Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “target”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Hypoxia-Independent Downregulation of Hypoxia-Inducible Factor 1 Targets by Androgen Deprivation Therapy in Prostate Cancer

Purpose: We explored changes in hypoxia-inducible factor 1 (HIF1) signaling during androgen deprivation therapy (ADT) of androgen-sensitive prostate cancer xenografts under conditions in which no significant change in immunostaining of the hypoxia marker pimonidazole had occurred. Methods and Materials: Gene expression profiles of volume-matched androgen-exposed and androgen-deprived CWR22 xenografts, with similar pimonidazole-positive fractions, were compared. Direct targets of androgen receptor (AR) and HIF1 transcription factors were identified among the differentially expressed genes by using published lists. Biological processes affected by ADT were determined by gene ontology analysis. HIF1α protein expression in xenografts and biopsy samples from 35 patients receiving neoadjuvant ADT was assessed by immunohistochemistry. Results: A total of 1344 genes showed more than 2-fold change in expression by ADT, including 35 downregulated and 5 upregulated HIF1 targets. Six genes were shared HIF1 and AR targets, and their downregulation was confirmed with quantitative RT-PCR. Significant suppression of the biological processes proliferation, metabolism, and stress response in androgen-deprived xenografts was found, consistent with tumor regression. Nineteen downregulated HIF1 targets were involved in those significant biological processes, most of them in metabolism. Four of these were shared AR and HIF1 targets, including genes encoding the regulatory glycolytic proteins HK2, PFKFB3, and SLC2A1. Most of the downregulated HIF1 targets were induced by hypoxia in androgen-responsive prostate cancer cell lines, confirming their role as hypoxia-responsive HIF1 targets in prostate cancer. Downregulation of HIF1 targets was consistent with the absence of HIF1α protein in xenografts and downregulation in patients by ADT (P<.001). Conclusions: AR repression by ADT may lead to downregulation of HIF1 signaling independently of hypoxic fraction, and this may contribute to tumor regression. HIF1α expression is probably not a useful hypoxia biomarker during ADT in prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The effect of the target-organ geometric complexity on the choice of delivery between RapidArc and sliding-window IMRT for nasopharyngeal carcinoma

We attempted to assess the effect of target-organ geometric complexity on the plan quality of sliding-window intensity-modulated radiotherapy (IMRT), double-arc (RA2), and triple-arc (RA3) RapidArc volumetric-modulated arc radiotherapy for nasopharyngeal carcinoma (NPC). Plans for 9-field sliding-window IMRT, RA2, and RA3 were optimized for 36 patients with NPC ranging from T1 to T4 tumors. Initially the patients were divided into 2 groups, with group A representing the most simple early stage (T1 and T2) cases, whereas group B represented the more complex advanced cases (T3 and T4). Evaluation was performed based on target conformity, target dose homogeneity, organ-sparing capability, and delivery efficiency. Based on the plan quality results, a subgroup of advanced cases, group B2, representing the most demanding task was distinguished and reported separately from the rest of the group B cases, B1. Detailed analysis was performed on the anatomic features for each group of cases, so that planners can easily identify the differences between B1 and B2. For the group A cases, RA3 plans were superior to the IMRT plans in terms of organ sparing, whereas target conformity and dose homogeneity were similar. For the group B1 cases, the RA3 plans produced almost equivalent plan quality as the IMRT plans. For the group B2 cases, for most of which large target volumes were adjacent to (5 mm or less) and wrapping around the brain stem, RA2 and RA3 were inferior to the IMRT regarding both target dose homogeneity and conformity. RA2 plans were slightly inferior to IMRT and RA3 plans for most cases. The plan comparison results depend on the target to brain stem distances and the target sizes. The plan quality results together with the anatomic information may allow the evaluation of the 3 treatment options before actual planning.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison of pencil beam–based homogeneous vs inhomogeneous target dose planning for stereotactic body radiotherapy of peripheral lung tumors through Monte Carlo–based recalculation

