Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tunable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

HO2 detection by near infrared absorption using tunable diode lasers

The strongest absorption lines are in the v sub 2 vibrational band around 1400/cm; several near-coincident line pairs in this region provide max linestrengths of 1.2 x 10 exp -20 sq. cm/(molecule*cm). High Frequency wavelength modulation coupled with sweep integration were used to minimize noise and maintain spectral discrimination. Reduced pressure sampling was performed using supersonic nozzle and an aerodynamic flow cell to minimize residence time and wall losses of radicals. The astigmatic mirror design provides pathlengths up to 200 m in volume of 3 liters with minimal optical interference fringes; longer pathlengths are possible. The detection limit depends on pathlength and minimum fractional absorptions.

Nelson, David↗

Three-parameter tunable Tilt-Integral-Derivative (TID) controller

A feedback control system compensator of the PID type is provided, wherein the proportional component of the compensator is replaced with a tilted component having a transfer function s to the power of -1/n. The resulting transfer function of the entire compensator more closely approximates an optimal transfer function, thereby achieving improved feedback controller. Further, as compared to conventional PID compensators, the TID compensator allows for simpler tuning, better disturbance rejection ratio, and smaller effects of plant parameter variations on closed loop response.

Lurie, Boris J.↗

Atomic oxygen fluorescence excitation using a Raman-shifted, tunable ArF-excimer laser

A novel method for exciting the two-photon, 2p3 3p 3P left arrow 2p4 3P atomic oxygen transition is reported. The transition to the upper state is achieved through the combined absorption of photons from the second and third Stokes order pulses of an ArF-excimer laser that is wavelength-shifted by the use of deuterium Raman cell. All three transitions from the ground electronic state of the oxygen atom lie within the tuning range of the Raman-shifted ArF laser. The available pulse energy from this laser configuration is comparable to that of commercially available Nd:YAG-pumped dye laser systems operated at 226 nm.

Fletcher, D. G.↗

Eddy correlation measurements of methane fluxes using a tunable diode laser at the Kinosheo Lake tower site during the Northern Wetlands Study (NOWES)

As part of the Canadian Northern Wetlands Study (NOWES) measurements of methane flux were made at the Kinosheo Lake tower site for a 1-month period during the 1990 summer intensive. The measurements were made with a diode-laser-based methane sensor using the eddy correlation technique. Measurements of the methane fluxes were made at two levels, 5 or 18 m. Approximately 900 half-hour average methane flux measurements were obtained. Weak temporal and diurnal trends were observed in the data. Fluxes averaged over the study period showed an overall methane emission of 16 mg CH4 m(exp -2)/d with a daytime average of 20 mg CH4 m(exp -2)/d and a nighttime average of 9 mg CH4 m(exp -2)/d. The effect of emission footprint was evident in the data. A strong relationship between the daily average methane flux and wet bog temperature at 20-cm depth was observed.

Edwards, G. C.↗

Photodissociation Cross Sections for the Production of C2 from C2H Using Laser Induced Hg Photosensitization and Tunable Ultraviolet and Visible Lasers

The principle goal of our research was to understand the formation of free radicals in comets. To do this we compared laboratory results with cometary observations in attempt to make sure that the cometary observations agree with what is known about the photochemistry of the proposed parent molecule. Initially we concentrated on the CS emission in an effort to show the parent of this molecule was CS2, consistent with cometary observations of the photochemical lifetime. We then started to look into the problem of the C2 formation in comets. We set out to see if we could measure all of the nascent distributions of the C2 products in the hope that they would be a characteristic signature of the formation process.

Jackson, William M.↗

Ultrahigh-efficiency, very narrow-passband, tunable optical filter

Recently developed technologies have been uniquely integrated to produce optical filters with unprecedented performance. The precise design and fabrication of narrow-passband and high-efficiency optical filters with a central frequency of 532 nm are reported. Measurements with these filters demonstrate a performance that accurately mirrors the design specification, with one filter having a passband of 70 pm and an efficiency greater than 90% and the second filter having a passband of 7 pm and an efficiency greater than 80%.

