Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “temperature sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

LiG Metrology, Correlated Error, and the Integrity of the Global Surface Air-Temperature Record

The published 95% uncertainty of the global surface air-temperature anomaly (GSATA) record through 1980 is impossibly less than the 2σ = ±0.25 °C lower limit of laboratory resolution of 1 °C/division liquid-in-glass (LiG) thermometers. The ~0.7 °C/century Joule-drift of lead- and soft-glass thermometer bulbs renders unreliable the entire historical air-temperature record through the 19th century. A circa 1900 Baudin meteorological spirit thermometer bulb exhibited intense Pb X-ray emission lines (10.55, 12.66, and 14.76 keV). Uncorrected LiG thermometer non-linearity leaves 1σ = ±0.27 °C uncertainty in land-surface air temperatures prior to 1981. The 2σ = ±0.43 °C from LiG resolution and non-linearity obscures most of the 20th century GSATA trend. Systematic sensor-measurement errors are highly pair-wise correlated, possibly across hundreds of km. Non-normal distributions of bucket and engine-intake difference SSTs disconfirm the assumption of random measurement error. Semivariogram analysis of ship SST measurements yields half the error difference mean, ±½Δε 1,2, not the error mean. Transfer-function adjustment following a change of land station air-temperature sensor eliminates measurement independence and forward-propagates the antecedent uncertainty. LiG resolution limits, non-linearity, and sensor field calibrations yield GSATA mean ±2σ RMS uncertainties of, 1900–1945, ±1.7 °C; 1946–1980, ±2.1 °C; 1981–2004, ±2.0 °C; and 2005–2010, ±1.6 °C. Finally, the 20th century (1900–1999) GSATA, 0.74 ± 1.94 °C, does not convey any information about rate or magnitude of temperature change.

54 ENVIRONMENTAL SCIENCES↗

Electrical, structural and thermomechanical properties of doped-LaCrO3 ceramics for high temperature electronics and sensing applications.

Many important electrical and sensor applications require stable conductors under working temperatures up to 1500oC various redox environments. Common high temperature conductors such as nitrides and carbides are not stable under oxidizing atmospheres, for this reason low redox behavior materials would be more attractive. In this work, further dopant studies of the LaCrO3 system were completed in order to control the electronic and ionic conductivity, as well as the relative chemical and microstructural stability. Neodymium and Niobium dopants were initially studied to control the p-type, and potentially n-type conductive mechanisms, respectively, but other dopants strategies were also investigated. The electrical conductivity and Seebeck coefficient were characterized up to 1500oC under varying oxygen partial pressures. The phase and microstructural evolution of each material was also investigated for these compositions by XRD and SEM. The materials showing the best electrical and thermomechanical performance were included within thick films sensors and were tested.

20 FOSSIL-FUELED POWER PLANTS↗

Large Language Model for Validation, Optical Calibration, and Learning (VOCAL) Distributed Temperature Sensing Interface

Distributed temperature sensing (DTS) using fiber optic sensors (FOS) offers a promising method for temperature measurements in advanced reactors, such as sodium fast reactors and molten salt cooled reactors. To support the calibration and validation of DTS measurements, Argonne National Laboratory developed the Validation, Optical Calibration, and Learning (VOCAL) software package. This report describes the integration of a local large language model (LLM) with a retrieval-augmented generation (RAG) system into the VOCAL interface to serve as an interactive user assistant. The LLM framework enhances the VOCAL platform’s accessibility to users by explaining interface components, clarifying inputs and outputs, and answering user queries dynamically in real-time. The accuracy of the LLM assistant performance was evaluated with 20 queries regarding the interface and its parameters using experimental data from the Thermal Hydraulic Experimental Test Article (THETA) facility. Results demonstrate that the LLM achieved a 95% accuracy rate, with a BERTScore of 0.8816 and SBERT value of 0.7417. Furthermore, validation of the RAG system within the LLM framework showed optimal accuracy with k-values between 1 and 2 using the k-refinement convergence test. The prompt perturbation analysis demonstrated good initial consistency for the RAG system, exhibiting the highest accuracy under punctuation variations and the greatest sensitivity under query reordering. Notably, the model’s errors were limited to data retrieval failures rather than factual hallucinations, reinforcing its baseline reliability. The integration of LLM provides a highly accurate, userfriendly enhancement to the VOCAL platform without disrupting its core computational capabilities for FOS calibration and validation.