This study was conducted to ascertain whether homogeneous target dose planning is suitable for stereotactic body radiotherapy (SBRT) of peripheral lung cancer under appropriate breath-holding. For 20 peripheral lung tumors, paired dynamic conformal arc plans were generated by only adjusting the leaf margin to the planning target volume (PTV) edge for fulfilling the conditions such that the prescription isodose surface (IDS) encompassing exactly 95% of the PTV (PTV D{sub 95}) corresponds to 95% and 80% IDS, normalized to 100% at the PTV isocenter under a pencil beam (PB) algorithm with radiologic path length correction. These plans were recalculated using the x-ray voxel Monte Carlo (XVMC) algorithm under otherwise identical conditions, and then compared. Lesions abutting the parietal pleura or not were defined as edge or island tumors, respectively, and the influences of the target volume and its location relative to the chest wall on the target dose were examined. The median (range) leaf margin required for the 95% and 80% plans was 3.9 mm (1.3 to 5.0) and −1.2 mm (−1.8 to 0.1), respectively. Notably, the latter was significantly correlated negatively with PTV. In the 80% plans, the PTV D{sub 95} was slightly higher under XVMC, whereas the PTV D{sub 98} was significantly lower, irrespective of the dose calculation algorithm used. Other PTV and all gross tumor volume doses were significantly higher, while the lung doses outside the PTV were slightly lower. The target doses increased as a function of PTV and were significantly lower for island tumors than for edge tumors. In conclusion, inhomogeneous target dose planning using smaller leaf margin for a larger tumor volume was deemed suitable in ensuring more sufficient target dose while slightly reducing lung dose. In addition, more inhomogeneous target dose planning using <80% IDS (e.g., 70%) for PTV covering would be preferable for island tumors.

61 RADIATION PROTECTION AND DOSIMETRY↗

Combustion-assisted ink-jet printing of nuclear targets

Advances in target fabrication are critical to high-precision measurements in nuclear physics. This work details the preparation of patterned CeO 2 and ThO 2 architectures and thin-film targets via ink-jet deposition of combustible solutions. The produced targets were characterized by scanning electron microscopy (SEM), and by alpha-particle spectroscopy for radioactive targets to determine densities. Ink jet printing of the targets, used both ethanol and 2-methoxyethanol as solvents, with cerium or thorium nitrate as the oxidizer and acetylacetone as the fuel. Additionally, we found that the distance between each droplet dispersion (step size) played the most significant role in determining the final pattern uniformity and thickness. A 50 μm step size leads to relatively thick targets with a density of 350 μg/cm 2 . Significant overlap in droplet sizes leads to a heterogeneous target with an undesirable cracked surface structure. In contrast, 150 μm spacing yields thinner (20 μg/cm 2 ) patterned structures with excellent surface coverage. This method of Ink-jet printing provides a straightforward, scalable, and high-efficiency pathway to prepare custom made, high-quality targets for nuclear physics experiments.

CeO2↗

Assessment of simulated and observed cavitation-induced erosion damage in Spallation Neutron Source target vessels

Cavitation-induced erosion damage in different Spallation Neutron Source (SNS) target designs are simulated using explicit finite element–based techniques and compared with observations of erosion in targets after operation. The efficacy of the previously developed method, called saturation time, was evaluated using erosion-damaged samples from new target designs. A new metric called maximum bubble size was implemented under the rationale that larger cavitation bubbles will collapse more intensely. The maximum cavitation bubble size over 1 ms of simulated time was calculated based on the Rayleigh–Plesset equation for each element integration point and presented as a contour map at the vessel surface for assessing with erosion observations. SNS targets are now operated with helium gas injection to reduce cavitation damage. A simulation method using a material model for the mixture of mercury and gas bubbles was recently developed and used to account for the effect of small gas bubbles on the structural response of the target vessel. Furthermore, this work compares the new method's results with observed cavitation damage. Maps of the calculated maximum bubble size for targets operated with and without gas injection were compared with photographs of erosion damage observed in SNS targets. The patterns in maximum bubble size maps correlated well with observations of erosion patterns in target vessels after service. Advantages and challenges of the maximum bubble size simulation technique are provided, and differences between results from the previous and the newly proposed metric are discussed.

