Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor data validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Low-cost sensor-based damage localization for large-area monitoring of FRP composites

Abstract In recent years, there has been growing interest in self-sensing structural materials across research and industry sectors. Detecting and locating structural damage typically requires numerous sensors wired to a data acquisition (DAQ) circuit, rendering implementation impractical in real structures. This paper proposes an innovative, cost-effective sensor network for damage detection and localization in fiber-reinforced polymer composites. The innovation encompasses three key elements: (1) utilizing carbon fiber tows within the composite as piezoresistive sensors, eliminating the need for additional foreign sensor devices; (2) introducing a novel sensor layout wherein sensor tow branches with varied resistance values are connected in parallel, reducing the number of connections to the DAQ circuit and cutting manufacturing costs significantly; (3) developing a practical sensor terminal fabrication technique to minimize manufacturing expenses. The proposed design methodology for the branch resistance values is first validated using a demonstration panel. Subsequently, the overall strategy is assessed by conducting impact tests on carbon and glass fiber-reinforced composite specimens. Results validate the sensor’s ability to accurately detect and locate structural damage.

Demo, Luke B. (ORCID:0000000208806522)↗

Effect of retransmission and retrodiction on estimation and fusion in long-haul sensor networks

In a long-haul sensor network, sensors are remotely deployed over a large geographical area to perform certain tasks, such as target tracking. In this work, we study the scenario where sensors take measurements of one or more dynamic targets and send state estimates of the targets to a fusion center via satellite links. The severe loss and delay inherent over the satellite channels reduce the number of estimates successfully arriving at the fusion center, thereby limiting the potential fusion gain and resulting in suboptimal accuracy performance of the fused estimates. In addition, the errors in target-sensor data association can also degrade the estimation performance. To mitigate the effect of imperfect communications on state estimation and fusion, we consider retransmission and retrodiction. The system adopts certain retransmission-based transport protocols so that lost messages can be recovered over time. Besides, retrodiction/smoothing techniques are applied so that the chances of incurring excess delay due to retransmission are greatly reduced. We analyze the extent to which retransmission and retrodiction can improve the performance of delay-sensitive target tracking tasks under variable communication loss and delay conditions. Lastly, simulation results of a ballistic target tracking application are shown in the end to demonstrate the validity of our analysis.

47 OTHER INSTRUMENTATION↗

Robust Online Monitoring for Calibration Assessment of Transmitters and Instrumentation

Robust online monitoring (OLM) technologies are expected to enable the extension or elimination of periodic sensor calibration intervals in operating and new reactors. These advances in OLM technologies will improve the safety and reliability of current and planned nuclear power systems through improved accuracy and increased reliability of sensors used to monitor key parameters. In this article, we discuss an overview of research being performed within the Nuclear Energy Enabling Technologies (NEET)/Advanced Sensors and Instrumentation (ASI) program, for the development of OLM algorithms to use sensor outputs and, in combination with other available information, 1) determine whether one or more sensors are out of calibration or failing and 2) replace a failing sensor with reliable, accurate sensor outputs. Algorithm development is focused on the following OLM functions: • Signal validation • Virtual sensing • Sensor response-time assessment These algorithms incorporate, at their base, a Gaussian Process-based uncertainty quantification (UQ) method. Various plant models (using kernel regression, GP, or hierarchical models) may be used to predict sensor responses under various plant conditions. These predicted responses can then be applied in fault detection (sensor output and response time) and in computing the correct value (virtual sensing) of a failing physical sensor. The methods being evaluated in this work can compute confidence levels along with the predicted sensor responses, and as a result, may have the potential for compensating for sensor drift in real-time (online recalibration). Evaluation was conducted using data from multiple sources (laboratory flow loops and plant data). Ongoing research in this project is focused on further evaluation of the algorithms, optimization for accuracy and computational efficiency, and integration into a suite of tools for robust OLM that are applicable to monitoring sensor calibration state in nuclear power plants.

fault detection↗

Identifying Controlling Variables for Mercury Vapors in Alpha-4 at Y-12: Two Year Data Collection Update

