Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectrum monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Test-section noise of the Ames 7 by 10-foot wind tunnel no. 1

An investigation was made of the test-section noise levels at various wind speeds in the Ames 7- by 10-Foot Wind Tunnel No. 1. No model was in the test section. Results showed that aerodynamic noise from various struts used to monitor flow conditions in the test section dominated the wind-tunnel background noise over much of the frequency spectrum. A tapered microphone stand with a thin trailing edge generated less noise than did a constant-chord strut with a blunt trailing edge. Noise from small holes in the test-section walls was insignificant.

Soderman, P. T.↗

Wave motions in the upper atmospheric sodium layer observed with a lidar technique

Since the middle of 1980, the vertical profile of the atmospheric sodium layer was observed with a tunable laser radar at Mt. Zao Observatory in northern Japan. The principal characteristics of the lidar system are summarized. The output wavelength is continuously monitored by using a sodium resonance cell, a spectrometer, and a Fabry-Perot interferometer provided with the reference spectrum of the sodium lamp. Owing to the strict temperature control of the filters, the tuning is sufficiently stable throughout the night. The calibration of the absolute sodium density was carried out by adopting the method established by previous works.

Kamiyama, H.↗

Assessment of the Short-Term Radiometric Stability between Terra MODIS and Landsat 7 ETM+ Sensors

The Landsat 7 (L7) Enhanced Thematic Mapper (ETM+) sensor was launched on April 15th, 1999 and has been in operation for over nine years. It has six reflective solar spectral bands located in the visible and shortwave infrared part of the electromagnetic spectrum (0.5 - 2.5 micron) at a spatial resolution of 30 m. The on-board calibrators are used to monitor the on-orbit sensor system changes. The ETM+ performs solar calibrations using on-board Full Aperture Solar Calibrator (FASC) and the Partial Aperture Solar Calibrator (PASC). The Internal Calibrator Lamp (IC) lamps, a blackbody and shutter optics constitute the on-orbit calibration mechanism for ETM+. On 31 May 2003, a malfunction of the scan-line corrector (SLC) mirror assembly resulted in the loss of approximately 22% of the normal scene area. The missing data affects most of the image with scan gaps varying in width from one pixel or less near the centre of the image to 14 pixels along the east and west edges of the image, creating a wedge-shaped pattern. However, the SLC failure has no impacts on the radiometric performance of the valid pixels. On December 18, 1999, the Moderate Resolution Imaging Spectroradiometer (MODIS) Proto-Flight Model (PFM) was launched on-board the NASA's EOS Terra spacecraft. Terra MODIS has 36 spectral bands with wavelengths ranging from 0.41 to 14.5 micron and collects data over a wide field of view angle (+/-55 deg) at three nadir spatial resolutions of 250 m, 500 in 1 km for bands 1 to 2, 3 to 7, and 8 to 36, respectively. It has 20 reflective solar bands (RSB) with spectral wavelengths from 0.41 to 2.1 micron. The RSB radiometric calibration is performed by using on-board solar diffuser (SD), solar diffuser stability monitor (SDSM), space-view (SV), and spectro-radiometric calibration assembly (SRCA). Through the SV port, periodic lunar observations are used to track radiometric response changes at different angles of incidence (AOI) of the scan mirror. As a part of the AM Constellation satellites, Terra MODIS flies approximately 30 minutes behind L7 ETM+ in the same orbit. The orbit of L7 is repetitive, circular, sunsynchronous, and near polar at a nominal altitude of 705 km (438 miles) at the Equator. The spacecraft crosses the Equator from north to south on a descending node between 10:00 AM and 10:15 AM. Circling the Earth at 7.5 km/sec, each orbit takes nearly 99 minutes. The spacecraft completes just over 14 orbits per day, covering the entire Earth between 81 degrees north and south latitude every 16 days. The longest continuous imaging swath that L7 sensor can collect is for a 14-minute subinterval contact period which is equivalent to 35 full WRS-2 scenes. On the other hand, Terra can provide the entire corresponding orbit with wider swath at any given ETM+ collection without contact time limitation. There are six spectral matching band pairs between MODIS (bands 3, 4, 1, 2, 6, 7) and ETM+ (bands 1, 2, 3, 4, 5, 7) sensor. MODIS has narrower spectral responses than ETM+ in all the bands. A short-term radiometric stability was evaluated using continuous ETM+ scenes within the contact period and the corresponding half orbit MODIS scenes. The near simultaneous earth observations (SNO) were limited by the smaller swath size of ETM+ (187 km) as compared to MODIS (2330 km). Two sets of continuous granules for MODIS and ETM+ were selected and mosaiced based on pixel geolocation information for non cloudy pixels over the North American continent. The Top-of- Atmosphere (TOA) reflectances were computed for the spectrally matching bands between ETM+ and MODIS over the regions of interest (ROI). The matching pixel pairs were aggregated from a finer to a coarser pixel resolution and the TOA reflectance values covering a wide dynamic range of the sensors were compared and analyzed. Considering the uncertainties of the absolute calibration of the both sensors, radiometric stability was verified for the band pairs. The Railroad Valley Playa, Nada (RVPN) was included in the path of this continuous orbit, which served as a verification point between the shortterm and the long-term trending results from previous studies. This work focuses on monitoring the short-term on-orbit stability of MODIS and the ETM+ RSB. It also provides an assessment of the absolute calibration differences between the two sensors over their wide dynamic ranges.

