Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “teeth”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

The Dual-Rasp Sampling System for an Enceladus Lander

The Dual-Rasp sampling system has been developed for the unique sampling environment of a lander mission to the surface of Saturn’s moon Enceladus. Plume material from the subsurface ocean that has fallen to the surface is desired resulting in an objective to sample the topmost layer of icy material. The low gravity and potential large range of surface properties are challenges for the sampling system. The Dual-Rasp sampling system has two counter-rotating rasp cutters with teeth that remove material that is thrown up between the cutters. Two prototypes of the Dual-Rasp sampling system were built and tested, one with a carousel and one that uses pneumatics for sample transfer.

Ubellacker, Samuel↗

Classifying Agnostic Biosignatures using Raman, VNIR, and Elemental Data

How can we use our current wealth of terrestrial data, encompassing biogenic and abiogenic systems, to determine the distinguishing properties of life? SCOBI (Statistical Classification of Biosignature Information) uses machine learning techniques to algorithmically identify combinations of measurements that are “indicative of life”. A set of ~1000 observations, comprising elemental abundance, isotopic fractionation, VNIR reflectance, and (in progress) Raman spectra, have been assembled from existing literature and databases. The observations cover systems classified as “indicative alive” (e.g., cells, vegetation), “indicative non-alive” (e.g., fossils, teeth), “mixed indicative” (e.g., soil, pond water), or “non-indicative” (e.g., rocks, meteorites). VNIR data was preprocessed by linear interpolation from 400-2100 nm and smoothed with a Savitzky-Golay filter. To limit the amount of Earth-biochemistry-specific (non-agnostic) information included, the first five spectral features extracted were number of peaks, number of troughs, mean reflectance, mean peak width, and broadest peak width. To help further emphasize agnostic biosignatures, Earth-specific features such as chlorophylls have been manually flagged so that feature importance with and without them can be compared. Classifiers including k-nearest neighbors (KNN), Gaussian Naïve Bayes (GNB), logistic regression (LR), random forest (RF), and support vector machine (SVM) were implemented, as was a combination voting classifier. Performance metrics included false positive rates, false negative rates, and AUC with 50-50 test/train splits (Monte Carlo simulations). Key takeaways from this stage, prior to the inclusion of Raman spectra, are (1) the overall success rate of 0.933 AUC was most heavily influenced by the elemental abundance data; and (2) VNIR reflectance had the lowest classification performance with 0.52 AUC (58% of objects correctly classified). The next steps are to complete integration of Raman spectral data and to improve the approach to pre-processing and feature extraction for both types of spectral data, such as automated baseline removal, whole spectrum matching, and dimensionality reduction.

Biosignatures↗

The Dual-Rasp Sampling System for an Enceladus Lander

The Dual-Rasp sampling system has been developed for the unique sampling environment of a lander mission to the surface of Saturn’s moon Enceladus. Plume material from the subsurface ocean that has fallen to the surface is desired resulting in an objective to sample the topmost layer of icy material. The low gravity and potential large range of surface properties are challenges for the sampling system. The Dual-Rasp sampling system has two counter-rotating rasp cutters with teeth that remove material that is thrown up between the cutters. Two prototypes of the Dual-Rasp sampling system were built and tested, one with a carousel and one that uses pneumatics for sample transfer.

Backes, Paul↗

A Novel Ultrasonic Fully Reversible Bending Fatigue Test Specimen for Simulated Gear Tooth Bending Fatigue

Gears in vertical lift applications will typically experience greater than 107bending fatigue cycles over their design lifetime. Currently, fatigue life prediction of gears exceeding 107cycles are based on empirical correlations, since collection of fatigue data beyond 107 cycles is impractical with traditional fatigue testing methods. Ultrasonic fatigue testing enables fatigue testing in excess of 109cycles in as few as 14 hours. In this paper, a novel specimen design for ultrasonic fatigue testing to accurately represent the geometry, stress profile, and residual stress of gear teeth in reversible bending fatigue is presented. The specimen design is discussed in detail, testing is performed to validate operating principles, and an initial fatigue data set of 8 specimens is presented.

Single Tooth Bending Fatigue↗

A Novel Ultrasonic Fully Reversible Bending Fatigue Test Specimen for Simulated Gear Tooth Bending Fatigue

Gears in vertical lift applications will typically experience greater than 107bending fatigue cycles over their design lifetime. Currently, fatigue life prediction of gears exceeding 107cycles are based on empirical correlations, since collection of fatigue data beyond 107 cycles is impractical with traditional fatigue testing methods. Ultrasonic fatigue testing enables fatigue testing in excess of 109cycles in as few as 14 hours. In this paper, a novel specimen design for ultrasonic fatigue testing to accurately represent the geometry, stress profile, and residual stress of gear teeth in reversible bending fatigue is presented. The specimen design is discussed in detail, testing is performed to validate operating principles, and an initial fatigue data set of 8 specimens is presented.

