Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “range measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Kinetic simulation of a 50 mTorr capacitively coupled argon discharge over a range of frequencies and comparison to experiments

The effect of driving frequency in the range of 13.56–73 MHz on electron energy distribution and electron heating modes in a 50 mTorr capacitively coupled argon plasma discharge is studied using 1D-3V particle-in-cell simulations. Calculated electron energy probability functions exhibit three distinct “temperatures” for low-, mid-, and high-energy electrons at all the studied driving frequencies. When compared to published experimental data, the calculated probability functions show a reasonable agreement for the energy range resolved in the measurements (about 2–10 eV). Discrepancies due to limitations in experimental energy resolution outside this range lead to differences between computational and experimental values of the electron number density determined from the distribution functions, and the predicted effective electron temperature is within 25% of experimental values. The impedance of the discharge is interpreted in terms of a homogeneous equivalent circuit model, and the driving frequency dependence of the inferred combined sheath thickness is found to obey a known, theoretically derived, power law. The average power transferred from the field to the electrons (electron heating) is computed, and a region of negative heating near the sheath edge, particularly at higher driving frequencies, is identified. Analysis of the electron momentum equation shows that electron inertia, which on temporal averaging would be zero in a linear regime, is responsible for negative values of power deposition near the sheath edge at high driving frequencies due to the highly nonlinear behavior of the discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Line identification of boron and nitrogen emissions in EUV and VUV wavelength ranges in the impurity powder dropping experiments of LHD and its application to spectroscopic diagnostics

An impurity powder dropper was installed in the 21st campaign of the Large Helical Device experiment (Oct. 2019–Feb. 2020) under a collaboration between the National Institute for Fusion Science and the Princeton Plasma Physics Laboratory for the purposes of real-time wall conditioning and edge plasma control. In order to assess the effective injection of the impurity powders, spectroscopic diagnostics were applied to observe line emission from the injected impurity. Therefore, extreme-ultraviolet (EUV) and vacuum-ultraviolet (VUV) emission spectra were analyzed to summarize observable impurity lines with B and BN powder injection. Emission lines released from B and N ions were identified in the EUV wavelength range of 5–300 Å measured using two grazing incidence flat-field EUV spectrometers and in the VUV wavelength range of 300–2400 Å measured using three normal incidence 20 cm VUV spectrometers. BI–BV and NIII–NVII emission lines were identified in the discharges with the B and BN powder injection, respectively. Useful B and N emission lines which have large intensities and are isolated from other lines were successfully identified as follows: BI (1825.89, 1826.40) Å (blended), BII 1362.46 Å, BIII (677.00, 677.14, 677.16) Å (blended), BIV 60.31 Å, BV 48.59 Å, NIII (989.79, 991.51, 991.58) Å (blended), NIV 765.15 Å, NV (209.27, 209.31) Å (blended), NVI 1896.80 Å, and NVII 24.78 Å. Applications of the line identifications to the advanced spectroscopic diagnostics were demonstrated, such as the vertical profile measurements for the BV and NVII lines using a space-resolved EUV spectrometer and the ion temperature measurement for the BII line using a normal incidence 3 m VUV spectrometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MARSAME Radiological Release Report for Metal Items from TA 53, Set 20

EPC-ES has evaluated the survey results for metal items from the Los Alamos Neutron Science Center (LANSCE) and found that the metal items described in Table 1 of this report (identified by RP Tracking Numbers) meet the criteria for unrestricted release under DOE Order 458.1 Radiation Protection of the Public and the Environment (DOE 2020) and can be recycled. This conclusion is based on the known history of the metal items and on radiation survey data (see the completed RP-Form-031 LANSCE Metals Clearance Log for each item). None of the items in this report are located within radiological areas. Therefore, the items are considered unencumbered and are not subject to the moratorium suspension on metal recycling from Department of Energy facilities. Additionally, LANL has determined that there is no practical opportunity for internal DOE reuse or recycling of this metal. Process knowledge indicates that these metal items were unlikely to ever be in direct contact with the beam and thus are unlikely to have become activated. Surface contamination measurements (both total and removable) showed either no detectable radioactivity or activity levels within the range of background. All measurements for volumetric contamination were indistinguishable from background based on calculated decision limits. Additionally, all gamma isotopic surveys conducted for defense-in-depth showed no identifiable gamma radiation from beam activation.

