Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “shielding effectiveness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Double-Plate Penetration Equations

This report compares seven double-plate penetration predictor equations for accuracy and effectiveness of a shield design. Three of the seven are the Johnson Space Center original, modified, and new Cour-Palais equations. The other four are the Nysmith, Lundeberg-Stern-Bristow, Burch, and Wilkinson equations. These equations, except the Wilkinson equation, were derived from test results, with the velocities ranging up to 8 km/sec. Spreadsheet software calculated the projectile diameters for various velocities for the different equations. The results were plotted on projectile diameter versus velocity graphs for the expected orbital debris impact velocities ranging from 2 to 15 km/sec. The new Cour-Palais double-plate penetration equation was compared to the modified Cour-Palais single-plate penetration equation. Then the predictions from each of the seven double-plate penetration equations were compared to each other for a chosen shield design. Finally, these results from the equations were compared with test results performed at the NASA Marshall Space Flight Center. Because the different equations predict a wide range of projectile diameters at any given velocity, it is very difficult to choose the "right" prediction equation for shield configurations other than those exactly used in the equations' development. Although developed for various materials, the penetration equations alone cannot be relied upon to accurately predict the effectiveness of a shield without using hypervelocity impact tests to verify the design.

Hayashida, K. B.↗

Performance of bismuth germanate active shielding on a balloon flight over Antarctica

The GRAD (Gamma-Ray Advanced Detector) gamma-ray spectrometer was flown on a balloon at an altitude of 36.6 km over Antarctica on January 8-10, 1988, where it was used to make observations of SN 1987A. The performance of the bismuth germanate (BGO) active shielding in the near-space environment over Antarctica is examined. The promised effectiveness of this shielding in the suppression of unwanted background has been demonstrated. The BGO-shielded GRAD spectrometer detected gamma-ray lines with fluxes of 0.002/sq cm sec from SN 1987A in a radiation background approximately a factor of 4 more intense than that over Alice Springs, Australia. This level of sensitivity indicates that BGO is at least as effective as CsI when used as active shielding. Isomerism is common, both in the bismuth and germanium regions of the nuclear chart, but is found to be less of a problem for background suppression in the latter region than in the former.

Rester, A. C.↗

Effect of a semi-annular thermal acoustic shield on jet exhaust noise

Reductions in jet exhaust noise obtained by the use of an annular thermal acoustic shield consisting of a high temperature, low velocity gas stream surrounding a high velocity central jet exhaust appear to be limited by multiple reflections. The effect of a semi-annular shield on jet exhaust noise was investigted with the rationale that such a configuration would eliminate or reduce the multiple reflection mechanism. Noise measurements for a 10 cm conical nozzle with a semi-annular acoustic shield are presented in terms of lossless free field data at various angular locations with respect to the nozzle. Measurements were made on both the shielded and unshielded sides of the nozzle. The results are presented parametrically, showing the effects of various shield and central system velocities and temperatures. Selected results are scaled up to a typical full scale engine size to determine the perceived noise level reductions.

Goodykoontz, J.↗

Gravity Scaling of a Power Reactor Water Shield

A similarity analysis on a water-based reactor shield examined the effect of gravity on free convection between a reactor shield inner and outer vessel boundaries. Two approaches established similarity between operation on the Earth and the Moon: 1) direct scaling of Rayleigh number equating gravity-surface heat flux products, 2) temperature difference between the wall and thermal boundary layer held constant. Nusselt number for natural convection (laminar and turbulent) is assumed of form Nu = CRa(sup n).

Reid, Robert S.↗

Solar modulation and nuclear fragmentation effects in galactic cosmic ray transport through shielding

Crews of manned interplanetary missions may accumulate significant radiation exposures from the Galactic Cosmic Ray (GCR) environment in space. Estimates of how these dose levels are affected by the assumed temporal and spatial variations in the composition of the GCR environment, and by the effects of the spacecraft and body self-shielding on the transported fields are presented. In this work, the physical processes through which shielding alters the transported radiation fields are described. We then present estimates of the effects on model calculations of (1) nuclear fragmentation model uncertainties, (2) solar modulation, (3) variations between solar cycles, and (4) proposed changes to the quality factors which relate dose equivalent to absorbed dose.