Single Tooth Bending Fatigue↗

Enhancing Future Commercial Space Stations: Applying ISS Insights to Environmental Control and Life Support Systems (ECLSS) Development

The expansion of space exploration to commercial space stations represents a shift from government-led endeavors to a new competitive era driven by private companies and innovative forces. The journey to actualize these celestial outposts is fraught with difficulties, including the intricate establishment of Environmental Control and Life Support systems (ECLSS) within these commercial space stations. By applying the insights gleaned from the ISS, particularly during the initial conceptual design phase of the commercial developments, there is an opportunity to circumvent some of the teething issues and optimize the development process. Furthermore, applying insights from the ISS ECLSS design, development, test, and maintenance phases has the potential to enhance system compatibility and mitigate the challenges associated with upgrading a fixed design. This approach can lead to lower costs due to fewer iterations and streamlined processes. This paper will conduct an in-depth evaluation of the ECLS system from both system and operational perspectives with the aim to provide a knowledge capture for early-stage design considerations to bolster the development of sustainable, efficient, and habitable commercial space stations.

ISS↗

Enhancing Future Commercial Space Stations: Applying ISS Insights to Environmental Control and Life Support Systems (ECLSS) Development

The expansion of space exploration to commercial space stations represents a shift from government-led endeavors to a new competitive era driven by private companies and innovative forces. The journey to actualize these celestial outposts is fraught with difficulties, including the intricate establishment of Environmental Control and Life Support systems (ECLSS) within these commercial space stations. By applying the insights gleaned from the ISS, particularly during the initial conceptual design phase of the commercial developments, there is an opportunity to circumvent some of the teething issues and optimize the development process. Furthermore, applying insights from the ISS ECLSS design, development, test, and maintenance phases has the potential to enhance system compatibility and mitigate the challenges associated with upgrading a fixed design. This approach can lead to lower costs due to fewer iterations and streamlined processes. This paper will conduct an in-depth evaluation of the ECLS system from both system and operational perspectives with the aim to provide a knowledge capture for early-stage design considerations to bolster the development of sustainable, efficient, and habitable commercial space stations.

ISS↗

Assessing the Added Value of Miniature X-Ray in the Setting of Portable Ultrasound in Spaceflight

INTRODUCTION: Point-of-care ultrasound (POCUS) has become the standard of care for imaging diagnosis and management in low-Earth Orbit (LEO) spaceflight and it has long been hypothesized that POCUS will also be the standard of care for exploration spaceflight. However, like the trajectory for which ultrasound became more portable and user-friendly, the mass, volume, and power requirements of radiography devices for both diagnostic and therapeutic applications have also been dramatically reduced. This study seeks to determine the clinical utility and added value of miniature x-ray (XR) for the diagnosis and management of each of the 119 conditions within NASA Exploration Medical Capability’s IMPACT Condition List (ICL) given that the medical system is presumed to already be carrying a handheld portable POCUS device. METHODS: For each condition, a team of reviewers performed a rapid systematic literature review seeking sensitivity and specificity data for both handheld portable ultrasound and miniature XR. When there was a paucity of data, subject matter expertise and clinical experience was added to semi-quantitatively score the added value of miniature XR, given an US was already available for both diagnosis and management. Diagnostic utility of a modality for a condition was evaluated in the setting of both the best- and worst-case scenario definitions included and defined by the ICL. Evidence tracing and quality of evidence scores were also recorded. RESULTS/DISCUSSION: Conditions for which it was determined that miniature XR added diagnostic or therapeutic value are provided in this presentation. Previously presented work by our team has demonstrated that XR provides diagnostic and management capabilities that are hypothesized to complement or surpass ultrasound for over one-third of medical conditions that may arise during exploration spaceflight (i.e., diagnosis of injuries to the axial skeleton, teeth, and lungs as well as management of orthopedic reductions, endotracheal tube placement, and drain placement confirmation). In the setting of known inclusion of a handheld portable POCUS device, there remains significant added value of portable miniature XR. Whether or not this added clinical benefit is worth the mass, volume, and power requirements of the radiography system remains yet unknown and is the focus of future work. LEARNING OBJECTIVES: 1) Understand the value of ultrasound and radiography in the diagnosis and management of medical comorbidities that may arise in exploration spaceflight; 2) Understand the medical conditions of highest concern on exploration class missions for which miniature x-ray may provide added value to portable ultrasound.

