Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “steam power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigation of Process Emissions during Thermal Cutting of Clad Metals from the Nuclear Sector - 20183

Typically, reactor pressure vessels as well as steam generators comprising low alloyed steel with a cladding of stainless steel. Recently the permissible values for Cr (VI) in the air of the working areas have been reduced in Germany from 100 μg/m{sup 3} to 1 μg/m{sup 3} air. This results in the danger that even with low-alloy steel with claddings these limit values would be exceeded when using flame cutting technologies. In order to ensure compliance with the permissible limit values, exhaust gas systems with gas cleaning measures are provided. The process emission test shall replace the assumptions required for the design of these systems with measured values. NUKEM Technologies Engineering Services GmbH (NUKEM) has chosen autogenous flame cutting as an example of a thermal cutting system for process emission testing, as there are no proven values in the literature for the Cr (VI) and NiOx emissions produced. The autogenous flame cutting can be used for a variety of cutting tasks within decommissioning projects. In order to simulate the material to be cut, mock ups were generated and cut from information about the material specification for the reactor pressure vessel from existing nuclear power plants including possible claddings. The cutting length needed for analysis in the test will be maximum 100 mm. The airborne emissions from the thermal cutting process will be captured and analyzed as follows: - Dust emission: The generated particles will be collected by a hood equipped with strong suction device and suitable filter elements. The resulting filter is gravimetrically measured before and after the tests. - Particle Size Distribution: The airborne particle size distribution measurement will result in figures for the size and number of particles arising from the thermal cutting process. - Gas Analysis: The gas analysis enables the determination of e.g. CO{sub 2}, CO, O{sub 3}, NO, NO{sub 2}. - Cr (VI) and NiOx Analysis: For the Cr (VI) and NiOx analysis, samples of the filter residue will be taken. As a result Cr (VI) in relation to total Cr as well as the Ni content will be determined by ICP-optically emission spectroscopy and put in relation to the total dust amount. The process emissions test itself as well as the necessary gas analyses and spectroscopic analyses were carried out at the Institute of Materials Science (IW) of Leibniz Universitaet Hannover (LUH). The results of the process emission tests are used to confirm the design of the gas cleaning systems. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Accuracy Enhancement of Nuclear Power Plant Simulators Utilizing High Accuracy Simulation Predictions

More recently, reactor core simulators for core designs associated with commercial nuclear power plants that utilize what is believed to be higher fidelity models have been developed. Features such as neutronics models that utilize transport equation solvers with fine spatial meshes and many energy-groups, thermal-hydraulic models that utilize sub-channel solvers with fine spatial mesh and capable of treating a wide range of fluid conditions, and fuel-coolant chemistry interaction models capable of treating CRUD deposition are to be found in these higher fidelity core simulators. These reactor core simulators require access to higher performance computers, characterized by many processors, cores and large memory. So associated with utilization of these simulators is access to high performance computers and ability to accommodate in one’s workflow longer execution times. By contrast, currently used core simulators by the nuclear industry can execute on engineering workstations and have execution times of seconds to minutes. The desirability for having short execution times is not only desired for support of time critical tasks but supports the mental process of decision making by engineers. The goal of the work reported upon here has the objective of retaining the fidelity of higher fidelity models while retaining the ability to utilize engineering workstations. Beyond the core simulator goal, additional goals of this work include incorporating the just described core simulator capability into a Nuclear Steam Supply System (NSSS) simulator, and to incorporate the resulting capability into an environment supportive of design and operational decision making associated with nuclear power stations. The model selected for the core neutronics model is the NESTLE code, for the core thermal-hydraulic model is the CTF code utilizing coarse mesh, and for the NSSS model is the RELAP5-3D code. WSC’s proprietary 3KEYMASTERTM platform is being used to provide software coupling, user interface, visualization, and reporting. The NESTLE core neutronics simulator was first integrated with the CTF core thermal-hydraulic simulator using CTF developed communication commands which are also used for CTF to communicate with RELAP5-3D under WSC’s proprietary 3KEYMASTERTM platform. To assure NESTLE prediction consistency with higher fidelity core neutronic simulators, buffer codes have been created to automatically generate from output files written by the VERA core simulator the NESTLE nodal neutronic parameter’ library, geometry, and pin-power reconstruction input files, thereby avoiding a number of challenges associated with utilizing lattice physics codes and providing consistency with VERA predictions. To treat absorber rod effects a multi-set library is utilized, where a set refers to a specific absorber rod fully inserted pattern. A coarse spatial mesh CTF model was developed with features added that support using CTF as envisioned in the engineering quality simulator. A hybrid meshing approach was implemented to allow for automated construction of models with mixed levels of refinement. Specifically, a core model could resolve some assemblies at a nodal level (4 subchannels per assembly) and others at a pin-resolution (one subchannel per coolant subchannel in the assembly). The intention is that this will allow for better resolution of limiting conditions such as DNBR and PCT, which are based on local rod and subchannel conditions. Further development was done of features that enhance the capabilities for the envisioned engineering quality simulator that has been developed, but now for RELAP-3D. The RELAP5-3D code development includes ability to model more than 999 components and the addition of the cross-channels turbulence mixing model and the void drift model that are implemented in CTF, aiming to achieve closer prediction agreement of the two codes for transient simulations, specifically, more accurate matches of the overall mass, momentum, and energy exchanges of both the liquid and gas phases between the neighboring core assemblies. Graphics were also developed for the Instructor Station for this project under WSC’s proprietary 3KEYMASTERTM platform to facilitate design and operational decision making.

