Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “slit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Autonomous attitude determination from star data for a dual-spin planetary spacecraft

A batch mode process which identifies three reference stars within a rotor-mounted star scanner's field-of-view based on the criteria of intensity and geometry was established. The sequential mode which continuously tracks the reference stars provides star transit times and estimates of rotor's spin rate. A least-square estimator was formulated which sequentially determines the spacecraft attitude from sucessive star crossings by minimizing the error in the star and scanner slit normal orthogonality. This spacecraft attitude also provides intermittent updates for the gyro propagated inertial attitude of the despun science platform. Simulation results are presented, showing successful star identification and attitude convergence in the presence of nutation and star transit time uncertainty.

Wong, E. C.↗

Fast generation of three-dimensional computational boundary-conforming periodic grids of C-type

A fast computer program, GRID3C, was developed to generate multilevel three dimensional, C type, periodic, boundary conforming grids for the calculation of realistic turbomachinery and propeller flow fields. The technique is based on two analytic functions that conformally map a cascade of semi-infinite slits to a cascade of doubly infinite strips on different Riemann sheets. Up to four consecutively refined three dimensional grids are automatically generated and permanently stored on four different computer tapes. Grid nonorthogonality is introduced by a separate coordinate shearing and stretching performed in each of three coordinate directions. The grids are easily clustered closer to the blade surface, the trailing and leading edges and the hub or shroud regions by changing appropriate input parameters. Hub and duct (or outer free boundary) have different axisymmetric shapes. A vortex sheet of arbitrary thickness emanating smoothly from the blade trailing edge is generated automatically by GRID3C. Blade cross sectional shape, chord length, twist angle, sweep angle, and dihedral angle can vary in an arbitrary smooth fashion in the spanwise direction.

Dulikravich, D. S.↗

The Faint Object Camera

The Faint Object Camera fully exploits the spatial resolution capability of the Space Telescope on the very faintest detectable objects over a broad wavelength range. A full complement of filters, objective prisms and polarizers, a choice of coronograhic masks, and a variety of scan formats extend the scientific versatility of the direct imaging mode. In addition, the Faint Object Camera provides the unique facility of long-slit spectroscopy to Space Telescope observers.

Macchetto, F.↗

Quiescent prominence spectrophotometry - Sodium D1,2, helium D3, and calcium /plus/ lambda 8498

The reported observations were carried out by means of a 25 cm coronagraph/coude spectrograph with a Si vidicon Optical Multichannel Analyzer (OMA) detector. The results of the investigation are presented in a number of tables, and the main conclusions concerning the studies are discussed. The relative behavior of prominence Na D line emission shows that the employed observing techniques yield reliable measures of prominence line strengths, not degraded to any substantial extent, in particular, by possible slit-filling effects. This conclusion is limited principally by the assumption that systematic vertical velocity fields in the prominences are not greater than 1.5 km/s. The Na D line profiles are well fitted by a one-component (i.e., homogeneous) line-forming region, thus reinforcing previous conclusions regarding the source of the enhanced wing emission.

Landman, D. A.↗

Echelle spectrographs at grazing incidence

It is shown that by using the conical diffraction mount, existing echelle gratings can be used at grazing incidence to achieve high spectral resolution in the extreme UV and soft X rays. Design considerations for grazing incidence echelle spectrographs are examined, and two sample designs are discussed. The first, for use in the extreme UV, has a primary mirror and an entrance slit to the spectrograph. The system has a resolution of 10,000, operates at any wavelength longward of 100 A, and covers 30% of the spectrum at a single setting. The X-ray spectrograph uses objective gratings to obtain spectral resolution of 28,000 over any factor of 2 in. wavelength. It operates to wavelengths as short as 4 A.