Townsend, L. W.↗

Radiation Shielding for Manned Deep Space Missions

The arrival of the Expedition 1 Crew at the International Space Station represents the beginning of the continuous presence of man in space. Already we are deploying astronauts and cosmonauts for missions of approx. 6 months onboard the ISS. In the future we can anticipate that more people will be in space and they will be there for longer periods. Even with 6-months deployments to the ISS, the radiation exposure that crew members receive is approaching the exposure limits imposed by the governments of the space- faring nations. In the future we can expect radiation protection to be a dominant consideration for long manned missions. Recognizing this, NASA has expanded their research program on radiation health. This program has three components, bioastronautics, fundamental biology and radiation shielding materials. Bioastronautics is concerned with the investigating the effects of radiation on humans. Fundamental biology investigates the basic mechanisms of radiation damage to tissue. Radiation shielding materials research focuses on developing accurate computational tools to predict the radiation shielding effectiveness of materials. It also investigates new materials that can be used for spacecraft. The radiation shielding materials program will be described and examples of results from the ongoing research will be shown.

Adams, James H., Jr.↗

Determine Important Nuclear Fragmentation Processes for Space Radiation Protection in Human Space Explorations

Space radiation from cosmic ray particles is one of the main challenges for long-term human space explorations such as a permanent moon base or a trip to Mars. Material shielding may provide significant radiation protection to astronauts, and models have been developed in order to evaluate the effectiveness of different shielding materials and to predict radiation environment inside the spacecraft. In this study we determine the nuclear fragmentation cross sections which will most effect the radiation risk behind typical radiation shielding materials. These cross sections thus need more theoretical studies and accurate experimental measurements in order for us to more precisely predict the radiation risk in human space explorations.

Lin, Zi-wei↗

Influence of mixer nozzle velocity decay characteristics on CTOL-OTW jet noise shielding

Jet noise shielding benefits for CTOL engine-over-the-wing configurations were obtained with model scale multitube and lobed mixer nozzles and various shielding surface geometries. Spectral data were obtained with jet velocities from 585 to 1110 ft/sec. Correlation equations for predicting jet noise shielding benefits with single conical nozzle installations were modified to correlate the mixer nozzle data. The modification included consideration of the number of nozzle elements and the peak axial velocity decay in the flow field adjacent to the shielding surface. The effect of forward velocity on jet noise attenuation by a shielding surface is discussed.

Vonglahn, U.↗

Influence of mixer nozzle velocity decay characteristics on CTOL-OTW jet noise shielding

Jet noise shielding benefits for CTOL engine-over-wing configurations were obtained with model-scale multitube and lobed mixer nozzles and various shielding surface geometries. Spectral data were obtained with jet velocities from 585 to 1110 ft/sec. Correlation equations for predicting jet noise shielding benefits with single conical nozzle installations were modified to correlate the mixer nozzle data. The modification included consideration of the number of nozzle elements and the peak axial velocity decay in the flow field adjacent to the shielding surface. The effect of forward velocity on jet noise attenuation by a shielding surface is discussed.

Von Glahn, U.↗

Neutrons in Space: Shield Models and Design Issues

The normal working and living areas of the astronaut are designed to provide an acceptable level of protection against the hazards of ionizing space radiation. Attempts to reduce the exposures require intervening shield materials to reduce the transmitted radiation. An unwelcome side effect of the shielding is the production of neutrons, which are themselves dangerous particles that can be (but are not always) more hazardous than the particles that produced them. This is especially true depending on the choice of shield materials. Although neutrons are not a normal part of the space environment, this paper focuses on them as principle component of astronaut exposure in the massive spacecraft's required for human space travel and habitation near planetary surfaces or other large bodies of material in space.