Hong, Evan↗

Ultralow-temperature cryogenic transmission electron microscopy using a new helium flow cryostat stage

Advances in cryogenic electron microscopy have opened new avenues for probing quantum phenomena in correlated materials. This study reports the installation and performance of a new side-entry condenZero cryogenic cooling system for JEOL (Scanning) Transmission Electron Microscopes (S/TEM), utilizing compressed liquid helium (LHe) and designed for imaging and spectroscopy at ultra-low temperatures. The system includes an external dewar mounted on a vibration-damping stage and a pressurized, low-noise helium transfer line with a remotely controllable needle valve, ensuring stable and efficient LHe flow with minimal thermal and mechanical noise. Performance evaluation demonstrates a stable base temperature of 4.37 K measured using a Cernox bare chip sensor on the holder with temperature fluctuations within ±0.004 K. Complementary in-situ electron energy-loss spectroscopy (EELS) via aluminum bulk plasmon analysis was used to measure the local specimen temperature and validate cryogenic operation during experiments. The integration of cryogenic cooling with other microscopy techniques, including electron diffraction and Lorentz TEM, was demonstrated by resolving charge density wave (CDW) transitions in NbSe2 using electron diffraction, and imaging nanometric magnetic skyrmions in MnSi via Lorentz TEM. In conclusion, this platform provides reliable cryogenic operation below 7 K, establishing a low-drift route for direct visualization of electronic and magnetic phase transformations in quantum materials.

Charge density wave↗

Housing apparatus for sensitive gas sensor

A sensor housing apparatus includes a housing having an enclosure and outer assembly, at least one flow path extending through the housing, a gas sensor disposed in the enclosure and a thermal mass. The thermal mass is mounted within the enclosure in thermal communication with the gas sensor, and is configured to transfer thermal energy from the gas sensor to an ambient environment surrounding the housing and minimize temperature gradients adjacent the gas sensor.

42 ENGINEERING↗

Housing apparatus for sensitive gas sensor

A sensor housing apparatus includes a housing having an enclosure and outer assembly, at least one flow path extending through the housing, a gas sensor disposed in the enclosure and a thermal mass. The thermal mass is mounted within the enclosure in thermal communication with the gas sensor, and is configured to transfer thermal energy from the gas sensor to an ambient environment surrounding the housing and minimize temperature gradients adjacent the gas sensor.

Martin, Yves C.↗

Characterization of the polysilicon resistor in silicon strip sensors for ATLAS inner tracker as a function of temperature, pre- and post-irradiation

The high luminosity upgrade of the Large Hadron Collider, foreseen for 2029, requires the replacement of the ATLAS Inner Detector with a new all-silicon Inner Tracker (ITk). The expected ultimate total integrated luminosity of 4000 fb –1 means that the strip part of the ITk detector will be exposed to the total particle fluences and ionizing doses reaching the values of 1.6 · 10 15 1 MeV n eq /cm 2 and 0.66 MGy, respectively, including a safety factor of 1.5. Radiation hard n + -in-p micro-strip sensors were developed by the ATLAS ITk strip collaboration and are produced by Hamamatsu Photonics K.K. The active area of each ITk strip sensor is delimited by the n-implant bias ring, which is connected to each individual n + implant strip by a polysilicon bias resistor. The total resistance of the polysilicon bias resistor should be within a specified range to keep all the strips at the same potential, prevent the signal discharge through the grounded bias ring and avoid the readout noise increase. While the polysilicon is a ubiquitous semiconductor material, the fluence and temperature dependence of its resistance is not easily predictable, especially for the tracking detector with the operational temperature significantly below the values typical for commercial microelectronics. Dependence of the resistance of polysilicon bias resistor on the temperature, as well as on the total delivered fluence and ionizing dose, was studied on the specially-designed test structures called ATLAS Testchips, both before and after their irradiation by protons, neutrons, and gammas to the maximal expected fluence and ionizing dose. The resistance has an atypical negative temperature dependence. It is different from silicon, which shows that the grain boundary has a significant contribution to the resistance. Finally, we discuss the contributions by parameterizing the activation energy of the polysilicon resistance as a function of the temperature for unirradiated and irradiated ATLAS Testchips.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lab-on-a-Fish Monitoring Software V1.0

This is the original monitoring software for processing and displaying data for Lab-on-a-Fish. Lab-on-a-Fish simultaneously evaluates and monitors the health, behavior, and environment of fish or small aquatic species. The sensor is a miniaturized underwater monitoring system that measures animal behavior (acceleration and gyration); physiology (electrocardiogram and electromyogram); and environmental parameters (temperature, pressure, and magnetic sensor).

