Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “utility rate analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Integrated Icing Analysis of the D8 "Double Bubble" and the Hybrid Wing Body

A computational icing analysis utilizing LEWICE3D was performed for two next generational aircraft, the D8 “Double Bubble” and the Hybrid Wing Body (HWB). These two geometries were exposed to a variety of simulated clouds spanning the Appendix C and O regimes. Integrated results indicate that the Appendix O clouds generate a significantly higher water catch rate than Appendix C clouds as large radius of curvature components are susceptible to the highly ballistic large droplets found in Appendix O. Classically unprotected components, such as the nose/fuselage, may require anti-icing protection in configurations such as the D8 and HWB that generate lift from these components, dramatically increasing the size, extent, and power requirements of ice protection systems. Integrated results also indicate inclusion of the splashing model can significantly affect predicted water catch rates.

Computational,Icing,Integrated↗

Uncertainty Quantification in High-Low Dynamic System Coupling using RAVEN and TRANSFORM

This work demonstrates new functionality and applications stemming from the development of high-fidelity to low-fidelity (high-low) coupling for system simulations and to further explore the capabilities of the Risk Analysis Virtual Environment (RAVEN) in the performance of uncertainty quantification in this kind of high-low coupled system models. The work builds from previous work on high-low coupling that utilized COBRA-TF (CTF), the high-fidelity subchannel analysis code, with a low fidelity model built in ORNL’s TRANSFORM, the system analysis code, utilizing the Functional Mock-Up Interface (FMI). Steady-state and transient analysis examples using the high/low coupled models generated from CTF and TRANSFORM/FMI are investigated. The workflows for both steady-state and transient coupled simulations are described. A steady-state parameter sweep and uncertainty analysis of the primary flow rates and reactor power are demonstrated. Likewise, a transient pump trip and power ramp sensitivity studies are also demonstrated. This work elucidates some of the potential benefits and future needs of using RAVEN for high/low system coupling analysis of energy systems. It also shows some of the difficulties that can be encountered in coupling system simulations.

Williams, Wesley↗

Assessment of NASA Dual Microstructure Heat Treatment Method Utilizing Ladis SuperCooler(trademark) Cooling Technology

The intent of this investigation was to demonstrate the NASA DMHT method with a tailored Ladish SuperCool(Trademark) cooling method on a Rolls-Royce AE2100, stage 3 disk shape. One disk each of two alloys, LSHR and ME3, were successfully converted as shown by macrostructure. DMHT heating time selection and cooling rate was aided by finite element modeling analysis. Residual stresses were also predicted and reported. Detailed microstructural analysis was performed by NASA and included in this report. Mechanical property characterization, also planned by NASA, is incomplete at this time and not part of this report.

Lemsky, Joe↗

CO 2 utilization potential of a novel calcium ferrite based looping process fueled with coal: Experimental evaluation of various coal feedstocks and thermodynamic integrated process analysis

Here, conversion of CO 2 to CO was performed at 800-850C via reduction of calcium ferrite (CaFe 2 O 4 ) with coal followed by oxidation of reduced CaFe 2 O 4 with CO 2 to produce CO and partially oxidized Ca ferrite. The process was evaluated with several types of coals which included lignite, sub-bituminous, bituminous, anthracite and pet-coke. Reduction of CaFe 2 O 4 with sub-bituminous coal and lignite coal was more favorable than that with higher rank coals. Stable reactivity performance was demonstrated for 35-cycle test conducted with lignite coal/CaFe 2 O 4 at 800°C and with high conversion of CO 2 to CO. The rate of conversion of CO 2 to CO with reduced CaFe 2 O 4 was found to be 1st order with respect to CO 2 and had a low activation energy of 7.4 kJ/mol. Thermodynamic integrated process assessments suggest that two and three reactor process concepts can be realized and net CO 2 utilization achievable. The two reactor configuration shows the highest potential for CO 2 utilization while generating a value-added CO rich syngas stream.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Constraining (n,γ) cross sections via surrogate measurements with hyperion

Indirect measurement techniques, such as the surrogate method, are necessary to constrain cross sections and reaction rates that are inaccessible for direct measurement. The surrogate method uses an alternate reaction channel to populate a nucleus of interest, and combines resulting experimental data with theory to constrain the desired (n,γ) cross section. Individual γ-decay probabilities are experimentally extracted using γ-ray spectroscopy. This project utilizes surrogate analysis of 64,70 Zn(p,d) and 64,70 Zn(p,t) reactions measured with the Hyperion array at Texas A&M University's Cyclotron Facility to probe the relevant neutron capture reactions 61,62,67,68 Zn(n,γ). As an example, preliminary γ-decay probabilities are presented for 69 Zn.