Sandford, Stephen P.↗

Tunable UV Filters

This report describes an investigation intended to determine the practical short wavelength limit for Fabry-Perot etalons operating in the far ultraviolet. This portion of the investigation includes a design study of multilayer dielectric reflector coatings that would be required by such an etalon. Results of the study indicate that etalons may be made to operate at wavelengths as short as 121 nm.

Bruner, Marilyn E.↗

Micro-Mechanical Voltage Tunable Fabry-Perot Filters Formed in (111) Silicon

The MEMS (Micro-Electro-Mechanical-Systems) technology is quickly evolving as a viable means to combine micro-mechanical and micro-optical elements on the same chip. One MEMS technology that has recently gained attention by the research community is the micro-mechanical Fabry-Perot optical filter. A MEMS based Fabry-Perot consists of a vertically integrated structure composed of two mirrors separated by an air gap. Wavelength tuning is achieved by applying a bias between the two mirrors resulting in an attractive electrostatic force which pulls the mirrors closer. In this work, we present a new micro-mechanical Fabry-Perot structure which is simple to fabricate and is integratable with low cost silicon photodetectors and transistors. The structure consists of a movable gold coated oxide cantilever for the top mirror and a stationary Au/Ni plated silicon bottom mirror. The fabrication process is single mask level, self aligned, and requires only one grown or deposited layer. Undercutting of the oxide cantilever is carried out by a combination of RIE and anisotropic KOH etching of the (111) silicon substrate. Metallization of the mirrors is provided by thermal evaporation and electroplating. The optical and electrical characteristics of the fabricated devices were studied and show promissing results. A wavelength shift of 120nm with 53V applied bias was demonstrated by one device geometry using 6.27 micrometer air gap. The finesse of the structure was 2.4. Modulation bandwidths ranging from 91KHz to greater than 920KHz were also observed. Theoretical calculations show that if mirror reflectivity, smoothness, and parallelism are improved, a finesse of 30 is attainable. The predictions also suggest that a reduction of the air gap to 1 micrometer results in an increased wavelength tuning range of 175 nm with a CMOS compatible 4.75V.

Patterson, James D.↗

Temperature Tunable Air-Gap Etalon Filter

We report on experimental measurements of a temperature tuned air-gap etalon filter. The filter exhibits temperature dependent wavelength tuning of 54 pm/C. It has a nominal center wavelength of 532 nm. The etalon filter has a 27 pm optical bandpass and 600 pm free spectral range (finesse approximately 22). The experimental results are in close agreement with etalon theory.

Krainak, Michael A.↗

Tunable Far Infrared Studies in Support of Stratospheric Measurements

The research performed during this reporting period has been a collaboration between institutions including the Smithsonian Astrophysical Observatory, the National Institute of Standards and Technology, the University of Oregon, and the NASA Langley Research Center. The program has included fully line-resolved measurements of submillimeter and far infrared spectroscopic line parameters (pressure broadening coefficients and their temperature dependences, and fine positions) for the analysis of field measurements of stratospheric constituents, far infrared database improvements, and studies for improved satellite measurements of the Earth's atmosphere. This research program is designed to enable the full utilization of spectra obtained in far infrared/submillimeter field measurements, such as FIRS-2, FILOS, IBEX, SLS, EosMLS, and proposed NASA and European Space Agency measurements of ClO and OH (e.g., PIRAMHYD) for the retrieval of accurate stratospheric altitude profiles of key trace gases involved in ozone layer photochemistry.

