Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scan report”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

TU-H-207A-08: Estimating Radiation Dose From Low-Dose Lung Cancer Screening CT Exams Using Tube Current Modulation

Purpose: The purpose of this work is to estimate effective and lung doses from a low-dose lung cancer screening CT protocol using Tube Current Modulation (TCM) across patient models of different sizes. Methods: Monte Carlo simulation methods were used to estimate effective and lung doses from a low-dose lung cancer screening protocol for a 64-slice CT (Sensation 64, Siemens Healthcare) that used TCM. Scanning parameters were from the AAPM protocols. Ten GSF voxelized patient models were used and had all radiosensitive organs identified to facilitate estimating both organ and effective doses. Predicted TCM schemes for each patient model were generated using a validated method wherein tissue attenuation characteristics and scanner limitations were used to determine the TCM output as a function of table position and source angle. The water equivalent diameter (WED) was determined by estimating the attenuation at the center of the scan volume for each patient model. Monte Carlo simulations were performed using the unique TCM scheme for each patient model. Lung doses were tallied and effective doses were estimated using ICRP 103 tissue weighting factors. Effective and lung dose values were normalized by scanspecific 32 cm CTDIvol values based upon the average tube current across the entire simulated scan. Absolute and normalized doses were reported as a function of WED for each patient. Results: For all ten patients modeled, the effective dose using TCM protocols was below 1.5 mSv. Smaller sized patient models experienced lower absolute doses compared to larger sized patients. Normalized effective and lung doses showed some dependence on patient size (R2 = 0.77 and 0.78, respectively). Conclusion: Effective doses for a low-dose lung screening protocol using TCM were below 1.5 mSv for all patient models used in this study. Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics.

60 APPLIED LIFE SCIENCES↗

Shallow-etched thin-film lithium niobate waveguides for highly-efficient second-harmonic generation

High-fidelity periodic poling over long lengths is required for robust, quasi-phase-matched second-harmonic generation using the fundamental, quasi-TE polarized waveguide modes in a thin-film lithium niobate (TFLN) waveguide. Here, a shallow-etched ridge waveguide is fabricated in x-cut magnesium oxide doped TFLN and is poled accurately over 5 mm. The high fidelity of the poling is demonstrated over long lengths using a non-destructive technique of confocal scanning second-harmonic microscopy. We report a second-harmonic conversion efficiency of up to 939 %.W −1 (length-normalized conversion efficiency 3757 %.W −1 .cm −2 ), measured at telecommunications wavelengths. The device demonstrates a narrow spectral linewidth (1 nm) and can be tuned precisely with a tuning characteristic of 0.1 nm/°C, over at least 40 °C without measurable loss of efficiency.

Zhao, Jie (ORCID:0000000306230125)↗

Accelerated deep self-supervised ptycho-laminography for three-dimensional nanoscale imaging of integrated circuits

Three-dimensional inspection of nanostructures such as integrated circuits is important for security and reliability assurance. Two scanning operations are required: ptychographic to recover the complex transmissivity of the specimen, and rotation of the specimen to acquire multiple projections covering the 3D spatial frequency domain. Two types of rotational scanning are possible: tomographic and laminographic. For flat, extended samples, for which the full 180° coverage is not possible, the latter is preferable because it provides better coverage of the 3D spatial frequency domain compared to limited-angle tomography. It is also because the amount of attenuation through the sample is approximately the same for all projections. However, both techniques are time consuming because of extensive acquisition and computation time. Here, we demonstrate the acceleration of ptycho-laminographic reconstruction of integrated circuits with 16 times fewer angular samples and 4.67 times faster computation by using a physics-regularized deep self-supervised learning architecture. We check the fidelity of our reconstruction against a densely sampled reconstruction that uses full scanning and no learning. As already reported elsewhere [ Opt. Express 28 , 12872 ( 2020 ) OPEXFF 1094-4087 10.1364/OE.379200 ], we observe improvement of reconstruction quality even over the densely sampled reconstruction, due to the ability of the self-supervised learning kernel to fill the missing cone.

47 OTHER INSTRUMENTATION↗

NuMI Beam Muon Monitor Data Analysis and Simulation for Improved Beam Monitoring

The NuMI muon monitors (MMs) are a very important diagnostic tool for monitoring the stability of the neutrino beam used by the NOvA experiment at Fermilab. The goal of our study is to maintain the quality of the MM signal and to establish the correlations between the neutrino and muon beam profile. This study could also inform the LBNF decision on the beam diagnostic tools. We report on the progress of beam scan data analysis (beam position, spot size, and magnetic horn current scan) and comparison with the simulation outcomes.

