Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

High energy X-ray characterization of the microstructure of PuGa alloy samples at macroscopic depths and non-ambient conditions

High energy (95 keV) X-rays were utilized to characterize the microstructure of eight PuGa alloy samples at room temperature and during cooling to ∼10 K. The samples had different Ga content (nominally 0-3.4 at.%), age, and history. A ninth sample, similarly characterized with neutron diffraction, was included to extend the Ga range to 7 at.%. The samples span the range from single phase α (monoclinic) to δ (face-centered cubic) PuGa, as well as a two-phase α′/δ sample. The crystallographic textures, phase fractions, lattice parameters and dislocation densities of each sample were evaluated through distinct analysis techniques. The textures of the samples were modest. In each case, the dislocation densities were relatively high, comparable to cold worked metals and metals exposed to similar radiation dose. At room temperature, the lattice parameters determined in the predominantly single-phase samples were larger than expected based on the nominal Ga concentration. The observed lattice thermal expansions of the single-phase δ samples to 10 K are self-consistent across the samples and consistent with previous measurements reported in the literature. Significantly larger thermal lattice strain is observed in the δ phase of the two-phase material due to mechanical constraint from the α′ phase, which has a three times larger thermal expansion and is much harder than the δ phase. In conclusion, the results demonstrate the unique value of high-energy X-rays for relatively routine microstructural characterization of Pu alloy samples.

36 MATERIALS SCIENCE↗

Faulting processes in active faults - Evidences from TCDP and SAFOD drill core samples

The microstructures, mineralogy and chemistry of representative samples collected from the cores of the San Andreas Fault drill hole (SAFOD) and the Taiwan Chelungpu-Fault Drilling project (TCDP) have been studied using optical microscopy, TEM, SEM, XRD and XRF analyses. SAFOD samples provide a transect across undeformed host rock, the fault damage zone and currently active deforming zones of the San Andreas Fault. TCDP samples are retrieved from the principal slip zone (PSZ) and from the surrounding damage zone of the Chelungpu Fault. Substantial differences exist in the clay mineralogy of SAFOD and TCDP fault gouge samples. Amorphous material has been observed in SAFOD as well as TCDP samples. In line with previous publications, we propose that melt, observed in TCDP black gouge samples, was produced by seismic slip (melt origin) whereas amorphous material in SAFOD samples was formed by comminution of grains (crush origin) rather than by melting. Dauphiné twins in quartz grains of SAFOD and TCDP samples may indicate high seismic stress. The differences in the crystallographic preferred orientation of calcite between SAFOD and TCDP samples are significant. Microstructures resulting from dissolution–precipitation processes were observed in both faults but are more frequently found in SAFOD samples than in TCDP fault rocks. As already described for many other fault zones clay-gouge fabrics are quite weak in SAFOD and TCDP samples. Clay-clast aggregates (CCAs), proposed to indicate frictional heating and thermal pressurization, occur in material taken from the PSZ of the Chelungpu Fault, as well as within and outside of the SAFOD deforming zones, indicating that these microstructures were formed over a wide range of slip rates.

Janssen, C.↗

A numerical and experimental approach to compare the effect of sample thickness in small in-situ SEM and large ex-situ tensile testing in Alloy 709

ASTM standards for tensile tests define specific sample size requirements regardless of grain size of the material. However, sample size requirements for testing should be considered in conjunction with the number of grains within its reduced cross-sectional area. This is particularly important for in-situ Scanning Electron Microscope (SEM) tensile tests, as they have to be conducted on smaller samples. In this study, a comprehensive experimental and numerical evaluation of the effect of specimen thickness (and the resulting number of grains within the cross-section) were conducted using in-situ SEM tensile test (on submillimeter thick samples) and ex-situ tensile tests (on samples of 0.68–5.9 mm thickness) and the results are compared with FEM simulations outcome. All tests were conducted at room temperature and the results are correlated to the number of grains within the thickness of specimens. The tensile test results indicated that even though the 0.2% proof stress and the tensile strength do not vary for the current range of thicknesses (with number of grains in the cross-section varying from 13 to 118), a difference in necking mechanism exists. Post tensile strength, thinner samples undergo more shear failure and diagonal localized necking whereas thicker samples experience more diffuse necking indicated by decreased area of shear failure at the edges and increased area of dimpled tensile failure at the center of the sample. Further, FEM results complement the experimental findings by showing the formation of conjugated localized shear bands on the upper and lower surface in the 0.68 mm thick sample and shear bands combining to form singular shear bands in thicker samples. These results also confirm the validity of the in-situ SEM tensile tests conducted on thinner samples as long as the required minimum number of grains exist within the cross-section.

