Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vapor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

The seasonal variation of water vapor and ozone in the upper mesosphere - Implications for vertical transport and ozone photochemistry

This paper reviews the data base supplied by ground-based microwave measurements of water vapor in the mesosphere obtained in three separate experiments over an eight-year period. These measurements indicate that the seasonal variation of water vapor in the mesosphere is dominated by an annual component with low values in winter and high values in summer, suggesting that the seasonal variation of water vapor in the mesosphere (below 80 km) is controlled by advective rather than diffusive processes. Both the seasonal variation and the absolute magnitude of the water vapor mixing ratios obtained in microwave measurements were corroborated by measurements obtained in the Spacelab GRILLE and ATMOS experiments, and were found to be consistent with several recent mesospheric dynamics studies.

Bevilacqua, Richard M.↗

An algorithm for retrieving water vapor profiles in clear and cloudy atmospheres from 183 GHz radiometric measurements - Simulation studies

The latent heat represented by atmospheric water vapor is extremely important to the energetics of the earth system. Future satellites (NOAA and DMSP) will carry microwave radiometers designed to measure the profile of water vapor globally. The problem of retrieving water vapor from the measurements is highly nonlinear even in clear atmospheres and the addition of clouds only makes it more so. In this paper, an algorithm with several novel features, which will retrieve water vapor profiles from microwave radiometric measurements even in the presence of clouds, is developed. Simulations with this algorithm show a vertical resolution on the order of 3 km and that clouds are well handled in many, but not all, circumstances. The most surprising result is that clouds can actually improve the vertical resolution of the retrieval.

Wilheit, Thomas T.↗

Low temperature measurement of the vapor pressures of planetary molecules

Interpretation of planetary observations and proper modeling of planetary atmospheres are critically upon accurate laboratory data for the chemical and physical properties of the constitutes of the atmospheres. It is important that these data are taken over the appropriate range of parameters such as temperature, pressure, and composition. Availability of accurate, laboratory data for vapor pressures and equilibrium constants of condensed species at low temperatures is essential for photochemical and cloud models of the atmospheres of the outer planets. In the absence of such data, modelers have no choice but to assume values based on an educated guess. In those cases where higher temperature data are available, a standard procedure is to extrapolate these points to the lower temperatures using the Clausius-Clapeyron equation. Last summer the vapor pressures of acetylene (C2H2) hydrogen cyanide (HCN), and cyanoacetylene (HC3N) was measured using two different methods. At the higher temperatures 1 torr and 10 torr capacitance manometers were used. To measure very low pressures, a technique was used which is based on the infrared absorption of thin film (TFIR). This summer the vapor pressure of acetylene was measured the TFIR method. The vapor pressure of hydrogen sulfide (H2S) was measured using capacitance manometers. Results for H2O agree with literature data over the common range of temperature. At the lower temperatures the data lie slightly below the values predicted by extrapolation of the Clausius-Clapeyron equation. Thin film infrared (TFIR) data for acetylene lie significantly below the values predicted by extrapolation. It is hoped to bridge the gap between the low end of the CM data and the upper end of the TFIR data in the future using a new spinning rotor gauge.

Kraus, George F.↗

Atmospheric water vapor transport: Estimation of continental precipitation recycling and parameterization of a simple climate model

The advective transport of atmospheric water vapor and its role in global hydrology and the water balance of continental regions are discussed and explored. The data set consists of ten years of global wind and humidity observations interpolated onto a regular grid by objective analysis. Atmospheric water vapor fluxes across the boundaries of selected continental regions are displayed graphically. The water vapor flux data are used to investigate the sources of continental precipitation. The total amount of water that precipitates on large continental regions is supplied by two mechanisms: (1) advection from surrounding areas external to the region; and (2) evaporation and transpiration from the land surface recycling of precipitation over the continental area. The degree to which regional precipitation is supplied by recycled moisture is a potentially significant climate feedback mechanism and land surface-atmosphere interaction, which may contribute to the persistence and intensification of droughts. A simplified model of the atmospheric moisture over continents and simultaneous estimates of regional precipitation are employed to estimate, for several large continental regions, the fraction of precipitation that is locally derived. In a separate, but related, study estimates of ocean to land water vapor transport are used to parameterize an existing simple climate model, containing both land and ocean surfaces, that is intended to mimic the dynamics of continental climates.