Multiple sensor packages were deployed at Alpha-4 by SRNL, in collaboration with United Cleanup Oak Ridge LLC (UCOR), to monitor mercury vapor concentrations and meteorological parameters. These sensors collected data, inside and outside of the legacy-use facility, for approximately two years. Though data gaps still exist, particularly in colder months, several controlling variables were identified that govern mercury vapor concentrations within Alpha-4. Temperature, barometric pressure gradients, humidity, and wind speed have been identified as controlling variables. A strong positive correlation was seen between mercury vapor concentrations and temperature which generally followed diurnal fluctuations. Temperatures below approximately 10 degrees Celsius did not show any spikes above the PEL, indicating more work can be performed at any time during the winter months – more data should be collected to confirm consistency in this finding. Additionally, spikes in mercury vapor concentrations above that of the permissible exposure limit (PEL; 100 µg/m 3 ) occurred primarily in late afternoon or evening/overnight hours (between 3 PM and 6 AM), which suggests D&D operations might be best scheduled during morning or daytime hours prior to the late afternoon. However, a limited number of spikes did occur outside of the identified window, although this may be attributed to disturbances in air flow and mercury vapor release from work activities performed inside of the Alpha-4 building. The analysis conducted allows for a strong predictive capability for estimating mercury vapor concentrations based upon accurate meteorological parameters. Still, additional data collection, particularly in the winter months, could help to strengthen the predictive power and validate the identified data trends. Further, increased temporal resolution could also help to better characterize the incipient stages of the increases and decreases in the mercury vapor concentration. Continued monitoring support by SRNL at Y-12 is underway at Alpha-4 to further close remaining data gaps and support deactivation and decommissioning work. Within a collaborative effort with UCOR, the SRNL team is collecting mercury vapor data to study the efficacy of a novel mercury suppressant, FerroBlack® which was recently deployed at Alpha-4. In addition, modifications to the current monitoring setup to increase measurement resolution is also being investigated.

54 ENVIRONMENTAL SCIENCES↗

Effects of EMF Emissions from Cables and Junction Boxes on Marine Species

Studies have shown that diverse aquatic species are electrosensitive. Many fishes, and marine mammals, can either detect, navigate by, or are affected by electromagnetic fields (EMF) with various sensitivities, and their behavior may be impacted by unnatural EMF emissions in the water column. Sharks, rays and skates are known to have the highest sensitivity to electric fields. Electric field emissions in the range 0.5–100 micro volt/m appear to attract them, and emissions over 100 micro volt/m to repulse them. A marine hydrokinetic MHK device will have multiple components and associated multiple submarine cables on the seafloor and running through the water column and would potentially increase the level of EMF emissions to which the marine species at the site may be exposed to. There are therefore concerns amongst stakeholders that EMF emissions associated with MHK devices and their components may act as barriers to species migration, cause disorientation, change community compositions and ecosystems, and that they may attract sharks, leading to a local increase in the risk of shark attacks. However, field data to validate and model potential relationships between observed responses and the EMF emissions in situ are sparse. A program of experimental field surveys were conducted off the coast of South Florida, USA to characterize the electromagnetic field (EMF) emissions in the water column from a submarine cable, and to monitor for responses of local aquatic species. The field surveys were conducted at the South Florida Ocean Measurement Facility (SFOMF) off Fort Lauderdale, which is a cabled offshore in-water navy range. It consists of multiple active submarine power cables and a number of junction boxes, with the capability to transmit AC/DC power at a range of strength and frequencies. The site includes significant marine life activities and community structure, including highly mobile species, such as sharks, stingrays, mammals and turtles. SFOMF therefore typifies a setting representative of an offshore location where a MHK device may be sited. Background electromagnetic field (EMF) levels and EMF emissions due to submarine cables were measured using a custom E-field sensor and a commercial magnetometer deployed from an autonomous underwater vehicle (AUV) at various fixed altitudes above the seafloor. EMF signatures detected from power cables and junction boxes are contrasted against ambient background levels and other EMF sources. The potential responses of local marine species were observed at selected representative locations using divers on SCUBA, complemented with fixed cameras on the sea bottom and by a set of video cameras mounted on the AUV. The objectives of the study were: 1) to characterize the EMF emission levels associated with submarine cables 2) to monitor potential responses of aquatic animals to the emissions and 3) to develop an associated database of field observations. As control, observations of EMF levels and in situ marine species were conducted with power in the cable turned off. Good quality measurements of EMF emissions were obtained using the mobile AUV platform and the data from the surveys were used to develop contour maps of the EMF levels in the water column above the live cable as well as to provide information about how the field decays away from the cable. The measurements show good agreement with theoretical models of the how EMF levels decay away from the cable in deep and shallow water environment. Electric fields in excess of 200µV/m were measured in the vicinity of the cable during the power on state. Quarterly surveys by SCUBA divers were conducted, using point and transect count methods, over a period of one year at three locations, one at a shallow site where the water depth is approximately 5m, and the other at the Barracuda Reef where the water depth is approximately 10m. The sampling results were analyzed to determine if the presence of an SFOMF generated EMF alters: (1) abundance, species richness, and assemblage structure of coral reef fishes, (2) the behavior of fishes including elasmobranchs, and (3) the distribution of marine turtles and mammals. Diver observations were also used in attempt to discern if there were any noticeable organismal responses during the transitional period between ambient OFF to energized AC or DC power states, and video footage was intended to augment the in-situ visual survey data and aid in interpretation of the results. Comparisons are provided between observation datasets between the three sites and between the point and transect count methods. Presence of several individual elasmobranch species, including sharks and stingrays, were recorded during the surveys. No apparent effect on richness could be discerned between the power on and off states. No apparent sudden animal movements were observed during transitions between power states.

