96.6%, an outstanding capacity retention of 91.96% (1C, 200 cycles) and suppressed voltage decay of only 1.62 mV per cycle. Therefore, this facile and effective defect engineering strategy could establish new guidance for promoting practical application of Li-rich Mn-based cathode material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Self-Healable Electrical Insulation for High Voltage Applications

Polymeric aircraft electrical insulation normally degrades by partial discharge with increasing voltage, which causes excessive localized Joule heating in the material and ultimately leads to dielectric failure of the insulator through thermal breakdown. Developing self-healing insulation could be a viable option to mitigate permanent mechanical degradation, thus increasing the longevity of the insulation. Instead of relying on catalyst and monomer-filled microcapsules to crack, flow, and cure at the damaged sites described in well-published mechanisms, establishment of ionic crosslinks could allow for multiple healing events to occur with the added benefit of achieving full recovery strength under certain thermal environments. This could be possible if the operating temperature of the insulator is the same as or close to the temperature where ionic crosslinks are formed. Surlyn, a commercial material with ionic crosslinks, was investigated as a candidate self-healing insulator based off prior demonstrations of self-healing behavior. Thin films of varying thicknesses were investigated and the effects of thickness on the dielectric strength were evaluated and compared to representative polymer insulators. The effects of thermal conditioning on the recovery strength and healing were observed as a function of time following dielectric breakdown. Moisture absorption was also studied to determine if moisture absorption rates in Surlyn were lower than that of common polyimides.

electrical insulation↗

Field Demonstration of Using Advanced PV Inverter Functionality to Mitigate the Impacts of High-Penetration PV Grid Integration on the Distribution System

This paper describes a field demonstration that was completed to show the ability of currently installed PV inverters to implement advanced PV inverter functionality and that such functionality was effective at reducing the voltage-related PV impacts of high-penetration PV integration. A distribution circuit was instrumented and then tested for a two week period using off-unity power factor operation. Specifically, an inductive power factor of -0.95 was demonstrated. The results show that the PV inverters were capable of such operation and that the use of off-unity power factor operation was highly effective at reducing the voltage-related impacts of the PV systems interconnected to the circuits used in the demonstration. The impacts of using off-unity power factor operation - resulting in additional reactive current flow on the distribution circuit - are also presented and analyzed.

14 SOLAR ENERGY↗

Cybersecurity Enhancement for Multi-Infeed High-Voltage DC Systems

Composed of multiple two-terminal high-voltage DC (HVDC) transmission systems, a multi-infeed HVDC (MIDC) system exchanges massive power among multiple asynchronous AC systems. However, as an intrinsically cyber-physical system, an MIDC system could suffer from cyber-attacks, leading to massive power mismatches in multiple AC systems, and resulting in catastrophic consequences. Since the sequential responses of an MIDC system and interconnected AC systems are in different timescales, this paper first establishes a two-timescale model to evaluate the sequential impacts caused by cyber-attacks. Then, an event-triggered cyber-defense strategy is proposed to enhance the cybersecurity of an MIDC system by mitigating multiple non-simultaneous cyber-attacks. Whenever new cyber-attack events occur, the proposed cyber-defense strategy, which is mathematically modeled as a mixed-integer quadratic programming problem, is executed on-line and updated in an event-triggered manner. Here, simulation results on an MIDC system demonstrate that the low-cost and almost blind cyber-attacks can cause severe frequency deviations, and the proposed strategy can mitigate multi-cyber-attacks effectively.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhanced Electrochemical Performance of Disordered Rocksalt Cathodes in a Localized High‐Concentration Electrolyte

Abstract Lithium (Li)‐rich transition metal oxide cathodes with a cation disordered rock salt structure (DRX) are increasingly gaining popularity for advanced Li batteries as they offer high capacity and cost benefits over the commonly used layered Li transition metal oxide cathodes. However, the performance of DRX cathodes and their applications are limited by severe side reactions between the cathode and the state‐of‐the‐art carbonate‐based electrolytes at high voltage of 4.8 V, transition metal dissolution, and structural instability of the cathode particles. In this work, an advanced localized high‐concentration electrolyte (LHCE) is developed to form a stable cathode‐electrolyte interphase and mitigate structural instability of the Li 1.13 Mn 0.66 Ti 0.21 O 2 (LMTO) DRX during electrochemical cycling. Li||LMTO half cells with the LHCE demonstrate increased capacity, cycling stability, and superior rate capability compared with cells containing a conventional carbonate electrolyte. For instance, the Li||LMTO cells cycled in LHCE show a higher initial capacity of 205.2 mAh g −1 and a better capacity retention of 72.5% after 200 cycles at a current density of 20 mA g −1 than those with the conventional electrolyte (initial capacity of 187.7 mAh g −1 and capacity retention of 19.9%). This work paves the way to the development of practical DRX cathode‐based high‐energy Li batteries.

25 ENERGY STORAGE↗

ByzSec — A Multi-layered Byzantine Resilient Architecture for Bulk Power System Protective Relays

Reliability, selectivity, and sensitivity are the fundamental attributes of any protection system, acting as the main drivers in the selection of schemes, and equipment. In high-voltage systems, microprocessor-based relays represent the industry’s preferred solution, providing engineers with a vast array of benefits. However, they remain vulnerable to cybersecurity events that may compromise their functionality. To help mitigate against potential cybersecurity risks, this paper presents a fault-tolerant, Byzantine Resilient (BR) architecture that significantly increases the cybersecurity attributes of a protection system while minimizing the amount of performance impacts and integration overheads introduced. The solution relies on an array of independent relays that utilize robust consensus methods (based on Spire [1], [2]) to ensure correct system behavior is achieved even when a relay has been compromised. Furthermore, the solution has been complemented with a custom-built Situational Awareness engine that can be used to detect and identify potential threats. The implemented solution has been developed in consultation with three hardware vendors and has been tested to comply with the performance requirements of a 345kV differential protection scheme (87T). The results indicate that the proposed architecture is a comprehensive solution that: supports the strict correctness and performance requirements of the bulk power grid while providing a cost-effective alternative that offers a seamless, long-term solution.

byzantine security, Fault Tolerant Application Sof↗