UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence L - Raw Data

Sequence L: Step AOA, Parked (P) This sequence was designed to quantify the 3-D blade static angle-of-attack response in the absence of rotational influences by varying the blade pitch angle. This test sequence used an upwind, rigid turbine with a 0° cone angle. Wind speeds of 20 m/s and 30 m/s were used, and all data were collected at a yaw angle of 0°. The rotor was parked with the instrumented blade fixed at 0° azimuth, and the rotor lock was installed (see Appendix A). Blade and probe pressure measurements were collected. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to -99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. The blade pitch angle ramped continuously at 0.18°/s over a wide range of increasing and decreasing pitch angles. A step sequence was also performed. The blade pitch was stepped 5°, the flow was allowed to stabilize, and the pitch angle was held for 8 seconds. Then the pitch angle step was repeated. Again, a wide range of pitch angles was obtained, both increasing and decreasing. The file lengths for this sequence varied from 5 to 10 minutes, depending on the pitch angle range. The file name convention used the initial letter L followed by two digits specifying wind speed, followed by 00 for yaw angle, followed by RU, RD, or ST, followed by the repetition digit. The angle-of-attack motion was differentiated by RU (ramp up), RD (ramp down), and ST (step down, then step up). This sequence is related to sequences K and R.

17 WIND ENERGY↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence R - Raw Data

Sequence R: Step AOA, No Probes (P) This sequence was designed to quantify the effect of the five-hole probes on the 3-D blade static angle-of-attack response in the presence of rotational influences by repeating Sequence K without five-hole probes. This test sequence used an upwind, rigid turbine with a 0° cone angle. The wind speeds ranged from 6 m/s to 20 m/s, and data were collected at yaw angles of 0° and 30°. The rotor rotated at 72 RPM. Blade pressure measurements were collected. The five-hole probes were removed and the plugs were installed. Plastic tape 0.03-mm-thick was used to smooth the interface between the plugs and the blade. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to –99999.99 Nm. The teeter link load cell was pre-tensioned to 40,000 N. During post-processing, the probe channels were set to read –99999.99. The blade pitch angle ramped continuously at 0.18°/s over a wide range of increasing and decreasing pitch angles. A step sequence was also performed. The blade pitch was stepped 5°; the flow was allowed to stabilize; and the pitch angle was held for 5 seconds. Then the pitch angle step was repeated. Again, a wide range of pitch angles was obtained, both increasing and decreasing. The file lengths for this sequence varied from 96 seconds to 6 minutes, depending on the pitch angle range. Some short points were collected at 0° yaw and 3° pitch to ascertain the functionality of the instrumentation and repeatability over time. The file name convention used the initial letter R, followed by two digits specifying wind speed, followed by two digits for yaw angle, followed by RU, RD, or ST, followed by the repetition digit. The angle of attack motion was differentiated by RU (ramp up), RD (ramp down), and ST (step down, then step up). This sequence is related to Sequences K and L.

17 WIND ENERGY↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis – Simulated Wind

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production using a single, simulated wind turbine. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel Hydrogen . While the unit supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. For the simulated wind energy profiles, NLR used OpenFAST to simulate a 3.4-MW International Energy Agency (IEA) reference wind turbine. The hour-long wind energy profiles varied over wind turbulence intensity (Class A or Class C) and average wind speed (5, 7, or 9 m/s). To match the power limits of the 1.25-MW electrolyzer and 3.4-MW IEA wind turbine most effectively and to maximize the efficiency of hydrogen production at a given average wind speed, the profiles were sometimes scaled by two times. This means that, in some cases, the experimental setup assumed two 1.25-MW electrolyzers were coupled with the wind turbine, representing a total maximum electrolysis load of 2.5 MW. Finally, NLR experimented with two settings for the electrolyzer power supply minimum and maximum current ramp rates (gain and slew): 200 and 400 amperes per second. The simulated profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wind turbine electrolysis experiment and is formatted as follows: {technology}-{average wind speed}-{turbulence class}_{number of 1.25 MW electrolyzers connected}-{electrolyzer ramp rate in amperes/second} For instance, “windIEA3.4-5ms-C_2-400.zip” represents the hour-long experiment using the IEA 3.4-MW turbine, subjected to an average wind speed of 5 m/s and Class C wind turbulence, and connected to two 1.25-MW electrolyzers with the power supply set to a maximum current ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wind turbine power. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30 minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all simulated wind experiments combined into one dataset labeled "combined_wind_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis .

08 HYDROGEN↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Wave

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production using a single, simulated wave energy conversion device. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel Hydrogen. While the unit supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. For the wave energy, NLR used a wave energy converter model from PacWave. These devices can be equipped with accumulators and pressure relief values to smooth the power output by storing and releasing hydraulic energy. Using a peak power output of 10 MW, the model created two 25-minute profiles: one with and one without the accumulators and pressure relief valves. To down select the profile data from the native resolution of 20 Hz to 1 Hz, NLR took the mean of every 20 data points. NLR experimented with two simulated wave energy power plants: one that peaks at 10 MW, and one that peaks at 5 MW. These profiles were scaled for the physical 1.25 MW electrolyzer by multiplying the original profiles by one eighth and one quarter, respectively. The first profile matches the capacity rating of eight of the 1.25 MW electrolyzers, while the second matches four electrolyzers. Finally, NLR experimented with two settings for the electrolyzer power supply minimum and maximum current ramp rates (gain and slew): 200 and 400 amperes per second. The simulated profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wave electrolysis experiment and is formatted as follows: {technology}-{accumulator?}_{number of 1.25 MW electrolyzers connected}-{electrolyzer ramp rate in amperes/second} For instance, “wavePacWave-Noacc_4-400.zip” represents the 25 minute-long experiment using the PacWave’s wave energy converter model, equipped with no accumulator, connected to four 1.25-MW electrolyzers with their power supplies set to a maximum current ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. An experiment, labeled “characterization_200.zip”, demonstrates the MC250 electrolyzer steady-state response with 30 minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all wave profiles combined into one dataset labeled "combined_wave_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis.

08 HYDROGEN↗

Mach stem structure in exothermic systems.

Incident waves having grossly similar characteristics were obtained by passing a shock wave over a ramp mounted on the divergent part of a convergent-divergent nozzle. The range of triple point parameters in both the naturally occurring detonative Mach stems and those generated in the ramp experiments compared favorably, but some differences were observed in the triple point trajectories and the decay rates of the lead waves. Whereas the lead waves in detonations have been found to decay at rates between those of planar and cylindrical blast waves, the decay observed in the ramp experiments was more like that of planar blast waves. The dominant factor in determining a triple point trajectory was found to be the orientation of the lead wave at the triple point. Comparison of reactive and nonreactive cases indicated a faster rate of decay of the lead wave and a steeper triple point trajectory for the reactive cases than for the nonreactive ones. Also, a sensitivity of the trajectory to initial pressure was observed in the former, although none was present in the nonreactive cases.

Liaugminas, R.↗

Structure of the quasi-perpendicular laminar bow shock

It was found that low solar wind parameters M (less than or around 2.5) and beta (much less than 1) and high angles to the local shock normal, theta (greater than or around 65 deg), produced oblique laminar shock profiles as expected from theory, with marginal or vanishing upstream standing whistlers probably damped by acoustic or other plasma wave instabilities. The whistler mode appeared to dominate the electromagnetic spectrum. The laminar shock ramp thickness was several hundred kilometers and equal to (2-4)c/omega-pi. Composition of the shock as an accumulation of near-standing waves and an evidently reproducible varying flux pattern was discernible. Electron thermalization occurred early in, or just before, the magnetic ramp, while proton thermalization appeared to occur later in the ramp. Instantaneous shock velocities derived from the standing whistler wavelength were consistent with average velocities derived from the elapsed time estimates and were as high as 200 km/sec.