42 ENGINEERING↗

Preliminary Design of Nuclear Reactor Heat Delivery Systems: Integration with Reference Oil Refinery, Methanol Synthesis, and Hydrogen Production

The Department of Energy’s (DOE) Integrated Energy Systems (IES) program is generating comprehensive analyses validating the opportunity for using nuclear energy in a variety of applications including future clean grids, providing heat for direct use, and providing heat to help reduce emissions in chemical commodities. This work focuses on the preliminary designs of thermal delivery systems that can integrate heat produced from a nuclear core to industrial processes. The key research question that needs to be answered is: what is the prospective method for integrating nuclear generated heat energy into non-electric applications that can facilitate combined heat and power operations by advanced nuclear reactor systems? This research is a composition of case studies showing preliminary conceptual designs for thermal delivery systems integrating advanced nuclear systems with a few industrial systems including high temperature steam electrolysis, a reference oil refinery, and potential future methanol systems that supplant some natural gas use with nuclear energy. Piping and instrumentation diagrams have been developed to show the conceptual integration of nuclear systems with representative industrial systems. Different features of the configurations are dependent on the specific integration requirements including energy source conditions, demand quantity, and require energy application conditions. Design concepts are validated using thermodynamic balance calculations to verify system performance including calculating system losses during transport. Key components: pumps and compressors, heat exchangers, and network piping are reported with key design information and sizing.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Technological evolution of large-scale blue hydrogen production toward the U.S. Hydrogen Energy Earthshot

Hydrogen potentially has a crucial role in the U.S. transition to a net-zero emissions economy. Learning from large-scale hydrogen projects will boost technological evolution and innovation toward the U.S. Hydrogen Energy Earthshot. We apply experience curves to estimate the evolving costs of blue hydrogen production and to further examine the economic effect on technological evolution of the Inflation Reduction Act’s tax credits for carbon sequestration and clean hydrogen. Learning-by-doing alone can decrease the production cost of blue hydrogen. Without tax incentives, however, it is hard for blue hydrogen production to reach the cost target of $\$1$/kg H 2 . Here we show that the breakeven cumulative production capacity required for gas-based blue hydrogen to reach the $\$1$/kg H 2 target highly depends on tax credit, natural gas price, inflation rate, and learning rates. We make recommendations for hydrogen hub development and for accelerating technological progress toward the Hydrogen Energy Earthshot.

08 HYDROGEN↗

Boosting the performance of reversible solid oxide electrochemical cells with a novel hybrid oxygen electrode, Pr 1.39 Ba 0.14 Sr 0.53 Co 1.48 Fe 0.76 O 6- δ -Ba 0.66 Sr 0.34 CoO 3- δ