36 MATERIALS SCIENCE↗

Combined Falling Drop/Open Port Sampling Interface System for Automated Flow Injection Mass Spectrometry

The aim of this work was to demonstrate and to evaluate the analytical performance of a combined falling drop/open port sampling interface (OPSI) system as a simple noncontact, no-carryover, automated system for flow injection analysis with mass spectrometry. The falling sample drops were introduced into the OPSI using a widely available autosampler platform utilizing low cost disposable pipet tips and conventional disposable microtiter well plates. The volume of the drops that fell onto the OPSI was in the 7–15 μL range with an injected sample volume of several hundred nanoliters. Sample drop height, positioning of the internal capillary on the sampling end of the probe, and carrier solvent flow rate were optimized for maximum signal. Sample throughput, signal reproducibility, matrix effects, and quantitative analysis capability of the system were established using the drug molecule propranolol and its isotope labeled internal standard in water, unprocessed river water and two commercially available buffer matrices. A sample-to-sample throughput of ~45 s with a ~4.5 s base-to-base flow injection peak profile was obtained in these experiments. In addition, quantitation with minimally processed rat plasma samples was demonstrated with three different statin drugs (atorvastatin, rosuvastatin, and fluvastatin). Direct characterization capability of unprocessed samples was demonstrated by the analysis of neat vegetable oils. Employing the autosampler system for spatially resolved liquid extraction surface sampling exemplified by the analysis of propranolol and its hydroxypropranolol glucuronide phase II metabolites from a rat thin tissue section was also illustrated.

47 OTHER INSTRUMENTATION↗

Efficient Sampling of Complex Interdependent and Multiplex Networks

Efficient sampling of interdependent and multiplex infrastructure networks is critical for effectively applying failure and recovery algorithms in real-world settings, as well as to generate property-preserving reduced-order graph-based ensembles that address topological uncertainties. In this paper, we first explore the performance, i.e. the success in preserving graph properties, of graph sampling algorithms for interdependent and multiplex networks with synthetic and real-world graphs. We simulate sampling algorithms under different parameter settings. These settings include probabilistic graph generators, coupling patterns, and various performance metrics. Our results show that while Random Node and Random Walk sampling algorithms perform best for interdependent networks, Random Edge and Forest Fire sampling algorithms perform best for multiplex networks. Second, we propose and implement a novel similarity-based sampling algorithm for multiplex networks that samples only log(N) number of layers of an N-layer multiplex network while yielding computational savings with performance guarantees. Experimental results show that similarity sampling outperforms complete sampling of all layers while decreasing performance costs from a linear scale to a logarithmic one. Our results also indicate that similarity-based sampling outperforms complete sampling and random selection in nearly all scenarios when tested with real-world data.