Choi, Taeyoung↗

High Resolution ECG for Evaluation of Heart Function During Exposure to Subacute Hypobaric Hypoxia

High altitude climbing presents a wide spectrum of health risks, including exposure to hypobaric hypoxia. Risks are also typically exacerbated by the difficulty in appropriately monitoring for early signs of organ dysfunction in remote areas. We investigated whether high resolution advanced ECG analysis might be helpful as a non-invasive and easy-to-use tool (e.g., instead of Doppler echocardiography) for evaluating early signs of heart overload in hypobaric hypoxia. Nine non-acclimatized healthy trained alpine rescuers (age 43.7 plus or minus 7.3 years) climbed in four days to the altitude of 4,200 m on Mount Ararat. Five-minute high-resolution 12-lead electrocardiograms (ECGs) were recorded (Cardiosoft) in each subject at rest in the supine position on different days but at the same time of day at four different altitudes: 400 m (reference altitude), 1,700 m, 3,200 m and 4,200 m. Changes in conventional and advanced resting ECG parameters, including in beat-to-beat QT and RR variability, waveform complexity, signal-averaged, high-frequency and spatial/spatiotemporal ECG was estimated by calculation of the regression coefficients in independent linear regression models. A p-value of less than 0.05 was adopted as statistically significant. As expected, the RR interval and its variability both decreased with increasing altitude, with trends k = -96 ms/1000 m with p = 0.000 and k = -9 ms/1000 m with p = 0.001, respectively. Significant changes were found in P-wave amplitude, which nearly doubled from the lowest to the highest altitude (k = 41.6 microvolt/1000 m with p = 0.000), and nearly significant changes in P-wave duration (k = 2.9 ms/1000 m with p = 0.059). Changes were less significant or non-significant in other studied parameters including those of waveform complexity, signal-averaged, high-frequency and spatial/spatiotemporal ECG. High resolution ECG analysis, particularly of the P wave, shows promise as a tool for monitoring early changes in heart function due to exposure to high altitude.