Cash, W.↗

Doppler wavelength shifts of ultraviolet spectral lines in solar active regions

Doppler shifts are measured for solar UV emission lines formed in the lower transition region of active regions. Doppler shifts in different regions at the same solar location, variations of Doppler shift with position of an active region on the disk, and variations of Doppler shift with time at the same solar location in the same active region were studied. Observations were made with the NRL slit spectrograph on Skylab. Excluding flare and flare-related phenomena, only redshifts are found whose magnitudes correspond to downflow velocities between about 4 and 17 km/s. Shifts are largest for lines formed between about 50,000 and 100,000 K, and are distinctly less for lines formed above 100,000 K. The shifts persist out to the limb, but not above it. There is no obvious change in redshift for lines measured at the same solar location over time intervals of about 20 minutes.

Feldman, U.↗

An efficient low- and moderate-resolution spectrograph for the Hale telescope

A new low-to-moderate resolution spectrograph has been designed and built for the Cassegrain focus of the Hale 5.08-meter telescope. To maximize efficiency, resolution, and wavelength coverage the light is divided into two spectra regions by a dichroic filter behind the entrance slit, after which there are two completely separate spectrographs. The blue spectrograph operates from 3200 A to 5200 A while the red one goes from 5200 A to 10,000 A. The red detector is an 800 x 800 TI CCD while the blue detector is a 320 x 512 RCA CCD or a Shectrograph image pulse-counting system. A Boksenberg IPCS can also be mounted on the blue camera. The overall efficiency of the Cassegrain telescope, spectrographs, and CCD's combined, ranges from 5 percent to 13 percent between 3600 A and 8200 A. The spectrograph is usable from 3200 A to 10,400 A.

Oke, J. B.↗

Measurements of the limb darkening of faculae near the solar limb

Measurements are presented of the contrast at 525 nm of solar faculae. The measurements were obtained using an extreme limb photometer (ELP) in 1975 and 1979 at the San Fernando Observatory. The mean contrast of active regions was determined from the limb inward to 54 arcsec, averaged over an annulus determined using the slits of the ELP. It is found that the contrast of faculae increases with heliocentric angle theta, from mu approximately 0.25 to mu approximately 0.065, where mu is the cosine of theta. The average value of the mean contrast of facular regions is 2.1%, with a possible upper limit of approximately 5% at mu approximately 0.1, determined from regions with the greatest filling factor. When corrected for a filling factor of 10-15%, this mean contrast implies a contrast for individual faculae of 30-50%.

Chapman, G. A.↗

Collecting Light From Point Images

Light from sources at varying positions brought to fixed opening. In telescope field divided into 10 strips, 10 pairs of optical fibers moved laterally and longitudinally to any required position in their assigned strips. Fixed ends of fibers arrayed in line at spectrograph entrance slit. Concept developed to enhance efficiency of spectrographs on astronomical telescopes.

Goss, W. C.↗

Lensless Image Scanner

Image scanner uses moving and stationary parallel slits to produce pictures of visible, infrared, X-ray microwave, or acoustic sources. No lenses or mirrors required. Single detector views all parts of image simultaneously rather than raster making relatively-short exposure times possible. Potential applications of system include medical x-ray imaging.

Schindler, R. A.↗

A microprocessor-based one dimensional optical data processor for spatial frequency analysis

A high degree of accuracy was obtained in measuring the spatial frequency spectrum of known samples using an optical data processor based on a microprocessor, which reliably collected intensity versus angle data. Stray light control, system alignment, and angle measurement problems were addressed and solved. The capabilities of the instrument were extended by the addition of appropriate optics to allow the use of different wavelengths of laser radiation and by increasing the travel limits of the rotating arm to + or - 160 degrees. The acquisition, storage, and plotting of data by the computer permits the researcher a free hand in data manipulation such as subtracting background scattering from a diffraction pattern. Tests conducted to verify the operation of the processor using a 25 mm diameter pinhole, a 39.37 line pairs per mm series of multiple slits, and a microscope slide coated with 1.091 mm diameter polystyrene latex spheres are described.