Jiang, Hao↗

Systems biology approach to study the role of miRNA in promoter targeting during megakaryopoiesis

Highlights: • miRNAs could regulate Cyclins and CDKs by targeting their promoters. • Perl programming was used to identify putative targets of miRNA in promoters. • miR-1273g-3p and miR-619-5p showed significance with longest seed sequence matches. • Through CDK10, CDK11 and Cyclin, these two miRNAs could regulate cell cycle during megakaryopoiesis. The distinct process of megakaryopoiesis requires occurrence of endomitosis for polyploidization of the megakaryocytes. Although, Cyclins, CDKs and have been described to regulate endomitosis, the exact mechanism still remains an enigma. miRNA which were otherwise known as post transcriptional gene silencers are now emerging with various non-canonical functions including gene regulation at pre-transcriptional level by miRNA binding at promoter region. Out of the many processes they regulate, miRNA have been manifested to play a role in megakaryocyte differentiation. In this study an attempt has been made to identify miRNA that could regulate cell cycle genes (Cyclins and CDKs) by targeting their promoters, during megakaryopoiesis. A new computational algorithm was implemented using Perl programming to identify putative targets of miRNA in CDK and Cyclin promoters. Perl script was also used to check nuclear localizing miRNA based on the presence of a consensus sequence. Real-time PCR was performed to analyze the expression of miRNA and their predicted targets in Dami vs. PMA treated Dami cells. Putative targets of miRNAs with longest, high complementarity matches in CDK/Cyclin promoters were obtained. We identified two significant miRNA, miR-1273g-3p and miR-619-5p with longest seed sequence matches. We further identified three main targets (CDK10, CDK11, Cyclin F) through which these two miRNA could regulate cell cycle during megakaryopoiesis. Our results reinforce the role of promoting targeting miRNA in regulation of cell cycle through certain CDK/Cyclins to support the process of endomitosis during megakaryopoiesis.

60 APPLIED LIFE SCIENCES↗

Scaling Trivalent Actinide and Lanthanide Recovery by Diglycolamide Resin from Savannah River Site’s Mark-18A Targets

The Savannah River National Laboratory is implementing a separation flowsheet to recover rare isotopes and transplutonium elements from irradiated 242 Pu targets known as Mark-18A targets. The Mark-18A targets contain the United States’ supply of nonseparated 244 Pu, which has a wide range of applications from nuclear forensics to production of superheavy elements such as flerovium. The targets also contain hundreds of grams of heavy curium ( 246–248 Cm), which is used as a target material for 252 Cf production. This work investigates the use of diglycolomide resin (DGA Resin) to recover valuable trivalent actinides from the Mark-18A targets. Batch contact experiments were performed on a representative simulant to determine mass loadings. Furthermore, the resin showed an overall capacity of 11 mg/mL for a mixed metal matrix (Zr and La–Gd). Column experiments showed chromatographic separation with transition-metal breakthroughs occurring first followed by the lanthanide series La–Gd. The experiments showed that lanthanide breakthrough occurred after 11 mg/mL mass loading was reached on the column with the mixed metal matrix. A radiological column experiment with an in-line UV/vis cell was able to detect Nd breakthrough just prior to 241 Am breakthrough. Implementing an in-line UV/vis cell into full-scale Mark-18A target processing will be used to limit breakthrough of trivalent actinides recovered from the targets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved 140 Nd Production for the 140 Nd/ 140 Pr In Vivo Generator through Target Recycling and Radiochemical Optimization