Neutron capture↗

Decoupling the capacity fade contributions in polymer electrolyte-based high-voltage solid-state batteries

Polymer electrolyte (PE)-based solid-state batteries (PE-SSBs) made with high-voltage cathodes are known to suffer from severe capacity fade, stemming primarily from the poor oxidative stability of most PEs under high-voltage cycling conditions. PEs also suffer from greater ion-transport limitations compared to liquid or solid electrolytes. However, often, these limitations are collectively stated to be responsible for the observed capacity fade, and it is challenging to decouple the contributions of different factors. Herein, a tunable cell fabrication platform was developed to systematically investigate and decouple the two primary capacity fade drivers (cell impedance growth and kinetic limitations), while keeping the other cell parameters constant. Three PE types with distinct transport characteristics were compared. By utilizing a voltage profile analysis method, the contribution of the cell's internal impedance growth was quantitatively decoupled from the kinetic limitations stemming from the high concentration gradient in the polymer catholyte and slow charge transfer reactions. We demonstrate that the high interfacial impedance did not necessarily correlate with the high capacity fade rate. Kinetic limitations that are not reflected by impedance measurements can play a dominant role in causing cumulative capacity decay.

Ock, Ji-young [Oak Ridge National Laboratory (ORNL↗

Evaluation of current tropospheric mapping functions by Deep Space Network very long baseline interferometry

To compare the validity of current algorithms that map zenith tropospheric delay to arbitrary elevation angles, 10 different tropospheric mapping functions are used to analyze the current data base of Deep Space Network Mark 3 intercontinental very long baseline interferometric (VLBI) data. This analysis serves as a stringent test because of the high proportion of low-elevation observations necessitated by the extremely long baselines. Postfit delay and delay-rate residuals are examined, as well as the scatter of baseline lengths about the time-linear model that characterizes tectonic motion. Among the functions that utilize surface meteorological data as input parameters, the Lanyi 1984 mapping shows the best performance both for residuals and baselines, through the 1985 Davis function is statistically nearly identical. The next best performance is shown by the recent function of Niell, which is based on an examination of global atmospheric characteristics as a function of season and uses no weather data at the time of the measurements. The Niell function shows a slight improvement in residuals relative to Lanyi, but also an increase in baseline scatter that is significant for the California-Spain baseline. Two variants of the Chao mapping function, as well as the Chao tables used with the interpolation algorithm employed in the Orbit Determination Program software, show substandard behavior for both VLBI residuals and baseline scatter. The length of the California-Australia baseline (10,600 km) in the VLBI solution can vary by as much as 5 to 10 cm for the 10 mapping functions.

Sovers, O. J.↗

High Pressure Water Stripping Using Multi-Orifice Nozzles

The use of multi-orifice rotary nozzles not only increases the speed and stripping effectiveness of high pressure water blasting systems, but also greatly increases the complexity of selecting and optimizing the operating parameters. The rotational speed of the nozzle must be coupled with the transverse velocity of the nozzle as it passes across the surface of the substrate being stripped. The radial and angular positions of each orifice must be included in the analysis of the nozzle configuration. Since orifices at the outer edge of the nozzle head move at a faster rate than the orifice located near the center, the energy impact force of the water stream from the outer orifice is spread over a larger area than the water streams from the inner orifice. Utilizing a larger diameter orifice in the outer radial positions increases the energy impact to compensate for its wider force distribution. The total flow rate from the combination of orifices must be monitored and kept below the pump capacity while choosing an orifice to insert in each position. The energy distribution from the orifice pattern is further complicated since the rotary path of all orifices in the nozzle head pass through the center section, contributing to the stripping in this area while only the outer most orifice contributes to the stripping in the shell area at the extreme outside edge of the nozzle. From t he outer most shell to the center section, more orifices contribute to the stripping in each progressively reduced diameter shell. With all these parameters to configure and each parameter change affecting the others, a computer model was developed to track and coordinate these parameters. The computer simulation responds by graphically indicating the cumulative affect from each parameter selected. The results from the proper choices in parameters is a well designed, highly efficient stripping system. A poorly chosen set of parameters will cause the nozzle to strip aggressively in some areas while leaving the coating untouched in adjacent sections. The high pressure water stripping system can be set to extremely aggressive conditions allowing stripping of hard to remove adhesives, paint systems, cladding and chromate conversion coatings. The energy force can be reduced to strip coatings from thin aluminum substrates without causing damage or deterioration to the substrate's surface. High pressure water stripping of aerospace components have thus proven to be an efficient and cost effective method for cleaning and removing coatings.