Collier, R. L.↗

Relations between mirror flats geometry and X-ray data

The X-ray data is used to determine the position where the mirror flats are properly aligned. The zero angle of incidence position of the mirrors is determined with the data. The mirrors are in the periscope geometry. However, the value of S sub T, the distance from the slit to the plane of the short mirror, is not fixed nor known a priori. This parameter plays a very important role in the zero position of the mirrors. As a further complicating factor, it is possible that the mirrors are not parallel. That is, they may be cocked by some angles alpha and beta, respectively. The relation between the X-ray data and the geometry of the mirrors is given. The experimental errors are given in terms of known or measured parameters.

Williams, A. C.↗

Compression and compression fatigue testing of composite laminates

The effects of moisture and temperature on the fatigue and fracture response of composite laminates under compression loads were investigated. The structural laminates studied were an intermediate stiffness graphite-epoxy composite (a typical angle ply laimna liminate had a typical fan blade laminate). Full and half penetration slits and impact delaminations were the defects examined. Results are presented which show the effects of moisture on the fracture and fatigue strength at room temperature, 394 K (250 F), and 422 K (300 F). Static tests results show the effects of defect size and type on the compression-fracture strength under moisture and thermal environments. The cyclic tests results compare the fatigue lives and residual compression strength under compression only and under tension-compression fatigue loading.

Porter, T. R.↗

Multibeam single frequency synthetic aperture radar processor for imaging separate range swaths

A single-frequency multibeam synthetic aperture radar for large swath imaging is disclosed. Each beam illuminates a separate ""footprint'' (i.e., range and azimuth interval). The distinct azimuth intervals for the separate beams produce a distinct Doppler frequency spectrum for each beam. After range correlation of raw data, an optical processor develops image data for the different beams by spatially separating the beams to place each beam of different Doppler frequency spectrum in a different location in the frequency plane as well as the imaging plane of the optical processor. Selection of a beam for imaging may be made in the frequency plane by adjusting the position of an aperture, or in the image plane by adjusting the position of a slit. The raw data may also be processed in digital form in an analogous manner.

Jain, A.↗

A general diagram for estimating pore size of ultrafiltration and reverse osmosis membranes

A slit sieve model has been used to develop a general correlation between the average pore size of the upstream surface of a membrane and the molecular weight of the solute which it retains by better than 80%. The pore size is determined by means of the correlation using the high retention data from an ultrafiltration (UF) or a reverse osmosis (RO) experiment. The pore population density can also be calculated from the flux data via appropriate equations.

Sarbolouki, M. N.↗

'Light bar' attitude indicator

The development and evaluation of a light bar attitude indicator to help maintain proper aircraft attitude during high altitude night flying is described. A standard four-inch ADI was modified to project an artificial horizon across the instrument panel for pitch and roll information. A light bulb was put in the center of the ADI and a thin slit cut on the horizon, resulting in a thin horizontal sheet of light projecting from the instrument. The intensity of the projected beam is such that it can only be seen in a darkened room or at night. The beam on the instrument panel of the T-37 jet trainer is shown, depicting various attitudes. The favorable comments of about 50 pilots who evaluated the instrument are summarized, including recommendations for improving the instrument. Possible uses for the instrument to ease the pilot task are listed. Two potential problems in using the device are the development of pilot complacency and an upright-inverted ambiguity in the instrument.

Enevoldson, E. K.↗

Real line strength distributions for random band models

An improved random band-model method, which makes allowance for the real line-strength distribution, is proposed. The model is shown to be useful for low-resolution, infrared observational data of the outer solar system. The method can be used as easily as conventional random band calculations. In the illustrative examples cited here, the variation of line width with J, the rotational quantum number, is small. Other effects which can, in principle, cause the model to deviate from laboratory observations are discussed. These include the assumption that line positions are random, ignoring the effects of the Lorentz wings of lines immediately outside the specific interval for which the mean transmission is calculated, and ignoring the effects of instrumental slit functions.

Kim, S. J.↗