J G Steller↗

Assessing the Added Value of Miniature X-Ray in the Setting of US in Spaceflight

INTRODUCTION: Point-of-care ultrasound (POCUS) has become the standard of care for imaging diagnosis and management in lowEarth Orbit (LEO) spaceflight and it has long been hypothesized that POCUS will also be the standard of care for exploration spaceflight. However, like the trajectory for which ultrasound became more portable and user-friendly, the mass, volume, and power requirements of radiography devices for both diagnostic and therapeutic applications have also been dramatically reduced. This study seeks to determine the clinical utility and added value of miniature x-ray (XR) for the diagnosis and management of each of the 119 conditions within NASA Exploration Medical Capability’s IMPACT Condition List (ICL) given that the medical system is presumed to already be carrying a handheld portable POCUS device. METHODS: For each condition, a team of reviewers performed a rapid systematic literature review seeking sensitivity and specificity data for both handheld portable ultrasound and miniature XR. When there was a paucity of data, subject matter expertise and clinical experience was added to semi-quantitatively score the added value of miniature XR, given an US was already available for both diagnosis and management. Diagnostic utility of a modality for a condition was evaluated in the setting of both the best- and worst-case scenario definitions included and defined by the ICL. Evidence tracing and quality of evidence scores were also recorded. RESULTS/DISCUSSION: Conditions for which it was determined that miniature XR added diagnostic or therapeutic value are provided in this presentation. Previously presented work by our team has demonstrated that XR provides diagnostic and management capabilities that are hypothesized to complement or surpass ultrasound for over one-third of medical conditions that may arise during exploration spaceflight (i.e., diagnosis of injuries to the axial skeleton, teeth, and lungs as well as management of orthopedic reductions, endotracheal tube placement, and drain placement confirmation). In the setting of known inclusion of a handheld portable POCUS device, there remains significant added value of portable miniature XR. Whether or not this added clinical benefit is worth the mass, volume, and power requirements of the radiography system remains yet unknown and is the focus of future work. LEARNING OBJECTIVES: 1) Understand the value of ultrasound and radiography in the diagnosis and management of medical comorbidities that may arise in exploration spaceflight; 2) Understand the medical conditions of highest concern on exploration class missions for which miniature x-ray may provide added value to portable ultrasound.

Jon Steller↗

C-105 heel pit removed and C-105 dome cut paves way for new retrieval technology

For just the second time, crews have cut a hole in the top of an active radioactive waste storage tank at Hanford. Workers began cutting a 55-inch hole in the top of Tank C-105 last Tuesday night on graveyard shift, completing the cut early Wednesday. The hole will allow for installation of the Mobile Arm Retrieval System (MARS) Vacuum into the tank. The cut was made through 17 inches of concrete and rebar using the newly developed rotary-core cutting system, which uses a laser-guided steel canister with teeth on the bottom to drill a round hole into the tank dome. The project was completed safely and successfully in a high-rad area without contamination or significant dose to workers.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental Characterization of a Grid-Loss Event on a 2.5-MW Dynamometer Using Advanced Operational Modal Analysis: Preprint

This paper experimentally investigates a worst case grid loss event conducted on the National Renewable Energy Laboratory (NREL) Gearbox Reliability Collaborative (GRC) drivetrain mounted on the 2.5MW NREL dynamic nacelle test-rig. The GRC drivetrain has a directly grid-coupled, fixed speed asynchronous generator. The main goal is the assessment of the dynamic content driving this particular assess the dynamic content of the high-speed stage of the GRC gearbox. In addition to external accelerometers, high frequency sampled measurements of strain gauges were used to assess torque fluctuations and bending moments both at the nacelle main shaft and gearbox high-speed shaft (HSS) through the entire duration of the event. Modal analysis was conducted using a polyreference Least Squares Complex Frequency-domain (pLSCF) modal identification estimator. The event driving the torsional resonance was identified. Moreover, the pLSCF estimator identified main drivetrain resonances based on a combination of acceleration and strain measurements. Without external action during the grid-loss event, a mode shape characterized by counter phase rotation of the rotor and generator rotor determined by the drivetrain flexibility and rotor inertias was the main driver of the event. This behavior resulted in significant torque oscillations with large amplitude negative torque periods. Based on tooth strain measurements of the HSS pinion, this work showed that at each zero-crossing, the teeth lost contact and came into contact with the backside flank. In addition, dynamic nontorque loads between the gearbox and generator at the HSS played an important role, as indicated by strain gauge-measurements.

17 WIND ENERGY↗

Pressure actuated film riding seals for turbo machinery

A seal assembly for a rotary machine is provided. The seal assembly includes multiple sealing device segments disposed circumferentially intermediate to a stationary housing and a rotor. Each of the sealing device segments includes a stator interface element, a shoe plate having an extended portion having one or more labyrinth teeth facing the rotor and a load bearing portion, wherein the shoe plate is configured to generate an aerodynamic force between the shoe plate and the rotor. The sealing device segment further includes a secondary seal configured to be in contact with the stator interface element at a radially outer end and configured to be in contact with an elevated nose section of the extended portion of the shoe plate on a radially inner end; and multiple flexible elements attached to the shoe plate and to the stator interface element.