Wilson, J. W.↗

Monte Carlo simulation of shielding designs for a cabinet form factor preclinical MV–energy photon FLASH radiotherapy system

Purpose: A preclinical MV-energy photon FLASH radiotherapy system is being designed at Stanford and SLAC National Accelerator Laboratory. Because of the higher energy and dose rate compared to conventional kV-energy photon laboratory-scale irradiators, adequate shielding in a stand-alone cabinet form factor is more challenging to achieve. We present a Monte Carlo simulation of multilayered shielding for a compact self-shielding system without the need for a radiation therapy vault. Methods: A multilayered shielding approach using multiple alternating layers of high-Z and low-Z materials is applied to the self-shielded cabinet to effectively mitigate the secondary radiation produced and to allow the device to be housed in a Controlled Radiation Area outside of a radiation vault. The multilayered shielding approach takes advantage of the properties of high-Z and low-Z radiation shielding materials such as density, cross-section, atomic number of the shielding elements, and products of radiation interactions within each layer. The Monte Carlo radiation transport code, FLUKA, is used to simulate the total effective dose produced by the operation. Results: The multilayered shielding designs proposed and simulated produced effective dose rates significantly lower than monolayer designs with the same total material thickness at the regulatory boundary; this is accomplished through the manipulation of the locations where secondary radiation is produced and reactions due to material properties such as neutron back reflection in hydrogen. Borated polyethylene at 5 wt% significantly increased the shielding performance as compared to regular polyethylene, with the magnitude of the reduction depending upon the order of the shielding material. Conclusions: The multilayered shielding provides a path for shielding preclinical FLASH systems that deliver MV-energy bremsstrahlung photons. Furthermore, this approach promises to be more efficient with respect to the shielding material mass and space claim as compared to shielded vaults typically required for clinical radiation therapy with MV photons.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of slot width on transition and noise attenuation of a sound shield panel for supersonic wind tunnels

The effect of slot width on transition and noise attenuation of a planar rod wall sound shield has been investigated at Mach 6. Boundary layer laminarization was obtained by induced suction through adjustable slots or gaps between the rods. Transition Reynolds numbers increased significantly with increasing gap width. The local mean flow field above the suction panel rod array was uniform. Important factors for design and performance of a supersonic wind-tunnel sound shield are rod diameter, gap-to-rod diameter ratio, surface finish of the rods, and leading-edge configuration.

Harvey, W. D.↗

TID Effects of High-Z Material Spot Shields on FPGA Using MPTB Data

An experiment on the Microelectronics and Photonics Test Bed (MPTB) was testing lield programmable gate arrays using spot shields to extend the life of some of the devices being tested. It was expected that the unshielded parts would fail from a total ionizing dose (TID) and yet the opposite occurred. The data show that the devices failing from the TID effects are those with the spot shields attached. This effort is to determine the mechanism by which the environment is interacting with the high-Z material to enhance the TID in these field programmable gate arrays.

Hardage, Donna↗

Effects of velocity profile on boundary-layer shielding

A simple uniform flow boundary-layer model is used to study the effects on the acoustic field at the aircraft fuselage of placing Large Eddy Break Up devices in the boundary layer. The introduction of velocity defects into the boundary layer is shown to enhance boundary-layer shielding. Furthermore, shielding improvements are found to occur by moving the velocity defect further from the wall, by increasing its extent within the boundary layer, and by decreasing the minimum velocity in the defect.

Mcaninch, Gerry L.↗

Warpage-Resistant, Under-Extrusion-Free, High-Surface-Quality Additive Manufacturing Process for Polyethylene-Based Composite Radiation Shielding Material

Polyethylene (PE) is one of the best shielding materials for primary space radiation due to its high hydrogen content. For effective secondary neutron shielding, boron-rich fillers are incorporated to enhance performance. The semicrystalline nature and high thermal expansion coefficient of PE impede its adoption for in situ additive manufacture in space via the fused deposition modeling (FDM) 3D printing. Here, we developed an optimized PE blend to mitigate the effects of under-extrusion and warpage. Guided by studies on extrusion and warpage, we developed an optimal set of printing parameters for the proposed PE blend. The optimum PE blend─both in its pure form and when doped with fillers─has been tested on different FDM printers. The printed structures exhibit high and uniform density, smooth surfaces, no warpage, and competitive mechanical properties. The FDM-printed plates demonstrate efficient shielding from thermal neutrons, predicted via modeling and confirmed experimentally using extended Q-range small-angle neutron scattering.

additive manufacturing↗