Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Trace Chemical Detection Using Intercalated MXenes as a Signal Enhancing Substrate in Optical Probes

MXenes are 2D materials composed of layered transition metal nitrides or carbides. These materials are synthesized by HF exfoliation from MAX phases (Ti{sub 3}AlC{sub 2}). The 2D nanomaterial was synthesized by the removal of the 'A' element, resulting in a Mxene product (Ti{sub 3}C{sub 2}). MXenes have the general formula M{sub n+1}X{sub n}T{sub x}, where M is an early transition metal, X is Carbon and/or Nitrogen, and T accounts for surface terminated functional groups such as Fluoride, hydroxyl, and oxygen. These materials have very unique properties, similar to graphene, that allows them to be applied in a variety of trace detection techniques including surface-enhanced Raman spectroscopy (SERS). MXenes have also been demonstrated to selectively uptake uranyl ion, UO{sub 2}{sup 2+}. If this property can be combined with SERS or fluorescence detection, it may be possible to use MXenes as the basis for an alternative method to kinetic phosphorescence analysis (KPA) for trace uranyl measurements. Objectives: To confirm that MXene Nano materials are suitable substrates for SERS and sensor development by enhancing Raman signaling. To determine if certain MXene preparation methods yield materials that are more suitable for trace sensing methods. To determine uranyl uptake properties of these MXene materials and test them for analytical signals. Sample Preparation: Preparation of Ti{sub 3}C{sub 2}MXene (at FSU). MXenes were prepared by etching Al from Ti{sub 3}AlC{sub 2} (MAX phase)material. Two etching techniques yield different MXene products: LiF/HCl: Milder reaction, larger MXene flakes. HF: Harsher reaction, smaller flakes, larger layer separation. Products washed to remove etchant, vacuum filtered, and dried. Dried MXene flakes are air-stable. Film preparation for sensor testing (at SRNL): Suspend powder in diH{sub 2}O, purge with Ar, sonicate for 30 min. Centrifuge and collect supernate with suspended particles. Observed LiF-etched Mxene yielded a higher density of particles and darker collected solution. Drop-cast (4 ml) supernate onto slides and dried with Ar. For Rhodamine B (RhB) testing, drop-cast 4 ml drops onto Mxene spots and dried with Ar. Scanning Electron Microscopy conditions: 10 kV Beam energy, high vacuum; Working distance of 8 mm; beam penetration depth appx. 4 microns, beam spot size appx. 2 nanometers. Results: Detection of aluminum correlates with bright spots on image. Presence of aluminum shows that LiF/HCl etching was less thorough than HF etching. Trace Cl detection in LiF images suggests incomplete rinsing. HF has smaller feature size, more layer structure, and increased homogeneity, consistent with expectations. Macroscopic Raman spectroscopy measurements: 532 nm excitation, ∼50 mW with a ∼100 micron spot size (InPhotonics RPB probe). Kaiser Optical Holospec f/1.8 spectrometer with cooled (-60 deg.C) Andor iDus OE420 CCD. LiF 1x supernate showed good signal for trace measurements of Rhodamine B. HF and 1/4x LiF supernates showed little Mxene or Rhodamine B signal. Low deposition densities led to excess background signal from glass slides. For LiF film, response is linear with Rhodamine B concentration over range tested. Will retest with Raman microscope (∼1 micron spot size) to characterize SERS of more dilute LiF and HF etched Mxenes. Conclusions: The LiF etched material was more suitable for macroscopic SERS measurements because it was more concentrated, resulting in a thicker film than the HF etched Mxene and diluted LiF sample. However, the other materials may give greater SERS enhancements, which we hope to determine from measurements with the Raman microscope. From characterization with SEM we concluded that the HF etched Mxene is more uniform/homogenous and has smaller particle size than the LiF etched Mxene. There is still aluminum present in both samples indicating that etching wasn't complete, but the removal of the aluminum was more efficient in the HF method. Path Forward: Observe SERS with Raman microscopy, to obtain better signals for the more diluted samples and be able to compare enhancement effects for the different MXenes. Characterize uranyl sorption into MXene films and test Raman and fluorescence signals. Revisit the etching conditions to improve removal of aluminum. FSU and SRNL will continue to collaborate to create and characterize different Mxene materials and test their usefulness for sensor applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