Subasi, Omer↗

Producing a BOSS CMASS sample with DES imaging

We present a sample of galaxies with the Dark Energy Survey (DES) photometry that replicates the properties of the BOSS CMASS sample. The CMASS galaxy sample has been well characterized by the Sloan Digital Sky Survey (SDSS) collaboration and was used to obtain the most powerful redshift-space galaxy clustering measurements to date. A joint analysis of redshift-space distortions (such as those probed by CMASS from SDSS) and a galaxy-galaxy lensing measurement for an equivalent sample from DES can provide powerful cosmological constraints. Unfortunately, the DES and SDSS-BOSS footprints have only minimal overlap, primarily on the celestial equator near the SDSS Stripe 82 region. Using this overlap, we build a robust Bayesian model to select CMASS-like galaxies in the remainder of the DES footprint. The newly defined DES-CMASS (DMASS) sample consists of 117,293 effective galaxies covering $1,244 {\rm deg}^2$. Through various validation tests, we show that the DMASS sample selected by this model matches well with the BOSS CMASS sample, specifically in the South Galactic cap (SGC) region that includes Stripe 82. Combining measurements of the angular correlation function and the clustering-z distribution of DMASS, we constrain the difference in mean galaxy bias and mean redshift between the BOSS CMASS and DMASS samples to be $\Delta b = 0.010^{+0.045}_{-0.052}$ and $\Delta z = \left( 3.46^{+5.48}_{-5.55} \right) \times 10^{-3}$ for the SGC portion of CMASS, and $\Delta b = 0.044^{+0.044}_{-0.043} $ and $\Delta z= ( 3.51^{+4.93}_{-5.91}) \times 10^{-3}$ for the full CMASS sample. These values indicate that the mean bias of galaxies and mean redshift in the DMASS sample is consistent with both CMASS samples within $1\sigma$.

79 ASTRONOMY AND ASTROPHYSICS↗

Tuning the spin dynamics and magnetic phase transitions of the Cantor alloy via composition and sample processing protocols: A muon spin relaxation study

CrMnFeCoNi, also called the Cantor alloy, is a well-known high-entropy alloy whose magnetic properties have recently become a focus of attention. Here, we present a detailed muon spin relaxation study of the influence of chemical composition and sample processing protocols on the magnetic phase transitions and spin dynamics of several different Cantor alloy samples. Specific samples studied include a pristine equiatomic sample, samples with deficient and excess Mn content, and equiatomic samples magnetized in a field of 9 T or plastically deformed in pressures up to 0.5 GPa. The results confirm the sensitive dependence of the transition temperature on composition and demonstrate that post-synthesis pressure treatments cause the transition to become significantly less homogeneous throughout the sample volume. In addition, we observe critical spin dynamics in the vicinity of the transition in all samples, reminiscent of canonical spin glasses and magnetic materials with ideal continuous phase transitions. Application of an external magnetic field suppresses the critical dynamics in the Mn-deficient sample, while the equiatomic and Mn-rich samples show more robust critical dynamics. The spin-flip thermal activation energy in the paramagnetic phase increases with Mn content, ranging from 3.1⁢(3) × 10 -21 J for 0% Mn to 1.2⁢(2) × 10 -20 J for 30% Mn content. These results shed light on critical magnetic behavior in environments of extreme chemical disorder and demonstrate the tunability of spin dynamics in the Cantor alloy via chemical composition and sample processing.

36 MATERIALS SCIENCE↗

Composite Sampling of a Bacillus anthracis Surrogate with Cellulose Sponge Surface Samplers from a Nonporous Surface

A series of experiments was conducted to explore the utility of composite-based collection of surface samples for the detection of a Bacillus anthracis surrogate using cellulose sponge samplers on a nonporous stainless steel surface. Two composite-based collection approaches were evaluated over a surface area of 3716 cm 2 (four separate 929 cm 2 areas), larger than the 645 cm 2 prescribed by the standard Centers for Disease Control (CDC) and Prevention cellulose sponge sampling protocol for use on nonporous surfaces. The CDC method was also compared to a modified protocol where only one surface of the sponge sampler was used for each of the four areas composited. Differences in collection efficiency compared to positive controls and the potential for contaminant transfer for each protocol were assessed. The impact of the loss of wetting buffer from the sponge sampler onto additional surface areas sampled was evaluated. Statistical tests of the results using ANOVA indicate that the collection of composite samples using the modified sampling protocol is comparable to the collection of composite samples using the standard CDC protocol (p = 0.261). Most of the surface-bound spores are collected on the first sampling pass, suggesting that multiple passes with the sponge sampler over the same surface may be unnecessary. The effect of moisture loss from the sponge sampler on collection efficiency was not significant (p = 0.720) for both methods. Contaminant transfer occurs with both sampling protocols, but the magnitude of transfer is significantly greater when using the standard protocol than when the modified protocol is used (p<0.001). The results of this study suggest that composite surface sampling, by either method presented here, could successfully be used to increase the surface area sampled per sponge sampler, resulting in reduced sampling times in the field and decreased laboratory processing cost and turn-around times.