Zupet, Petra↗

Jet Propulsion Laboratory: Annual Report 2004

Once or twice in an age, a year comes along that the historians proclaim as an Annus Mirabilis - a year of wonders. For the Jet Propulsion Laboratory, 2004 was just that sort of time. From beginning to end, it was a nonstop experience of wondrous events in space. Imagine that two robot rovers embark on cross-country rambles across Mars, scrutinizing rocks for signs of past water on the now-arid world. A flagship spacecraft brakes into orbit at Saturn to begin longterm surveillance of the ringed world, preparing to drop a sophisticated probe to the surface of its haze-shrouded largest moon. Another craft makes the closest-ever pass by the nucleus of a comet, collecting sample particles as it goes. Two new space telescopes peer into the depths of the universe far beyond our solar system, viewing stars, nebulas and galaxies in invisible light beyond the spectrum our eyes can see. A pair of instruments is lofted on a NASA Earth-orbiting satellite to monitor air quality and the protective layer of ozone blanketing our home planet. A small probe brings samples of the solar wind to Earth for in-depth study. While JPL was absorbed with all of these ventures on other worlds, NASA and the White House unveiled an ambitious new plan of space exploration. The Vision for Space Exploration announced in January foresees a program of robotic and astronaut missions leading to a human return to the Moon by 2020, and eventual crewed expeditions to Mars. The vision also calls for more robotic missions to the moons of the outer planets; spaceborne observatories that will search for Earth-like planets around other stars and explore the formation and evolution of the universe; and continued study of our home planet. In order to accomplish all of this, NASA must perfect many as-yet-uninvented technologies and space transportation capabilities. JPL has a great deal to bring to this vision. Robotic exploration of Mars will lead the way for missions that will carry women and men to the red planet. Our engineers and scientists are formulating spacecraft that could use nuclear power to enable exploration missions of the future. And even now we are designing formations of space telescopes that will capture family portraits of the planets around neighboring stars. Those are only some of the ways that the Laboratory is contributing to NASA's broader goals. During 2004, JPL made a distinctive contribution to agencywide initiatives in areas such as safety, NASA transformation, the agency's Internet portal and NASA's Explorer Schools programs. Years like 2004 pose a special challenge for us. It would be easy to say that this was a once-in-a-decade high point of mission activities, but I believe that this would miss an opportunity. We are fortunate to have many space projects in the works that have the promise of being just as exhilarating as the great mission successes that we celebrated this year. The challenge and opportunity for us now is to make every year like this one.

National Aeronautics and Space Administration (NAS↗

Identification of mixed sources with an organic scintillator-based radiation portal monitor

We have developed radionuclide identification algorithms for radiation portal monitor applications. One algorithm uses a spectral angle mapper to match the power spectral density of modified cumulative distribution functions of measured pulse height distributions to reference spectra, while the others rely on the decomposition of the observed spectrum as a linear mixture of known radionuclide spectra. Three algorithms were then tested for their ability to perform on-the-fly radionuclide identification on datasets acquired with a liquid organic scintillator-based pedestrian radiation portal monitor on moving special nuclear material and industrial radiological sources, as well as common medical isotopes. We quantified and compared the relative efficacies of the algorithms considered using F-score analysis. Measured radiation sources included 51 g of highly enriched uranium, 6.6 g of weapons grade plutonium, 241 Am, 133 Ba, 57 Co and 137 Cs sources with activities of several hundred kBq, as well as 260 kBq liquid solution samples of the medical isotopes 99m Tc, 111 In, 67 Ga, 123 I, 131 I, and 201 Tl. We achieved 100% positive identification, for three-second measurements of single sources moving at a source-transit speed of 1.2 m/s. For mixed sources with strongest and weakest sources having no more than a 5:1 ratio of detected counts, encouraging positive identification results were achieved with the un-mixing algorithms. Current radiation portal monitor designs suffer from a high incidence rate of nuisance radiation alarms caused in radiation portal monitor primary screenings by recent nuclear medicine patients and cargo containing large amounts of naturally occurring radioactive materials. Integrating reliable on-the-fly radionuclide identification into the radiation portal monitors could lower the number of nuisance alarms requiring time-consuming secondary inspections.

