Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “structural panels”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Repeated buckling of composite shear panels

Failures in service of aerospace structures and research at the Technion Aircraft Structures Laboratory have revealed that repeatedly buckled stiffened shear panels might be susceptible to premature fatigue failures. Extensive experimental and analytical studies have been performed at Technion on repeated buckling, far in excess of initial buckling, for both metal and composite shear panels with focus on the influence of the surrounding structure. The core of the experimental investigation consisted of repeated buckling and postbuckling tests on Wagner beams in a three-point loading system under realistic test conditions. The effects of varying sizes of stiffeners, of the magnitude of initial buckling loads, of the panel aspect ratio and of the cyclic shearing force, V sub cyc, were studied. The cyclic to critical shear buckling ratios, (V sub cyc/V sub cr) were on the high side, as needed for efficient panel design, yet all within possible flight envelopes. The experiments were supplemented by analytical and numerical analyses. For the metal shear panels the test and numerical results were synthesized into prediction formulas, which relate the life of the metal shear panels to two cyclic load parameters. The composite shear panels studied were hybrid beams with graphite/epoxy webs bonded to aluminum alloy frames. The test results demonstrated that composite panels were less fatigue sensitive than comparable metal ones, and that repeated buckling, even when causing extensive damage, did not reduce the residual strength by more than 20 percent. All the composite panels sustained the specified fatigue life of 250,000 cycles. The effect of local unstiffened holes on the durability of repeatedly buckled shear panels was studied for one series of the metal panels. Tests on 2024 T3 aluminum panels with relatively small unstiffened holes in the center of the panels demonstrated premature fatigue failure, compared to panels without holes. Preliminary tests on two graphite epoxy shear panels with small holes in the center showed no similar fatigue life degradation and no shift in failure mode. Further tests on the effect of holes are in progress.

Singer, Josef↗

Structural and Acoustic Numerical Modeling of a Curved Composite Honeycomb Panel

The finite and boundary element modeling of the curved section of a composite honeycomb aircraft fuselage sidewall was validated for both structural response and acoustic radiation. The curved panel was modeled in the pre-processor MSC/PATRAN. Geometry models of the curved panel were constructed based on the physical dimensions of the test article. Material properties were obtained from the panel manufacturer. Finite element models were developed to predict the modal parameters for free and supported panel boundary conditions up to a frequency of 600 Hz. Free boundary conditions were simulated by providing soft foam support under the four comers of the panel or by suspending the panel from elastic bands. Supported boundary conditions were obtained by clamping the panel between plastic tubing seated in grooves along the perimeter of a stiff and heavy frame. The frame was installed in the transmission loss window of the Structural Acoustic Loads and Transmission (SALT) facility at NASA Langley Research Center. The structural response of the curved panel due to point force excitation was predicted using MSC/NASTRAN and the radiated sound was computed with COMET/Acoustics. The predictions were compared with the results from experimental modal surveys and forced response tests on the fuselage panel. The finite element models were refined and updated to provide optimum comparison with the measured modal data. Excellent agreement was obtained between the numerical and experimental modal data for the free as well as for the supported boundary conditions. Frequency response functions (FRF) were computed relating the input force excitation at one panel location to the surface acceleration response at five panel locations. Frequency response functions were measured at the same locations on the test specimen and were compared with the calculated FRF values. Good agreement was obtained for the real and imaginary parts of the transfer functions when modal participation was allowed up to 3000 Hz. The validated finite element model was used to predict the surface velocities due to the point force excitation. Good agreement was obtained between the spatial characteristics of the predicted and measured surface velocities. The measured velocity data were input into the acoustic boundary element code to compute the sound radiated by the panel. The predicted sound pressure levels in the far-field of the panel agreed well with the sound pressure levels measured at the same location.