42 ENGINEERING↗

Aerodynamic seals for rotary machine

An aerodynamic seal assembly for a rotary machine includes multiple sealing device segments disposed circumferentially intermediate to a stationary housing and a rotor. Each of the segments includes a shoe plate with a forward-shoe section and an aft-shoe section having multiple labyrinth teeth therebetween facing the rotor. The sealing device segment also includes multiple flexures connected to the shoe plate and to a top interface element, wherein the multiple flexures are configured to allow the high pressure fluid to occupy a forward cavity and the low pressure fluid to occupy an aft cavity. Further, the sealing device segments include a secondary seal attached to the top interface element at one first end and positioned about the flexures and the shoe plate at one second end.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Film riding seal assembly for turbomachinery

An aerodynamic seal assembly for a rotary machine includes multiple sealing segments disposed circumferentially intermediate to a stationary housing and a rotor. Each of the segments includes a shoe plate with a forward load-bearing section and an aft load-bearing section configured to generate an aerodynamic force between the shoe plate and the rotor. The shoe plate includes at least one labyrinth teeth facing the rotor and positioned between the forward load-bearing section and the aft load-bearing section. The sealing segment also includes at least one spring connected to a pedestal located about midway of an axial length of the shoe plate and to a stator interface element. Further, the sealing segment includes a rigid segmented secondary seal attached to the stator interface element at one first end and in contact with the pedestal of the shoe plate at one second end.

33 ADVANCED PROPULSION SYSTEMS↗

Film riding seals for rotary machines

A seal assembly for a rotary machine is provided. The seal assembly includes multiple sealing device segments disposed circumferentially intermediate to a stationary housing and a rotor. Each of the segments includes a shoe plate with a forward-shoe section and an aft-shoe section having one or more labyrinth teeth therebetween facing the rotor. The sealing device includes a stator interface element having a groove or slot for allowing disposal of a spline seal for preventing segment leakages. The sealing device segment also includes multiple bellow springs or flexures connected to the shoe plate and to the stator interface element. Further, the sealing device segments include a secondary seal integrated with the stator interface element at one end and positioned about the multiple bellow springs or flexures and the shoe plate at the other end.

42 ENGINEERING↗

Torque ripple reduction in electric machines

An electric machine, such as an Internal Permanent magnet or Synchronous Reluctance machine, having X phases, that includes a stator assembly, having M slots, with a stator core and stator teeth, that is further configured with stator windings to generate a stator magnetic field when excited with alternating currents and extends along a longitudinal axis with an inner surface that defines a cavity; and a rotor assembly, having N poles, disposed within the cavity which is configured to rotate about the longitudinal axis, wherein the rotor assembly includes a shaft, a rotor core located circumferentially around the shaft. The machine is configured such that a value k=M/(X*N) wherein k is a non-integer greater than about 1.3. The electric machine may alternatively, or additionally, include a non-uniformed gap between the exterior surface of the rotor spokes and the interior stator surface of the stator.

42 ENGINEERING↗

Electric machine

A permanent magnet machine includes a stator having a stator core, a plurality of stator teeth and plurality of stator windings coupled to the stator core. The stator is configured to generate a stator magnetic rotating field when the stator windings are excited with an electric current. The stator magnetic rotating field includes both synchronous sub-harmonic and super-harmonic components. The permanent magnet machine also includes a rotor that is disposed within the stator. The rotor includes a rotor core and a plurality of rotor magnets that are coupled to the rotor core. The rotor magnets are further configured to have a predefined orientation profile such that when the stator windings are excited with an electric current, sub-harmonic and super-harmonic magnetic rotating fields are generated in the rotor magnetic field. The stator sub-harmonic and super-harmonic magnetic rotating fields interact with the rotor sub-harmonic and super-harmonic magnetic rotating fields and produce an aiding torque on in the permanent magnet machine.

42 ENGINEERING↗

Slot waveguide with structural modulation

Apparatuses for communication or sensing are disclosed, the apparatuses comprising a substrate; a bottom cladding disposed on the substrate; a device layer disposed on the bottom cladding, wherein the device layer comprises: two substantially parallel rails extending from an input side to an output side of the device layer and configured to form a slot between the two substantially parallel rails, wherein each of the two substantially parallel rails comprises an inner edge adjacent to the slot and an outer edge opposite the slot; and one or more teeth coupled to each of the two substantially parallel rails; and a top cladding disposed onto the device layer and bottom cladding; wherein the bottom cladding, the device layer, and the top cladding are configured to support at least one optical guided mode. Other embodiments are described and claimed.

47 OTHER INSTRUMENTATION↗