54 ENVIRONMENTAL SCIENCES↗

MARSAME Radiological Release Report for Metal Items from Technical Area 53, Set 26

Environmental Protection and Compliance, Environmental Stewardship Group (EPC-ES) has evaluated the survey results for metal items from the Los Alamos Neutron Science Center (LANSCE) at Technical Area 53 (TA-53) and found that the metal items described in Table 1 of this report (identified by Radiation Protection [RP] Tracking Numbers) meet the criteria for unrestricted release under Department of Energy (DOE) Order 458.1 Chg 4, Radiation Protection of the Public and the Environment (DOE 2020) and can be recycled. This conclusion is based on the known history of the metal items and radiation survey data. None of the items in this report are located within radiological areas. Therefore, the items are considered unencumbered and are not subject to the moratorium suspension on metal recycling from DOE facilities. Additionally, Los Alamos National Laboratory (LANL) has determined that there is no practical opportunity for internal DOE reuse of this metal. Process knowledge indicates that these metal items were unlikely to ever be in direct contact with the beam and thus are unlikely to have become activated. Surface contamination measurements (both total and removable) showed either no detectable radioactivity or activity levels within the range of background. All measurements for volumetric contamination were indistinguishable from background based on calculated decision limits. Additionally, all gamma isotopic surveys conducted for defense-in depth showed no identifiable gamma radiation from beam activation.

54 ENVIRONMENTAL SCIENCES↗

MARSAME Radiological Release Report for Metal Items from Technical Area 53, Set 28

Environmental Protection and Compliance, Environmental Stewardship Group (EPC-ES) has evaluated the survey results for metal items from the Los Alamos Neutron Science Center (LANSCE) at Technical Area 53 (TA-53) and found that the metal items described in Table 1 of this report (identified by Radiation Protection [RP] Tracking Numbers) meet the criteria for unrestricted release under Department of Energy (DOE) Order 458.1 Chg 4, Radiation Protection of the Public and the Environment (DOE 2020) and can be recycled. This conclusion is based on the known history of the metal items and radiation survey data (see the completed RP-Form-031 LANSCE Metals Clearance Log [LANL 2021a] for each item in Attachment 1). Process knowledge indicates that items were released from radiological areas, including radiation areas, prior to the implementation of the 2000 metals moratorium. Therefore, the items are considered unencumbered and are not subject to the moratorium suspension on metal recycling from DOE facilities. Additionally, Los Alamos National Laboratory (LANL) has determined that there is no practical opportunity for internal DOE reuse of this metal. Process knowledge indicates that these metal items were unlikely to ever be in direct contact with the beam and thus are unlikely to have become activated. Surface contamination measurements (both total and removable) showed either no detectable radioactivity or activity levels within the range of background. All measurements for volumetric contamination were indistinguishable from background based on calculated decision limits. Additionally, all gamma isotopic surveys conducted for defense-in depth showed no identifiable gamma radiation from beam activation.

61 RADIATION PROTECTION AND DOSIMETRY↗

MARSAME Radiological Release Report for Metal Items from TA 53, Set 22

EPC-ES has evaluated the survey results for metal items from the Los Alamos Neutron Science Center (LANSCE) and found that the metal items described in Table 1 of this report (identified by RP Tracking Numbers) meet the criteria for unrestricted release under DOE Order458.1 Radiation Protection of the Public and the Environment (DOE 2020) and can be recycled. This conclusion is based on the known history of the metal items and on radiation survey data (see the completed RP-Form-031 LANSCE Metals Clearance Log [LANL 2021a] for each item). None of the items in this report are located within radiological areas. Therefore, the items are considered unencumbered and are not subject to the moratorium suspension on metal recycling from Department of Energy facilities. Additionally, LANL has determined that there is no practical opportunity for internal DOE reuse or recycling of this metal. Process knowledge indicates that these metal items were unlikely to ever bein direct contact with the beam and thus are unlikely to have become activated. Surface contamination measurements (both total and removable) showed either no detectable radioactivity or activity levels within the range of background. All measurements for volumetric contamination were indistinguishable from background based on calculated decision limits. Additionally, all gamma isotopic surveys conducted for defense-in-depth showed no identifiable gamma radiation from beam activation.

36 MATERIALS SCIENCE↗

Electron and photon reconstruction and identification with the CMS experiment at the CERN LHC

The performance is presented of the reconstruction and identification algorithms for electrons and photons with the CMS experiment at the LHC. The reported results are based on proton-proton collision data collected at a center-of-mass energy of 13 TeV and recorded in 2016–2018, corresponding to an integrated luminosity of 136 fb^-1. Results obtained from lead-lead collision data collected at √(sNN)=5.02 TeV are also presented. Innovative techniques are used to reconstruct the electron and photon signals in the detector and to optimize the energy resolution. Events with electrons and photons in the final state are used to measure the energy resolution and energy scale uncertainty in the recorded events. The measured energy resolution for electrons produced in Z boson decays in proton-proton collision data ranges from 2 to 5%, depending on electron pseudorapidity and energy loss through bremsstrahlung in the detector material. The energy scale in the same range of energies is measured with an uncertainty smaller than 0.1 (0.3)% in the barrel (endcap) region in proton-proton collisions and better than 1 (3)% in the barrel (endcap) region in heavy ion collisions. The timing resolution for electrons from Z boson decays with the full 2016–2018 proton-proton collision data set is measured to be 200 ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Physically motivated analytical expression for the temperature dependence of the zero-field splitting of the nitrogen-vacancy center in diamond