FY 2019 Site-Directed Research & Development (Annual Report Overview)

This overview of the Fiscal Year 2019 Site-Directed Research & Development program and the Nevada National Security Site contains information regarding the program’s history and growth, leadership, project selection process, present areas of research, highlights of significant accomplishments and awards, noteworthy people, and performance metrics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electronics Free Laser Sensing Technology for Minerals and Technology Elements

This presentation presents an electronics free laser sensing technique and its ongoing and potential applications. A laser-based technique, popularly known as laser-induced breakdown spectroscopy has been prototyped for the determination of high-tech elements including rare earth elements and other elements in solid as well as aqueous sources. All optical unit without any electronics has been designed in such a way that it can be installed in the source environment and connected to other required components for controlling and data acquisition from the workstation. Measurement methods and results obtained for selected elemental species and overall performance of the developed prototype will be presented.

HCM Sensor↗

Detection of a Space Capsule Entering Earth’s Atmosphere with Distributed Acoustic Sensing (DAS)

On 24 September 2023, the Origins, Spectral Interpretation, Resource Identification, and Security-Regolith Explorer sample return capsule (SRC) entered Earth’s atmosphere after successfully collecting samples from an asteroid. The known trajectory and timing of this return provided a rare opportunity to strategically instrument sites to record geophysical signals produced by the capsule because it travelled at hypersonic speeds through the atmosphere. For this work, we deployed two distributed acoustic sensing (DAS) interrogators to sample over 12 km of surface-draped fiber-optic cables, as well as six collocated seismometer-infrasound sensor pairs, spread across two sites near Eureka, Nevada. This campaign-style rapid deployment is the first reported recording of an SRC re-entry with any distributed fiber-optic sensing technology. The DAS interrogators recorded an impulsive arrival with an extended coda which had features that were similar to recordings from both the seismometers and infrasound sensors. While the signal-to-noise ratio of the DAS data was lower than the seismic-infrasound data, the extremely dense spacing of fiber-optic sensors allowed for more phases to be clearly distinguished and the visualization of the continuous transformation of the wavefront as it impacted the ground. Unexpectedly, the DAS recordings contain less low-frequency content than is present in both the seismic and infrasound data. The deployment conditions strongly affected the recorded DAS data; in particular, we observed that fiber selection and placement exert strong controls on data quality.

58 GEOSCIENCES↗

Improving Cost and Efficiency of the Scalable Solid Oxide Fuel Cells Power System

The objective of this project was to design and develop a 20kW range small-scale solid oxide fuel cells (SOFC) power system for applications such as data centers and commercial buildings. The original plan included a 5,000 hours demonstration and a Techno-Economic Analysis (TEA) which were dropped as part of project termination. The original project plan was to use a stack with a cross-flow cell design which had previously been tested for 500 hours at a community college in Malta, NY. However, it was decided to move to the advanced R-SOFC co-flow cell developed under Department of Energy Award DE-FE0031971. The advanced cell design has the advantage of a larger active area for the same manufacturing footprint which results in fewer required cells for the same stack power, hence a higher volumetric power density (kW/L) and lower cost per kW than the original cross-flow cell design. A full SOFC system Simulink model was developed and calibrated with testing data from a fuel cell stack and BOP (balance of plant) components. The simulation results from the calibrated model showed an acceptable match with the experimental data. A structural analysis conducted for various load scenarios indicated no high stress areas for all spatial directions. Major electrical system components were acquired, built and successfully tested. System sensors were verified and validated against controls. Safety checks, a diagnostic check, PID tuning, and control software commissioning tasks were also conducted. The power electronics prototype was delivered and trial testing completed. Balance of Plant component testing and simulation work was conducted to characterize Reformer-Heat Exchanger heat transfer and backpressure and reformer catalyst methane conversion and product selectivity. Simulations were conducted to design the Anode and Cathode fluid passages and size the air-air and fuel-fuel heat exchangers. A Burner operation map was created from test data and the Anode Gas Recirculation blower was tested to evaluate its durability. The SOFC system used a horizontal style design where components sit directly on a casting with a direct connection to the skid. This design has efficient packaging and a small footprint with approximate dimensions of 750 mm x 700 mm x 1700 mm. An SOFC system was built and successfully tested at the Malta, NY facility The system for over 500 hours under load of which over 300 hours was at full load of 20 kW.