Solid oxide electrochemical cells (SOECs) stand out as a highly promising clean energy technology that offers several benefits, showing significant potential to play a pivotal role in the transition towards a sustainable and low-carbon energy future. SOECs can efficiently convert the chemical energy stored in fuels to electricity in fuel cell mode, and produce various chemicals from abundant feedstocks (e.g., CO 2 , H 2 O) and intermittent solar/wind-based renewable electricity. Despite extensive efforts that have been devoted to designing novel materials and optimizing SOEC manufacturing processes, aiming to achieve enhanced energy efficiency, the current SOECs still suffer from poor performance, which is mainly due to the sluggish oxygen reduction reaction (ORR) and oxygen evolution reaction (OER) kinetics. To address this challenge, in this work, we have successfully designed an in situ formed hybrid oxygen electrode material (Pr 1.39 Ba 0.14 Sr 0.53 Co 1.48 Fe 0.76 O 6- δ -Ba 0.66 Sr 0.34 CoO 3- δ ), which significantly improves the surface oxygen exchange coefficient and bulk oxygen-ion diffusion coefficient, enhancing the OER and ORR electrocatalytic activities. Further, the SOECs equipped with this newly developed oxygen electrode achieved exceptional performance for power generation using both hydrogen and propane as the fuels. At 750 °C, a peak power density of 2.4 W cm -2 was obtained with H 2 as the fuel. Additionally, the SOECs attain unprecedented performance in steam electrolysis mode. A current density of 4.4 A cm -2 was achieved at 1.3 V and 750 °C, which represents the highest performance among all yttria-stabilized zirconia (YSZ) electrolyte-based SOECs. The SOECs also deliver remarkable stability during the accelerated stability testing, highlighting the great potential of Pr 1.39 Ba 0.14 Sr 0.53 Co 1.48 Fe 0.76 O 6- δ -Ba 0.66 Sr 0.34 CoO 3- δ as a high-performance oxygen electrode for next generation SOECs.

08 HYDROGEN↗

Isotherm Modeling and Techno-Economic Analysis of Contactor Technologies for New Tetraamine-Appended MOF for NGCC Applications

Recently, a family of tetraamine-functionalized metal-organic frameworks (MOF) has been reported as promising sorbent materials for capturing CO2 from flue gas conditions relevant to natural gas combined cycle (NGCC) applications. The main advantages of these materials are their two-step cooperative CO2 adsorption, which gives rise to unusual two step-shaped CO2 adsorption profiles and their high thermal stability. This work presents the modelling of the two-transition isotherm of the tetraamine-appended MOF, N,N'-bis(3-aminopropyl)-1,4-diaminobutane (3-4-3)-appended Mg2(dobpdc), and the techno-economic analysis (TEA) of carbon capture processes utilizing this sorbent. Due to the unusual isotherm shapes of the experimental CO2 adsorption data for tetraamine-appended Mg2(dobpdc) and the strong nonlinearity of CO2 loading with respect to temperature and pressure, we tested two different models which use logistic functions for representing the different isotherm behaviors in the different pressure ranges. The first model uses the quadratic isotherm model in the low-pressure region, the Langmuir isotherm model in the middle pressure range, and the dual site Langmuir isotherm model in the high-pressure range. To model the transition between regions we used the arctangent functions independent of temperature and the thermal effect was accounted by using the Clausius-Clapeyron relation]. The second model is an extension of the weighted dual-site Langmuir isotherm model presented by Hughes et al.. In this extended model, the dual-site Langmuir isotherm is employed in the three transition regions, using temperature-dependent logistic functions to activate or deactivate the isotherm model in the low, middle, and high-pressure ranges. Both models fit the experimental data quite well with root mean squared errors (RMSE’s) of 0.41 and 0.17 for model 1 and model 2, respectively. Since model 2 resulted in a lower RMSE, it was leveraged for the development of the gas/solid contactor models used by the TEA. Specifically, two different contactor models, an axial-flow fixed bed and moving bed contactor, were developed as part of this work. These models are dynamic, pressure-driven, and consist of mass, energy, and momentum conservation equations. A kinetic model was also developed by performing parameter estimation using experimental fixed bed breakthrough data. These models are then used to simulate CO2 capture processes from the flue gas generated from a ~600 gross MW NGCC power plant. A cost model was developed which considers the capital cost of the reactors and the significant operating costs such as steam and electricity. Using NETL’s Framework for the Optimization and Quantification of Uncertainty of Uncertainty and Surrogates tool (FOQUS), which has the capability of linking models built using numerous modelling platforms with derivative-free optimization solvers, a techno-economic optimization of the carbon capture processes was performed which minimizes the cost of capture.