59 BASIC BIOLOGICAL SCIENCES↗

Analyses and Comparison of Bulk and Coil Surface Samples from the DWPF Slurry Mix Evaporator

Sludge samples from the DWPF Slurry Mix Evaporator (SME) heating coil frame and coil surface were characterized to identify differences that might help identify heat transfer fouling materials. The SME steam coils have seen increased fouling leading to lower boil-up rates. Samples of the sludge were taken from the coil frame somewhat distant from the coil (bulk tank material) and from the coil surface (coil surface sample). The results of the analysis indicate the composition of the two SME samples are very similar with the exception that the coil surface sample shows ~5-10X higher mercury concentration than the bulk tank sample. Elemental analyses and x-ray diffraction results did not indicate notable differences between the two samples. The ICP-MS and Cs-137 data indicate no significant differences in the radionuclide composition of the two SME samples. Semi-volatile organic analysis revealed numerous organic molecules, these likely result from antifoaming additives. The compositions of the two SME samples also match well with the analyzed composition of the SME batch with the exception of significantly higher silicon, lithium, and boron content in the batch sample indicating the coil samples are deficient in frit relative to the SME batch composition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Variation in Uranium Isotopic Ratios 238 U/ 235 U and 234 U/ 238 U and 236 U/ 238 U in Water Samples Collected from Private Wells in the Española Basin, Santa Fe, New Mexico

This report presents uranium concentration and variation in uranium isotopic ratios 238 U/ 235 U and 234 U/ 238 U and 236 U/ 238 U in water samples collected from private wells in the Española basin in New Mexico. The document focuses specifically on analyzing variations in the uranium isotopic composition of the different water samples. The data presented in this report were obtained from water samples collected during the fall of 2012. A list of the different sampling locations as identified by their GPS coordinates is presented in Table 1 and represented on a map shown in Figure 1. Water temperature, conductivity, pH, and redox conditions (ORP) were also measured at the time of sampling and are also presented in Table 1. The pH of the samples ranged between 7.10 and 8.49, the temperature between 11.30 and 16.58 ˚C, and the ORP between -182 and 202 mV. The conductivity of the samples was between 454 µS·cm -1 and 1066 µS·cm -1 . The concentration of uranium in the samples varied widely and ranged between 11.5 and 776 µg/L. Uranium isotopic ratios conducted by Thermal Ionization Mass Spectrometry (TIMS) showed natural 238 U/ 235 U within analytical uncertainty. The water samples showed some variations in the isotopic ratios of 234 U/ 238 U, varying from atom ratios of 54.9×10 -6 to 226×10 -6 (activity ratios of 1.00 to 4.11), and indicating enrichment of 234 U in many of the water samples. These isotopic ratios are within the range observed in natural water. Such enrichments in 234 U in natural waters are common and typically attributed to natural processes. There was no detectable 236 U in any of the samples analyzed.