30 DIRECT ENERGY CONVERSION↗

Completion design improvement using a deep convolutional network

Maximizing stimulated natural and hydraulic fracture network is one of the primary hydraulic fracturing concerns for economic production from a horizontal shale gas well. Geomechanical facies and preexisting fractures in each stage are identified based on similarities in formation characteristics to optimize the locations of perforation clusters. This often requires analyzing large volumes of drilling, Logging While Drilling (LWD) and Measurement While Drilling (MWD) data. In this paper, we develop a methodology that calculates the mechanical specific energy (MSE) using real-time drill string acceleration signals directly from its definition. High resolution vibration signals have been collected using a tri-axial accerlometer, which was an auxiliary tool included in acoustic borehole imager. This technique provides a cost-efficient solution for engineered completion design. Furthermore, we adopt deep Convolutional Neural Network (CNN) with signal processing to build a data pipeline that effectively extracts patterns from dynamic acceleration signals for rock lateral MSE classification. First, we apply discrete wavelet transform and Short-Time Fourier Transform (STFT) for signal denoising and pattern recognition. Then we construct an image dataset using multi-scale image fusion at pixel level from 3 sensor channels, including axial, lateral acceleration spectrograms and zero-padded revolutions per minute (RPM). The resulted RGB image dataset includes 4,000 images of 5 MSE ranges with various rock strength conditions. Our results demonstrate that the proposed deep learning model can achieve more than 90% classification accuracy. The deep learning results, as a reference source, were applied in selected Marcellus Shale Energy and Environmental Lab (MSEEL) wells engineered completion located in the Marcellus shale gas site.

03 NATURAL GAS↗

Optics-Free Chip-Scale Intraoperative Imaging Using NIR-Excited Upconverting Nanoparticles

Here we present an optics-free CMOS image sensor that incorporates a novel time-gated dual-photodiode pixel design to allow filter- and lens-less image acquisition of near-infrared-excited (NIR-excited) upconverting nanoparticles. Recent biomedical advances have highlighted the benefits of NIR excitation, but NIR interaction with silicon has remained a challenge, even with high-performance optical blocking filters. Using a secondary diode and a dual-photodiode design, this sensor is able to remove the 100s of mV of NIR background on pixels and bring it down to single-digit mV level, nearing its noise floor of 2.2 mV rms, not achievable with any optical filter. Non-linear effects of background cancellation using the diode pair has been mitigated using an initial one-time pixel-level curve fitting and calibration in a post-processing setting. This imager comprises a highly linear 11 fF metal-oxide-metal (MOM) capacitor and includes integrated angle-selective gratings to reject oblique light and enhance sharpness. Each pixel also includes two distinct correlated double sampling schemes, to remove low frequency flicker noise and systematic offset in the datapath. We demonstrate the performance of this imager using pulsed NIR-excited upconverting nanoparticles on standard United-States-Air-Force (USAF) resolution targets and achieve an SNR of 15 dB, while keeping NIR background below 6 mV. This 36-by-80-pixel array measures only 2.3 mm by 4.8 mm and can be thinned down to 25 µm, allowing it to become surgically compatible with intraoperative instruments and equipment, while remaining optics-free.

42 ENGINEERING↗

Orientation matters: Measuring the correct surface of polyamide membranes with quartz crystal microbalance

The surface of polyamide reverse osmosis (RO) membranes which regulates interface-dominated phenomena, such as partitioning and fouling, is the one facing the feed during operation. However, the opposite surface of the polyamide selective layer, the one facing the permeate and in contact with the polysulfone porous support, is commonly analyzed in quartz crystal microbalance (QCM) measurements due to limitations of state-of-the-art transfer methodologies. Such measurements on the back surface cannot be generalized because the polyamide layer is chemically and morphologically asymmetric. Herein, we introduce a simple method to coat QCM sensors with polyamide active layers in the correct orientation (i.e., exposing their front surface) and show that interface-dominated phenomena differ significantly between orientations. We start by describing a transfer protocol to coat any surface with a polyamide layer on its front surface orientation. We then systematically analyze the chemical and morphological differences between the two surfaces of the polyamide layer of a commercial RO membrane. Finally, we demonstrate that interface-dominated phenomena depend on the orientation by showing that NaCl partitioning at pH 6 was 1.3 to 2.3-fold higher on the front surface and that organic fouling with humic acid occurred at a lower rate on this surface. The new method presented herein enables measurements on the front surface of polyamide RO membranes, which should be the standard in any future QCM studies.