Chance Kelly↗

A Compact, Tunable Near-UV Source for Quantitative Microgravity Combustion Diagnostics

There is a need for improved optical diagnostic methods for use in microgravity combustion research. Spectroscopic methods with fast time response that can provide absolute concentrations and concentration profiles of important chemical species in flames are needed to facilitate the understanding of combustion kinetics in microgravity. Although a variety of sophisticated laser-based diagnostics (such as planar laser induced fluorescence, degenerate four wave mixing and coherent Raman methods) have been applied to the study of combustion in laboratory flames, the instrumentation associated with these methods is not well suited to microgravity drop tower or space station platforms. Important attributes of diagnostic systems for such applications include compact size, low power consumption, ruggedness, and reliability. We describe a diode laser-based near-UV source designed with the constraints of microgravity research in mind. Coherent light near 420 nm is generated by frequency doubling in a nonlinear crystal. This light source is single mode with a very narrow bandwidth suitable for gas phase diagnostics, can be tuned over several 1/cm and can be wavelength modulated at up to MHz frequencies. We demonstrate the usefulness of this source for combustion diagnostics by measuring CH radical concentration profiles in an atmospheric pressure laboratory flame. The radical concentrations are measured using wavelength modulation spectroscopy (WMS) to obtain the line-of-sight integrated absorption for different paths through the flame. Laser induced fluorescence (LIF) measurements are also demonstrated with this instrument, showing the feasibility of simultaneous WMS absorption and LIF measurements with the same light source. LIF detection perpendicular to the laser beam can be used to map relative species densities along the line-of-sight while the integrated absorption available through WMS provides a mathematical constraint on the extraction of quantitative information from the LIF data. Combining absorption with LIF - especially if the measurements are made simultaneously with the same excitation beam - may allow elimination of geometrical factors and effects of intensity fluctuations (common difficulties with the analysis of LIF data) from the analysis.

Peterson, K. A.↗

Electrically-Tunable Group Delays Using Quantum Wells in a Distributed Bragg Reflector

There is a growing interest in the fabrication of semiconductor optical group delay lines for the development of phased arrays of Vertical-Cavity Surface-Emitting Lasers (VCSELs). We present a novel structure incorporating In(x)GA(1-x)As quantum wells in the GaAs quarter-wave layers of a GaAs/AlAs distributed Bragg reflector (DBR). Application of an electric field across the quantum wells leads to red shifting and peak broadening of the el-hhl exciton peak via the quantum-confined Stark effect. Resultant changes in the index of refraction thereby provide a means for altering the group delay of an incident laser pulse. We discuss the tradeoffs between the maximum amount of change in group delay versus absorption losses for such a device. We also compare a simple theoretical model to experimental results, and discuss both angle and position tuning of the BDR band edge resonance relative to the exciton absorption peak. The advantages of such monolithically grown devices for phased-array VCSEL applications will be detailed.

