A standard load center converter power supply

A modular multiple-output Standard Load Center Converter (SLCC), developed for a wide range of space applications, is discussed, including its specifications, characteristics, electrical and mechanical designs, advanced heat removal techniques, and unique packaging concept. The converter can be tailored to meet specific requirements by simple selection of the proper transformer and feedback resistor networks.

Graves, J. R.↗

Radiation hardened PMOS process with ion implanted threshold adjust

By including specific process modifications the effect of ion implantation on radiation hardness can be minimized and radiation hard ion implanted MOS circuits can be fabricated. The experimental procedure followed was to examine key processing steps (with respect to radiation hardness) on ion-implanted individual PMOS transistors. The individual transistors were evaluated by continuously monitoring the threshold voltage as the transistors were being irradiated. By comparing runs it was possible to deduce what is considered a radiation hard ion implanted process. Tests with a complex LSI PMOS IC processor chip containing over 2000 transistors and resistors were also conducted

Jhabvala, M.↗

Improved power factor controller

Power dissipation is ac induction motor is reduced by circuit that lowers applied voltage when motor is idling or only lightly loaded. Timing voltages in phase with motor current are sensed a cross gate-controlled semiconductor whitch with motor, rather than across high-power resistor, as in earlier version.

Nola, F. J.↗

Signal conditioner for nickel temperature sensors

Simple circuit conditions output of 50 ohm sensor for readout on straingage recorder. It consists of resistors, switch, and "matching" network. Device saves time and reduced instrumentation costs when strain and temperature are measured in same setup.

Walker, R. R.↗

Low-resistance continuity tester

IC printed-circuit board tester measures resistance as low as 0.1 ohm but uses little power. Two 4.7 kilohm resistors and connected transistors prevent current flow through operational amplifier until probe circuit is complete, eliminating need for on/off switch. Zener diode in series with amplifier output prevents audio oscillator operation until output has sufficient amplitude. Circuit utilizes 741 operational amplifier on 11.2 volt battery or lower voltage amplifiers.

Reasoner, R. B.↗

Distributed-switch Dicke radiometers

A radiometer on an orbiting spacecraft is described which derives high spatial resolution information from terrestrial and atmospheric regions. The N elements or subapertures on the spacecraft transduce electromagnetic energy into electric signals. Many or all of the elements are simultaneously illuminated by electromagnetic energy radiated from the same region. Identical, parallel processing channels are responsive to the N elements. Each of the channels includes a variable gain amplifier responsive to the signal transduced by its corresponding array elements. The gain of each amplifier is controlled as a function of the output difference when the channel is connected periodically to each of a pair of Dicke noise sources, such as resistors maintained at predetermined temperatures.

Levis, C. A.↗

Lithium battery discharge tests

The long term discharge of a variety of lithium cells was characterized and the susceptibility of the cells to chemical variation during the slow discharge was tested. A shunt resistor was set across the terminals to monitor the voltage as a function of time. Failures were identified by premature voltage drops.

Johnson, C. J.↗

RCA Satcom: In-orbit experience

The system characteristics of the Satcom batteries and Satcom power system are briefly discussed. Performance of the nickel cadmium 22 cell batteries onboard in parallel with independent redundant charges providing the charge rates is reported. Performance onboard reconditioning with individual cell bypasses with 1 ohm resistors is discussed for the F-1 and F-2 spacecraft.

Debaylo, P. W.↗

Design and test of the Near Infrared Mapping Spectrometer /NIMS/ focal plane for the Galileo Jupiter Orbiter mission

A Near Infrared Mapping Spectrometer (NIMS) will fly past Jupiter on the Galileo spacecraft in 1982. The infrared detector assembly (focal plane) used in the NIMS instrument is to be passively cooled to 80 K by radiation into space. The focal plane contains 15 InSb and two silicon detectors, each with an associated dual J-FET preamp and feedback resistor. Preliminary fabrication and test experience will be described for an experimental five-channel hybrid detector assembly. Measurements of spectral noise density along with a plasma cleaning technique will also be described. The final NIMS focal plane will contain much of the design experience gained from the experimental hybrid detector assembly.

Bailey, G.↗

Simple Magnetometer for Autopilots

Simple, low-cost magnetometer is suitable for heading-reference applications in autopilots and other directional control systems. Sensing element utilizes commercially available transformer core; and supporting electronics consist of one transistor, two readily-available integrated-circuit chips, and associated resistors and capacitors.