Grosveld, Ferdinand W.↗

Structure, function, and inhibition of drug reactivating human gut microbial β-glucuronidases

Bacterial β-glucuronidase (GUS) enzymes cause drug toxicity by reversing Phase II glucuronidation in the gastrointestinal tract. While many human gut microbial GUS enzymes have been examined with model glucuronide substrates like p-nitrophenol-β-D-glucuronide (pNPG), the GUS orthologs that are most efficient at processing drug-glucuronides remain unclear. Here we present the crystal structures of GUS enzymes from human gut commensals Lactobacillus rhamnosus, Ruminococcus gnavus , and Faecalibacterium prausnitzii that possess an active site loop (Loop 1; L1) analogous to that found in E. coli GUS, which processes drug substrates. We also resolve the structure of the No Loop GUS from Bacteroides dorei. We then compare the pNPG and diclofenac glucuronide processing abilities of a panel of twelve structurally diverse GUS proteins, and find that the new L1 GUS enzymes presented here process small glucuronide substrates inefficiently compared to previously characterized L1 GUS enzymes like E. coli GUS. We further demonstrate that our GUS inhibitors, which are effective against some L1 enzymes, are not potent towards all. Our findings pinpoint active site structural features necessary for the processing of drug-glucuronide substrates and the inhibition of such processing.

60 APPLIED LIFE SCIENCES↗

A nonlinear analysis of infinitely long graphite-epoxy cylindrical panels loaded with internal pressure

The structural response of internally pressurized composite cylindrical panels, representative of a transport aircraft's fuselage skins, is predicted by means of a one-dimensional, geometrically nonlinear analysis. An analytical study is conducted for the response of 4-, 8-, and 16-ply graphite/epoxy skins. The results obtained indicate that the response is geometrically nonlinear, and that a boundary layer with a severe bending gradient exists at the panel edges. The importance of through-the-thickness shearing deformations in the bending boundary layer is illustrated through comparison of analyses based on Kirchhoff-Love and shear deformation theories. Numerical results for the bending boundary layer lengths of the different panels are presented, and two bending boundary layers are predicted with the shear deformation theory.

Boitnott, R. L.↗

Experimental Behavior of Fatigued Single Stiffener PRSEUS Specimens

NASA, the Air Force Research Laboratory and The Boeing Company have worked to develop new low-cost, light-weight composite structures for aircraft. A Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS) concept has been developed which offers advantages over traditional metallic structure. In this concept a stitched carbon-epoxy material system has been developed with the potential for reducing the weight and cost of transport aircraft structure by eliminating fasteners, thereby reducing part count and labor. By adding unidirectional carbon rods to the top of stiffeners, the panel becomes more structurally efficient. This combination produces a more damage tolerant design. This document describes the results of experimentation on PRSEUS specimens loaded in unidirectional compression in fatigue and to failure.

Jegley, Dawn C.↗

Influence of Impact Damage on Carbon-Epoxy Stiffener Crippling

NASA, the Air Force Research Laboratory and The Boeing Company have worked to develop new low-cost, light-weight composite structures for aircraft. A Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS) concept has been developed which offers advantages over traditional metallic structure. In this concept a stitched carbon-epoxy material system has been developed with the potential for reducing the weight and cost of transport aircraft structure by eliminating fasteners, thereby reducing part count and labor. By adding unidirectional carbon rods to the top of stiffeners, the panel becomes more structurally efficient. This combination produces a more damage tolerant design. This document describes the results of experimentation on PRSEUS specimens loaded in unidirectional compression subjected to impact damage and loaded in fatigue and to failure. A comparison with analytical predictions for pristine and damaged specimens is included.

Jegley, Dawn C.↗

Study of advanced composite structural design concepts for an arrow wing supersonic cruise configuration

Based on estimated graphite and boron fiber properties, allowable stresses and strains were established for advanced composite materials. Stiffened panel and conventional sandwich panel concepts were designed and analyzed, using graphite/polyimide and boron/polyimide materials. The conventional sandwich panel was elected as the structural concept for the modified wing structure. Upper and lower surface panels of the arrow wing structure were then redesigned, using high strength graphite/polyimide sandwich panels, retaining the titanium spars and ribs from the prior study. The ATLAS integrated analysis and design system was used for stress analysis and automated resizing of surface panels. Flutter analysis of the hybrid structure showed a significant decrease in flutter speed relative to the titanium wing design. The flutter speed was increased to that of the titanium design by selective increase in laminate thickness and by using graphite fibers with properties intermediate between high strength and high modulus values.

Turner, M. J.↗

Easy Attachment Of Panels To A Truss

Conceptual antenna dish, solar collector, or similar structure consists of hexagonal panels supported by truss erected in field. Truss built in increments to maintain access to panel-attachment nodes. Each panel brought toward truss at angle and attached to two nodes. Panel rotated into attachment at third node.