Deng, Daniel↗

Continuous soil temperature and soil deformation measurements, Teller road Mile 47, Nome, Alaska.

The dataset comprises Soil Temperature and Deformation monitoring data gathered from a watershed situated along the Nome-Teller road at Mile 47 in Alaska. Its primary objective is to enhance comprehension of deformation mechanisms in permafrost environments by using 51 probes designed following Wielandt et al. (2022). The dataset comprises a description of Probe_ID, Location, start time, end time and probe length in the "ProbesLocations_StartEndDates.csv" file, the 51 data files encapsulated within "Data_files.zip" and the computed deformation for 2023 and 2022 in "Deformation_T47.zip".Each file in Data_files.zip is named as followed "ProbeId_StartMonth_EndMonth.csv". Within each file, the initial column denotes the timestamp in UTC, followed by the sensor’s battery voltage and temperature and acceleration values (X, Y, Z) in subsequent columns. The data collection frequency is set at 30-minute intervals. Each file in Deformation_T47.zip is named as followed "ProbeId_Temp_def_year.csv". Within each file, the initial column denotes the timestamp in UTC, followed by the temperature at each sensor and cumulative deformation from last to first sensor in subsequent columns. The data collection is daily averaged.This dataset forms an integral component of the Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic). The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Status Update on the Development of Transducers and Bonding Techniques for Enabling Acoustic Measurements of Damage in Microreactor Components

This report provides an overview of potential sensors and sensor-bonding techniques to enable the online acoustic interrogation of microreactor components and enhance structural health monitoring capabilities. The report focuses primarily on optical fiber–based acoustic sensors and describes initial experimental progress toward the deployment of these sensors for microreactor applications. The general approach is to monitor the resonant frequencies of microreactor components and search for evidence of structural defects that could indicate imminent failure. If properly identified, then the components could be repaired during the next reactor outage to prevent costly unplanned shutdowns. The ability to monitor the structural health of components could also reduce the need for time-consuming visual inspections and reduce staffing to improve microreactor economic viability. Increased sensor density is also one of the first steps to moving toward eventual semiautonomous operation. The expected microreactor conditions in which acoustic sensors must survive are characterized, including temperatures, neutron fluences, thermomechanical strains, and vibrational frequencies. Optical fiber–based acoustic sensors are identified as an attractive candidate for acoustic monitoring because of their high accuracy, immunity to electromagnetic interference, and resiliency in high-temperature, high-radiation environments. Optical fiber–based intrinsic sensors, such as type-II fiber-Bragg gratings and Fabry-Pérot Cavities (FPCs), are particularly attractive for a microreactor environment because of their high temperature stability, and FPCs also enable higher frequency interrogation with a lower sensitivity to radiation-induced drift. This report describes multiple interrogation systems, but the best interrogation system for a given situation will depend on the specific microreactor application, including the desired acoustic vibrational amplitudes, modes, and resonant frequencies. Initial experiments included fabricating three FPCs, tack-welding these FPCs to stainless-steel pipes or rods and performing room-temperature acoustic sensing tests to capture the vibrational frequency content. Peaks were identified in the measured frequency spectra and compared with the theoretical fundamental frequencies obtained from Euler-Bernoulli beam theory. Two of the three FPCs measured vibrational frequencies that generally matched those obtained from theory. Future work will include similar testing on pipes or other microreactor components with intentional flaws to evaluate the ability to determine changes in resonant frequencies. Finally, these tests will be repeated at high temperatures, potentially with an applied thermomechanical stress, to include environmental conditions similar to those for a microreactor application.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Nuclear quadrupole resonance spectroscopy with a femtotesla diamond magnetometer