43 PARTICLE ACCELERATORS↗

Improvements in 500-kHz Ultrasonic Phased-Array Probe Designs for Evaluation of Thick Section Cast Austenitic Stainless Steel Piping Welds

PNNL has been studying and performing confirmatory research on the inspection of piping welds in coarse-grained steels for over 30 years. More recent efforts have been the application of low frequency phased array technology to this difficult to inspect material. The evolution of 500 kHz PA probes and the associated electronics and scanning protocol are documented in this report. The basis for the probe comparisons are responses from one mechanical fatigue crack and two thermal fatigue cracks in large-bore cast mockup specimens on loan from the Electric Power Research Institution. One of the most significant improvements was seen in the use of piezo-composite elements in the later two probes instead of the piezo-ceramic material used in the prototype array. This allowed a reduction in system gain of 30 dB and greatly reduced electronic noise. The latest probe had as much as a 5 dB increase in signal to noise, adding to its flaw discrimination capability. The system electronics for the latest probe were fully optimized for a 500 kHz center frequency, however significant improvements were not observed in the center frequency of the flaw responses. With improved scanner capabilities, smaller step sizes were used, allowing both line and raster data improvements to be made with the latest probe. The small step sizes produce high resolution images that improve flaw discrimination and, along with the increased signal-to-noise ratio inherent in the latest probe design, enhanced detection of the upper regions of the flaw make depth sizing more plausible. Finally, the physical sizes of the probes were progressively decreased allowing better access to the area of interest on specimens with weld crowns, and the latest probe was designed with non-integral wedges providing flexibility in focusing on different specimen geometries.

36 MATERIALS SCIENCE↗

Analysis of International Commodity Shipping Data and the Shipment of NORM to the United States

As part of the Spreader Bar Radiation Detector project, PNNL analyzed US import data shipped through US ports collected over the 12 months of 2006 (over 4.5 million containers). Using these data, we extracted a variety of distributions that are of interest to modelers and developers of active and passive detection systems used to 'scan' IMCCs for potential contraband. This report expands on some of the analysis presented in an earlier report from LLNL, by investigation the foreign port distribution of commodities shipped to the US. The majority of containers shipped to the United States are 40 ft containers (~70%); about 25% are 20 ft; and about 3.6% are 45 ft containers. A small fraction (<1%) of containers are of other more specialized sizes, and very few ports actually ship these unique size containers (a full distribution for all foreign ports is shown in Appendix A below). The primary foreign ports that ship the largest fraction of each container are shown in the table below. Given that 45 ft containers comprise 1 of out every 27 containers shipped to the US, and given the foreign ports from which they are shipped, they should not be ignored in screening; further testing and analysis of radiation measurements for national security with this size container is warranted. While a large amount of NORM is shipped in IMCCs, only a few specific commodities are shipped with enough frequency to present potential issues in screening IMCCs at ports. The majority of containers with NORM will contain fertilizers (5,700 containers), granite (59,000 containers), or ceramic (225,000 containers) materials. Fertilizers were generally shipping in either 20- or 40 ft containers with equal frequency. While granite is mostly shipped in 20 ft containers, ceramic materials can be shipped in either 20- or 40 ft containers. The size of container depended on the specific use of the ceramic or porcelain material. General construction ceramics (such as floor and roofing tiles) tend to be shipped in 20 ft containers. Consumer products made from ceramic materials (e.g., tableware, sinks, and toilets) are generally shipped in 40 ft containers. This distinct discrepancy is due in large part to the packaging of the commodity. Consumer products are generally shipped packed in a box loaded with Styrofoam or other packing material to protect the product from breakage. Construction ceramic materials are generally shipped in less packing material, many times consisting of only a cardboard or wooden box. Granite is almost always shipped in a 20 ft container, given its very high density.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanocrystalline SiC and Ti 3 SiC 2 Alloys for Reactor Materials: Thermal and Mechanical Properties