Thomson, Mark↗

Metal Foam Shields

This paper compares the ballistic performance of metallic foam sandwich structures with honeycomb structures. Honeycomb sandwich structures, consisting of metallic or composite facesheets and honeycomb cores, are often used in spacecraft construction due to their light-weight and structural stiffness. Honeycomb panels, however, are considered rather poor candidates for protection from micrometeoroid orbital debris (MMOD) particles because the honeycomb channels the debris cloud from MMOD impacts on outer facesheet causing a concentrated load on the second facesheet. Sandwich structures with light-weight, open-cell metallic cores and metal or composite facesheets provide improved MMOD protection because channeling does not occur and because the core is more effective at disrupting hypervelocity impacts then honeycomb. This paper describes hypervelocity impact tests on metallic foam sandwich structures (aluminum and titanium) with metallic facesheets, compare them to equivalent mass and thickness honeycomb panels, based on the results of hypervelocity impact tests.

Christiansen, Eric L.↗

Lunar landing and launch facilities and operations

A preliminary design of a lunar landing and launch facility for a Phase 3 lunar base is formulated. A single multipurpose vehicle for the lunar module is assumed. Three traffic levels are envisioned: 6, 12, and 24 landings/launches per year. The facility is broken down into nine major design items. A conceptual description of each of these items is included. Preliminary sizes, capacities, and/or other relevant design data for some of these items are obtained. A quonset hut tent-like structure constructed of aluminum rods and aluminized mylar panels is proposed. This structure is used to provide a constant thermal environment for the lunar modules. A structural design and thermal analysis is presented. Two independent designs for a bridge crane to unload/load heavy cargo from the lunar module are included. Preliminary investigations into cryogenic propellant storage and handling, landing/launch guidance and control, and lunar module maintenance requirements are performed. Also, an initial study into advanced concepts for application to Phase 4 or 5 lunar bases has been completed in a report on capturing, condensing, and recycling the exhaust plume from a lunar launch.

Source record↗

Shuttle Experimental Radar for Geological Exploration (SERGE); antenna and integration concept definition study

The baseline configuration defined has the SERGE antenna panel array mounted on the OFT-2 pallet sufficiently high in the bay that negligible amounts of radiation from the beam are reflected from orbiter surfaces into the shuttle payload bay. The array is symmetrically mounted to the pallet along the array long dimension with the pallet at the center. It utilizes a graphite epoxy trusswork support structure. The antenna panels are of SEASAT engineering model design and construction. The antenna array has 7 panels and a 7-way naturally tapered coax corporate feed system. The performance of the system is predicted to exceed 33 db gain, have -15 db sidelobes in the E-plane and even lower in the H-plane, and have and E-plane beamwidth less than 2.2 deg, all within performance specification. The primary support structure is predicted to exceed the specified greater than 25 hertz fundamental frequency, although individual panels will have hertz fundamental frequency.

Kierein, J. W.↗

Heat Exchanger For Rotating Modular Structures

Heat exchanger transfers heat from one structure to another while accommodating rotary motion of structures. Flat-panel heat exchanger passes heat from fluid in middle panel to fluid in outer panels. Diaphragm-like outer panels swell to conform to surfaces of middle panel, ensuring thermal contact. Rotary fluid coupling provides connection for both supply fluid and return fluid. Flexible hoses carrying fluid to and from coupling accommodate tilt of one structure with respect to other. Adapted to transfer of fluids and heat across joints of machine tools and robot arms and to flow of coolant through portable electronic equipment.

Clark, William E.↗

TPSAS-NF1676L-13539-DND

The performance of variable stiffness composite panels is characterized using experiments and structural analyses. Fabricated using a fiber placement system, the fiber angle in these panels varies continuously within each ply. Measured panel shapes and thermal responses are correlated with finite element analyses. Large geometric imperfections require unique fixtures to both straighten the panel edges and provide structural test boundary conditions. Panels show linear prebuckling and nonlinear postbuckling under applied end shortening, which occur at higher loads than a baseline panel. Panel responses to in-plane loading are computed using geometric and materially nonlinear analyses that include mechanical prestresses and measured imperfections. Analytical strains and displacements also correlate well with measured results.