Brubaker, Kaye L.↗

Liquid-propellant droplet vaporization and combustion in high pressure environments

In order to correct the deficiencies of existing models for high-pressure droplet vaporization and combustion, a fundamental investigation into this matter is essential. The objective of this research are: (1) to acquire basic understanding of physical and chemical mechanisms involved in the vaporization and combustion of isolated liquid-propellant droplets in both stagnant and forced-convective environments; (2) to establish droplet vaporization and combustion correlations for the study of liquid-propellant spray combustion and two-phase flowfields in rocket motors; and (3) to investigate the dynamic responses of multicomponent droplet vaporization and combustion to ambient flow oscillations.

Yang, Vigor↗

Remote sensing of water vapor features

The three major objectives of the project are outlined: (1) to describe atmospheric water vapor features as functions of space and time; (2) to evaluate remotely sensed measurements of water vapor content; and (3) to study relations between fine-scale water vapor fields and convective activity. Data from several remote sensors were used. The studies used the GOES/VAS, HIS, and MAMS instruments have provided a progressively finer scale view of water vapor features.

Fuelberg, Henry E.↗

Retrieval of water vapor profiles from microwave radiometric measurements near 90 and 183 GHz

Upwelling radiometric measurements at 90 GHz and three side bands near 183 GHz are used to retrieve water vapor profiles over the ocean surface. An algorithm incorporating a new technique of handling moderate cloud cover is illustrated for the profiling of both relative humidity and water vapor burden. It is shown that the retrieved relative humidity profiles reflect gross features of the corresponding profiles recorded by the radiosondes. However, the retrieval generally cannot produce fine details of the observed profiles at altitudes where a rapid change in relative humidity occurs. For this reason, comparison of retrieved and observed values at a given altitude often yields an appreciable rms error. Profiling of water vapor burden, a parameter equivalent to total integrated water vapor above a certain altitude, results in much better agreement, as expected. The rms error obtained from the results of the retrieval at the surface is comparable to that derived from the combination of measurements at 18 GHz and 21 GHz channels of the Scanning Multichannel Microwave Radiometer aboard the Nimbus 7 satellite.

Wang, J. R.↗

Cloud area determination from AVIRIS data using water vapor channels near 1 micron

Fractional cloud area is derived from spectral images collected by the Airborne Visible-IR Imaging Spectrometer (AVIRIS). The derivation is made by ratioing radiances near the 0.94- and the 1.14-microns water vapor band centers against those in the intermediate atmospheric window regions. The derivation makes use of the facts that (1) the reflectances of most ground targets vary approximately linearly with wavelength in the 0.94- and the 1.14-micron water vapor band absorption regions, and (2) the peak absorptions of the water vapor band over cloudy areas are smaller than those over nearby clear surface areas because of the rapidly decreasing atmospheric water vapor concentration with height. The band ratioing technique effectively discriminates among clouds and surface areas having similar reflectance values.

Gao, Bo-Gai↗

Simulation of cryogenic liquid flows with vapor bubbles

Liquid flows in rocket engine components (such as bearings, seals, and pumps) often involve the formation of vapor bubbles due to local superheating of the fluid (either boiling or cavitation). Under the present effort, an analysis has been developed for liquid flows with vapor bubbles, based on a combined Eulerian-Lagrangian technique, in which the continuous (liquid) phase is treated by solving a system of Eulerian conservation equations, while the discrete (vapor bubble) phase is dealt with by integrating Lagrangian equations of motion in computational coordinates. Vapor bubbles of changing size can be accommodated easily by this analysis, and models for the simulation of bubble formation, growth, and motion have been included. The effect of bubble motion and other bubble processes on the continuous (liquid) phase has been accounted for by appropriate bubble mass, momentum, and energy interchange source terms in the Eulerian conservation equations. To demonstrate the viability of the resulting procedure, the cavitating flow of liquid oxygen through a simplified model of a labyrinth seal has been successfully calculated.