16 TIDAL AND WAVE POWER↗

Recursive Dynamic Compressive Sensing in Smart Distribution Systems

With a transition to a smarter grid, we are witnessing a significant growth in smart metering infrastructure and sensor deployment in the distribution system. The underlying communication infrastructure is stressed due to the large volume of data that is generated by the smart meters/sensors. Furthermore, real time operations such as state estimation and control are impaired due to the lack of reliable aggregation of the data. In this paper, we exploit the underlying sparsity in grid data to implement two recursive dynamic compressive sensing (CS) approaches-streaming modified weighted-`1 CS and Kalman filtered CS. These approaches aim to reconstruct the sparse signal using the current underdetermined measurements and the prior information about the sparse signal and its support set. Slow signal and support change is in distribution grid data is validated using Pecan Street data. Both the IEEE 34 node test feeder system and PecanStreet data are considered as two examples to validate the superior performance of the two recursive CS techniques relative to classic CS.

Karimi, Hazhar Sufi↗

Extending Component Lifetime And Improving Inverter Reliability (ECLAIIR)

Inverter reliability remains one of the most persistent challenges limiting the performance, availability, and economic viability of utility‑scale photovoltaic (PV) plants. Industry data consistently show that inverters account for the highest share of corrective maintenance events and unplanned outages across PV fleets. These failures result in energy losses, increased O&M costs, and reduced confidence in long‑term solar asset performance. Motivated by these challenges, this project—Extending Component Lifetime and Improving Inverter Reliability (ECLAIIR)—was undertaken to systematically investigate inverter degradation and failure mechanisms, develop predictive maintenance capabilities, and establish data‑driven pathways to improve service life and reduce the Levelized Cost of Energy (LCOE) for large‑scale PV systems. The primary goal of the project was to identify pre‑failure signatures in string inverters using both lab‑based accelerated lifetime testing and field‑based data and to develop predictive maintenance algorithms that can anticipate inverter faults before they occur. Through collaboration with inverter testing laboratory, solar PV plant owner, and failure‑analysis experts, the project advanced the technical understanding of inverter reliability. By instrumenting inverters with thermistors, humidity sensors, power‑quality meters, and acoustic sensors, the research established how multiple sensing modalities can reliably detect deviations from normal behavior hours to days before failure. These findings substantially enhance scientific understanding of inverter failure kinetics and provide the PV industry with the most comprehensive cross‑OEM characterization of early‑stage failure indicators reported to date. Technically, the project demonstrated the effectiveness of predictive maintenance by developing and validating the PreDICT (Predictive Diagnostics of PV Inverters Using Condition Monitoring and Trend Analysis) framework—a multi‑layer diagnostic architecture combining peer‑to‑peer analytics, historical trend modeling, and advanced machine‑learning techniques such as the Sequential Conditional Variational Autoencoder (SCVAE). This predictive model achieved more than 90% accuracy in detecting pre‑failure conditions and provided up to four days of lead time before inverter failure in field scenarios. Economically, the project’s LCOE analysis showed that predictive maintenance can reduce lifetime energy losses and minimize corrective maintenance interventions. Modeling indicated that, depending on inverter failure rates and replacement timelines, predictive maintenance can significantly reduce LCOE impacts associated with inverter downtime: from as high as 19.4% under conventional maintenance strategies to 0.1%–10.17% when predictive analytics are adopted. These results confirm that predictive maintenance is both technically feasible and economically advantageous for utilities and plant operators. The project’s findings also have broad public benefit. By improving inverter reliability and reducing downtime, predictive maintenance directly increases electricity generation from existing PV assets. Enhanced reliability lowers operational costs for utilities, which can translate over time into lower energy costs for consumers. Furthermore, the project’s technical publications, conference presentations, and industry workshops ensure that knowledge gained is shared broadly across the solar industry, supporting workforce development and enabling utilities of all sizes to adopt modern asset‑health monitoring practices. The retrofitting case study and service‑life prediction framework further support informed decision‑making for aging PV fleets, helping operators extend system life and reduce electronic waste. In summary, the ECLAIIR project significantly advanced the state of knowledge on inverter degradation, demonstrated the technical and economic value of predictive maintenance, and delivered actionable tools and insights that support more reliable, cost‑effective, and sustainable PV plant operation. The outcomes of this project will continue to inform utility practices, guide inverter design improvements, and strengthen the long‑term performance of solar assets nationwide.

