Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Comparison of Electromagnetic Transient and Phasor Dynamic Simulations: Implications for Inverter Dominated Systems

The simulation of very high shares of inverter-based resources in power systems has begun to draw into question the validity of phasor domain tools in capturing relevant dynamics. Electromagnetic transient simulators can capture the dynamics of power electronics with substantially smaller time steps, but are computationally expensive. This work contrasts the results of phasor domain and electromagnetic transient tools for simulations on a validated model of the Maui power system operating at very high inverter-based resource shares with near zero voltage forming devices. The results show that the phasor domain tool predicts optimistic stability with fewer voltage forming elements on the network, and loses computational stability before the electromagnetic transient tool. As the electromagnet transient model is of the entire system, and system-wide discrepancies are observed, this case study of a physical power system highlights the potential need for system-wide detailed modeling during periods of very high shares of inverter-based resources and few voltage forming devices.

electromagnetic transient-domain↗

Systems Engineering and Analysis in Support of a US Federal Staging Facility for UNF

The US Department of Energy Office of Nuclear Energy (DOE-NE) Office of Spent Fuel and High-Level Waste Disposition is examining a set of system options and conducting supporting analyses to inform the development of an integrated waste management system, which may include one or more federal staging facilities (FSFs) for used nuclear fuel (UNF ) sited using a collaborative siting process. This paper focuses on the ongoing activities in two systems engineering and analysis work areas: (1) data and tools development, validation, and maintenance and (2) systems engineering execution. Within the first work area, the STANDARDS 5.0 UNF data and analysis tool, formerly known as UNF-ST&DARDS, is being developed as a foundational resource to assist in the management of UNF data. It has the key capability to model UNF throughout the entire back end of the fuel cycle. STANDARDS also includes several compatible analysis tools for the time-dependent characterization of UNF and related systems by interfacing with the SCALE code system for nuclear analysis and COBRA-SFS for thermal analysis. Also, within the data and tools area is the Next Generation System Analysis Model (NGSAM), which is an agent-based simulation software tool expressly designed to be capable of modeling the waste management system, including the transportation of UNF to and from a FSF. NGSAM has been developed to enable informed decision-making by providing the capability to analyze various potential system options for the management of UNF and high-level radioactive waste. Finally, in the systems engineering execution area, the team has begun to apply a disciplined systems engineering approach at the system level along with supporting analysis to guide the development of the FSF project requirements (including associated transportation infrastructure). Systems engineering principles and practices and their adaptation/application to design and development activities will ensure that the waste management system is effectively implemented as work proceeds. Other activities include investigating the implications of changes in various assumptions and parameters related to waste management systems, such as UNF acceptance rates, receipt logic, facility capacities and capabilities, use of standardized canisters, and different assumed facility operation start dates. Keywords: federal staging facility (FSF), used nuclear fuel (UNF), integrated waste management (IWM) system, Next Generation System Analysis Model (NGSAM), STANDARDS, systems engineering

Joseph, Robert↗

Upgrading Biogas through in situ Conversion of Carbon Dioxide to Biomethane in Anaerobic Digesters