De Jong, Frederik J.↗

Spaceborne observation of columnar water vapor - SSMI observations and algorithm

An analysis of the transfer of radiation with a frequency between 10 and 40 GHz through a cloud-free atmosphere is given, and the limitations of employing observations at 22.235 GHz for sensing the columnar water vapor (CWV) in the moist atmosphere (CWV above 40 kg/sq m) are shown. It is because of this limitation that a new method for the retrieval of columnar water vapor is described. This method uses both the horizontally and vertically polarized brightness temperatures measured at 19.35 GHz by the special sensor microwave imager (SSMI) which was launched as part of the Defense Military Satellite Program. The water vapor derived from the SSMI observations is validated against radiosonde observations that are near coincident in time and space with an rms error of 6 kg/sq m. This large rms is in part due to sensitivity of the retrieval method to the surface emission. Distributions of CWV over the oceans were obtained for a 3-month period starting September, 1987. These results are compared to other water vapor retrievals for the same period using the same microwave radiance data; they show close agreement except over the warmest water in the equatorial tropics.

Tjemkes, Stephen A.↗

Vapor plumes: A neglected aspect of impact cratering

When a meteorite or comet strikes the surface of the planet or satellite at typical interplanetary velocities of 10-40 km/sec, the projectile and a quantity of the target body vaporize and expand out of the growing crater at high speed. The crater continues to grow after the vapor plume has formed and the series of ejecta deposits is laid down ballistically while the crater collapses into its final morphology. Although the vapor plume leaves little evidence of its existence in the crater structure of surface deposits, it may play a major role in a number of impact-related processes. The vapor plume expanding away from the site of an impact carries 25-50 percent of the total impact energy. Although the plume's total mass is only a few times the mass of the projectile, its high specific energy content means that it is the fastest and most highly shocked material in the cratering event. The mean velocity of expansion can easily exceed the escape velocity of the target plane, so that the net effect of a sufficiently high-speed impact is to erode material from the planet.

Melosh, H. J.↗

Using silicon diodes for detecting the liquid-vapor interface in hydrogen

Tests were performed using commercially available silicon diode temperature sensors to detect the location of the liquid-vapor interface in hydrogen during ground test programs. Results show that by increasing the current into the sensor, silicon diodes can be used as liquid level point sensors. After cycling the sensors from liquid to vapor several times, it was found that with a 30 mA (milliamps) input current, the sensors respond within 2 seconds by measuring a large voltage difference when transitioning from liquid to vapor across the interface. Nearly instantaneous response resulted during a transition form vapor to liquid. Detailed here are test procedures, experimental results, and guidelines for applying this information to other test facilities.

Dempsey, Paula J.↗

Advanced Raman water vapor lidar

Water vapor and aerosols are important atmospheric constituents. Knowledge of the structure of water vapor is important in understanding convective development, atmospheric stability, the interaction of the atmosphere with the surface, and energy feedback mechanisms and how they relate to global warming calculations. The Raman Lidar group at the NASA Goddard Space Flight Center (GSFC) developed an advanced Raman Lidar for use in measuring water vapor and aerosols in the earth's atmosphere. Drawing on the experience gained through the development and use of our previous Nd:YAG based system, we have developed a completely new lidar system which uses a XeF excimer laser and a large scanning mirror. The additional power of the excimer and the considerably improved optical throughput of the system have resulted in approximately a factor of 25 improvement in system performance for nighttime measurements. Every component of the current system has new design concepts incorporated. The lidar system consists of two mobile trailers; the first (13m x 2.4m) houses the lidar instrument, the other (9.75m x 2.4m) is for system control, realtime data display, and analysis. The laser transmitter is a Lambda Physik LPX 240 iCC operating at 400 Hz with a XeF gas mixture (351 nm). The telescope is a .75m horizontally mounted Dall-Kirkham system which is bore sited with a .8m x 1.1m elliptical flat which has a full 180 degree scan capability - horizon to horizon within a plane perpendicular to the long axis of the trailer. The telescope and scan mirror assembly are mounted on a 3.65m x .9m optical table which deploys out the rear of the trailer through the use of a motor driven slide rail system. The Raman returns from water vapor (403 nm), nitrogen (383 nm) and oxygen (372 nm) are measured in addition to the direct Rayleigh/Mie backscatter (351). The signal from each of these is split at about a 5/95 ratio between two photomultiplier detectors. The 5 percent detector is used for measurements below about 4.0 km, while the 95 percent detector provides the information above this level.