14 SOLAR ENERGY↗

EcoSpec: Highly Equipped Tower-Based Hyperspectral and Thermal Infrared Automatic Remote Sensing System for Investigating Plant Responses to Environmental Changes

Despite an advanced ability to forecast ecosystem functions and climate at regional and global scales, little is known about relationships between local variations in water and carbon fluxes and large-scale phenomena. To enable data collection of local-scale ecosystem functions to support such investigations, we developed the EcoSpec system, a highly equipped remote sensing system that houses a hyperspectral radiometer (350–2500 nm) and five optical and infrared sensors in a compact tower. Its custom software controls the sequence and timing of movement of the sensors and system components and collects measurements at 12 locations around the tower. The data collected using the system was processed to remove sun-angle effects, and spectral vegetation indices computed from the data (i.e., the Normalized Difference Vegetation Index (NDVI), Normalized Difference Water Index (NDWI), Photochemical Reflectance Index (PRI), and Moisture Stress Index (MSI)) were compared with the fraction of photochemically active radiation (fPAR) and canopy temperature. The results showed that the NDVI, NDWI, and PRI were strongly correlated with fPAR; the MSI was correlated with canopy temperature at the diurnal scale. These correlations suggest that this type of near-surface remote sensing system would complement existing observatories to validate satellite remote sensing observations and link local and large-scale phenomena to improve our ability to forecast ecosystem functions and climate. The system is also relevant for precision agriculture to study crop growth, detect disease and pests, and compare traits of cultivars.

47 OTHER INSTRUMENTATION↗

Staggered scheduling of sensor estimation and fusion for tracking over long-haul links

Networked sensing can be found in a multitude of real-world applications. Here, we focus on the communication-and computation-constrained long-haul sensor networks, where sensors are remotely deployed over a vast geographical area to perform certain tasks. Of special interest is a class of such networks where sensors take measurements of one or more dynamic targets and send their state estimates to a remote fusion center via long-haul satellite links. The severe loss and delay over such links can easily reduce the amount of sensor data received by the fusion center, thereby limiting the potential information fusion gain and resulting in suboptimal tracking performance. In this paper, starting with the temporal-domain staggered estimation for an individual sensor, we explore the impact of the so-called intra-state prediction and retrodiction on estimation errors. We then investigate the effect of such estimation scheduling across different sensors on the spatial-domain fusion performance, where the sensing time epochs across sensors are scheduled in an asynchronous and staggered manner. In particular, the impact of communication delay and loss as well as sensor bias on such scheduling is explored by means of numerical and simulation studies that demonstrate the validity of our analysis.