Organic waste streams generated by wastewater treatment plants, agricultural operations, and food processing industries represent an important yet underutilized opportunity for renewable energy production in the United States. Through anaerobic digestion, these waste streams can produce biogas, a mixture primarily composed of methane (CH4) and carbon dioxide (CO2), that can be upgraded to pipeline-quality natural gas. However, most existing upgrading technologies remove CO2 from biogas rather than utilizing it, leaving a significant portion of the potential energy unused. This project investigates a novel biological upgrading approach that converts CO2 into additional CH4 by supplying hydrogen (H2) to specialized microorganisms capable of performing hydrogenotrophic methanation. The main challenges associated with biological biogas upgrading are related to hydrogen supply, gas-liquid mass transfer, and process stability. First, due to the high cost of hydrogen gas, it is preferable that H2 be produced on-site using renewable energy sources such as wind or solar power. Second, hydrogen has low solubility in liquids, which limits its availability to microorganisms and requires strategies to improve gas dissolution and transfer within the reactor. Third, process inhibition may occur as a result of increased pH caused by CO2 consumption or elevated H2 partial pressure, both of which can negatively affect methanogenic activity. Although research in these areas has advanced during the course of this project, these challenges have not yet been fully resolved. To date, the biological systems that have achieved the highest methane concentrations are typically ex-situ reactors, where operational conditions can be more easily controlled. For this reason, the findings of the present project remain highly relevant. The project goal was to develop an innovative system that can accomplish biogas upgrading via biological conversion of CO2 to CH4, in a novel hybrid approach that combines the advantages of both in-situ and ex-situ systems. The proposed system employs a three-phase upflow anaerobic bioreactor with H2 delivery through a gas-permeable membrane, enabling efficient hydrogen transfer and microbial conversion. Under optimized operating conditions, the system achieved 99% H2 consumption and 90% CO2 conversion. A subsequent gas cleaning stage was implemented to further improve gas quality and meet target purity standards. The upgraded gas composition reached 97.7% CH4, 2.2% CO2, and 0.97% O2, while H2S concentrations remained below detection limits. In addition, a flue gas-driven inorganic thermoelectric generator (TEG) system was designed and experimentally validated as a potential source of electricity for H2 production. The system consisted of six TEG modules connected in series and achieved an open-circuit voltage of 4.5 V and a maximum power output of 224 mW at a temperature difference of approximately 53.5 °C, demonstrating effective conversion of waste heat into electrical power under simulated flue gas conditions. Finally, a comprehensive techno-economic analysis was completed to evaluate the capital and operating costs associated with the proposed system. The results provide important insights to guide future scale-up, optimization, and potential deployment of integrated biological biogas upgrading technologies.

09 BIOMASS FUELS↗

Power Analysis of an ePump Applied to the Linear Functions of an Agricultural Planter

Like many other industries, the agricultural industry has recently ex-perienced pressure to reduce vehicle emissions while improving productivity. Electric actuation is perceived as a viable solution to replace or augment hydrau-lic and mechanical actuation. However, electrification presents challenges with regards to linear functions, where hydraulic actuators have advantages in terms of compactness, tolerance to contamination and resistance to shocks. A combined electro-hydraulic actuation architecture can leverage the benefits of both electric and hydraulic actuation, while reducing the drawbacks of both approaches. This work investigates the potential of a centralized electric driven pump (ePump) system powering the pressure-controlled linear functions of an agricul-tural planter, with the goal of improving the operating point of the main supply pump. In this application, the rotary functions are hydraulically actuated, alt-hough such a solution could be applied also to electric rotary actuation. This is accomplished by setting the ePump to boost the pressure supplied by the tractor to the level required by the linear functions. An accumulator is used to stabilize the flow requirements of the linear functions, and control the pressure supplied to the actuators. Two control schemes are proposed for the regulation of the ac-cumulator pressure, one favoring an efficient operating point for the ePump, the other favoring stable steady state operation. A simulation model of the baseline system and proposed system is developed and validated using experimental data from a full-scale machine. Using the vali-dated simulation, both control architectures are then evaluated for improvement in system power consumption and dynamic requirements on the ePump to assess their effectiveness. Both systems demonstrate significant improvement in power consumption over the baseline system, with the best solution improving effi-ciency by 64%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Benchmark Case for the Grid Survivability Analysis

Among current priorities of the power system analysis is the development of metrics and computational tools for the resilience analysis during catastrophic events. New methods and tools are required for such an analysis and they have to be validated prior application to real systems. However, benchmark problems are not readily available due to the analysis novelty. The current paper presents a case based on the IEEE 14-bus system for this purpose. The grid is simplified to a graph with nodes representing generators, loads, and buses. Power inputs are imported from real-time simulations of the IEEE 14-bus system. Outcomes of all possible combinations of failed elements are presented in terms of probabilities for the grid to survive, partially survive, or fail. Only the power grid's ability to withstand adverse events (survivability) is analyzed. The grid's recoverability, the other part of the resilience analysis, is not considered.