Chauncey Wu↗

Hybrid deployable support truss designs for LDR

Concepts for a 20-meter diameter Large Deployable Reflector (LDR) deployable truss backup structure, and analytical predictions of its structural characteristics are discussed. The concept shown is referred to as the SIXPAC; It is a combination of the PACTRUSS concept and a single-fold beam, which would make up the desired backup structure. One advantage of retaining the PACTRUSS concept is its packaging density and its capability for synchronous deployment. Various 2-meter hexagonal panel arrangements are possible for this Hybrid PACTRUSS structure depending on the panel-to-structure attachment strategies used. Static analyses of the SIXPAC using various assumptions for truss designs and panel masses of 10 kg sq meters were performed to predict the tip displacement of the structure when supported at the center. The tip displacement ranged from 0.20 to 0.44 mm without the panel mass, and from 0.9 to 3.9 mm with the panel mass (in a 1-g field). The data indicate that the structure can be adequately ground tested to validate its required performance in space, assuming the required performance in space is approximately 100 microns. The static displacement at the tip of the structure when subjected to an angular acceleration of 0.001 rad/sec squared were estimated to range from 0.8 to 7.5 microns, depending on the type of truss elements.

Hedgepeth, J.↗

Thermal fatigue tests of a radiative heat shield panel for a hypersonic transport

A pair of corrugation stiffened, beaded skin Rene 41 heat shield panels were exposed to 20,000 thermal cycles between room temperature and 1450 F to evaluate the thermal fatigue response of Rene 41 metallic heat shields for hypersonic cruise aircraft applications. At the conclusion of the tests, the panels retained substantial structural integrity; however, there were cracks and excessive wear in the vicinity of fastener holes and there was an 80-percent loss in ductility of the skin. Shrinkage of the panel which caused the cracks and wear must be considered in design of panels for Thermal Protection Systems (TPS) applications.

Webb, Granville L.↗

Buckling behavior and structural efficiency of open-section stiffened composite compression panels

Several experiments with J- and blade-stiffened graphite/epoxy panels were conducted to obtain insight into how well experimental data could be correlated with analysis for the buckling behavior of open-section stiffened composite compression panels. Although some nonlinear behavior was observed during the experiments, adequate correlation with analysis was obtained to justify the use of linear, thin-plate buckling analysis in a minimum-weight design synthesis program for J- and blade-configurations. Results from two design studies using this program are presented. In the first study the minimum weights of Jand blade-configurations for two different material systems (graphite/epoxy and aluminum) are determined subject to buckling and strength constraints for a wide range of the compressive load index. In the second study the minimum weights required for graphite/epoxy blade-stiffened panels to satisfy additional stiffness constraints typical of medium-size commercial aircraft wing structures are determined. Both minimum-weight studies indicate that graphite/epoxy open-section stiffened panels can be designed so that weight savings of 30 to 50% are possible compared with the most efficient aluminum designs.

Williams, J. G.↗

Detailed analysis and test correlation of a stiffened composite wing panel

Nonlinear finite element analysis techniques are evaluated by applying them to a realistic aircraft structural component. A wing panel from the V-22 tiltrotor aircraft is chosen because it is a typical modern aircraft structural component for which there is experimental data for comparison of results. From blueprints and drawings supplied by the Bell Helicopter Textron Corporation, a very detailed finite element model containing 2284 9-node Assumed Natural-Coordinate Strain (ANS) elements was generated. A novel solution strategy which accounts for geometric nonlinearity through the use of corotating element reference frames and nonlinear strain displacements relations is used to analyze this detailed model. Results from linear analyses using the same finite element model are presented in order to illustrate the advantages and costs of the nonlinear analysis as compared with the more traditional linear analysis. Strain predictions from both the linear and nonlinear stress analyses are shown to compare well with experimental data up through the Design Ultimate Load (DUL) of the panel. However, due to the extreme nonlinear response of the panel, the linear analysis was not accurate at loads above the DUL. The nonlinear analysis more accurately predicted the strain at high values of applied load, and even predicted complicated nonlinear response characteristics, such as load reversals, at the observed failure load of the test panel. In order to understand the failure mechanism of the panel, buckling and first ply failure analyses were performed. The buckling load was 17 percent above the observed failure load while first ply failure analyses indicated significant material damage at and below the observed failure load.

Davis, D. Dale, Jr.↗