07 ISOTOPE AND RADIATION SOURCES↗

Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites

This plan incorporates U.S. Department of Energy (DOE) Office of Legacy Management (LM) standard operating procedures (SOPs) into environmental monitoring activities and will be implemented at all sites managed by LM. This document provides detailed procedures for the field sampling teams so that samples are collected in a consistent and technically defensible manner. Site-specific plans (e.g., long-term surveillance and maintenance plans, environmental monitoring plans) document background information and establish the basis for sampling and monitoring activities. Information will be included in site-specific tabbed sections to this plan, which identify sample locations, sample frequencies, types of samples, field measurements, and associated analytes for each site. Additionally, within each tabbed section, program directives will be included, when developed, to establish additional site-specific requirements to modify or clarify requirements in this plan as they apply to the corresponding site. A flowchart detailing project tasks required to accomplish routine sampling is displayed in Figure 1. LM environmental procedures are contained in the Environmental Procedures Catalog (LMS/PRO/S04325), which incorporates American Society for Testing and Materials (ASTM), DOE, and U.S. Environmental Protection Agency (EPA) guidance. Specific procedures used for groundwater and surface water monitoring are included in Appendix A. If other environmental media are monitored, SOPs used for air, soil/sediment, and biota monitoring can be found in the site-specific tabbed sections in Appendix D or in site-specific documents. The procedures in the Environmental Procedures Catalog are intended as general guidance and require additional detail from planning documents in order to be complete; the following sections fulfill that function and specify additional procedural requirements to form SOPs. Routine revision of this Sampling and Analysis Plan will be conducted annually at the beginning of each fiscal year when attachments in Appendix D, including program directives and sampling location/analytical tables, will be reviewed by project personnel and updated. The sampling location/analytical tables in Appendix D, however, may have interim updates according to project direction that are not reflected in this plan. Deviations from location/analytical tables in Appendix D prior to sampling will be documented in project correspondence (e.g., startup letters). If significant changes to other aspects of this plan are required before the annual update, then the plan will be revised as needed.

54 ENVIRONMENTAL SCIENCES↗

Fast Approximate Union Volume in High Dimensions with Line Samples

The classical problem of calculating the volume of the union of d-dimensional balls is known as "Union Volume." We present line-sampling approximation algorithms for Union Volume. Our methods may be extended to other Boolean operations, such as setminus; or to other shapes, such as hyper-rectangles. The deterministic, exact approaches for Union Volume do not scale well to high dimensions. However, we adapt several of these exact approaches to approximation algorithms based on sampling. We perform local sampling within each ball using lines. We have several variations, depending on how the overlapping volume is partitioned, and depending on whether radial, axis-aligned, or other line patterns are used. Our variations fall within the family of Monte Carlo sampling, and hence have about the same theoretical convergence rate, 1 /$\sqrt{M}$, where M is the number of samples. In our limited experiments, line-sampling proved more accurate per unit work than point samples, because a line sample provides more information, and the analytic equation for a sphere makes the calculation almost as fast. We performed a limited empirical study of the efficiency of these variations. We suggest a more extensive study for future work. We speculate that different ball arrangements, differentiated by the distribution of overlaps in terms of volume and degree, will benefit the most from patterns of line samples that preferentially capture those overlaps. Acknowledgement We thank Karl Bringman for explaining his BF-ApproxUnion (ApproxUnion) algorithm [3] to us. We thank Josiah Manson for pointing out that spoke darts oversample the center and we might get a better answer by uniform sampling. We thank Vijay Natarajan for suggesting random chord sampling. The authors are grateful to Brian Adams, Keith Dalbey, and Vicente Romero for useful technical discussions. This work was sponsored by the Laboratory Directed Research and Development (LDRD) Program at Sandia National Laboratories. This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Advanced Scientific Computing Research (ASCR), Applied Mathematics Program. Sandia National Laboratories is a multi-mission laboratory managed and operated by National Technology and Engineering Solutions of Sandia, LLC., a wholly owned subsidiary of Honeywell International, Inc., for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-NA0003525.

97 MATHEMATICS AND COMPUTING↗

Analysis of Tank 38H (HTF-38-18-78, -79) and Tank 43H (HTF-43-18-80, -81, -83) Samples for Support of the Enrichment Control and Corrosion Control Programs

SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. Compared with recent samples, the surface and sub-surface samples from Tank 38H show much lower concentrations of most species analyzed except for silicon. The Tank 38H samples show stratification in the tank with the concentration of species in the surface sample being much lower than in the sub-surface sample and both samples being much lower than recent results. The Tank 43H surface and two sub-surface samples generally showed consistent results across the three samples and compare well with recent analyses. The lowest sub-surface sample from Tank 43H contained slightly higher concentrations of uranium and plutonium likely due to the presence of a small amount of dark sludge solids in the sample.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Tank 30H (HTF-30-18-96, -97), Tank 32H (HTF-32-18-98, -99), and Tank 37H (HTF-37-18-100, -101) Samples for Support of the Evaporator Feed Qualification and Corrosion Control Programs for the 3H-Evaporator