Garner, H. D.↗

Study of digital charge coupled devices

Charge coupled devices represent unique usage of the metal oxide semiconductor concept. These devices can sample an AC signal at the input, transfer charge proportional to this signal through the CCD shift register and then provide an output of the same frequency and shape as the input. The delay time between input and output is controlled by the CCD operating frequency and the number of stages in the shift resistor. This work is a reliability evaluation of the buried channel and surface channel CCD technologies. The constructions are analyzed, failure modes are described, and test results are reported.

Wilson, D. D.↗

Redundant operation of counter modules

A technique for the redundant operation of counter modules is described. Redundant operation is maintained by detecting the zero state of each counter and clearing the other to that state, thus periodically resynchronizing the counters, and obtaining an output from both counters through AC coupled diode-OR gates. Redundant operation of counter flip flops is maintained in a similar manner, and synchronous operation of redundant squarewave clock generators of the feedback type is effected by connecting together the feedback inputs of the squarewave generators through a coupling resistor, and obtaining an output from both generators through AC coupled diode-OR gates.

Nagano, S.↗

The SMART MIL-STD-1553 bus adapter hardware manual

The SMART Multiplexer Interface Adapter, (SMIA) a complete system interface for message structure of the MIL-STD-1553, is described. It provides buffering and storage for transmitted and received data and handles all the necessary handshaking to interface between parallel 8-bit data bus and a MIL-STD serial bit stream. The bus adapter is configured as either a bus controller of a remote terminal interface. It is coupled directly to the multiplex bus, or stub coupled through an additional isolation transformer located at the connection point. Fault isolation resistors provide short circuit protection.

Ton, T. T.↗

Vacuum applications of metal foams

Several vacuum applications of copper foams in the density range 2-5% and pore sizes of 0.5-0.7 mm are discussed, such as a foreline hydrocarbon trap in a mechanical vacuum pump, a molecular-flow resistor, a diffuser, and a water injector. Other suggested applications include the use of foam copper in the form of an externally heated plug to remove traces of oxygen from inert gases bled into a vacuum system through a stainless steel line and the use of the porous surface for minimizing release of secondary electrons from electrodes in the path of charged particle beams.

Kendall, B. R. F.↗

A study of low-noise preamplifier systems for use with room temperature mercuric iodide /HgI2/ X-ray detectors

An analysis of different preamplification systems for use with room temperature mercuric iodide X-ray detectors has been performed. Resistor-, drain-, and light-feedback preamplifiers have been studied. Energy resolution values of 295 eV (FWHM) for an Fe-55 source (5.9 keV) and 225 eV (FWHM) for a pulser have been obtained with both the detector and the input FET at room temperature using a pulsed-light feedback preamplifier. Improvement in energy resolution by cooling the input FET using a small Peltier element has been discussed.

Iwanczyk, J. S.↗

Voltage Regulator for a dc-to-dc Converter

New voltage regulator isolates signals from power-switching converter without use of complex circuitry or optical couplers. Only addition is extra secondary winding on existing interstage transformer. Error signals shortcircuit new winding and inhibit converter action. Resistor in series with primary winding limits short-circuit current to prevent damage to circuit components. Extra transformer winding eliminates need for isolation components.

Mclyman, C. W.↗

Passive components for high temperature operation

The development of resistors, capacitors, and interconnect metalizations utilizing a low pressure chemical vapor deposition (LPCVD) process is described. The LPCVD process allows the passive components to be fabricated at temperatures higher than their highest operating temperatures. The deposition of thin films by LPCVD is accomplished by reacting one or more gases on the surface of a heated substrate. The substrates to be coated are placed on a graphite susceptor and then loaded into the center of a quartz reaction tube. The RF power is applied to the coil on the outside of the reaction tube which in turn is coupled into the graphite susceptor causing it to heat. Pressures of several torr or less are typical, with carrier flow rates of 0.1 to 2.0 liters/min. Nitrogen, hydrogen, and helium are typical carrier gases. These are controlled with mass flow controllers and the pressure is continuously monitored with a capacitive manometer. Materials selection and device testing are also discussed.

Raymond, L. S.↗

Direct current ballast circuit for metal halide lamp

A direct current ballast circuit for a two electrode metal halide lamp is described. Said direct current ballast circuit includes a low voltage DC input and a high frequency power amplifier and power transformer for developing a high voltage output. The output voltage is rectified by diodes and filtered by inductor and capacitor to provide a regulated DC output through commutating diodes to one terminal of the lamp at the output terminal. A feedback path from the output of the filter capacitor through the bias resistor to power the high frequency circuit which includes the power amplifier and the power transformer for sustaining circuit operations during low voltage transients on the input DC supply is described. A current sensor connected to the output of the lamp through terminal for stabilizing lamp current following breakdown of the lamp is described.