47 OTHER INSTRUMENTATION↗

Automated Weight-Window Generation for Threat Detection Applications Using ADVANTG

Deterministic transport codes have been used for some time to generate weight-window parameters that can improve the efficiency of Monte Carlo simulations. As the use of this hybrid computational technique is becoming more widespread, the scope of applications in which it is being applied is expanding. An active source of new applications is the field of homeland security--particularly the detection of nuclear material threats. For these problems, automated hybrid methods offer an efficient alternative to trial-and-error variance reduction techniques (e.g., geometry splitting or the stochastic weight window generator). The ADVANTG code has been developed to automate the generation of weight-window parameters for MCNP using the Consistent Adjoint Driven Importance Sampling method and employs the TORT or Denovo 3-D discrete ordinates codes to generate importance maps. In this paper, we describe the application of ADVANTG to a set of threat-detection simulations. We present numerical results for an 'active-interrogation' problem in which a standard cargo container is irradiated by a deuterium-tritium fusion neutron generator. We also present results for two passive detection problems in which a cargo container holding a shielded neutron or gamma source is placed near a portal monitor. For the passive detection problems, ADVANTG obtains an O(10{sup 4}) speedup and, for a detailed gamma spectrum tally, an average O(10{sup 2}) speedup relative to implicit-capture-only simulations, including the deterministic calculation time. For the active-interrogation problem, an O(10{sup 4}) speedup is obtained when compared to a simulation with angular source biasing and crude geometry splitting.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electron line shape and transmission function of the KATRIN monitor spectrometer

Knowledge of the neutrino mass is of particular interest in modern neutrino physics. Besides the neutrinoless double beta decay and cosmological observation information about the neutrino mass is obtained from single beta decay by observing the shape of the electron spectrum near the endpoint. The KATRIN β decay experiment aims to push the limit on the effective electron antineutrino mass down to 0.2 eV/c{sup 2}. To reach this sensitivity several systematic effects have to be under control. One of them is the fluctuations of the absolute energy scale, which therefore has to be continuously monitored at very high precision. This paper shortly describes KATRIN, the technique for continuous monitoring of the absolute energy scale and recent improvements in analysis of the monitoring data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Area Monitoring for Detection of Leaks and/or Flames

A solution for monitoring an area for the presence of a flame and/or a leak, such as from a pressurized fluid, is provided. An imaging device can be used that acquires image data based on electromagnetic radiation having wavelengths only corresponding to at least one region of the electromagnetic spectrum in which electromagnetic radiation from an ambient light source is less than the electromagnetic radiation emitted by at least one type of flame for which the presence within the area is being monitored. An acoustic device can be used that is configured to acquire acoustic data for the area and enhance acoustic signals in a range of frequencies corresponding to a leak of a pressurized fluid present in the area.

Mian, Zahid F.↗

Area Monitoring for Detection of Leaks And/Or Flames

A solution for monitoring an area for the presence of a flame and/or a leak, such as from a pressurized fluid, is provided. An imaging device can be used that acquires image data based on electromagnetic radiation having wavelengths only corresponding to at least one region of the electromagnetic spectrum in which electromagnetic radiation from an ambient light source is less than the electromagnetic radiation emitted by at least one type of flame for which the presence within the area is being monitored. An acoustic device can be used that is configured to acquire acoustic data for the area and enhance acoustic signals in a range of frequencies corresponding to a leak of a pressurized fluid present in the area.

Mian, Zahid F.↗

Measuring Saturn's Electron Beam Energy Spectrum using Webb's Wedges

It is very difficult to measure the voltage of the load on the Saturn accelerator. Time-resolved measurements such as vacuum voltmeters and V-dot monitors are impractical at best and completely change the pulsed power behavior at the load at worst. We would like to know the load voltage of the machine so that we could correctly model the radiation transport and tune our x-ray unfold methodology and circuit simulations of the accelerator. Step wedges have been used for decades as a tool to measure the end - point energies of high energy particle beams. Typically, the technique is used for multi-megavolt accelerators, but we have adapted it to Saturn's modest <2 MV end-point energy and modified the standard bremsstrahlung x-ray source to extract the electron beam without changing the physics of the load region. We found clear evidence of high energy electrons >2 MV. We also attempted to unfold an electron energy spectrum using a machine learning algorithm and while these results come with large uncertainties, they qualitatively agree with PIC simulation results.