SRNL analyzed samples from Tank 30H, Tank 32H, and Tank 37H to support the Evaporator Feed Qualification and Corrosion Control Programs for the 3H-Evaporator system. The six samples from Tanks 30H, 32H, and 37H all contain highly concentrated salt solutions with sodium concentrations ranging from 11.8 M to 15.7 M. The samples from Tank 30H show somewhat higher concentrations of the major cations and anions in the sub-surface sample than the surface sample indicating some stratification within the tank. The two Tank 32H samples show similar concentrations of the major anions and cations between the surface and sub-surface samples. The sub-surface sample from Tank 37H shows higher concentrations for most species than the surface sample indicating some stratification within this tank as well. For all six samples, the sum of the major cations versus the sum of the major anions shows a difference of <10% providing an indication of good data quality. The VDS and surface samples from Tank 30H, Tank 32H, and Tank 37H all show silicon concentrations below 30 mg/L except for the Tank 30H VDS with a concentration of 87 mg/L.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solvent Hold Tank Sample Results for MCU-18-301- 303 (July 2018), MCU-18-357-359-360 (August 2018), and MCU-18-402-410 (September 2018) (Quarterly Report)

A trend summary of three Solvent Hold Tank (SHT) monthly samples; MCU-18-301-302-303, MCU-18- 357-359-360 and MCU-18-402-410 are reported. Most of the conclusions are based on the September SHT sample (MCU-18-402-410). Analyses of the September SHT sample (MCU-18-402-410) indicated that the Modifier (Cs-7SB) and the extractant (MaxCalix) concentrations were below their nominal recommended concentrations (169,000 mg/L and 46,400 mg/L respectively) by 5% and 8% respectively. The suppressor (N,N’,N”–tris(3,7-dimethyloctyl)guanidine or TiDG) concentration has decreased since the April 2018 measurement (Modular Caustic-Side Solvent Extraction Unit or MCU resumed processing radioactive salt solution from May through August 2018) to 241 mg/L, well below the minimum recommended concentration (479 mg/L). The apparent “downwards” trends observed in the TiDG, MaxCalix, and Modifier measurements are consistent with the startup (or Proficiency Runs) of MCU on May 22, 2018; new levels are consistent with the concentrations observed when MCU was fully operational in 2016. This analysis confirms the Isopar™ L addition to the solvent on July 2 and August 9, 2018. This analysis also indicates the solvent did require a trim addition. Based on the current monthly sample, the concentrations of Isopar™ L, MaxCalix, and Modifier are sufficient for continuing operation but are expected to decrease with time. The TiDG concentration was below its recommended level. Periodic characterization and trimming additions to the solvent are recommended. The Semi-Volatile Organic Analysis (SVOA) did not detect any impurities. However, the Fourier Transform Hydrogen Nuclear Magnetic Resonance (FT-HNMR) analysis detected a low concentration of sec-butyl phenol (SBP) at levels of a few ppm. The impurity concentration was highest in the July sample and consistently detected in the August and September samples (but always a few ppm or less). The source of this impurity is due to the degradation of the Modifier. Another impurity observed in the samples was mercury. Based on the September SHT sample, up to 17 ± 3 micrograms of mercury per mL of solvent was detected (the average of the Direct Mercury Analysis (DMA) and X-Ray Fluorescence (XRF) methods). The higher mercury concentration in the solvent (as determined in the last three monthly samples) is possibly due to the higher mercury concentration in Salt Batches 9 and 10 (SB 10 was recently added to Tank 49H in March 2017). The gamma concentration (~2.3E5 dpm/mL) measured in the September SHT samples was consistent with previous values observed when MCU was fully operational (for example, between December 2016 and January 2017) and it was lower than the April SHT measurement. The “dip” in the gamma measurement for the May 2018 SHT sample was due to Isopar™ L addition to MCU during April and May 2018. The laboratory will continue to monitor the quality of the solvent for any new impurities or degradation of the solvent components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Validation of pooling strategies of clinical COVID-19 samples for more efficient diagnostic testing