Caballero, Daison↗

Comparative performance of solar thermal power generation concepts

A performance comparison is made between the central receiver system (power tower) and a distributed system using either dishes or troughs and lines to transport fluids to the power station. These systems were analyzed at a rated capacity of 30 MW of thermal energy delivered in the form of superheated steam at 538 C (1000 F) and 68 atm (1000 psia), using consistent weather data, collector surface waviness, pointing error, and electric conversion efficiency. The comparisons include technical considerations for component requirements, land utilization, and annual thermal energy collection rates. The relative merits of different representative systems are dependent upon the overall conversion as expressed in the form of performance factors in this paper. These factors are essentially indices of the relative performance effectiveness for different concepts based upon unit collector area. These performance factors enable further economic tradeoff studies of systems to be made by comparing them with projected production costs for these systems.

Wen, L.↗

Design and Experimental Demonstration of an Additive Manufactured Smart Oxy-Methane Burner for High Pressure and Supercritical Combustion

Pressurized oxy combustion-based systems can improve efficiency by recovering latent heat of the steam in the Flue Gas and achieving 90% CO2 capture. In addition, the novel Directly Heated Supercritical Carbon Dioxide (DH-SCO2) power cycles can achieve high thermal efficiencies and provide nearly full carbon capture. Additionally, due to the reduction of flue gas at higher pressure, smaller system size and capital cost reductions are also possible. Recent thermodynamic analysis of the DH-SCO2 cycle performed by the UTEP research team shows that combustion conditions in the vicinity of 300 bar pressure and 1000-1400 K temperature allow for relatively high system efficiencies while operating within the limit of available combustor materials. However, the realization of a directly heated supercritical power cycle requires combustion systems to operate in supercritical conditions and at temperature far below the blowout limit of conventional flames (above 1500 K). The thermodynamic properties along with the combustion properties and kinetics are unexplored at such conditions. Additionally, the interaction of the supercritical environment with energy components is also unknown. High-pressure combustion tests are performed using a smart burner at some intermediate pressure ranges (<20 bar) to help minimize these knowledge gaps. The knowledge obtained from the high-pressure test will assist in understanding the combustion chamber pressurization mechanism, ignition and flame behavior at the elevated pressure. The obtained data will act as a systematic first step in testing at higher pressures of 100 and 300 bar pressures.The primary purpose of this Dissertation is to demonstrate the operability of a low NOx smart burner for oxy-methane combustion at high pressure (< 20 bar) and scalable up to supercritical conditions. A shear co-axial smart burner is designed with a real-time temperature monitoring capability to understand the burner face interaction at high-pressure conditions. In addition, the burner has four independent injection ports to allow the independent injection of fuel and dilution gases in the combustor. The maximum operating capability of the burner is 575 kWth. The burner was fabricated using a Laser Powder Bed Fusion process with Nickel Alloy 718. A powder removal technology was invented comprising ultrasonic vibration, liquid nitrogen exposure and media blasting to remove powders from internal channels of the burner. The burner operability tests are performed in the high-pressure combustor and the swirl combustor. The high-pressure combustor was used to investigate the burner operability and thermal soak back at different pressurized conditions. The experimental tests in high-pressure combustor up to 275 kWth input resulted in 16.5 bar chamber pressure and 198°C thermal soaks back to the burner. The burner was capable of providing the required thermal input within a 3% deviation range. In addition, soot formation occurred at high-pressure tests. The swirl combustor was used to observe the flame stability of the burner. Flame lift-off was observed for jet velocities above 450 m/s. Additionally, lift-off decreased for low co-flow velocities. CO2 dilution experiments showed increased flame instabilities for all conditions above 50% dilution ratios. At lower thermal inputs, partial flame blow-offs occurred for dilution ratios above 50%. All conditions significantly reduced the flame temperature and increased the flame lift-off height. Finally, a 2nd generation AM smart burner was designed using the knowledge from the 1st generation burner experiments. The 2nd generation burner incorporated two sets of swirlers with 0.9 swirl no. A cooling system was also designed for long-duration tests at higher pressures. The thermal input and division of the burner's power are kept the same as the 1st generation burner. The burner is to be fabricated using nickel-alloy 718 for high-pressure handling capability. The design can sustain at high-pressure conditions up to 100 bar.