Fouling behavior↗

Automatic Traffic Queue-End Identification using Location-Based Waze User Reports

Traffic queues, especially queues caused by non-recurrent events such as incidents, are unexpected to high-speed drivers approaching the end of queue (EOQ) and become safety concerns. Though the topic has been extensively studied, the identification of EOQ has been limited by the spatial-temporal resolution of traditional data sources. This study explores the potential of location-based crowdsourced data, specifically Waze user reports. It presents a dynamic clustering algorithm that can group the location-based reports in real time and identify the spatial-temporal extent of congestion as well as the EOQ. The algorithm is a spatial-temporal extension of the density-based spatial clustering of applications with noise (DBSCAN) algorithm for real-time streaming data with an adaptive threshold selection procedure. Here, the proposed method was tested with 34 traffic congestion cases in the Knoxville, Tennessee area of the United States. It is demonstrated that the algorithm can effectively detect spatial-temporal extent of congestion based on Waze report clusters and identify EOQ in real-time. The Waze report-based detection are compared to the detection based on roadside sensor data. The results are promising: The EOQ identification time of Waze is similar to the EOQ detection time of traffic sensor data, with only 1.1 min difference on average. In addition, Waze generates 1.9 EOQ detection points every mile, compared to 1.8 detection points generated by traffic sensor data, suggesting the two data sources are comparable in respect of reporting frequency. The results indicate that Waze is a valuable complementary source for EOQ detection where no traffic sensors are installed.

99 GENERAL AND MISCELLANEOUS↗

Conquering Data Chaos: Research Data Management with Kubernetes

Managing massive volumes of data and effectively making it accessible to researchers poses significant challenges and is a barrier to scientific discovery. In many cases, critical data is locked up in unwieldy file formats or one-off databases and is too large to effectively process on a single machine. This talk explores the role of Kubernetes, an open-source container orchestration platform, in addressing research data management challenges. I will discuss how we are using a set of publicly available open-source and home-grown tools in the National Renewable Energy Lab (NREL) Data, Analysis, and Visualization (DAV) group to help researchers overcome data-related bottlenecks. The talk will begin by providing an overview of the data challenges faced in research data management, including data storage, processing, and analysis. I will highlight Kubernetes' ability to handle large-scale data by leveraging containerization and distributed computing, including distributed storage. Kubernetes allows researchers to encapsulate data processing infrastructure and workflows into portable containers, enabling reproducibility and ease of deployment. Kubernetes can then schedule and manage the resource allocation of these containers to enable efficient utilization of limited computing resources, leading to more efficient data processing and analysis. I will discuss some limitations of traditional, siloed approaches to dealing with data and emphasize the need for solutions which foster collaboration. I will highlight how we are using Kubernetes at NREL to facilitate data sharing and cooperation among research teams. Kubernetes' flexible architecture enables the deployment of shared computing environments, such as Apache Superset, where researchers can seamlessly access and analyze shared datasets. Providing the ability to have one research team easily consume data generated by another, utilizing Kubernetes' as a central data platform, is one of the major wins we've encountered by adopting the platform. Finally, I will showcase real-world use cases from NREL where we have used Kubernetes to solve some persistent data challenges involving large volumes of sensor and monitoring data. I will discuss the challenges we encountered when creating our cluster and making it available as a production-ready resource. I will also discuss the specific suite of tools, including Postgres and Apache Druid for columnar and timeseries data, and Redpanda Kafka for streaming data we have deployed in our infrastructure, and the process that went into the selection of these tools.