Hoppe, David T.↗

Using Technical Performance Measures

All programs have requirements. For these requirements to be met, there must be a means of measurement. A Technical Performance Measure (TPM) is defined to produce a measured quantity that can be compared to the requirement. In practice, the TPM is often expressed as a maximum or minimum and a goal. Example TPMs for a rocket program are: vacuum or sea level specific impulse (lsp), weight, reliability (often expressed as a failure rate), schedule, operability (turn-around time), design and development cost, production cost, and operating cost. Program status is evaluated by comparing the TPMs against specified values of the requirements. During the program many design decisions are made and most of them affect some or all of the TPMs. Often, the same design decision changes some TPMs favorably while affecting other TPMs unfavorably. The problem then becomes how to compare the effects of a design decision on different TPMs. How much failure rate is one second of specific impulse worth? How many days of schedule is one pound of weight worth? In other words, how to compare dissimilar quantities in order to trade and manage the TPMs to meet all requirements. One method that has been used successfully and has a mathematical basis is Utility Analysis. Utility Analysis enables quantitative comparison among dissimilar attributes. It uses a mathematical model that maps decision maker preferences over the tradeable range of each attribute. It is capable of modeling both independent and dependent attributes. Utility Analysis is well supported in the literature on Decision Theory. It has been used at Pratt & Whitney Rocketdyne for internal programs and for contracted work such as the J-2X rocket engine program. This paper describes the construction of TPMs and describes Utility Analysis. It then discusses the use of TPMs in design trades and to manage margin during a program using Utility Analysis.

Garrett, Christopher J.↗

Fluid & Thermal Analysis of a Manifold Microchannel Heat Sink

A three-dimensional (3-D) numerical model has been developed to study the fluid flow and heat transfer through a manifold-microchannel (MMC) heat sink, a microfluidic cooling system designed as a heat dissipation solution for compact, high-powered electronic systems. An MMC consists of a 3-D manifold structure that distributes working fluid through alternating inlet and outlet manifold channels that guide the fluid to and from the microchannels, shortening the flow length and thereby, reducing the pressure drop across the system. Wide bandgap semiconductors such as silicon carbide (SiC) are increasingly utilized due to their ability to enable smaller electronic devices and components to operate more efficiently at higher frequencies. These semiconductors can greatly benefit from the MMC, which can extract all the heat produced by compact, high-powered electronics, enabling them to achieve optimal performance. The MMC also utilizes an embedded cooling approach which allows for fabrication directly within SiC-based electronics, resulting in significant mass and weight savings and lower thermal resistance than conventional heat sink designs. This paper outlines the methods used to conduct fluid and thermal analysis of different MMC configurations for flow parameters such as flow rate and inlet flow conditions. This study involves both steady state and transient thermal analysis as a gradually increasing heat flux is applied to the system over time, which is representative of the heat dissipation from the electronics over a given period. Results from the analysis show that the MMC is capable of effectively dissipating heat flux of ~100 W/cm2 while maintaining considerably low pressure drop (< 1 kPa) and thermal resistance (< 1 K/W) for certain single-phase working fluids.