The temperature dependence of the zero-field splitting (ZFS) between the | $m_s$ = 0 $\rangle$ and | $m_s$ = ±1 $\rangle$ levels of the nitrogen-vacancy (NV) center's electronic ground-state spin triplet can be used as a robust nanoscale thermometer in a broad range of environments. However, despite numerous measurements of this dependence in different temperature ranges, to our knowledge no analytical expression has been put forward that captures the scaling of the ZFS of the NV center across all relevant temperatures. Here we present a simple, analytical, and physically motivated expression for the temperature dependence of the NV center's ZFS that matches all experimental observations, in which the ZFS shifts in proportion to the occupation numbers of two representative phonon modes. In contrast to prior models our expression does not diverge outside the regions of fitting. In conclusion, we show that our model quantitatively matches experimental measurements of the ZFS from 15 to 500 K in single NV centers in ultrapure bulk diamond, and we compare our model and measurements to prior models and experimental data.

36 MATERIALS SCIENCE↗

Summary of the Postirradiation Examination of the First Samples from a MiniFuel Irradiation

An overview of postirradiation examination results for uranium nitride kernels and uranium nitride coated particles irradiated in the High Flux Isotope Reactor are presented. This is the first postirradiation examination of the MiniFuel irradiation vehicle that was recently developed to rapidly screen different nuclear fuel concepts. Observations on fission gas release, irradiation conditions and microstructure of the irradiated fuel show good fuel performance at the low burnup achieved in this initial irradiation. The burnup measured by mass spectrometry ranged from 5.9 to 10 MWd/kgU as was achieved after only 68 effective full power days of irradiation. Results from silicon carbide thermometry measurements further benchmarked the MiniFuel irradiation vehicle and indicated fuel was irradiated at temperatures ranging from 410-460°C. Extensive microstructural characterization on the irradiated fuel was performed and no significant irradiation induced changes were observed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Overview of the front-end electronics of CMS HGCal - including readout and powering

The end-cap calorimeters of CMS will be upgraded to a single High Granularity Calorimeter (HG-Cal) for the HL-LHC, including both silicon sensors and scintillator tiles with on-tile SiPMs as active elements. The readout of the active elements is performed by an ASIC (HGCROC in 130 nm CMOS technology) that measures the amplitude and arrival time of the signals. The amplitude is measured over a large dynamic range to allow calibration with single particles and the measurement of TeV showers. The time of arrival of high-energy showers will be measured with a precision of around 30 ps. A second pair of “concentrator” ASICs - ECON-T and ECON-D - takes the data from the HGCROC channels and packages them for transmission via optical links to the off-detector electronics. The ECON-T transmits trigger data at 40 MHz, to form part of the level-1 trigger. The ECON-D transmits concentrated data packets at up to 1 MHz, upon reception of a level-1 trigger signal. In addition to these ASICs, HGCal will use modified versions of common HL-LHC electronics developments, for the power chain and the optical control and readout. The dense nature of the HGCal provides additional challenges for the electronic boards and cabling. In this proceedings the overall HGCal front electronics scheme, including the latest performance of the HGCROC and ECON ASICs is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Iridate Li8IrO 6 : An Antiferromagnetic Insulator

In this work, a polycrystalline iridate Li 8 IrO 6 material was prepared via heating Li 2 O and IrO 2 starting materials in a sealed quartz tube at 650 °C for 48 h. The structure was determined from Rietveld refinement of room-temperature powder neutron diffraction data. Li 8 IrO 6 adopts the nonpolar space group $R\bar{3}$ with Li atoms occupying the tetrahedral and octahedral sites, which is supported by the electron diffraction and solid-state 7Li NMR. This results in a crystal structure consisting of LiO 4 tetrahedral layers alternating with mixed IrO 6 and LiO 6 octahedral layers along the crystallographic c -axis. The +4 oxidation state of Ir 4+ was confirmed by near-edge X-ray absorption spectroscopy. An in situ synchrotron X-ray diffraction study of Li 8 IrO 6 indicates that the sample is stable up to 1000 °C and exhibits no structural transitions. Magnetic measurements suggest long-range antiferromagnetic ordering with a Néel temperature (TN) of 4 K, which is corroborated by heat capacity measurements. The localized effective moment $μ_{\text{eff}}$ (Ir) = 1.73 $μ_{\text{B}}$ and insulating character indicate that Li 8 IrO 6 is a correlated insulator. First-principles calculations support the nonpolar crystal structure and reveal the insulating behavior both in paramagnetic and antiferromagnetic states.