Islam, Md Nawshad Arslan↗

Experimental performance of ejector heat pump operating in the sub-critical mode

Ejector heat pump (EHP) is an efficient-energy technology with a promising potential to replace the vapor compression cycle in heating and cooling applications. It can be powered by low-grade waste heat and uses environmentally friendly working fluids. EHP has also become a viable solution in research seeking cooling applications. However, little attention has been paid to using EHP for heating purposes. In order to investigate this, a steam EHP for domestic water heating was designed and built. The coefficient of performance (COP) is evaluated at various operating and design conditions in sub-critical operational modes to achieve higher condensation temperatures. Two primary nozzles with a throat diameter of 1.5 mm and 2.0 mm were investigated. The primary nozzle is movable along the ejector’s axis, allowing investigation of its positional effects on the EHP’s COP. Further, experimental measurements revealed that using a smaller throat diameter results in a high COP and low back pressure. The EHP COP and back pressure increase when the LTE temperature increases. Using a throat diameter of 1.5 mm, the EHP COP increases as the nozzle exit position (NXP) becomes closer to the constant area section. A COP of 2.42 and a back pressure of 4.28 kPa are achieved at a high-temperature evaporator (HTE) temperature of 130 °C and a low-temperature evaporator (LTE) temperature of 30 °C using a primary nozzle with 1.5 mm.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cooperative carbon capture and steam regeneration with tetraamine-appended metal–organic frameworks

Natural gas has become the dominant source of electricity in the United States, and technologies capable of efficiently removing carbon dioxide (CO 2 ) from the flue emissions of natural gas–fired power plants could reduce their carbon intensity. However, given the low partial pressure of CO 2 in the flue stream, separation of CO 2 is particularly challenging. Taking inspiration from the crystal structures of diamine-appended metal–organic frameworks exhibiting two-step cooperative CO 2 adsorption, we report a family of robust tetraamine-functionalized frameworks that retain cooperativity, leading to the potential for exceptional efficiency in capturing CO 2 under the extreme conditions relevant to natural gas flue emissions. The ordered, multimetal coordination of the tetraamines imparts the materials with extraordinary stability to adsorption-desorption cycling with simulated humid flue gas and enables regeneration using low-temperature steam in lieu of costly pressure or temperature swings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The helical screw expander evaluation project

A positive-displacement helical-screw expander of the Lysholm type has been adapted for geothermal service and successfully demonstrated in a 50 kW prototype power system. Evaluation of the expander by tests of a new model in a 1 MW power system under wellhead conditions in selected liquid-dominated geothermal fields is proposed. The objectives are to determine the performance characteristics of the expander and power system over a broad range of operating conditions and also to examine the concept of wellhead power plants. Throttling and fractionation of the fluids from the test wells is planned to simulate a wide range of wellhead pressures and steam fractions. Variation in the expander exhaust pressure is also planned. The investigation will include expander efficiency, corrosion, erosion, scale formation and control, and endurance testing. Interaction studies with the wells and an electric grid are also proposed.

Mckay, R. A.↗

Advanced Coal-Based Power Generations

Advanced power-generation systems using coal-derived fuels are evaluated in two-volume report. Report considers fuel cells, combined gas- and steam-turbine cycles, and magnetohydrodynamic (MHD) energy conversion. Presents technological status of each type of system and analyzes performance of each operating on medium-Btu fuel gas, either delivered via pipeline to powerplant or generated by coal-gasification process at plantsite.

Robson, F. L.↗

Microwave powered sterile access port

A device and method for elimination of contamination during transfer of materials either into or from bioreactors, food containers, or other microbially vulnerable systems. Using microwave power, thermal sterilizations of mating fixtures are achieved simply, reliably, and quickly by the volatilization of small quantities of water to produce superheated steam which contacts all exposed surfaces.

Sauer, Richard L.↗

Solar heated fluidized bed gasification system

A solar-powered fluidized bed gasification system for gasifying carbonaceous material is presented. The system includes a solar gasifier which is heated by fluidizing gas and steam. Energy to heat the gas and steam is supplied by a high heat capacity refractory honeycomb which surrounds the fluid bed reactor zone. The high heat capacity refractory honeycomb is heated by solar energy focused on the honeycomb by solar concentrator through solar window. The fluid bed reaction zone is also heated directly and uniformly by thermal contact of the high heat capacity ceramic honeycomb with the walls of the fluidized bed reactor. Provisions are also made for recovering and recycling catalysts used in the gasification process. Back-up furnace is provided for start-up procedures and for supplying heat to the fluid bed reaction zone when adequate supplies of solar energy are not available.