SiC-polymers (pure polycarbosilane and polycarbosilane filled with SiC-particles) are being combined with Si and TiC powders to create a new class of polymer-derived ceramics for consideration as advanced nuclear materials in a variety of applications. Compared to pure SiC these materials have increased fracture toughness with only slightly reduced thermal conductivity. Future work with carbon nanotube (CNT) mats will be introduced with the potential to increase the thermal conductivity and the fracture toughness. At present, this report documents the fabrication of a new class of monolithic polymer derived ceramics, SiC + SiC/Ti 3 SiC 2 dual phase materials. The fracture toughness of the dual phase material was measured to be significantly greater than Hexoloy SiC using indentation fracture toughness testing. However, thermal conductivity of the dual phase material was reduced compared to Hexoloy SiC, but was still appreciable, with conductivities in the range of 40 to 60 W/(m K). This report includes synthesis details, optical and scanning electron microscopy images, compositional data, fracture toughness, and thermal conductivity data.

36 MATERIALS SCIENCE↗

Microstructural Investigation of Precipitation Treated A709 Test Samples

This report presents the microstructural characterization using scanning transmission electron microscopy (STEM) of two creep-tested ESR1150-PT specimens, one short-term and one long-term. The results show that during creep testing, the microstructure of the A709 ESR1150-PT material continues to evolve as expected due to the synergistic effect of strain, temperature and time. Key features include dislocation forest and cell structures, precipitates on grain boundaries, precipitates randomly within grains, and precipitates associated with dislocations. In addition, the STEM study of one ESR1100-SA specimen that has been tested to rupture at a relatively low temperature (550°C) for a relatively long term (16226 h) is also presented. The results show that there is a high density of very fine nano precipitates form on dislocations.

36 MATERIALS SCIENCE↗

Imaging of Unstained DNA Origami Triangles with Electron Microscopy

Imaging of scaffolded DNA and DNA origami nanostructures has been dominated by atomic force microscopy of samples immobilized on bulk substrates. Less commonly used for DNA imaging are electron microscopy techniques, which are typically carried out either after negative staining of DNA or by direct imaging using a bright field cryo-TEM. Here, direct imaging of unstained DNA origami nanostructures on thin electron-transparent substrates utilizing high angular annular dark field scanning transmission electron microscopy )(HAADFSTEM) is reported. This approach establishes a simple method for depositing and imaging intact DNA triangles with mass-thickness contrast, sufficient to measure the scaffold-to-scaffold distances and the length of the triangle’s seam. The signal-to-noise ratio (SNR) of the DNA supported on amorphous carbon as a function of the carbon thickness is measured on three types of commercially available TEM grids to analyze the image resolution. This allows for an edge detection of ~1 nm height DNA triangles on carbon substrates as thick as ~25 nm. Additional observations on the effect on SNR with the imaging modes are discussed. The effect of cation concentration used for pre-treating the grid surface on the image resolution is also explored. Our work presents proof-of-concept results demonstrating that electron microscopy can be utilized to resolve key elements of the DNA origami triangle, without staining or employing exceedingly complicated preparation protocols.

Londono-Calderon, Alejandro↗

SACR ADVance 3-D Cartesian Cloud Cover (SACR-ADV-3D3C) product

SACR-ADV-3D3C remaps the outputs of SACRCORR for cross-wind range-height indicator (CW-RHI) scans to a Cartesian grid and reports reflectivity CFAD and best estimate domain averaged cloud fraction. The final output is a single NetCDF file containing all aforementioned corrected radar moments remapped on a 3-D Cartesian grid, the SACR reflectivity CFAD, a profile of best estimate cloud fraction, a profile of maximum observable x-domain size (xmax), a profile time to horizontal distance estimate and a profile of minimum observable reflectivity (dBZmin).

54 ENVIRONMENTAL SCIENCES↗

UCSD OSO-7 observations of the hard X-ray spectrum and variability of Centaurus A

Results are reported for four X-ray scans of the region containing Cen A. It is found that the X-ray source had a hard number spectrum (spectral index of -1.2) during these observations and that the intensity in the range from 10 to 100 keV apparently increased by 230% with no detectable change in spectral shape between two observations 210 days apart. Either a Compton-synchrotron mechanism or thermal bremsstrahlung at any temperature greater than 200 keV is suggested as the source of the X-rays. It is noted that the present observations, together with a similar detection of another galaxy, may establish a distinct class of extragalactic X-ray objects with flat and highly absorbed spectra.