Radio frequency (RF) magnetometers based on nitrogen vacancy centers in diamond are predicted to offer femtotesla sensitivity, but previous experiments were limited to the picotesla level. We demonstrate a femtotesla RF magnetometer using a diamond membrane inserted between ferrite flux concentrators. The device provides ~300-fold amplitude enhancement for RF magnetic fields from 70 kHz to 3.6 MHz, and the sensitivity reaches ~70 fT√s at 0.35 MHz. The sensor detected the 3.6-MHz nuclear quadrupole resonance (NQR) of room-temperature sodium nitrite powder. The sensor’s recovery time after an RF pulse is ~35 μs, limited by the excitation coil’s ring-down time. The sodium-nitrite NQR frequency shifts with temperature as -1.00±0.02 kHz/K, the magnetization dephasing time is T 2 *=887±51 μs, and multipulse sequences extend the signal lifetime to 332±23 ms, all consistent with coil-based studies. Our results expand the sensitivity frontier of diamond magnetometers to the femtotesla range, with potential applications in security, medical imaging, and materials science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanophotonic quantum sensing with engineered spin-optic coupling

Nitrogen vacancy centers in diamond provide a spin-based qubit system with long coherence time even at room temperature, making them suitable ambient-condition quantum sensors for quantities including electromagnetic fields, temperature, and rotation. The optically addressable level structures of NV spins allow transduction of spin information onto light-field intensity. The sub-optimal readout fidelity of conventional fluorescence measurement remains a significant drawback for room-temperature ensemble sensing. Here, we discuss nanophotonic interfaces that provide opportunities to achieve near-unity readout fidelity based on IR absorption via resonantly enhanced spin-optic coupling. Spin-coupled resonant nanophotonic devices are projected to particularly benefit applications that utilize micro- to nanoscale sensing volume and to outperform present methods in their volume-normalized sensitivity.

42 ENGINEERING↗

Data & Code from Phoenix CPPP Phase 2 Analysis

This data and code package supports the analysis presented in “Beyond Surface Cooling: Comprehensive Field Assessment of Reflective Pavement Thermal Performance in Phoenix, Arizona” and provides fully reproducible workflows for evaluating the thermal performance of cool pavement treatments in a hot urban environment. The dataset integrates multi-modal field measurements collected across residential and nonresidential settings, including mobile air temperature traverses, stationary air temperature monitoring, residential mean radiant temperature (MRT) measurements, subsurface temperature profiles, and controlled testbed observations. The data package contains raw and processed datasets in comma-separated value (CSV) format, accompanying metadata files describing site characteristics and measurement protocols, and R scripts (.R files) used for data cleaning, time synchronization, spatial and temporal matching, quality control filtering, statistical comparison, and figure generation. All analyses were conducted using R (version ≥ 4.2.0) with commonly available packages (e.g., tidyverse, lubridate, data.table, ggplot2). No proprietary software is required to reproduce results. Field campaigns were designed to quantify the effects of high-reflectance pavement coatings on surface temperature, near-surface air temperature, subsurface heat propagation, and radiative heat exposure. Temporal alignment procedures include standardized timestamp conversion and nearest-neighbor matching of high-frequency sensor measurements to stop-based metadata within defined tolerance windows to ensure comparability across instruments. The workflows generate summary statistics, treatment–control contrasts, depth-dependent thermal gradients, and time-series visualizations used in the associated publication. By integrating mobile, stationary, radiative, and subsurface measurements within a unified and transparent processing framework, this package enables comprehensive evaluation of cool pavement performance across multiple thermal exposure pathways and supports reuse in future urban heat mitigation and climate resilience studies.

AIR TEMPERATURE↗

Integrating fiber optic sensors into metallic components for sensing in harsh environments