collaborative environment↗

Smart Pixels: In-pixel AI for on-sensor data filtering

We present a smart pixel prototype readout integrated circuit (ROIC) designed in CMOS 28 nm bulk process, with in-pixel implementation of an artificial intelligence (AI) / machine learning (ML) based data filtering algorithm designed as proof-of-principle for a Phase III upgrade at the Large Hadron Collider (LHC) pixel detector. The first version of the ROIC consists of two matrices of 256 smart pixels, each 25$\times$25 $\mu$m$^2$ in size. Each pixel consists of a charge-sensitive preamplifier with leakage current compensation and three auto-zero comparators for a 2-bit flash-type ADC. The frontend is capable of synchronously digitizing the sensor charge within 25 ns. Measurement results show an equivalent noise charge (ENC) of $\sim$30e$^-$ and a total dispersion of $\sim$100e$^-$ The second version of the ROIC uses a fully connected two-layer neural network (NN) to process information from a cluster of 256 pixels to determine if the pattern corresponds to highly desirable high-momentum particle tracks for selection and readout. The digital NN is embedded in-between analog signal processing regions of the 256 pixels without increasing the pixel size and is implemented as fully combinatorial digital logic to minimize power consumption and eliminate clock distribution, and is active only in the presence of an input signal. The total power consumption of the neural network is $\sim$ 300 $\mu$W. The NN performs momentum classification based on the generated cluster patterns and even with a modest momentum threshold, it is capable of 54.4% - 75.4% total data rejection, opening the possibility of using the pixel information at 40MHz for the trigger. The total power consumption of analog and digital functions per pixel is $\sim$ 6 $\mu$W per pixel, which corresponds to $\sim$ 1 W/cm$^2$ staying within the experimental constraints.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surrogate Model of Flexible Research Platform EnergyPlus Models to Enable Sensitivity Analysis

This letter report describes the surrogate models developed from the EnergyPlus model of Oak Ridge National Laboratory’s Flexible Research Platform. Two data-driven black-box models were developed, and the outputs of the surrogate models were compared with the EnergyPlus model. The two models developed are a multilayer perceptron deep learning model, and a long short-term memory (LSTM) neural network model. The three factors for selecting the black-box models are scalability, computation time, and accuracy. A total of 107 input variables were the dominant variables in determining the outputs of building energy consumptions and thermal comfort. A total of 54 output variables were identified as the prediction targets, including the system- and zone-level outputs. The large set of the simulation cases were generated by integrating sensor errors into an emulator based on EnergyPlus and Python EMS, which includes advanced control sequences from ASHRAE Guideline 36-2018: High-Performance Sequences of Operation. The surrogate models were developed based on a set of large-scale simulation runs (i.e., 4,000 runs) on a cloud platform. The comparison analysis shows that the two black-box models had good accuracy for predicting new outputs for sensitivity analysis using the root mean square error metric. As a next step, the developed surrogate models will be used to perform sensitivity analysis for different sensor impacts (e.g., sensor types, sensor locations).

42 ENGINEERING↗

Smart Pixels: In-pixel AI for on-sensor data filtering

We present a smart pixel prototype readout integrated circuit (ROIC) designed in CMOS 28 nm bulk process, with in-pixel implementation of an artificial intelligence (AI) / machine learning (ML) based data filtering algorithm designed as proof-of-principle for a Phase III upgrade at the Large Hadron Collider (LHC) pixel detector. The first version of the ROIC consists of two matrices of 256 smart pixels, each 25$\times$25 µm\textsuperscript{2} in size. Each pixel consists of a charge-sensitive preamplifier with leakage current compensation and three auto-zero comparators for a 2-bit flash-type ADC. The frontend is capable of synchronously digitizing the sensor charge within 25 ns. Measurement results show an equivalent noise charge (ENC) of $\sim$30e\textsuperscript{-} and a total dispersion of $\sim$100e\textsuperscript{-} The second version of the ROIC uses a fully connected two-layer neural network (NN) to process information from a cluster of 256 pixels to determine if the pattern corresponds to highly desirable high-momentum particle tracks for selection and readout. The digital NN is embedded in-between analog signal processing regions of the 256 pixels without increasing the pixel size and is implemented as fully combinatorial digital logic to minimize power consumption and eliminate clock distribution, and is active only in the presence of an input signal. The total power consumption of the neural network is $\sim$ 300 $\mu$W. The NN performs momentum classification based on the generated cluster patterns and even with a modest momentum threshold, it is capable of 54.4\% – 75.4\% total data rejection, opening the possibility of using the pixel information at 40MHz for the trigger. The total power consumption of analog and digital functions per pixel is $\sim$ 6 $\mu$W per pixel, which corresponds to $\sim$ 1 W/cm\textsuperscript{2} staying within the experimental constraints.