Nelson, Thomas R., Jr.↗

Tunable Far Infrared Studies in Support of Stratospheric Measurements

This report summarizes research done under NASA Grant NAG5-4653. The research performed under this grant has been a collaboration between institutions including the Smithsonian Astrophysical Observatory, the National Institute of Standards and Technology, the University of Oregon, and the NASA Langley Research Center. The program has included fully line-resolved measurements of submillimeter and far infrared spectroscopic line parameters (pressure broadening coefficients and their temperature dependences, and line positions) for the analysis of field measurements of stratospheric constituents, far infrared database improvements, and studies for improved satellite measurements of the Earth's atmosphere. This research program is designed to enable the full utilization of spectra obtained in far infrared/submillimeter field measurements, such as FIRS-2, FILOS, IBEX, SLS, EosMLS, and proposed European Space Agency measurements of OH (e.g., PIRAMHYD and SFINX) for the retrieval of accurate stratospheric altitude profiles of key trace gases involved in ozone layer photochemistry. For the analysis of the spectra obtained in the stratosphere from far infrared measurements it is necessary to have accurate values of the molecular parameters (line positions, strengths, and pressure broadening coefficients) for the measured molecules and for possible interfering species. Knowledge of line positions is in increasingly good shape, with some notable exceptions. The increase in position information includes research that has been performed in the present program of research on HO2, H2O, H2O2, O3, HCl, HF, HBr, HI, CO, OH, and ClO. Examples where further line position studies are necessary include hot band and minor isotopomer lines of some of the major trace species (H2O, O3) and normal lines of some triatomic and larger molecules (NO2). Knowledge of strengths is in generally good shape, since most of the lines are from electric dipole transitions whose intensities are well determined from Stark effect measurements; exceptions include some molecules with large vibration-rotation interactions (NO2) and internal motions (H2O2 above the lowest torsional state). The line parameters that are still the least well determined are pressure broadening coefficients, and their temperature coefficients, These are strongly dependent on the quantum states involved in the transitions, in a way that is much more complex than the simple projection by directional cosine matrix elements involved in determination of rotational line strengths from static dipole moments. The following molecules have now been measured or detected in the atmosphere using far infrared and millimeter-wave emission spectroscopy from balloon- and satellite-borne spectrometers: OH, HO2, H2O (including minor isotopomers and hot band lines), H2O2, O3P, O2 (including minor isotopomers), O3 (including minor isotopomers and hot band lines), HOCl, HCl, HF, HBr, CIO, CO, CO2, N2O, NO2, N2O5, HNO3, ClNO3, and HCN. Many of these species have spectral lines that are saturated in stratospheric spectra. In these cases, the measured line equivalent widths are proportional to (line strength x Lorentz width) (exp 1/2) so that the pressure broadening coefficients are as important as the line intensities in determining concentration profiles. Interpretation of field measurements for these species have required ongoing measurement programs of pressure broadening measurements. Other species (HO2, HGCl, H2O2, HBr, and NO2, as examples) have required further line position studies in order to fully analyze the field measurements.

Chance, Kelly V.↗

High Precision Wavelength Monitor for Tunable Laser Systems

A solid-state apparatus for tracking the wavelength of a laser emission has a power splitter that divides the laser emission into at least three equal components. Differing phase shifts are detected and processed to track variations of the laser emission.

Mark E Froggatt↗

The Tunable XUV Imager (TXI) Sounding Rocket Payload

The TXI was flown successfully on 21 June 2001 (36.199 US). All systems functioned as planned and image data were acquired and sent to the ground. Unfortunately, due to a parachute failure the payload was destroyed. In this report we summarize results from the flight and provide detailed information on the high resolution X-ray imaging detector which was developed as part of the program.

Brinton, John↗

Line Tunable Ultraviolet Laser

An ultraviolet laser is demonstrated using a dual wavelength Nd:YAG oscillator, sum frequency and second harmonic process. Synchronous pulses at 1.052 and 1.319 micrometers are amplified, mixed and subsequently doubled, producing pulses at 0.293 micrometers.

Walsh, Brian M.↗

Ferroelectric/Semiconductor Tunable Microstrip Patch Antenna Developed

A lithographically printed microwave antenna that can be switched and tuned has been developed. The structure consists of a rectangular metallic "patch" radiator patterned on a thin ferroelectric film that was grown on high-resistivity silicon. Such an antenna may one day enable a single-phased array aperture to transmit and receive signals at different frequencies, or it may provide a simple way to reconfigure fractal arrays for communications and radar applications.

Romanofsky, Robert R.↗

Aerosol climatology using a tunable spectral variability cloud screening of AERONET data

Can cloud screening of an aerosol data set, affect the aerosol optical thickness (AOT) climatology? Aerosols, humidity and clouds are correlated. Therefore, rigorous cloud screening can systematically bias towards less cloudy conditions, underestimating the average AOT. Here, using AERONET data we show that systematic rejection of variable atmospheric optical conditions can generate such bias in the average AOT. Therefore we recommend (1) to introduce more powerful spectral variability cloud screening and (2) to change the philosophy behind present aerosol climatologies: Instead of systematically rejecting all cloud contaminations, we suggest to intentionally allow the presence of cloud contamination, estimate the statistical impact of the contamination and correct for it. The analysis, applied to 10 AERONET stations with approx. 4 years of data, shows almost no change for Rome (Italy), but up to a change in AOT of 0.12 in Beijing (PRC). Similar technique may be explored for satellite analysis, e.g. MODIS.

Kaufman, Yoram J.↗