The integration of fiber optic sensors into high-temperature materials is critical for real-time monitoring and autonomous operation of engineering systems. This study demonstrated a spark plasma sintering (SPS)-assisted embedding process for integrating sapphire fiber optic sensors into stainless steel components during part fabrication. Optical fibers were encapsulated in stainless steel 316L powders which were sintered at different fabrication conditions using SPS to investigate the effects of sintering parameters on the embedment. Measurements of optical transmittance, combined with microstructural analysis (X-ray computed tomography and scanning electron microscopy) and mechanical testing (tensile and microhardness), were conducted to examine the fiber functionality, fiber–matrix bonding quality, and properties of the sintered materials. Here, the results show that under suitable fabrication conditions, intact optical fibers can be encapsulated in highly-densified (>98 % relative density) stainless steel components. These conditions also led to a good bond at the fiber–matrix interface with micron-sized material interdiffusion across the interface. The sintering parameters were observed to affect fiber optical attenuation, where high temperature, pressure, and hold time during SPS enhanced fiber–matrix bonding and adversely affected optical transmission. Tensile testing confirmed the superior tensile strength and ductility of the matrix fabricated by SPS. Furthermore, the materials exhibited limited strength reduction (~70 MPa) upon the integration of fibers. This study demonstrates the effectiveness of SPS for fiber-material integration for high-temperature applications.

36 MATERIALS SCIENCE↗

Thermocouple Testing in Support of the AGR-5/6/7 Experiment

This report documents thermocouple testing performed in IRC Lab C-15 over a period of seven years. This testing supported selection and characterization of the thermocouple set used in the AGR-5/6/7 experiment. The following summary was taken directly from the report. Temperature measurement is a challenging aspect of very high temperature irradiation experiments because commonly used high-temperature commercial thermocouples such as platinum-rhodium (Types S, R, and B) and tungsten-rhenium (Type C), suffer dramatic drift because of neutron-induced transmutation. As a result, these types of thermocouples, which are used routinely for industrial temperature measurements outside of reactors, are used only in very special circumstances for reactor experiments. Conversely, because of their low neutron cross-sections, Type N thermocouples are affected to only a limited extent by neutron irradiation. However, the use of these nickel-based thermocouples is limited when the temperature exceeds 1050°C due to drift arising from minor alloying elements migrating from the thermocouple's metal sheath to the thermoelements. This change in the composition of the thermo-elements results in significant decalibration of the signal. The issues described above were recognized during the early planning stages of the final AGR experiment (designated AGR-5/6/7), and a thermocouple furnace testing program was performed over a seven-year period (2014-2019, 2021) to first select and then characterize the best thermocouple set for the high temperature regions of the AGR-5/6/7 irradiation experiment. The calculated temperature range of the AGR-5/6/7 experiment was 600–1500°C. For temperatures below 1000°C standard Type N thermocouples were deemed adequate. The furnace testing campaign identified two thermocouple types suitable for measuring temperatures above 1000°C, a Mo/Nb thermocouple developed at INL called HTIR-TC, and a Type N thermocouple developed by Cambridge University (called herein Cambridge Type N), which featured a custom high nickel alloy sheath. One of the original goals of the furnace testing program was to identify a thermocouple capable of low drift operation near the peak temperature expected in AGR-5/6/7, i.e., about 1400°C. The HTIR-TC design appeared promising in this regard, however a manufacturing difficulty proved to be a barrier and instead the furnace testing focused on drift performance at 1250°C. The manufacturing difficulty was that the Nb sheaths of the HTIR-TCs experienced extreme embrittlement when heat treated at 1600°C or greater. Heat treatment is needed to stabilize the emf output of this TC type, and the higher the heat treatment temperature the higher the peak temperature of stable operation. Because of the sheath embrittlement the heat treatment temperature had to be lowered to 1450°C resulting in a stable operating temperature of about 1250°C. One of the successes of the furnace testing program was identification of a shortcoming in the heat treatment procedure that had been traditionally used in the production of HTIR-TCs. The shortcoming was that the entire heated length of the HTIR-TC sensor was not being heat treated, but rather only the part of the sensor expected to experience temperatures above 1000°C. The problem manifested itself when the thermocouples were removed from the heat treat furnace and placed in another furnace with a different geometry, their indicated temperatures would be widely scattered, but mostly in the negative direction. The solution was to heat treat the entire heated length of the sensor. Since the deepest immersion depth in the AGR-5/6/7 experiment was about 40 inches, a heat treatment length of 48 inches was used. After this change was implemented, thermocouples which were moved into a new environment with a different temperature profile (i.e., a different furnace), produced accurate temperature measurements. Although assembly of the AGR-5/6/7 experiment was completed in September of 2017 (and irradiation begun in 2018), furnace testing of thermocouples continued in 2018 and 2019. The main purpose of this testing was to establish very long-term drift characteristics of the HTIR and Cambridge Type N thermocouples installed in the experiment. Representative thermocouples from the same lots as those installed in the AGR-5/6/7 experiment were used. Additionally, thermocouples of different designs, (particularly variations on the HTIR-TC design) were "piggy-backed" on this testing program to provide insights for instrumenting future very high temperature irradiation experiments. This two-year testing program demonstrated that HTIR-TCs and Cambridge Type N TCs could operate at 1250°C for up to 10,000 hrs (and in some cases longer) while experiencing negative drifts on the order of 2-4°C/1000 hrs. This performance was considered acceptable given the extreme operating environment the sensors faced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Distributed Temperature Profiling System for Vertically and Laterally Dense Acquisition of Soil and Snow Temperature: Supporting Data