Greenstadt, E. W.↗

Performance at Mach 3.52 of a Mach 2.5 all external-compression, two dimensional inlet

A quick-look test was conducted in the 10- by 10-foot supersonic wind tunnel to provide some qualitative information on operating a low Mach number design inlet in a highly oversped condition. The model which is a two-dimensional, three-ramp, all-external-compression inlet designed to match a J-85 turbojet engine at Mach 2.5 was run at Mach 3.52 and zero angle-of-attack and yaw. Results are presented showing the effect of external ramp angle combinations, diffuser ramp position, and amount of bleed.

Cubbison, R. W.↗

Improvements in rocket engine nozzle and high altitude plume computations

The characteristics of rocket exhaust flow fields are very complex, and many phenomena are involved. Previously, it was necessary to use a multitude of codes to treat a nozzle/plume flow in detail. In connection with both computational and economic standpoints, however, it is desirable to have a single code which can treat all the dominant phenomena in a rocket nozzle/plume flow field. The present investigation has the objective to describe a nozzle plume flowfield code which has capabilities that do not presently exist in a single computer code. The RAMP code considered by Penny et al. (1976) was used as a basis in the development of the new code. The basic RAMP employs modular construction and provides a two-phase, reacting gas, supersonic inviscid nozzle/plume solution. Other capabilities needed, which in most cases already exist in other computer codes, were incorporated into the RAMP code to enhance its usefulness. Attention is given to results of plume calculations for bipropellant and solid propellant motors.

Smith, S. D.↗

Modelling of TGS growth in space

Attention is called to the necessity of programming the temperature downward in order to maintain a constant growth rate in the absence of convection. Trial and error numerical computations are performed to find the first approximation for the required isothermal dissolution period, linear ramp, and polynomial temperature variation period. The linear ramp rate is limited by the specified maximum temperature gradient. The isothermal dissolution turns out to be unnecessary. The linear ramp must be stopped before the polynomial period is begun in order to avoid overshooting the specified maximum growth rate. After a few hours, the temperature profile approaches steady-state behavior.

Liu, L. C.↗

Transient flow combustion

Non-steady combustion problems can result from engine sources such as accelerations, decelerations, nozzle adjustments, augmentor ignition, and air perturbations into and out of the compressor. Also non-steady combustion can be generated internally from combustion instability or self-induced oscillations. A premixed-prevaporized combustor would be particularly sensitive to flow transients because of its susceptability to flashback-autoignition and blowout. An experimental program, the Transient Flow Combustion Study is in progress to study the effects of air and fuel flow transients on a premixed-prevaporized combustor. Preliminary tests performed at an inlet air temperature of 600 K, a reference velocity of 30 m/s, and a pressure of 700 kPa. The airflow was reduced to 1/3 of its original value in a 40 ms ramp before flashback occurred. Ramping the airflow up has shown that blowout is more sensitive than flashback to flow transients. Blowout occurred with a 25 percent increase in airflow (at a constant fuel-air ratio) in a 20 ms ramp. Combustion resonance was found at some conditions and may be important in determining the effects of flow transients.

Tacina, R. R.↗

Variable frequency VLF signals in the magnetosphere Associated phenomena and plasma diagnostics

Coherent variable-frequency signals (ramps) extending from 1 to 8 kHz, injected into the magnetosphere from Siple Station, Antarctica (L=4.3), exhibit upper and lower cutoffs when received at the conjugate station, Roberval, Quebec. Ramp group delay measurements and ionospheric sounding data are used to determine the cold plasma density and L shell of the propagation path. Relationships among f, df/dt, and the 'phase equator' for gyroresonance are calculated using second-order resonance equations generalized to relativistic electrons. The concept thereby introduced is used to develop a diagnostic technique which, for an assumed g(alpha)(v exp -n) electron distribution, provides an estimate of the energy dependence n. Additional aspects of the magnetospheric response to ramp injection, such as emission triggering, curvature due to dispersion, and amplitude saturation, are discussed.