manifold microchannel↗

Fluid & Thermal Analysis of a Manifold Microchannel Heat Sink

A three-dimensional (3-D) numerical model has been developed to study the fluid flow and heat transfer through a manifold-microchannel (MMC) heat sink, a microfluidic cooling system designed as a heat dissipation solution for compact, high-powered electronic systems. An MMC consists of a 3-D manifold structure that distributes working fluid through alternating inlet and outlet manifold channels that guide the fluid to and from the microchannels, shortening the flow length and thereby, reducing the pressure drop across the system. Wide bandgap semiconductors such as silicon carbide (SiC) are increasingly utilized due to their ability to enable smaller electronic devices and components to operate more efficiently at higher frequencies. These semiconductors can greatly benefit from the MMC, which can extract all the heat produced by compact, high-powered electronics, enabling them to achieve optimal performance. The MMC also utilizes an embedded cooling approach which allows for fabrication directly within SiC-based electronics, resulting in significant mass and weight savings and lower thermal resistance than conventional heat sink designs. This paper outlines the methods used to conduct fluid and thermal analysis of different MMC configurations for flow parameters such as flow rate and inlet flow conditions. This study involves both steady state and transient thermal analysis as a gradually increasing heat flux is applied to the system over time, which is representative of the heat dissipation from the electronics over a given period. Results from the analysis show that the MMC is capable of effectively dissipating heat flux of ~100 W/cm2 while maintaining considerably low pressure drop (< 1 kPa) and thermal resistance (< 1 K/W) for certain single-phase working fluids.

manifold microchannel↗

Representative Phenomena of Cyclic Turbulent Combustion in High-Pressure Fuel Sprays

Abstract Cyclic variations in conventional diesel combustion engines can lead to large differences in engine out emissions even at steady operation. This study uses an optically accessible constant-pressure flow chamber to acquire fuel injections in quick succession to analyze mixing, auto-ignition, and combustion of diesel-surrogate n-heptane using multiple high-speed optical diagnostics. Prior studies have utilized fewer injections and/or they rely on analysis of ensemble average behavior. These approaches do not yield information on injection-to-injection variation or provide confidence in utilizing individual injection measurements for high-fidelity computational fluid dynamics(CFD) model validation. In this study, a large set of 500 injections is used to obtain global parameters including liquid length, vapor penetration length, ignition delay time, and lift-off length. Results for multiple injections are presented to illustrate large injection to injection variations. Potential sources for these variations are analyzed to conclude localized, small scale turbulence and rate of injection variations as the likely sources. Then, a statistical method based on z-scores is proposed and implemented to identify instantaneous injections that best represent the bulk data-set of jet boundaries measured independently by three different diagnostics. This synthesis of statistics-guided screening of data set and ensemble-average analysis offers higher confidence for CFD model validation relying upon both a representative single and average injection results.

42 ENGINEERING↗

Commercial, industrial, and institutional discount rate estimation for efficiency standards analysis: Sector-level data 1998–2022

Underlying each of the U.S. Department of Energy’s (DOE’s) federal appliance and equipment energy conservation standards are a set of complex analyses of the projected costs and benefits of regulation. Any new or amended standard must be designed to achieve significant additional energy conservation, provided that it is technologically feasible and economically justified (42 U.S.C. 6295(o)(2)(A)). DOE determines economic justification based on whether the benefits exceed the burdens, considering a variety of factors, including the economic impact of the standard on consumers of the product and the savings in lifetime operating cost compared to any increase in price or maintenance expenses (42 U.S.C. 6295(o)(2)(B)). As part of this determination, DOE conducts a life-cycle cost (LCC) analysis, which models the combined impact of appliance first cost and operating cost changes on a representative commercial building sample to identify the fraction of customers achieving LCC savings or incurring net cost at the considered efficiency levels. Thus, the commercial discount rate value(s) used to calculate the present value of energy cost savings within the LCC model implicitly plays a role in estimating the economic impact of potential standard levels. This report provides an in-depth discussion of the commercial discount rate estimation process. It is an update to previous reports on estimating commercial discount rates from firm-level and sector-level financial data (e.g., Fujita, 2021, 2016). Major topics covered in this report include the following: -Discount rate estimation methods and rationale -Data sources used and data limitations -Discount rate distributions for use in standards analysis -Discount rate estimation methods and distributions specific to the small business subgroup analysis A version of this analysis was most recently released in 2022. Going forward, this report will be updated as data allow and analyses necessitate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sensitivity Analysis of Occupant Preferences on Energy Usage in Residential Buildings: Preprint