47 OTHER INSTRUMENTATION↗

Ultra-high Bandwidth, Ultra-high Dynamic Range X-Ray Shock Characterization via Photonic Integrated Circuit

Nuclear weapon component assessment tests at the Z Machine rely on accurate X-ray yield measurements for model validation, design and analysis of component survivability, and source optimization. Yield measurement devices currently used do not provide the requisite certainty to enable accurate and efficient data analysis of test results, which leads to an increase in Z-shots required for evaluation, longer device development times, and higher operation costs. Additionally, current X-ray flux detectors lack high temporal resolution at the tails. Similarly, shock measurement techniques used for component assessment often lack the ability to spatially resolve wave behavior thereby limiting the ability to measure shock propagation dynamics needed to design the next generation of ND components. Here we present the development of a photonic micro-calorimeter and shock sensor consisting of meter-long waveguide spirals that are optomechanically coupled to X-ray absorbing layers to characterize yield and shock propagation at nanosecond timescales.

42 ENGINEERING↗

Search for Infrasound Signals in InSight Data Using Coupled Pressure/Ground Deformation Methods

The unprecedented quality and sampling rate of seismometer and pressure sensors of the InSight Mars mission allow us to investigate infrasound through its pressure and ground deformation signals. This study focuses on compliance effects induced by acoustic waves propagating almost horizontally close to the surface. The compliance of acoustic waves is first estimated using the compliance estimates from pressure perturbations moving at wind speed. Then, a marker of compliance events is used to detect events of ground deformation induced by pressure variations, in three frequency bands from 0.4 to 3.2 Hz, from InSight sol 180 to 690. Additional selection criteria are imposed on the detected events to focus on acoustic waves and to remove various noise sources (e.g., wind effects or seismometer artifacts). After an automated selection, the visual inspection of the records allows us to validate two infrasound candidates that cannot be related to pressure perturbations moving at wind speed nor to known noise sources. For our highest quality infrasound candidate, the relation between this event and a convective vortex occuring 10 s later is tested. The azimuth of the vortex position at the time of infrasound detection is not consistent with the arrival azimuth of the suspected infrasound inferred from the polarization of seismometer records, thus the link between these two phenomena cannot be demonstrated. Further investigations would require a better understanding of wind-related noise impacting InSight sensors and of the effects of lateral variations of subsurface mechanical properties on the ground deformations induced by atmospheric pressure variations.

58 GEOSCIENCES↗

Temperature Field Reconstruction of Surfaces Heated Through Radiative Heat Transfer Using Convolutional Neural Networks

Microreactors could play a crucial role in decarbonizing our energy portfolio. However, their development and implementation come with specific challenges, particularly regarding cost. Due to their compact size and the harsh operational environment, collecting real-time data on reactor operation can be challenging. Many probe designs are unable to withstand extreme conditions (e.g., temperature, radiation) in the reactor. In this context, using convolutional neural networks (CNNs) can pave the way for developing a nonintrusive approach that relies solely on ex-core sensors. A well-trained physics-informed CNN can reconstruct the distribution of a given physical quantity over a domain using only a few sensors, allowing us to reconstruct the desired field distribution even in a limited space or complex geometries where a large array of sensors is impractical. In this work, we present the initial steps toward developing a real-time tool for monitoring the thermal behavior of nuclear reactor pressure vessels. Based on an experimental setup, a computational model using the Multiphysics Object-Oriented Simulation Environment (moose) framework was built, where the Ray Tracing and Heat Conduction modules were used to evaluate the temperature distribution over a convex metal surface heated through radiative heat transfer. This metal surface represents a section of a heated nuclear reactor vessel wall. The model also accounts for solid mechanics physics through the moose Solid Mechanics module. In situ experimental data, acquired from a Texas A&M facility, were used to validate the computational model. Part of the data generated by the moose model was used to train the convolutional neural network to reconstruct the vessel wall's outer surface temperature. The CNN generalization was then compared against the experimental and computational data.