power system↗

EGS Collab Experiment 2: Microseismic Monitoring

This dataset contains continuous seismic waveform data recorded during stimulation and thermal circulation tests for the Enhanced Geothermal Systems (EGS) Collab Experiment #2, conducted from February to September 2022 at the Sanford Underground Research Facility in Lead, South Dakota. This experiment aimed to study and validate models of geothermal systems by injecting high-pressure fluids into rock formations 1200-1500 meters below the surface, inducing microseismic events. The seismic monitoring system included 16 three-component accelerometers and a 24-channel hydrophone array, installed in boreholes surrounding the test area. Data were recorded at high sampling rates using a continuous waveform recording system to monitor seismic activity in real time. The dataset contains the raw data stored in binary format, with files named based on timestamps, and includes calibration certificates for some sensors to facilitate corrections to real units. Users are strongly advised to consult the accompanying detailed report, which outlines the experimental setup, sensor specifications, installation procedures, and data processing methods. The report also describes important nuances, such as the hardware filters on hydrophones, sensor calibration details, and the naming conventions for the recorded data. Proper use of this dataset may require familiarity with seismic data analysis tools, such as the Obspy Python package, and an understanding of the SEED naming conventions used for channel identification.

15 GEOTHERMAL ENERGY↗

Quantification of storage required for preserving frequency security in wind‐integrated systems

Abstract The penetration of wind power generation into the power grid has been accelerated in recent times due to the aggressive emission targets set by governments and other regulatory authorities. Although wind power has the advantage of being environment‐friendly, wind as a resource is intermittent in nature. In addition, wind power contributes little inertia to the system as most wind turbines are connected to the grid via power electronic converters. These negative aspects of wind power pose serious challenges to the frequency security of power systems as penetration increases. In this work, an approach is proposed where an energy storage system (ESS) is used to mitigate frequency security issues of wind‐integrated systems. ESSs are well equipped to supply virtual inertia to the grid due to their fast‐acting nature, thus replenishing some of the energy storage capability of displaced inertial generation. In this work, a probabilistic approach is proposed to estimate the amount of inertia required by a system to ensure frequency security. Reduction in total system inertia due to the displacement of conventional synchronous generation by wind power generation is considered in this approach, while also taking into account the loss of inertia due to forced outages of conventional units. Monte Carlo simulation is employed for implementing the probabilistic estimation of system inertia. An ESS is then sized appropriately, using the system swing equation, to compensate for the lost inertia. The uncertainty associated with wind energy is modeled into the framework using an autoregressive moving average technique. Effects of increasing the system peak load and changing the wind profile on the expected system inertia are studied to illustrate various factors that might affect system frequency security. The proposed method is validated using the IEEE 39‐bus test system.

17 WIND ENERGY↗

Transactive Electric Water Heater Agent: Design and Performance Evaluation

Electric water heaters (EWHs) are usually equipped with inbuilt thermostats to measure water temperature near the installed positions. Most of the existing EWHs have only two thermostats and often do not have water flow sensor installed. Estimation of state of heat energy (SOHE) inside the hot water tank, which is crucial for efficient control and operation of the EWH, under such imperfect system conditions is very challenging. This paper, therefore, designs a transactive EWH agent (TEWHA) to better estimate SOHE in presence of measurement errors and imperfect system knowledge. The TEWHA, built-in Python, approximates the EWH physics using limited measurements obtained from the ground truth GridLABD model. The performance of the TEWHA is validated against ground truth system for three scenarios: a) ideal condition where TEWHA has complete knowledge of the system, b) imperfect condition where TEWHA has incomplete system information, and c) noised condition where TEWHA measurements contain random errors. Finally, an optimization problem is formulated and solved to demonstrate how TEWHA could use the estimated and measured parameters for a transactive control of EWH. Index Terms—Demand flexibility