Whiteman, David N.↗

Water vapor variance measurements using a Raman lidar

Because of the importance of atmospheric water vapor variance, we have analyzed data from the NASA/Goddard Raman lidar to obtain temporal scales of water vapor mixing ratio as a function of altitude over observation periods extending to 12 hours. The ground-based lidar measures water vapor mixing ration from near the earth's surface to an altitude of 9-10 km. Moisture profiles are acquired once every minute with 75 m vertical resolution. Data at each 75 meter altitude level can be displayed as a function of time from the beginning to the end of an observation period. These time sequences have been spectrally analyzed using a fast Fourier transform technique. An example of such a temporal spectrum obtained between 00:22 and 10:29 UT on December 6, 1991 is shown in the figure. The curve shown on the figure represents the spectral average of data from 11 height levels centered on an altitude of 1 km (1 plus or minus .375 km). The spectra shows a decrease in energy density with frequency which generally follows a -5/3 power law over the spectral interval 3x10 (exp -5) to 4x10 (exp -3) Hz. The flattening of the spectrum for frequencies greater than 6x10 (exp -3) Hz is most likely a measure of instrumental noise. Spectra like that shown in the figure are calculated for other altitudes and show changes in spectral features with height. Spectral analysis versus height have been performed for several observation periods which demonstrate changes in water vapor mixing ratio spectral character from one observation period to the next. The combination of these temporal spectra with independent measurements of winds aloft provide an opportunity to infer spatial scales of moisture variance.

Evans, K.↗

The role of thermal vapor diffusion in the subsurface hydrologic evolution of Mars

The hydrologic response of groundwater to the thermal evolution of the early martian crust is considered. When a temperature gradient is present in a moist porous medium, it gives rise to a vapor-pressure gradient that drives the diffusion of water vapor from regions of high to low temperature. By this process, a geothermal gradient as small as 15 K/km could drive the vertical transport of 1 km of water to the freezing front at the base of the martian crysophere every 10 exp 6-10 exp 7 years, or the equivalent of about 100-1000 km of water over the course of martian geologic history. Models of the thermal history of Mars suggest that this thermally-driven vapor flux may have been as much as 3-5 times greater in the past. The magnitude of this transport suggests that the process of geothermally-induced vapor diffusion may have played a critical role in the initial emplacement of ground ice and the subsequent geomorphic and geochemical evolution of the martian crust.

Clifford, Stephen M.↗

A differential absorption technique to estimate atmospheric total water vapor amounts

Vertically integrated water-vapor amounts can be remotely determined by measuring the solar radiance reflected by the earth's surface with satellites or aircraft-based instruments. The technique is based on the method by Fowle (1912, 1913) and utilizes the 0.940-micron water-vapor band to retrieve total-water-vapor data that is independent of surface reflectance properties and other atmospheric constituents. A channel combination is proposed to provide more accurate results, the SE-590 spectrometer is used to verify the data, and the effects of atmospheric photon backscattering is examined. The spectrometer and radiosonde data confirm the accuracy of using a narrow and a wide channel centered on the same wavelength to determine water vapor amounts. The technique is suitable for cloudless conditions and can contribute to atmospheric corrections of land-surface parameters.

Frouin, Robert↗

Global analyses of water vapor, cloud and precipitation derived from a diagnostic assimilation of SSM/I geophysical retrievals

An analytical approach is described for diagnostically assimilating moisture data from Special Sensor Microwave Imager (SSM/I) into a global analysis of water vapor, cloud content, and precipitation. In this method, 3D fields of wind and temperature values taken from ECMWF gridded analysis are used to drive moisture conservation equations with parameterized microphysical treatment of vapor, liquid, and ice; the evolving field of water vapor is periodically updated or constrained by SSM/I retrievals of precipitable water. Initial results indicate that this diagnostic model can produce realistic large-scale fields of cloud and precipitation. The resulting water vapor analyses agree well with SSM/I and have an additional advantage of being synoptic.

Robertson, Franklin R.↗

Water vapor recovery from plant growth chambers

NASA is investigating the use of plant growth chambers (PGCs) for space missions and for bases on the moon and Mars. Key to successful development of PGCs is a system to recover and reuse the water vapor that is transpired from the leaves of the plants. A design is presented for a simple, reliable, membrane-based system that allows the recovery, purification, and reuse of the transpired water vapor through control of temperature and humidity levels in PGCs. The system is based on two membrane technologies: (1) dehumidification membrane modules to remove water vapor from the air, and (2) membrane contactors to return water vapor to the PGC (and, in doing so, to control the humidity and temperature within the PGC). The membrane-based system promises to provide an ideal, stable growth environment for a variety of plants, through a design that minimizes energy usage, volume, and mass, while maximizing simplicity and reliability.

Ray, R. J.↗