Residential buildings, accounting for 37% of the total electricity consumption in the United States, are suitable for demand-side management (DSM) programs to support effective and economical operation of the power system. A home energy management system (HEMS) enables residential buildings to participate in such programs. It is important to account for occupant preferences in HEMS to ensure occupant satisfaction while participating in DSM programs. For example, people who prefer a higher thermal comfort level are likely to consume more energy. In this study, we used foresee™, a HEMS developed by the National Renewable Energy Lab (NREL), to perform a sensitivity analysis of occupant preferences with the following objectives: minimize utility cost, minimize carbon footprint, and maximize thermal comfort. To incorporate the preferences into the HEMS, the SMARTER method was used to derive a set of weighting factors for each objective. We performed week-long building energy simulations using a model of a home in Fort Collins, Colorado, where there is mandatory time-of-use electricity rate structure. The foreseeTM HEMS was used to control the home with six different sets of occupant preferences. The study shows that occupant preferences can have a significant impact and is important to consider when modeling residential buildings. Results show that the HEMS could achieve energy reduction ranging from 3% to 21%, cost savings ranging from 5% to 24%, and carbon emission reduction ranging from 3% to 21%, while maintaining a low thermal discomfort level ranging from 0.78 K-hour to 6.47 K-hour in a one-week period during winter. These outcomes quantify the impact of varying occupant preferences and will be useful for controlling the electrical grid and developing HEMS solutions.

carbon footprint↗

Development of image processing techniques for applications in flow visualization and analysis

A comparison between two flow visualization studies of an axi-symmetric circular jet issuing into still fluid, using two different experimental techniques, is described. In the first case laser induced fluorescence is used to visualize the flow structure, whilst smoke is utilized in the second. Quantitative information was obtained from these visualized flow regimes using two different digital imaging systems. Results are presented of the rate at which the jet expands in the downstream direction and these compare favorably with the more established data.

Disimile, Peter J.↗

Will Consumers Really Pay for Green Electricity? Comparing Stated and Revealed Preferences for Residential Programs in the United States

Public support is growing for policy initiatives to spur a transition from a fossil to renewable energy portfolio in the electricity sector. Some utilities in the United States offer programs that allow consumers to voluntarily pay premiums (0.1-7.0 cents/kWh) for electricity from renewable sources. However, it is unclear whether public support translates to paying for green electricity if given the option. Our analysis employs data from two national, longitudinal surveys on energy attitudes and willingness to pay for renewables to investigate whether environmental concerns and stated preferences for renewable energy translate to consumer behavior as measured through ratepayer participation in voluntary utility renewable energy programs known as utility green pricing. We find higher green pricing program participation rates in areas where consumers have stronger feelings about the environmental impacts of energy. Consumers in high-participation areas also have a higher stated willingness to pay for renewable energy, on average, than consumers in low-participation areas. We also find income, homeownership, and home value explain some of the difference between high- and low-participation programs. Further, program participation is lower in areas where utilities charge higher green pricing program premiums. These findings suggest that green power programs - such as utility green pricing - offer a market-based mechanism for consumers to realize their desire to purchase renewable energy. Policymakers may use these results to support further expansion of green power programs in areas where customers currently lack accessible and affordable options to act on their environmental beliefs and concerns.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Exploring Demographic Factors Behind the User Preferences in Ridesharing Services

Ridesharing is an increasingly prevalent form of transportation. Personal and pooled rideshare services are the two modes of ridesharing available on the market. While personal rideshare features higher time efficiency and better service experience, especially in terms of privacy, pooled rideshare has better energy efficiency and can reduce traffic congestion. To encourage users to utilize pooled rideshare, it is crucial to understand the factors behind preferences between pooled and personal rideshare services. This study conducted a survey study on a sample of 2,884 participants from the U.S. The stated-choice method was employed to collect the usage rate of pooled rideshare in designed scenarios. A detailed analysis of pooled rideshare usage rates among participants from different demographic backgrounds was performed. The results demonstrated demographic factors related to variations in pooled rideshare usage rates. Findings from this study explore the impacts of demographic factors on people's choices in ridesharing and provide important information for the modeling and optimization of ridesharing transportation systems.

Su, Haotian↗