demand flexibility, distribution system, electric ↗

TEAMER: Triton Systems Oscillating Water Column Modeling Data and Report

This dataset provides the output of six Wave Energy Converter Simulator (WEC-Sim) simulations and accompanying documentation for the modeling of Triton Systems' oscillating water column (OWC) system at tank scale (validated using available data for tuning the model, Tests 1-2) and deployment scale (for which no validation data is available, Tests 4-6). Included are the output data in a MATLAB file structure, a comprehensive report on the modeling and design of the Triton OWC system, and a link to the WEC-Sim GitHub page. This work was supported by funding from TEAMER RFTS 5 (Request for Technical Support).

16 TIDAL AND WAVE POWER↗

Organic Rankine Cycle Integration and Optimization for High Efficiency CHP Genset Systems (Final Technical Report)

This project successfully advanced the integration of Organic Rankine Cycle (ORC) technology with reciprocating engine–based combined heat and power (CHP) systems to improve electrical efficiency, total CHP efficiency, and grid-responsive operation. Over three budget periods, the work progressed from high-temperature ORC component development and thermodynamic model validation to next-generation system design, working fluid transition, and techno-economic analysis. Key technical accomplishments include development and validation of a thermodynamic model capable of accurately predicting ORC performance across an expanded temperature and pressure envelope; successful identification and validation of low-global-warming-potential (GWP) working fluids—most notably R1233zd(E)—as viable replacements for R245fa; and demonstration of scalable ORC architectures suitable for integration with 1–20 MW class reciprocating engines. These advances enable flexible CHP configurations that can increase electrical output while maintaining high overall utilization of available thermal energy. The project also produced a clean-sheet design for a next-generation ORC system targeting substantially higher power output per unit, supported by detailed component selection, heat exchanger evaluation, and system-level modeling. Techno-economic analyses indicate that ORC-enabled flexible CHP systems can meet or exceed Department of Energy (DOE) efficiency targets while providing value to both facility operators and the electric grid.. Late-stage testing of the largest next-generation ORC prototype identified limitations related to pump net positive suction head (NPSH) requirements and condenser flooding under certain operating conditions. Although these issues constrained full validation of that configuration within the project timeframe, they provided clear and actionable design guidance for future system refinements. Importantly, validated modeling, smaller-scale testing, and working fluid evaluations confirmed the technical viability of the overall approach. In aggregate, this project met its core objectives by establishing validated design tools, de-risking key ORC technologies for CHP applications, and defining a credible pathway toward commercialization of flexible, high-efficiency CHP systems. The results form a strong foundation for continued development and deployment beyond the conclusion of the DOE-funded effort.

20 FOSSIL-FUELED POWER PLANTS↗

Design of an Online Electrochemical Mass Spectrometry System to Study Gas Evolution from Cells with Lean and Volatile Electrolytes

Gas evolution in high-energy Li-ion batteries remains a pervasive problem for a multitude of chemistries, jeopardizing the electrochemical performance and safety for consumers of electric vehicles. Many electrode–electrolyte degradation processes evolve gasses that may be detected in-situ with online electrochemical mass spectrometry (OEMS). In this work, details are provided for the setup and validation of an OEMS system that operates well under lean and volatile electrolyte conditions. Quite notably, the OEMS cells with only 40 µL of electrolyte and intermittent headspace sampling exhibit comparable electrochemical performance to flooded coin-cells. It is demonstrated that the onset time, shape, and magnitude of the gas evolution profiles calculated from mass spectrometer measurements match well to a known pressure reference through the use of an empirically determined fraction of removal. The off-gassing characteristics from a set of layered-oxide materials, NMC532, NMC811, and LNO, are used to further validate the OEMS setup against the literature. It is shown that many of the features present in the OEMS curves for equivalent systems from other groups are captured by this OEMS system. Finally, at an upper cut-off voltage of 4.4 V, LNO exhibits an intense release of CO 2 , O 2 , and CO gas relative to NMC532 and NMC811.