Parpillon, Benjamin↗

Metabolites of Tobacco- and E-Cigarette-Related Nitrosamines Can Drive Cu 2+ -Mediated DNA Oxidation

Nitrosamine metabolites resulting from cigarette smoking and E-cigarette (E-cig) vaping cause DNA damage that can lead to genotoxicity. While DNA adducts of metabolites of nitrosamines 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK) and N-nitrosonornicotine (NNN) are well-known tobacco-related cancer biomarkers, only a few studies implicate NNN and NNK in DNA oxidation in humans. NNK and NNN were found in the urine of E-cigarette users who never smoked cigarettes. This paper proposes the first chemical pathways of DNA oxidation driven by NNK and NNN metabolites in redox reactions with Cu 2+ and NADPH leading to reactive oxygen species (ROS). A microfluidic array with thin films of DNA and metabolic enzymes that make metabolites of NNN and NNK in the presence of Cu 2+ and NADPH was used to estimate relative rates of DNA oxidation. Detection by electrochemiluminescence (ECL) employed a new ECL dye [Os(tpy-benz-COOH) 2 ] 2+ that is selective for and sensitive to the primary DNA oxidation product 8-oxo-7,8-dihydro-2-deoxyguanosine (8-oxodG) in DNA. Enzyme–DNA films on magnetic beads were used to produce nitrosamine metabolites that enter ROS-forming redox cycles with Cu 2+ and NADPH, and liquid chromatography–mass spectrometry (LC–MS) was used to quantify 8-oxodG and identify metabolites. ROS were detected by optical sensors. Metabolites of NNK and NNN + Cu 2+ + NADPH generated relatively high rates of DNA oxidation. Lung is the exposure route in smoking and vaping, human lung tissue contains Cu 2+ and NADPH, and lung microsomal enzymes gave the highest rates of DNA oxidation in this study. Furthermore, E-cigarette vapor contains 6-fold more copper than that in cigarette smoke, which could exacerbate DNA oxidation.

59 BASIC BIOLOGICAL SCIENCES↗

Tautomerism induces bending and twisting of biogenic crystals

Understanding and exploiting material flexibility through phenomena such as the bending and twisting of molecular crystals has been a subject of increased interest owing to the number of applications that benefit from these properties, such as optoelectronics, mechanophotonics, soft robotics, and smart sensors. Here, we report the growth of spontaneously bent and twisted ammonium urate crystals induced by the keto–enol tautomerism of the urate molecule. The major tautomer is native to biogenic crystals, whereas the minor tautomer functions as an effective crystal growth modifier to induce naturally bent and twisted ammonium urate crystals. We show that the degree of curvature can be tailored based on the judicious selection of growth conditions. A combination of state-of-the-art microscopy and spectroscopy techniques are used to characterize the origin of bending. Spatially resolved nano-electron diffraction and high-resolution electron microscopy of naturally bent crystals show nearly single crystallinity with local lattice deformations generated by a combination of screw and edge dislocations. These observations are consistent with photoinduced force microscopy and contact resonance atomic force microscopy, which confirmed spatially resolved changes in the intermolecular interactions and the mechanical properties throughout the cross-sectional and axial regions of bent crystals. A mechanism of bending involving the generation of regionally specific dislocations is proposed as an alternative to more commonly reported models. These findings highlight a unique characteristic of tautomeric crystals that may have broader implications for other biogenic materials.