43 PARTICLE ACCELERATORS↗

Solid-State Spectral Light Source System

A solid-state light source combines an array of light-emitting diodes (LEDs) with advanced electronic control and stabilization over both the spectrum and overall level of the light output. The use of LEDs provides efficient operation over a wide range of wavelengths and power levels, while electronic control permits extremely stable output and dynamic control over the output. In this innovation, LEDs are used instead of incandescent bulbs. Optical feedback and digital control are used to monitor and regulate the output of each LED. Because individual LEDs generate light within narrower ranges of wavelengths than incandescent bulbs, multiple LEDs are combined to provide a broad, continuous spectrum, or to produce light within discrete wavebands that are suitable for specific radiometric sensors.

Maffione, Robert↗

Superiority of terahertz over infrared transmission through bandages and burn wound ointments

Terahertz electromagnetic waves have long been proposed to be ideal for spectroscopy and imaging through non-polar dielectric materials that contain no water. Terahertz radiation may thus be useful for monitoring burn and wound injury recovery, as common care treatments involve application of both a clinical dressing and topical ointment. Here, we investigate the optical properties of typical care treatments in the millimeter wave (150–300 GHz), terahertz (0.3–3 THz), and infrared (14.5–0.67 μm) ranges of the electromagnetic spectrum. We find that THz radiation realizes low absorption coefficients and high levels of transmission compared to infrared wavelengths, which were strongly attenuated. Terahertz imaging can enable safe, non-ionizing, noninvasive monitoring of the healing process directly through clinical dressings and recovery ointments, minimizing the frequency of dressing changes and thus increasing the rate of the healing process.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development and testing of a fission-like neutron field for dosimetry and instrument calibrations based on deuterium-tritium generator

For nearly five decades 252 Cf sources have been used for testing and calibration over a wide range of neutron detection devices used for nuclear safety and radiation protection. However, the vastly increased cost of 252 Cf sources, its short half-life, and concerns about future shortage have prompted nuclear facilities and radiological calibration laboratories that rely on high-intensity neutron sources to seek alternatives. There appear to be no other radionuclide neutron sources that would match “like-to-like” 252 Cf performance characteristics. Alternatives of producing a fission-like neutron spectrum based on commercially available deuterium-tritium (D-T) generators, and without any fissionable materials or beryllium, have been explored. This paper describes efforts of designing the spectrum shaping assembly, its construction and installation. The produced neutron field was evaluated both from the perspective of the neutron fluence spectrum and the resulting dosimetric outcome. Finally, it was tested for practical application by examining response of various health physics instruments and personal monitoring devices in comparison to the response of those devices when exposed to 252 Cf. In conclusion, the response of survey-type instruments tested within the prototype, surrogate fission, reference field are acceptably close to their response in the targeted 252 Cf field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Review—Micro-Fuel Cell Principal Biosensors for Monitoring Transdermal Volatile Organic Compounds in Humans

Knowledge of transduction mechanisms in biosensing applications paves the way for ultrasensitive and dynamic detection in living systems. Real-world biosensing applications where ultra-sensitivity and dynamic detection are paramount include monitoring the anesthetic agent concentration during surgery; the slightest variation in concentration can potentially result in a life-threatening overdose or, on the other end of the spectrum, the patient’s awareness during the procedure. We review the benefits and functions of the transcutaneous biosensor device compared with other current technology and discuss the sensor’s capability to accurately measure volatile anesthetic gas concentration in blood using fuel cell technology. We review fundamental concepts of fuel-cell technology for wearable bio-sensing applications. The fuel cell sensor can also continuously monitor other volatile organic compounds making it versatile with numerous potential applications.