25 ENERGY STORAGE↗

Deployment of the Finite Volume Method in Pronghorn for Gas and Salt cooled Pebble Bed Reactors

This report summarizes the activities related to ”Complete FHR and HTGR pebble bed simulator, including initial validation” funded by the NEAMS thermal-hydraulics focus area. The activity revolves around the coarse-mesh thermal-hydraulics code Pronghorn and its application to gas and salt cooled Pebble bed reactor (PBR). The main difference between gas and salt cooled PBR from a thermal-hydraulics perspective is the fluid. To address the difference in fluid behavior, two separate approaches are implemented in the MOOSE Navier Stokes module: 1) a Boussinesq approximation and 2) a fully compressible formulation. The developed finite volume method capabilities are used for improving pre-existing gas-cooled and salt-cooled pebble-bed reactor models. A steady-state, multiphysics gas-cooled pebble-bed reactor model is created that couples the equilibrium core depletion capability developed in previous work, and the finite volume method capability developed for this report. The salt-cooled pebble-bed reactor model is upgraded to use the incompressible finite volume method capability and then extended to three spatial dimensions. Finally, several verification-and-validation exercises performed with Pronghorn are documented using the verification-and-validation report of the MooseDoc system. The goal of this effort to document the verification-and-validation level of Pronghorn and improve stakeholder confidence in the results obtained with Pronghorn.

97 MATHEMATICS AND COMPUTING↗

Double Quarter Wave Crab Cavity Wire Stretching Measurement at BNL

The Double Quarter Wave (DQW) crab cavity is one out of the two crab cavities within Work Package 4 of the LHC (Large Hadron Collider) Hi-Lumi Program, and the RF design of the cavity was originally supported by the US LHC Accelerator Research Program (LARP) and later the LHC Accelerator Upgrade Program (AUP) funded by the DOE High Energy Physics Office in the Office of Science. Brookhaven National Laboratory (BNL) has delivered the successful DQW crab cavity RF design, and worked actively with all. The wire stretching measurement was completed on the prototype DQW crab cavity for operation practice and calibration of the measurement system. Four locations were defined to be on the electrical center plane of the crab cavity, and survey of the wire indicated all are on the same plane. The successful measurement validated the wire stretching system built at Brookhaven National Lab. The offset of the four wire locations to the fitted plane provided the error of the measurement.

43 PARTICLE ACCELERATORS↗

Squeeze Film Damper Experimental and Numerical Correlation: Test Setup Description and Parameter Identification of Dry System

The process of characterizing a damper involves both experimental techniques and model simulation. Experiments characterize dynamic behavior of a system through empirical modal analysis using impact and shaker testing. The layout of the test setup is crucial for a low-mass, nonlinear system. Physical arrangement, orientation of the system, and instrumentation affect the results that are discussed in this paper. These results can be used to validate a numerical simulation of the same system. With a validated model, important physical input parameters and modeling techniques can be determined and implemented in future designs. In other words, this modeling can be used with confidence to design alternative dampers that may be difficult, costly, and time-consuming to characterize experimentally.

Cook, Jason↗

Quantitative Power System Resilience Metrics and Evaluation Approach: Preprint

Power system resilience is an emerging topic and plays an essential role in helping power industry understand and respond to the increasing threats of extreme weather events. The first step of power system resilience analysis is to introduce metrics to quantify the resilience reasonably. Existing resilience metrics are typically restrained by the limited data for extreme event modeling and fall short in terms of physical interpretation and comparability. This paper develops novel quantitative metrics to evaluate power system resilience in pre- and post-event contexts. The developed metrics illustrate clear physical meanings and can be effectively used to compare resilience across different systems under different extreme events. Moreover, the developed metrics can be applied to both transmission and distribution systems. Simulation on a distribution system is employed to validate the effectiveness of the proposed resilience metrics and resilience evaluation approach.