This dataset was used to assess the potential of a Distributed Temperature Profiling System developed and presented in the article named "A Distributed Temperature Profiling System for Vertically and Laterally Dense Acquisition of Soil and Snow Temperature" and submitted to Cryosphere. There are three comma-delimited data files (.csv). Each of them contains snow or soil temperature with times (UTC) in the first column and temperature at various vertical distance from the ground surface (positive means in air/snow) or below the ground surface (negative means in soil). The measurements were acquired every 15 minutes. Data collected at the East River, Colorado site with two probes: 1) measuring air/snow temperature from 1.1 m above the ground surface to the ground surface (with 5 or 10 cm spacing between sensors) and 2) measuring soil temperature from the ground surface to 0.7 m depth (with 5 or 10 cm spacing between sensors). Data collected at the Teller road (mile 27) site near Nome, Alaska with one probe: measuring soil temperature from 5 cm above the ground surface to 1.05 m depth (with 5 or 10 cm spacing between sensors). Additional metadata included in *.csv and *.pdf files. NGEE Arctic Project Summary: The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Ground-based temperature and humidity profiling: combining active and passive remote sensors

Abstract. Thermodynamic profiles in the planetary boundary layer (PBL) are important observations for a range of atmospheric research and operational needs. These profiles can be retrieved from passively sensed spectral infrared (IR) or microwave (MW) radiance observations or can be more directly measured by active remote sensors such as water vapor differential absorption lidars (DIALs). This paper explores the synergy of combining ground-based IR, MW, and DIAL observations using an optimal-estimation retrieval framework, quantifying the reduction in the uncertainty in the retrieved profiles and the increase in information content as additional observations are added to IR-only and MW-only retrievals. This study uses ground-based observations collected during the Perdigão field campaign in central Portugal in 2017 and during the DIAL demonstration campaign at the Atmospheric Radiation Measurement Southern Great Plains site in 2017. The results show that the information content in both temperature and water vapor is higher for the IR instrument relative to the MW instrument (thereby resulting in smaller uncertainties) and that the combined IR + MW retrieval is very similar to the IR-only retrieval below 1.5 km. However, including the partial profile of water vapor observed by the DIAL increases the information content in the combined IR + DIAL and MW + DIAL water vapor retrievals substantially, with the exact impact vertically depending on the characteristics of the DIAL instrument itself. Furthermore, there is a slight increase in the information content in the retrieved temperature profile using the IR + DIAL relative to the IR-only; this was not observed in the MW + DIAL retrieval.

54 ENVIRONMENTAL SCIENCES↗

Non-invasive, in situ diagnosis and monitoring of corrosion in high temperature systems

Techniques for non-invasive diagnosis and/or monitoring of corrosion in high temperature systems using specialized sensors that produce multi-mode acoustic signals in situ for accurate determination of wall loss and/or physical property changes for a vessel in contact with a high temperature, highly corrosive substance are disclosed. Sensitivity of a few microns (or about 0.1%) of wall loss, detection of changes in physical properties of vessel contents (e.g., approximately 1%), or both, at temperatures of 500° C., 600° C., or higher may be realized. Corrosion may be identified and/or monitored using time domain, frequency domain, or mixed time domain and frequency domain analysis of signal characteristics, signal delay, or both, for relatively short circumferential acoustic wave propagation (e.g., a few inches), as well as relatively long axial acoustic wave propagation (e.g., tens of feet).

Findikoglu, Alp Tugrul↗