42 ENGINEERING↗

A COMPREHENSIVE ANALYSIS OF FERMI GAMMA-RAY BURST DATA. II. E{sub p} EVOLUTION PATTERNS AND IMPLICATIONS FOR THE OBSERVED SPECTRUM-LUMINOSITY RELATIONS

We present a time-resolved spectral analysis of 51 long and 11 short bright gamma-ray bursts (GRBs) observed with the Fermi/Gamma-Ray Burst Monitor, paying special attention to E{sub p} evolution within each burst. Among eight single-pulse long GRBs, five show an evolution from hard to soft, while three show intensity tracking. The multi-pulse long GRBs have more complicated patterns. Statistically, the hard-to-soft evolution pulses tend to be more asymmetric than the intensity-tracking ones, with a steeper rising wing than the falling wing. Short GRBs have E{sub p} tracking intensity exclusively with the 16 ms time-resolution analysis. We performed a simulation analysis and suggest that for at least some bursts, the late intensity-tracking pulses could be a consequence of overlapping hard-to-soft pulses. However, the fact that the intensity-tracking pattern exists in the first pulse of the multi-pulse long GRBs and some single-pulse GRBs, suggests that intensity tracking is an independent component, which may operate in some late pulses as well. For the GRBs with measured redshifts, we present a time-resolved E{sub p} - L{sub {gamma},iso} correlation analysis and show that the scatter of the correlation is comparable to that of the global Amati/Yonetoku relation. We discuss the predictions of various radiation models regarding E{sub p} evolution, as well as the possibility of a precessing jet in GRBs. The data pose a great challenge to each of these models, and hold the key to unveiling the physics behind GRB prompt emission.

79 ASTRONOMY AND ASTROPHYSICS↗

Field deployable pushbroom hyperspectral imaging polarimeter

Hyperspectral imaging polarimetry enables both the spectrum and its spectrally-resolved state of polarization to be measured. This information is important to identify material properties for various applications in remote sensing and agricultural monitoring. In this paper, we describe the design and performance of a ruggedized, field deployable Hyperspectral Imaging Polarimeter (HIP), designed for wavelengths spanning the visible to near infrared (450-800 nm). An entrance slit was used to sample the scene in a pushbroom scanning mode across a 30 degree vertical by 110 degree horizontal field of view. Furthermore, athermalized achromatic retarders were implemented in a channel spectrum generator to measure the linear Stokes parameters. The mechanical and optical layout of the system and its peripherals are provided, in addition to the results of the sensor's spectral and polarimetric calibration. Finally, field measurements are also provided and an error analysis conducted. With its present calibration, the sensor has an absolute polarimetric error of 2.5% RIVIS and a relative spectral error of 2.3% RMS.

47 OTHER INSTRUMENTATION↗

Image Analysis for Rapid Assessment and Quality-Based Sorting of Corn Stover

Imaging in the visible spectrum is a low-cost tool that can be readily deployed for in-field or over-belt monitoring of biomass quality for bio-refining operations. Rapid image analysis coupled with innovative preprocessing may reduce the impacts of feedstock variability through identification of contaminants or other material attributes to guide selective sorting and quality management. Image analysis was employed to evaluate the quality of corn stover in red-green-blue (RGB) chromatic space. This study used controlled, bench-scale imaging as a proof-of-concept for rapid quality assessment of corn stover based on variations in material attributes, including chemical and physical attributes, that relate to biological degradation and soil contamination. Additionally, logistic regression-based classification algorithms were used to develop a method for biomass screening as a function of biological degradation or soil contamination. This study demonstrated the use of image analysis to extract features from RGB color space to investigate variations in critical material attributes from chemical composition of corn stover. Fourier transform infrared (FT-IR) suggested a correlation between red band intensity and biological degradation, while detailed surface texture analysis was found to distinguish among variations in ash. These insights offer promise for development of a rapid screening tool that could be deployed by farmers for in-field assessment of biomass quality or biorefinery operators for in-line sorting and process optimization.

09 BIOMASS FUELS↗