power system resilience↗

Robust Resilient Signal Reconstruction under Adversarial Attacks

We consider the problem of signal reconstruction for a system under sparse signal corruption by a malicious agent. The reconstruction problem follows the standard error coding problem that has been studied extensively in the literature. We include a new challenge of robust estimation of the attack support. The problem is then cast as a constrained optimization problem merging promising techniques in the area of deep learning and estimation theory. A pruning algorithm is developed to reduce the "false positive" uncertainty of data-driven attack localization results, thereby improving the probability of correct signal reconstruction. Sufficient conditions for the correct reconstruction and the associated reconstruction error bounds are obtained for both exact and inexact attack support estimation. Moreover, a simulation of a water distribution system is presented to validate the proposed techniques.

Robust, Signal reconstruction, Resilient estimator↗

Thermal and electric multidomain dynamic model for integration of power grid distribution with behind-the-meter devices

As renewable energy sources like solar and wind power become more integrated into the grid, coordinated control of behind-the-meter devices is crucial for enhancing grid flexibility and reliability and for meeting cost targets, with standardized models being developed to support this transition. The increasing flexibility and uncertainty of integrated renewable energy grids, along with interactions between various subsystems, make traditional steady-state modeling insufficient to capture transient and dynamic behaviors. Current models (e.g., composite load and battery equivalent models) focus on thermodynamic or electrical characteristics but overlook critical electromechanical interactions. This limits the ability to share performance information for grid services and hampers fast dynamic simulations. In addition, motor stalling is usually triggered by a fault event and attributed to the characteristics of the mechanical torque of the motor, resulting in absorption of a large amount of reactive power during the stalling period. Further, this significant withdrawal of reactive power will deteriorate the dynamic voltage stability of power grids and cause delayed voltage recovery. Therefore, an in-depth modeling of the thermodynamics or mechanical torque is essential to study the impacts of the realistic torque characteristics of those behind-the-meter devices on power system voltage stability. This study developed a dynamic multidomain model for building HVAC systems, such as air-source heat pumps, to simulate their thermal and electrical responses to grid transients. The model can accurately predict power metrics with a mean absolute percentage error of 10%, by validating against with power system computer-aided design performance data. Case studies demonstrate the model capability of capturing the transient response to sudden voltage changes, rapid load fluctuations, and system shutdowns respectively. During a sudden voltage drop (30% for 0.1s), a fully loaded heat pump’s motor speed dropped, continued declining, and shut down after 3.6s, with severe power oscillations and a torque spike. A partially loaded unit experienced temporary oscillations but stabilized. Under higher building loads, compressor speed increased from 64% to 100%, with power and torque rising before stabilizing. In safety-triggered shutdowns, power decreased after minor fluctuations, and torque briefly spiked before dropping to zero.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparative Study and Validation of Photovoltaic Model Formulations for the IBPSA Modelica Library based on Rooftop Measurement Data

Domain-overarching system models are crucial to investigate sector coupling concepts. Specifically, the coupling of building and electrical energy systems becomes crucial to integrate renewable energy sources such as photovoltaic power systems (PV). For such interdisciplinary simulation models, Modelica is a suitable language. However, most open-source Modelica libraries are either domain-specific or lack simple-to-parameterize PV models. We close this gap by developing a PV model for the IBPSA Modelica library. The model comprises two I-V-characteristic models and three mounting-dependent approaches to calculate the cell temperature. The I-V-characteristic models follow a single- and two-diodes approach. This study uses measurement data from a rooftop PV system in Berlin, Germany, for validation. The focus lies on comparing the implemented single- and two-diodes approach. Results prove that both models accurately calculate the modules’ DC power output and cell temperature. The two-diodes approach slightly outperforms the single-diode one at the expense of a higher parameterization effort.

Maier, Laura↗