Qader, S. A.↗

Conceptual Design Study of a Thermal Energy Storage System Using Granular Solids for Coal-fired Boilers

<span style="font-size: 12pt;">Presentation for the 2020 International Pittsburgh Coal Conference held virtually from September 8-11, 2020.</span><span style="font-size: 12pt;">Abstract: As electricity from various renewable energy sources is increasingly supplied to the power grid, the grid’s stability will be challenged. Proposed grid-stability solutions will need to address variability of sources, such as solar and wind energy, in order to alleviate problems such as overgeneration and ramping. In regions where increases in solar energy are prominent, such as California, the net power demand curve often referred to as “the Duck Curve,” has caused problems for energy dispatchers, due to over-generation and fast ramping demands. In this project, we investigated a conceptual design for a Thermal Energy Storage System (TESS) integrated into a coal-fired power plant to support grid-scale storage. Implementing a TESS into power plants can allow for an increase in renewable sources, increase grid resilience, and allow conventional coal-fired plants to operate more efficiently. For this project, a TESS using granular solids as the energy-storage media is integrated into a conventional coal-fired power plant. The purpose of the TESS is to store energy from the flue gas during low demand periods and transfer the energy to steam during peak demand periods. The storage allows the stabilization of combustion and related boiler components at low loads and provides the opportunity to avoid some shutdowns. This study uses thermodynamic properties of several candidate thermal storage materials to estimate the size of storage system required for several operating scenarios. </span>

Huckaby, E. David↗

Environmental Evaluation of Gas Switching Reforming for Low Carbon Hydrogen: A Power-to-X Study

Gas Switching Reforming for hydrogen production (GSR-H2) offers a promising pathway for producing low-carbon hydrogen at scale, with significant implications for Power-to-X (PtX) systems that rely on clean hydrogen as a feedstock for synthetic fuels and chemicals. GSR-H2 integrates inherent carbon capture and thermal self-sufficiency, positioning it as an efficient alternative to conventional steam methane reforming (SMR), proton exchange membrane (PEM) electrolysis, and chemical looping reforming (CLR). Unlike SMR, GSR-H2 avoids external natural gas combustion by leveraging exothermic redox cycles to generate process steam and recover electricity internally. Its innovative reactor design consolidates all reforming stages within a single reactor cluster, eliminating the need for solid circulation found in CLR, thereby reducing capital costs and improving system reliability and scalability. This presentation describes the first environmental life cycle assessment (LCA) of GSR-H2, evaluating its environmental performance across U.S. grid and renewable energy scenarios. In a renewables-powered configuration, GSR-H2 achieves a global warming potential (GWP) of 2.77 kg CO2 equivalent per kg H2, substantially lower than SMR (10.4 kg) and competitive with PEM electrolysis (1.85 kg) and CLR (1.84 kg). Results across additional impact categories, including air quality and water use, support GSR-H2’s role as a complementary hydrogen source in PtX applications. Its reduced environmental burden, thermal integration, and simplified scale-up potential make GSR-H2 a viable contributor to net-zero PtX systems, particularly where renewable energy is abundant and electricity-intensive hydrogen production faces economic or infrastructure constraints.

03 NATURAL GAS↗

Green-Field Geothermal/Solar Designs (Cooperative Research and Development Final Report)

Geothermal power (GEO) and concentrating solar power (CSP) can be integrated to obtain the best aspects of both systems. The green-field design will utilize the full potential of the higher-temperature CSP sector by having a topping solar steam turbine and a bottoming geothermal cycle. In the proposed hybrid cycle, geothermal energy can be converted into electricity at a higher cycle efficiency because of the high-temperature topping cycle during the daytime. CSP benefits from lower-cost solar collectors, a less expensive topping turbine, and virtual elimination of the heat rejection system cost. The green-field case study will be focused on a geothermal resource site which will deliver the 160 - 220 °C pressurized brine at the inlet of power block. While the case study will look at a single case study, the tools to be developed as part of the project will be available to model annual performance of GEO/CSP hybrids for new greenfield projects (may also be applied to certain types of brown-field retrofits). The evaluation tools will also calculate important economic parameters such as the levelized cost of energy (LCOE) and the internal rate of return (IRR).

14 SOLAR ENERGY↗