Aldeia Machado, Luiz Carlos↗

Distributed Wireless Antenna Sensors for Boiler Condition Monitoring

Monitoring the operational conditions of coal-fired boilers is an important task that could bring tremendous benefits, including in-situ process control, real-time health assessment of structural components, improved heat transfer efficiency, reduced downtime, etc. Moreover, in-situ distributed sensing of the boiler conditions would provide large scale in-situ measurement data that will help us gain fundamental understandings of the combustion and heat transfer processes as well as enable the developments of new simulation tools, which could eventually lead to better design and more efficient operation of the boilers. The objectives of this research were to (a) develop wireless passive antenna sensors without electronics; (b) demonstrate multi-modality sensing using a signal antenna sensor; and (c) fabricate the antenna sensor from high-temperature materials. In this project, we have demonstrated that an antenna sensor or sensor array without any electronics can be wirelessly interrogated from a distance. In addition, a low-cost compact wireless sensor interrogator was developed for dynamic interrogation of the passive antenna sensor. We validated that a dual-frequency antenna sensor is capable of simultaneous strain and temperature measurements or temperature and ash accumulation measurements; all parameters are relevant to boiler condition monitoring. By measuring the temperature and ash accumulation height simultaneously, the dielectric constant of the ash as well as its temperature dependency can also be characterized. This capability could lead to potential applications of the antenna sensor for combustion process monitoring based on the ash composition. We also investigated different techniques of fabricating the antenna sensor using high-temperature materials such as alumina substrate and platinum paste and characterized the thermal response of the antenna sensor. A linear relationship between the antenna resonant frequency and the temperature change was validated.

20 FOSSIL-FUELED POWER PLANTS↗

Field validation of dynamic mechanical torque measurements using fiber-optic strain sensors for geared wind turbines

Abstract Accurate knowledge of the mechanical loads of wind turbine gearboxes has become essential in modern, highly loaded gearbox designs, as maintaining or even improving gearbox reliability with increasing torque density demands is proving to be challenging. Unfortunately, the traditional method of measuring dynamic mechanical torque using strain gauges placed on the outer surface of a rotating shaft and transmitting the resulting signal is unsuitable for serial deployment due to technical and economic constraints. An alternative method based on fiber-optic strain sensors placed on the stationary outer surface of the gearbox ring gear has been proposed. Like shaft torsion, the radial deformation of the ring gear is proportionate to the rotor torque. Placing the sensors on a stationary component is a cost-effective alternative for serial implementation because the need for complex and expensive data transfer via wireless transmission or a slip ring is eliminated. In this paper, we present the results of an extensive field experiment conducted to evaluate the torque measurement accuracy of this novel sensing solution installed on the gearbox of a Gamesa G97 2-MW wind turbine at the National Renewable Energy Laboratory’s Flatirons Campus. Torque measurements derived from fiber-optic strain sensors placed on the ring gear of the planetary stage are compared to conventional torque measurements from strain gauges placed on the main shaft. Two different torque estimation data processing methods were evaluated, with the method based on operational deflection shapes providing the most accurate results with an average normalized root mean square error below 0.7% for a load revolution distribution analysis. The effect of operating conditions on the torque estimate was also investigated, and the third planet-passing operational deflection shape was found to be the least sensitive to nontorque load-related effects. The fiber-optic strain sensors’ successful operation during the complete test campaign has demonstrated a robust and accurate solution for fleet-wide enhanced gearbox remaining useful life estimation.

17 WIND ENERGY↗

Pilot-Scale Validation of Distributed Optical Fiber Sensors for Underground Pipeline Monitoring

Monitoring parameters such as hoop strain, pressure, and acoustic vibrations is key to detecting potential leaks, intrusions, or structural issues. Distributed optical fiber sensor (DOFS) systems provide a compelling solution for continuous, real-time monitoring over long distances. This paper details the development and pilot-scale implementation of DOFS systems for underground pipeline monitoring, evolving from a proof-of-concept stage. Multiple custom-designed DOFS interrogator units—such as optical frequency-domain reflectometry (OFDR), Brillouin optical time-domain analysis (BOTDA), and multimodal interferometer-based fiber acoustic sensor systems were tested to measure the key parameters, such as hoop strain, pipe pressure, surrounding soil temperature, and acoustic vibrations. The underground product pipeline’s outer diameter is 30 inches, the wall thickness is 1.28 inches, and 3 feet deep from the surface. The fiber deployment strategies and sensing data acquisition methods for these systems are discussed. The results demonstrate the effectiveness of DOFS in detecting hoop strain, temperature changes, and acoustic vibrations, showcasing their potential for real-time monitoring and enhancing pipeline safety. These findings from pilot-scale testing offer valuable insights into advancing pipeline monitoring technologies and improving the reliability of underground pipeline systems.