Science & Technology - Other Topics↗

The Dark Energy Spectrographic Instrument (DESI) Guide-Focus Assembly

The specific research of the DESI project is to study in detail the expansion history of the Universe over the past 10 billion years. In order to do this, the project designed, fabricated, tested and commissioned the DESI instrument which has been deployed at the Mayall Telescope at the Kitt Peak National Observatory near Tucson, Arizona. The DESI project was conducted by approximately 30 US and foreign national laboratories. Our CRADA with the The Institut de Física d’Altes Energies (IFAE) in Barcelona (Spain) involved both research planning for eventual observing on the DESI telescope; and in providing hardware jointly designed by LBNL and IFAE; ten guide and focus sensor systems (GFAs) that either provide feedback to the Mayall telescope tracking system or provide focus position information to the DESI corrector hexapod. The key major goals of this CRADA were achieved.For survey planning, Drs. Fernandez, Fosalba, Garcia-Bellido, and Gaztañaga were all important contributors to the working groups to which they were assigned. Their application of redshift techniques, development of simulations to support target selection, exploration of the use of alternative observables to extract cosmological information like AP and void statistics, and the use of PAU data to assist in the optimization of targeting selections have been vital in the early planning for targets during commissioning. The major role in the project involved Drs. Castander, Miquel, Padilla, and Sànchez. They were all directly involved with the development of the Guide-Focus Assembly (GFA) hardware, software and filter validation. In order to accomplish the goals of the DESI Project, the Mayall telescope must track DESI targeted galaxies for up to 15 minutes and the DESI corrector must be repositioned on its hexapod system for different telescope orientations. The guide and focus assemblies (GFA) provide in this information. There are ten GFA modules on the focal plane, six providing tracking information and four providing focus information. A common GFA design supports both functions by a simple switching of its operating mode. IFAE designed, fabricated, tested and delivered twelve GFAs. Once received at LBNL, the GFAs were integrated with the focal plane. This was an iterative process as the GFA’s were delivered as they were made. Our working relationship with the IFAE scientists and engineers was remarkable given the distance and time zone issues. The GFAs have performed extremely well during the commissioning phase of the instrument.

79 ASTRONOMY AND ASTROPHYSICS↗

DECOVALEX-2023: Task D Final Report

Task D of DECOVALEX-2023 is focused on the simulation of the coupled thermal hydraulic-mechanical (THM) behaviour in the full-scale engineered barrier system (EBS). The Horonobe EBS experiment is the demonstration of the full-scale EBS in the underground research laboratory (URL) (performed by JAEA in the Horonobe URL in Japan). Task D consisted of the three steps, a preliminary step (Step 0), simulation of the laboratory tests (Step 1) and simulation of the in-situ full-scale EBS experiment (Step 2). Since the Horonobe EBS experiment demonstrates the vertical emplacement option of the EBS, the experiment gallery is also backfilled with the backfill material. Therefore, interaction between the EBS and the backfill material can also be demonstrated, such as deformation (change of density) of the buffer material. The underground water in the Horonobe URL is saline. This fact adds chemical processes to THM behaviour. For example, mechanical properties (such as swelling pressure of the buffer material and backfill material) and hydraulic properties (such as permeability of the buffer material and backfill material) change depending on the water chemistry. Task D was therefore a challenging Task focused on not only the relatively simple THM behaviour but also complex THM behaviour including chemical processes. Six research teams (BGR, CAS, JAEA, KAERI, SNL and Taipower) participated the Task D. BGR, CAS, JAEA, KAERI and Taipower research teams selected a THM approach, while the SNL research team selected a TH approach. Step 1 involved the simulation of laboratory test results and was important to check the numerical codes developed by the research teams. Step 1 was divided into four sub steps. The simulation results through the Step 1 identified the parameters for simulation of the Step 2. Basic parameters of the materials (buffer material, backfill material, rock mass, concrete, sand) were provided by JAEA. Special parameters which research team needed were identified by back analysis of Step 1. Most notably the mechanical behaviour of swelling and displacement depended on the applied model (elastic model or elastoplastic model). Parameters such as Young’s modulus were found to need smaller values than characterised in the fundamental laboratory test results (Step 1-1, 1-2) for the elastic model. Although laboratory experiments are usually simple, test results contained some error. For example, if the saturation level is 100 % or higher, it should be considered an error. This situation was presented in the Step 1-3. A possible reason is that the buffer material is a mixture of bentonite and silica sand. When a specimen is cut to measure volume or weight, sand grains will affect the measurement data. In Step 2, boundary conditions such as temperature on the surface of the simulated overpack, heater power of the electrical heaters installed in the simulated overpack, injection pressure and inflow rate of the test water, were applied. The outer boundary conditions can be selected using measured data (injection pressure and inflow rate of the test water that is controlled by the injection systems installed in the sand layer around the buffer material and in the boundary between backfill material and concrete support). Since such measured data has some noise, research teams developed their own simplified boundary conditions. Inner boundary conditions can be selected using measured data as heater power and temperature on the surface of the simulated overpack. These data also contain some noise, so research teams developed their own simplified developed boundary conditions. Task D validated various approaches thorough the simulation of the in-situ full scale EBS system including backfill of the gallery: variations in the coupling processes (THM or THC), analysis codes, and boundary conditions. Temperature distribution in the buffer material was simulated well by all research teams. This means thermal behaviour is not sensitive to the simulation approaches. Although the water content distribution on the outside of the buffer material was well simulated by all research teams, the simulation results differ from the measured values inside the buffer material (at the centre and inside, near the simulated overpack). The buffer material is made from tap water, but in the in-situ experiment, saline groundwater infiltrates the buffer material. Therefore, the selection of the hydraulic parameters of the buffer material greatly affects the simulation results of the re saturation behaviour of the buffer material. In the Horonobe EBS experiment, measured values suitable for validating the simulation results were not obtained near the simulated overpack. When simulating the pressure and deformation of the buffer material, the measurement data is easily affected by the installation conditions of the measurement sensors, so verifying the measurement data itself remains an issue. Mechanical simulation results differ depending on whether they are considered as elastic or elastoplastic phenomena. The accuracy of measured in-situ data can be assessed by detailed analysis comparing sampling specimen analysis and measured data. The Horonobe EBS experiment is scheduled to be dismantled in the future (FY2026 and 2027). This detailed dismantling investigation will finally confirm the measured data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Machine learning-based ethylene concentration estimation, real-time optimization and feedback control of an experimental electrochemical reactor