Theranostic strategies that utilize f-block therapeutic radionuclides, including 161 Tb, 177 Lu, 225 Ac, and 227 Th, suffer from a shortage of positron emission tomography (PET) imaging counterparts in the same chemical space and often rely on 68 Ga as a surrogate. The 140 Nd/ 140 Pr in vivo PET generator, which belongs to the f-block, may address this issue and can be produced via the 141 Pr(p,2n) 140 Nd production route by using medium-energy cyclotrons. However, impurities in the target material, including stable Nd, and the inherent difficulty of adjacent lanthanide separations limit the achievable radionuclidic and chemical purity of 140 Nd. In this work, we address these challenges through the purification and recycling of praseodymium target material and optimization of Nd/Pr separation. The resulting purified 140Nd was evaluated using DOTA and Macropa chelators via radiolabeling and in vitro stability studies. A target material purification and recycling method was developed for the monoisotopic 141 Pr starting material to remove stable Nd impurities, yielding 90.3 ± 4.7% (n = 3) recovery. The purified 141 Pr was isolated as Pr 6 O 11 and irradiated with 24 MeV protons (20.07 MeV at the target surface) at 20 μA for 4 h, which produced 1417.0 ± 83.4 MBq (38.3 ± 2.2 mCi) of 140 Nd at the end of bombardment (EOB). The produced 140 Nd was purified through an optimized DGA normal method to recover 71.6 ± 6.3% pure 140 Nd. The amount of stable Nd reduced progressively in each target purification cycle from >340 ppm without purification to <250 ppb after three cycles, while other measured metallic impurities were below 30 ppb. This improvement in target purity was reflected in the direct increase of apparent molar activity (AMA), when purified 140 Nd was evaluated with DOTA and Macropa chelators. AMA of [ 140 Nd]Nd-DOTA and [ 140 Nd]Nd-Macropa increased from 70.3 MBq/μmol (1.9 mCi/μmol) and 74 MBq/μmol (2.0 mCi/μmol) to 8025.3 MBq/μmol (216.9 mCi/μmol) and 8473.0 MBq/μmol (229.0 mCi/μmol), respectively, after the third target purification cycle. Further evaluation of chelator-labeled 140 Nd showed that [ 140 Nd]Nd-DOTA was stable in phosphate-buffered saline (PBS), saline, human serum, and mouse serum, whereas [140Nd]Nd-Macropa was stable in all except human serum. This work established a practical methodological advance for the production of 140 Nd/ 140 Pr in vivo PET generators, combining optimized target recycling and radiochemical separation to enable scaled-up and high-molar activity 140 Nd suitable for preclinical imaging. These advances support broader development of 140 Nd/ 140 Pr as a robust PET analogue, especially for f-block therapeutics.

Irradiation↗

Multiplexed in-gel microfluidic immunoassays: characterizing protein target loss during reprobing of benzophenone-modified hydrogels

From whole tissues to single-cell lysate, heterogeneous immunoassays are widely utilized for analysis of protein targets in complex biospecimens. Recently, benzophenone-functionalized hydrogel scaffolds have been used to immobilize target protein for immunoassay detection with fluorescent antibody probes. In benzophenone-functionalized hydrogels, multiplex target detection occurs via serial rounds of chemical stripping (incubation with sodium-dodecyl-sulfate (SDS) and β-mercaptoethanol at 50-60 °C for ≥1 h), followed by reprobing (interrogation with additional antibody probes). Although benzophenone facilitates covalent immobilization of proteins to the hydrogel, we observe 50% immunoassay signal loss of immobilized protein targets during stripping rounds. Here, we identify and characterize signal loss mechanisms during stripping and reprobing. We posit that loss of immobilized target is responsible for ≥50% of immunoassay signal loss, and that target loss is attributable to disruption of protein immobilization by denaturing detergents (SDS) and incubation at elevated temperatures. Furthermore, our study suggests that protein losses under non-denaturing conditions are more sensitive to protein structure (i.e., hydrodynamic radius), than to molecular mass (size). We formulate design guidance for multiplexed in-gel immunoassays, including that low-abundance proteins be immunoprobed first, even when targets are covalently immobilized to the gel. We also recommend careful scrutiny of the order of proteins targets detected via multiple immunoprobing cycles, based on the protein immobilization buffer composition.

59 BASIC BIOLOGICAL SCIENCES↗

Cluster perturbation theory. II. Excitation energies for a coupled cluster target state