36 MATERIALS SCIENCE↗

Thermophysical Property Measurements of NaCl-UCl3

Describe the research (summary of Scope of Work and principal objectives of the CRADA): Argonne produced and measured thermochemical and thermophysical properties of eutectic NaCl-UCl 3 salt at several temperatures in the range of interest. (Note measurements made with UCl 3 instead of PuCl 3 at participant’s request.)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Kinetic Modeling and Experimental Studies of Capacitively Coupled Macro- and Microplasmas at Microwave Frequencies

The effect of driving frequency in the range of 13.56 MHz to 73 MHz on electron energy distribution and electron heating modes in a 50 mTorr capacitively coupled argon plasma discharge is studied using 1D-3V particle-in-cell simulations. Calculated electron energy probability functions exhibit three distinct temperatures for low-, mid-, and high-energy electrons at all the studied driving frequencies. When compared to published experimental data, the calculated probability functions show a reasonable agreement for the energy range resolved in the measurements (about 2 eV to 10 eV). Discrepancies due to limitations in experimental energy resolution outside this range lead to differences between computational and experimental values of the electron number density determined from the distribution functions, and the predicted effective electron temperature is within 25 % of experimental values. The impedance of the discharge is interpreted in terms of a homogeneous equivalent circuit model and the driving frequency dependence of the inferred combined sheath thickness is found to obey a known, theoretically-derived, power law. The average power transferred from the field to the electrons (electron heating) is computed, and a region of negative heating near the sheath edge, particularly at higher driving frequencies, is identified. Analysis of the electron momentum equation shows that electron inertia, which on temporal averaging would be zero in a linear regime, is responsible for negative values of power deposition near the sheath edge at high driving frequencies due to the highly nonlinear behavior of the discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct Measurement of the Nickel Spectrum in Cosmic Rays in the Energy Range from 8.8 GeV/$\mathcal{n}$ to 240 GeV/$\mathcal{n}$ with CALET on the International Space Station

The relative abundance of cosmic ray nickel nuclei with respect to iron is by far larger than for all other transiron elements; therefore it provides a favorable opportunity for a low background measurement of its spectrum. Since nickel, as well as iron, is one of the most stable nuclei, the nickel energy spectrum and its relative abundance with respect to iron provide important information to estimate the abundances at the cosmic ray source and to model the Galactic propagation of heavy nuclei. However, only a few direct measurements of cosmic-ray nickel at energy larger than ~ 3 GeV/n are available at present in the literature, and they are affected by strong limitations in both energy reach and statistics. In this Letter, we present a measurement of the differential energy spectrum of nickel in the energy range from 8.8 to 240 GeV/n , carried out with unprecedented precision by the Calorimetric Electron Telescope (CALET) in operation on the International Space Station since 2015. The CALET instrument can identify individual nuclear species via a measurement of their electric charge with a dynamic range extending far beyond iron (up to atomic number Z = 40 ). The particle’s energy is measured by a homogeneous calorimeter (1.2 proton interaction lengths, 27 radiation lengths) preceded by a thin imaging section (3 radiation lengths) providing tracking and energy sampling. This Letter follows our previous measurement of the iron spectrum [O. Adriani et al. (CALET Collaboration), Phys. Rev. Lett. 126, 241101 (2021).], and it extends our investigation on the energy dependence of the spectral index of heavy elements. It reports the analysis of nickel data collected from November 2015 to May 2021 and a detailed assessment of the systematic uncertainties. In the region from 20 to 240 GeV/n our present data are compatible within the errors with a single power law with spectral index -2.51 ± 0.07 .

79 ASTRONOMY AND ASTROPHYSICS↗

TRANSLATE - a Monte Carlo simulation of electron transport in liquid argon

Here, the microphysics of electron and photon propagation in liquid argon is a key component of detector design and calibrations needed to construct and perform measurements within a wide range of particle physics experiments. As experiments grow in scale and complexity, and as the precision of their intended measurements increases, the development of tools to investigate important microphysics effects impacting such detectors becomes necessary. In this paper we present a new time-domain Monte Carlo simulation of electron transport in liquid argon. The simulation models the TRANSport in Liquid Argon of near-Thermal Electrons (TRANSLATE) with the aim of providing a multi-purpose software package for the study and optimization of detector environments, with a particular focus on ongoing and next generation liquid argon neutrino experiments utilizing the time projection chamber technology. TRANSLATE builds on previous work of Wojcik and Tachiya, amongst others, introducing additional processes, including ionization, thus modeling the full range of drift electron scattering interactions. The simulation is validated by benchmarking its performance with swarm parameters from data collected in experimental setups operating in gas and liquid.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino, Rafael [Unlisted]↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino Meza, Rafael [Unlisted, US; Fermilab]↗