Pooling of COVID-19 clinical samples can offer significant reduction in reagents, time, and labor needed to test large numbers of clinical samples. Especially for testing asymptomatic and return-towork/ school cases, where the prevalence of COVID-19 may be relatively low, large groups of clinical samples can be classified as negative with a single test, with no need to test every sample individually. LANL has performed validation for two different pooling strategies to assess diagnostic assay sensitivity in pooled samples compared to the clinical positive sample alone. (1) Pooling study - Determine diagnostic assay sensitivity in pooled samples with ratios of 1:5, 1:10, 1:20, and 1:30 positive to negative clinical samples. (2) Reloading study - Determine diagnostic assay sensitivity in reloading of multiple clinical samples through a Qiagen column in 5x, 10, and 20x sample volumes (1 positive plus 4, 9, and 19 negative samples).

59 BASIC BIOLOGICAL SCIENCES↗

Soil Sample Plan in Support of the Site 300 Explosives Waste Treatment Facility Ecological Risk Assessment Pursuant to the Hazardous Waste Facility Permit, Part V, Special Condition #14 a-f. August 2020

The Department of Toxic Substances Control issued the Final Hazardous Waste Facility Permit to Lawrence Livermore National Laboratory, Site 300 in 2017. As part of the continual process to ensure waste treatment emissions are not impacting ecological receptors, LLNL analyzed soil samples in the vicinity of the Explosive Waste Treatment Facility (EWTF) Burn Units (i.e., Burn Cage and Burn Pan) and the Detonation Pad. Soil samples were analyzed by EPA Solid Waste 846 Methods for furans, explosives, metals, and semivolatile compounds. In all samples, furans, explosives, and semi-volatile organic compounds were not detected. Metals were detected at concentrations below background levels. This soil sample plan will sample the same four downwind areas of the Burn Units and the same downwind areas of the Detonation, as well as including four new sample locations. The four new locations will be located to the northeast and southwest of the Burn Units and Detonation (as shown in Figure 3). The constituents to be analyzed are in Tables 2 and 3. Perchlorate was not identified as a constituent of concern in the 2007 Soil Sampling Plan. However, for this plan, all soil samples will be analyzed for perchlorate. After completion of the sampling event, a soil sample report will be submitted to DTSC in accordance with requirements specified in the Hazardous Waste Facility Permit, Part V, Special Conditions 16 a-f. This proposed soil sampling plan will be fully implemented no later than one year after receiving DTSC approval, in accordance with the Hazardous Waste Facility Permit, Part V, Special Condition 15.

54 ENVIRONMENTAL SCIENCES↗

Analysis of Tank 38H (HTF-38-23-95, -96) and Tank 43H (HTF-43-23-93, -94) Samples for Support of the Enrichment Control and Corrosion Control Programs

Savannah River National Laboratory analyzed samples from Tank 38H and Tank 43H to support Enrichment Control Program (ECP) and Corrosion Control Program (CCP). The results indicate the concentrations of most soluble species in the Tank 38H surface sample increased significantly from the previous Tank 38H surface sample. The current Tank 38H subsurface sample shows similar Na, free hydroxide, and anions versus the previous subsurface sample. However, the 38H subsurface sample shows higher concentrations of Al, Ca, Fe, Mn, and Si vs. the previous Tank 38H subsurface sample. The current Tank 38H subsurface sample contained visible sludge solids in excess of the previous sample based on visual appearance. Weight percent solids measurements indicate presence of 3.0 ± 0.1 wt.% insoluble solids in the Tank 38H subsurface sample. The significant differences in the concentrations of major components between the Tank 38H surface and subsurface samples indicate significant stratification of solution species between these two locations within the Tank 38H. Savannah River Mission Completion (SRMC) personnel indicated that there were no tank-to-tank transfers into Tank 38H since early January 2023 and the 2H (16H) Evaporator was shut down on 3/26/2023 and has not operated since that time. There have been many pumped non-waste transfers of water from the H-Area diversion box 7 (HDB-7) sump into Tank 38 since the 3/26/2023 date.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