In cluster perturbation (CP) theory, we consider a target excitation space relative to a Hartree-Fock state and partition the target excitation space into a parent excitation space and an auxiliary excitation space. The zeroth-order state is in CP theory a coupled cluster (CC) state in the parent excitation space, and the target state is a CC state in the target excitation space. In this paper, we derive CP series for excitation energies in orders of the CC parent-state similarity-transformed fluctuation potential where the zeroth-order term in the series is an excitation energy for the CC parent state response eigenvalue equation and where the series formally converge to an excitation energy for the CC target state response eigenvalue equation. We give explicit expressions for the lowest-order excitation energy corrections. We also report calculations for CP excitation energy series for various parent and target excitation spaces and examine how well the lower-order corrections can reproduce the total excitation energies. Considering the fast local convergence we have observed for the CP excitation energy series, it becomes computationally attractive to use low-order corrections in CP series to obtain excitation energies of CC target state quality. For the CPS(D-n) series, the first-order correction vanishes, the second-order correction becomes the CIS(D) model, and for the CPS(D-3) model, our calculations suggest that excitation energies of CCSD quality are obtained. The numerical results also suggest that a similar behavior can be seen for the low-order excitation energy corrections for CP series where the parent state contains more than a singles excitation space, e.g., for the CPSD(T) model. Finally, we therefore expect the low-order excitation energy corrections in CP series soon to become state-of-the-art models for determining excitation energies of CC target state quality.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Isotopic targets with graphene backing

Many of the isotopes cannot be made as free-standing targets and require thin film backing. Low-Z backing materials, such as amorphous carbon and thin polymer films are materials of choice for some experiments. However, the limitations of these backing materials are poor thermal and mechanical stability. All-carbon graphene films would be an excellent choice as a backing material due to their high thermal conductivity, high temperature tolerance (3550ºC melting point), low outgassing, mechanical integrity, and ease of handling. We fabricated a variety of targets using graphene material as a backing or a host matrix. Using PVD sputtering deposition of boron-11 carbide, we fabricated 11 B target with a 0.5 mg/cm 2 on graphene film. The 11 B isotope is of interest due to aneutronic proton–boron fusion reaction 1 p + 11 B → 3 4 He + 8.7 MeV suitable for clean energy production1. We also prepared a neutron rich natCr target on graphene backing by electroplating Cr in an aqueous chromium (III) oxide bath. The chromium target can be used for production of positron emitting Mn radioisotope2 in the reaction 52 Cr (p,n) 52 Mn. One of the unique advantages of the graphene film fabrication process is the capability to embed target materials, including refractory metals, in the nanoparticle form into a host graphene matrix during target preparation. Finally, we fabricated nat Ir, nat Re, nat WO3, and nat HfO 2 nanoparticle-loaded graphene targets that can be used in nuclear physics research.

36 MATERIALS SCIENCE↗

Plasma expansion and relativistic filamentation in intense laser-irradiated cone targets

We report that compound parabolic concentrator (CPC) cone targets have been shown to produce increased MeV photons on the NIF-ARC by 10× over flat targets. Multiple x-ray frames can potentially be generated by firing the NIF-ARC's beamlets into distinct cone targets at few nanosecond relative delays. This requires that the cone targets with delayed beams are not degraded by their proximity to previous targets. One concern is that the spatial wings of a beam fired into one target can fall on neighboring targets, producing a preformed plasma that may interfere with laser light reaching the tip of the cone. In this work, 3D hydra simulations of realistic targets and beam parameters show that hundreds of micrometer scale length preplasmas are produced in cones within 1 mm of the laser spot. 2D particle-in-cell simulations of the intense main pulse in this preplasma indicate a density threshold for the onset of relativistic filamentation in our conditions. Applying our modeling approach to a NIF-ARC shot with an intentional 15 J prepulse yields good agreement with experimental results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Targeted polyelectrolyte complex micelles treat vascular complications in vivo

Vascular disease is a leading cause of morbidity and mortality in the United States and globally. Pathological vascular remodeling, such as atherosclerosis and stenosis, largely develop at arterial sites of curvature, branching, and bifurcation, where disturbed blood flow activates vascular endothelium. Current pharmacological treatments of vascular complications principally target systemic risk factors. Improvements are needed. We previously devised a targeted polyelectrolyte complex micelle to deliver therapeutic nucleotides to inflamed endothelium in vitro by displaying the peptide VHPKQHR targeting vascular cell adhesion molecule 1 (VCAM-1) on the periphery of the micelle. This paper explores whether this targeted nanomedicine strategy effectively treats vascular complications in vivo. Disturbed flow-induced microRNA-92a (miR-92a) has been linked to endothelial dysfunction. We have engineered a transgenic line (miR-92a EC-TG /Apoe –/– ) establishing that selective miR-92a overexpression in adult vascular endothelium causally promotes atherosclerosis in Apoe –/– mice. We tested the therapeutic effectiveness of the VCAM-1–targeting polyelectrolyte complex micelles to deliver miR-92a inhibitors and treat pathological vascular remodeling in vivo. VCAM-1–targeting micelles preferentially delivered miRNA inhibitors to inflamed endothelial cells in vitro and in vivo. The therapeutic effectiveness of anti–miR-92a therapy in treating atherosclerosis and stenosis in Apoe –/– mice is markedly enhanced by the VCAM-1–targeting polyelectrolyte complex micelles. These results demonstrate a proof of concept to devise polyelectrolyte complex micelle-based targeted nanomedicine approaches treating vascular complications in vivo.