With the increase in electricity supply from clean energy sources, electrochemical reduction of carbon dioxide (CO 2 ) has received increasing attention as an alternative source of carbon-based fuels. As CO 2 reduction is becoming a stronger alternative for the clean production of chemicals, the need to model, optimize and control the electrochemical reduction of the CO 2 process becomes inevitable. However, on one hand, a first-principles model to represent the electrochemical CO 2 reduction has not been fully developed yet because of the complexity of its reaction mechanism, which makes it challenging to define a precise state-space model for the control system. On the other hand, the unavailability of efficient concentration measurement sensors continues to challenge our ability to develop feedback control systems. Gas chromatography (GC) is the most common equipment for monitoring the gas product composition, but it requires a period of time to analyze the sample, which means that GC can provide only delayed measurements during the operation. Moreover, the electrochemical CO 2 reduction process is catalyzed by a fast-deactivating copper catalyst and undergoes a selectivity shift from the product-of-interest at the later stages of experiments, which can pose a challenge for conventional control methods. To this end, machine learning (ML) techniques provide a potential approach to overcome those difficulties due to their demonstrated ability to capture the dynamic behavior of a chemical process from data. Motivated by the above considerations, we propose a machine learning-based modeling methodology that integrates support vector regression and first-principles modeling to capture the dynamic behavior of an experimental electrochemical reactor; this model, together with limited gas chromatography measurements, is employed to predict the evolution of gas-phase ethylene concentration. The model prediction is directly used in a proportional-integral (PI) controller that manipulates the applied potential to regulate the gas-phase ethylene concentration at energy-optimal set-point values computed by a real-time process optimizer (RTO). Specifically, the RTO calculates the operation set-point by solving an optimization problem to maximize the economic benefit of the reactor. Finally, suitable compensation methods are introduced to further account for the experimental uncertainties and handle catalyst deactivation. The proposed modeling, optimization, and control approaches are the first demonstration of active control for a CO 2 electrolyzer and contribute to the automation and scale-up efforts for electrified manufacturing of fuels and chemicals starting from CO 2 .

42 ENGINEERING↗