Mushotzky, R. F.↗

Three-dimensional vector modeling and restoration of flat finite wave tank radiometric measurements

In this paper, a three-dimensional Fourier transform inversion method describing the interaction between water surface emitted radiation from a flat finite wave tank and antenna radiation characteristics is reported. The transform technique represents the scanning of the antenna mathematically as a correlation. Computation time is reduced by using the efficient and economical fast Fourier transform algorithm. To verify the inversion method, computations have been made and compared with known data and other available results. The technique has been used to restore data of the finite wave tank system and other available antenna temperature measurements made at the Cape Cod Canal. The restored brightness temperatures serve as better representations of the emitted radiation than the measured antenna temperatures.

Truman, W. M.↗

Saturn - UBV photoelectric pinhole scans of the disk

UBV photoelectric pinhole scans of Saturn's disk are reported. The data are interpreted by using elementary radiative-transfer models to describe scattering in the atmosphere above the visible haze layer. Limits are placed on the optical thickness of the region above the haze, and the results are discussed in terms of the probable structure of Saturn's upper atmosphere. It is shown that a model involving conservative Rayleigh scattering by hydrogen molecules above an opaque haze or cloud deck provides a satisfactory quantitative description of the scattering properties of Saturn's upper atmosphere.

Franz, O. G.↗

Near-infrared spectral imaging Michelson interferometer for astronomical applications

The design and operation of an imaging Michelson interferometer-spectrometer used for near-infrared (0.8 micron to 2.5 microns) spectral imaging are reported. The system employs a rapid scan interferometer modified for stable low resolution (250/cm) performance and a 42 element PbS linear detector array. A microcomputer system is described which provides data acquisition, coadding, and Fourier transformation for near real-time presentation of the spectra of all 42 scene elements. The electronic and mechanical designs are discussed and telescope performance data presented.

Wells, C. W.↗

The FORTRAN static source code analyzer program (SAP) system description

A source code analyzer program (SAP) designed to assist personnel in conducting studies of FORTRAN programs is described. The SAP scans FORTRAN source code and produces reports that present statistics and measures of statements and structures that make up a module. The processing performed by SAP and of the routines, COMMON blocks, and files used by SAP are described. The system generation procedure for SAP is also presented.

Decker, W.↗

The FORTRAN static source code analyzer program (SAP) user's guide, revision 1

The FORTRAN Static Source Code Analyzer Program (SAP) User's Guide (Revision 1) is presented. SAP is a software tool designed to assist Software Engineering Laboratory (SEL) personnel in conducting studies of FORTRAN programs. SAP scans FORTRAN source code and produces reports that present statistics and measures of statements and structures that make up a module. This document is a revision of the previous SAP user's guide, Computer Sciences Corporation document CSC/TM-78/6045. SAP Revision 1 is the result of program modifications to provide several new reports, additional complexity analysis, and recognition of all statements described in the FORTRAN 77 standard. This document provides instructions for operating SAP and contains information useful in interpreting SAP output.

Decker, W.↗

Atmospheric frontal zone studies

The research supported by this contract and directed Activities in the inversion and interpretation of data produced by the Nimbus-7 scanning multichannel microwave radiometer (SMMR) are reported. There were five principal subjects: (1) modeling of the emissivity of foam patches on the ocean surface; (2) inversion of radiometric data by a multidimensional algorithm; (3) an operational water vapor retrieval algorithm; (4) inference of Antarctic firm accumulation rates; and (5) inference of water vapor over the Arctic sea ice.

Staelin, D. H.↗

Observations of deep convection from an airborne high-frequency (92 and 183 GHz) passive microwave radiometer

Spencer et al. (1983) have reported that very low Nimbus-7 Scanning Multichannel Microwave Radiometer (SMMR) brightness temperatures at 37 GHz over land coincide with heavy thunderstorm rainfall, while Wilheit et al. (1982) used an aircraft-mounted radiometer operating at 92 and 183 GHz to observe convective precipitation associated with a tropical storm over the ocean. A scanning version of the instrument employed by Wilheit et al. is the Advanced Microwave Moisture Sounder (AMMS). The present paper has the objective to summarize the preliminary results of AMMS observations of convective raining clouds and to determine whether empirical relationships between rain rate and microwave brightness temperature, such as those developed for 37 GHz satellite data by Spencer et al., can be extended to higher microwave frequencies.

Hakkarinen, I. M.↗