60 APPLIED LIFE SCIENCES↗

Results of Ion Cyclotron Heating Experiments on Proto-MPEX Utilizing a Movable Stainless Steel Target

Ion cyclotron heating (ICH) at a frequency in the 6- to 9-MHz range with electron heating in the 28- to 105-GHz range will be used in the Material Plasma Exposure eXperiment (MPEX) to greatly increase the energy of the plasma stream produced by the helicon plasma source. ICH was chosen over substrate biasing to produce energetic ions because it can more accurately reproduce plasma-material interactions in a fusion device. For instance, when the target is tilted with respect to the background magnetic field during ICH, a magnetic presheath is created so that redeposition phenomena as in a tokamak divertor can be better approximated. ICH experiments were conducted on the Proto-MPEX device, which was developed to provide a physics basis upon which MPEX is designed. In this paper we describe some of these experiments in which the previous fixed graphite target was replaced by a movable stainless steel target. With the new target, the strong, monotonic decrease in ion temperature observed previously as a function of axial distance between the ion cyclotron resonance region and the target was not observed. Instead, only a small drop was seen within ~1 cm of the target. The ion temperatures were determined spectroscopically, utilizing Doppler broadening measurements of an Ar II line, in a plasma that is 90% deuterium and 10% argon. Measurements were obtained using optical fibers at a fixed location, with the target moving perpendicularly relative to the viewing chords. Comparisons with previous results will be discussed, including observed plasma parameters Ti, Te, and ne, and heat flux at the target.

Goulding, Richard↗

Assessment of personal airborne exposures and surface contamination from x-ray vaporization of beryllium targets at the National Ignition Facility

Here, this article presents air and surface sampling data collected over the first two years since beryllium was introduced as a target material at the National Ignition Facility. Over this time, 101 experiments with beryllium-containing targets were executed. The data provides an assessment of current conditions in the facility and a baseline for future impacts as new, reduced regulatory limits for beryllium are being proposed by both the Occupational Safety and Health Administration and Department of Energy. This study also investigates how beryllium deposits onto exposed surfaces as a result of x-ray vaporization and the effectiveness of simple decontamination measures in reducing the amount of removable beryllium from a surface. Based on 1,961 surface wipe samples collected from entrant components (equipment directly exposed to target debris) and their surrounding work areas during routine reconfiguration activities, only one result was above the beryllium release limit of 0.2 µg/100 cm 2 and 27 results were above the analytical reporting limit of 0.01 µg/100 cm 2 , for a beryllium detection rate of 1.4%. Surface wipe samples collected from the internal walls of the NIF target chamber, however, showed higher levels of beryllium, with beryllium detected on 73% and 87% of the samples during the first and second target chamber entries (performed annually), respectively, with 23% of the samples above the beryllium release limit during the second target chamber entry. The analysis of a target chamber wall panel exposed during the first 30 beryllium-containing experiments (cumulatively) indicated that 87% of the beryllium contamination remains fixed onto the surface after wet wiping the surface and 92% of the non-fixed contamination was removed by decontaminating the surface using a dry wipe followed by a wet wipe. Personal airborne exposures assessed during access to entrant components and during target chamber entry indicated that airborne beryllium was not present in workers' breathing zones. Finally, all the data thus far have shown that beryllium has been effectively managed to prevent exposures to workers during routine and non-routine work.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-480: Radiobiological Dose Comparison of Single Fraction SRS, Multi-Fraction SRT and Multi-Stage SRS of Large Target Volumes Using the Linear-Quadratic Formula