fiber optic sensors↗

Creation of Speed-of-Sound Inject Data for Technical Nuclear Forensics

Technical Nuclear Forensics (TNF) exercises simulate a detonation of a nuclear device within the United States, usually in a city. Speed-of-sound (SOS) phenomenology are the atmospheric overpressure and ground shock mechanical motions that are observed at over-pressure (air-blast and infrasound) and seismic sensors, respectively (Figure 1). Amplitudes of SOS data are related to the explosive yield (Kinney and Graham, 1985; Koper et al., 2002; Bonner et al., 2013ab; Ford et al., 2014, 2021; Templeton et al., 2018; Schnurr et al., 2020). Within the country, the United States Prompt Diagnostics System (USPDS) includes a network of geophysical sensors to capture such SOS signals. During the TNF exercise, the event data will be analyzed by the players who know nothing about the technical details of the source (e.g. location, yield, explosive). Specifically, they will use the Integrated Yield Determination Tool (IYDT) to estimate the yield and height-of-burst or depth-of-burial (HOB/DOB). The IYDT allows the user to measure features on the overpressure and seismic channels, evaluate the consistency of features and jointly estimate yield and HOB/DOB. For these exercises, SOS data are simulated for the location, emplacement and yield of the device and signals are propagated to the observing stations. This document describes the steps undertaken in the simulation, validation, preparation and verification of SOS signals for TNF exercises.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

A digital twin solution for floating offshore wind turbines validated using a full-scale prototype

Abstract. In this work, we implement, verify, and validate a physics-based digital twin solution applied to a floating offshore wind turbine. The digital twin is validated using measurement data from the full-scale TetraSpar prototype. We focus on the estimation of the aerodynamic loads, wind speed, and section loads along the tower, with the aim of estimating the fatigue lifetime of the tower. Our digital twin solution integrates (1) a Kalman filter to estimate the structural states based on a linear model of the structure and measurements from the turbine, (2) an aerodynamic estimator, and (3) a physics-based virtual sensing procedure to obtain the loads along the tower. The digital twin relies on a set of measurements that are expected to be available on any existing wind turbine (power, pitch, rotor speed, and tower acceleration) and motion sensors that are likely to be standard measurements for a floating platform (inclinometers and GPS sensors). We explore two different pathways to obtain physics-based models: a suite of dedicated Python tools implemented as part of this work and the OpenFAST linearization feature. In our final version of the digital twin, we use components from both approaches. We perform different numerical experiments to verify the individual models of the digital twin. In this simulation realm, we obtain estimated damage equivalent loads of the tower fore–aft bending moment with an accuracy of approximately 5 % to 10 %. When comparing the digital twin estimations with the measurements from the TetraSpar prototype, the errors increased to 10 %–15 % on average. Overall, the accuracy of the results is promising and demonstrates the possibility of using digital twin solutions to estimate fatigue loads on floating offshore wind turbines. A natural continuation of this work would be to implement the monitoring and diagnostics aspect of the digital twin to inform operation and maintenance decisions. The digital twin solution is provided with examples as part of an open-source repository.

17 WIND ENERGY↗

An in-depth field validation of “DUSST”: A novel low-maintenance soiling measurement device

This study presents indoor and field validation results for two versions of the “DUSST” optical soiling sensor, intended to be a low-cost and low-maintenance device for measuring photovoltaic soiling losses. Indoor testing covers irradiance calibration and temperature dependencies, which are necessary to achieve high accuracy, low uncertainty field measurements. Field testing includes an array of different environments including Saudi Arabia, California, Utah, and Colorado. DUSST versions include a configuration with a 530-nm light emitting diode (LED) (discussed in previous work) and a unit with seven white LEDs and a polycarbonate collimating optic. The new design increases light intensity fivefold and demonstrates a single linear calibration coefficient is effective to measure soiling losses as high as 75%. Field data from Utah and California demonstrate that daily soiling loss measurements and soiling rate calculations closely match both reference cell and full-size module measurements of soiling losses and soiling rates. Corrective methods employed on the Utah DUSST sensor suggest that it is possible to achieve measurement errors as low as ±0.1% at two standard deviations. Field data from both Colorado and Saudi Arabia demonstrate that LED lens soiling can occur and that further design optimizations are needed. The lesson learned from all the field deployment locations suggests directions for future design improvements.

14 SOLAR ENERGY↗