Purpose: To compare the radiobiological effect on large tumors and surrounding normal tissues from single fraction SRS, multi-fractionated SRT, and multi-staged SRS treatment. Methods: An anthropomorphic head phantom with a centrally located large volume target (18.2 cm{sup 3}) was scanned using a 16 slice large bore CT simulator. Scans were imported to the Multiplan treatment planning system where a total prescription dose of 20Gy was used for a single, three staged and three fractionated treatment. Cyber Knife treatment plans were inversely optimized for the target volume to achieve at least 95% coverage of the prescription dose. For the multistage plan, the target was segmented into three subtargets having similar volume and shape. Staged plans for individual subtargets were generated based on a planning technique where the beam MUs of the original plan on the total target volume are changed by weighting the MUs based on projected beam lengths within each subtarget. Dose matrices for each plan were export in DICOM format and used to calculate equivalent dose distributions in 2Gy fractions using an alpha beta ratio of 10 for the target and 3 for normal tissue. Results: Singe fraction SRS, multi-stage plan and multi-fractionated SRT plans had an average 2Gy dose equivalent to the target of 62.89Gy, 37.91Gy and 33.68Gy, respectively. The normal tissue within 12Gy physical dose region had an average 2Gy dose equivalent of 29.55Gy, 16.08Gy and 13.93Gy, respectively. Conclusion: The single fraction SRS plan had the largest predicted biological effect for the target and the surrounding normal tissue. The multi-stage treatment provided for a more potent biologically effect on target compared to the multi-fraction SRT treatments with less biological normal tissue than single-fraction SRS treatment.

60 APPLIED LIFE SCIENCES↗

WE-EF-BRA-07: High Performance Preclinical Irradiation Through Optimized Dual Focal Spot Dose Painting and Online Virtual Isocenter Radiation Field Targeting

Purpose: Advances in radiotherapy practice facilitated by collimation systems to shape radiation fields and image guidance to target these conformal beams have motivated proposals for more complex dose patterns to improve the therapeutic ratio. Recent progress in small animal radiotherapy platforms has provided the foundation to validate the efficacy of such interventions, but robustly delivering heterogeneous dose distributions at the scale and accuracy demanded by preclinical studies remains challenging. This work proposes a dual focal spot optimization method to paint spatially heterogeneous dose regions and an online virtual isocenter targeting method to accurately target the dose distributions. Methods: Two-dimensional dose kernels were empirically measured for the 1 mm diameter circular collimator with radiochromic film in a solid water phantom for the small and large x-ray focal spots on the X-RAD 225Cx microirradiator. These kernels were used in an optimization framework which determined a set of animal stage positions, beam-on times, and focal spot settings to optimally deliver a given desired dose distribution. An online method was developed which defined a virtual treatment isocenter based on a single image projection of the collimated radiation field. The method was demonstrated by optimization of a 6 mm circular 2 Gy target adjoining a 4 mm semicircular avoidance region. Results: The dual focal spot technique improved the optimized dose distribution with the proportion of avoidance region receiving more than 0.5 Gy reduced by 40% compared to the large focal spot technique. Targeting tests performed by irradiating ball bearing targets on radiochromic film pieced revealed the online targeting method improved the three-dimensional accuracy from 0.48 mm to 0.15 mm. Conclusion: The dual focal spot optimization and online virtual isocenter targeting framework is a robust option for delivering dose at the preclinical level and provides a new experimental option for unique radiobiological investigations This work is supported, in part, by the Natural Sciences and Engineering Research Council of Canada and a Mitacs-Accelerate fellowship. P.E. Lindsay, and D.A. Jaffray are listed as inventors of the system described herein. This system has been licensed to Precision X-Ray Inc. for commercial development.

60 APPLIED LIFE SCIENCES↗

Topics in LIFE Target Survival: 11-SI-004 Final Report

The LIFE target design incorporates many considerations to generate the desired fusion gain including the physics design, the cost of manufacturing of the target, the injectability of the target, the aerodynamic flight characteristics of the target, the ability to track and engage the target and to maintain the structural and thermal integrity of the target. This document describes the effort that was made in support of issues of survivability of the target during injection which included issues massmanufactural materials and processes which could be used in the target.

42 ENGINEERING↗