Carlson, C. R.↗

ROM-Based Plan-Position-Indicator Sweep Driver

Circuit produces PPI display on conventional X-Y oscilloscope. Circuit requires three inputs. First is once-per-scan pulse to synchronize display to north, relative heading, or another reference direction. Second is once-per-degree-of-rotation pulse to advance sweep rotation. Third input is normal sweep ramp. Duration of ramp corresponds to maximum displayed range. Changing ramp duration, while holding its peak amplitude constant, changes maximum displayed range. Conventional methods to accomplish this task use mechanically-driven deflection coils or mechanically-driven sine and cosine potentiometers, requiring mechanical preventive maintenance plus dedicated display indicator. New method displays radar sweep on any conventional storage oscilloscope.

Franke, J. M.↗

The relationship of extensional and compressional tectonics to a Precambrian fracture system in the eastern overthrust belt, USA

The central and southern Appalachians have a long history of interrelated extensional and compressional tectonics. It is proposed that each episode was controlled by a reactivation of a fracture system in the Precambrian basement. Proprietary seismic-reflection profiles show a system of down-to-the-east Precambrian extensional faults. When under renewed extension, these faults produce features such as the western border faults of Mesozoic basins, and when under compression, probably produce tectonic ramps in the overlying sedimentary cover rocks as well as the spatially and genetically related Alleghenian folds. This system, which parallels the Appalachian trend, is cut by a system of cross-strike hinge or scissors faults that have probable strike-slip movements. Reactivation of this cross-strike system appears to have produced lateral ramps that connect decollements at different stratigraphic levels and caused abrupt changes in fold wavelength along strikes. Continued reactivation of this cross-strike system is suggested by east-west border faults and Precambrian highs between Mesozoic basins. The present activity of this system is suggested by the fact that more than 35% of recent earthquakes are coincident with cross-strike faults and lateral ramps.

Pohn, H.↗

Theoretical Investigation of Submerged Inlets at Low Speeds

The general characteristics of the flow field in a submerged air inlet are investigated by theoretical, wind-tunnel, and visual-flow studies. Equations are developed for calculating the laminar and turbulent boundary-layer growth along the ramp floor for parallel, divergent, and convergent ramp walls, and a general equation is derived relating the boundary-layer pressure losses to the boundary-layer thickness. It is demonstrated that the growth of the boundary layer on the floor of the divergent-ramp inlet is retarded and that a vortex pair is generated in such an inlet. Functional relationships are established between the pressure losses in the vortices and the geometry of the inlet. A general discussion of the boundary layer and vortex formations is included, in which variations of the various losses and of the incremental external drag with mass-flow ratio are considered. Effects of compressibility are also discussed.

Sacks, Alvin H.↗

The dynamics and control of fluctuating pressure loads in the reattachment region of a supersonic free shear layer

The primary aim is to investigate the mechanisms which cause the unsteady wall-pressure fluctuations in shock wave turbulent shear layer interactions. The secondary aim is to find means to reduce the magnitude of the fluctuating pressure loads by controlling the unsteady shock motion. The particular flow proposed for study is the unsteady shock wave interaction formed in the reattachment zone of a separated supersonic flow. Similar flows are encountered in many practical situations, and they are associated with high levels of fluctuating wall pressure. Wall pressure fluctuations were measured in the reattachment region of the supersonic free shear layer. The free shear layer was formed by the separation of a Mach 2.9 turbulent boundary layer from a backward facing step. Reattachment occurred on a 20 deg ramp. By adjusting the position of the ramp, the base pressure was set equal to the freestream pressure, and the free shear layer formed in the absence of a separation shock. An array of flush-mounted, miniature, high-frequency pressure transducers was used to make multichannel measurements of the fluctuating wall pressure in the vicinity of the reattachment region. Contrary to previous observations of this flow, the reattachment region was found to be highly unsteady, and the pressure fluctuations were found to be significant. The overall behavior of the wall pressure loading is similar in scale and magnitude to the unsteadiness of the wall pressure field in compression ramp flows at the same Mach number. Rayleigh scattering was used to visualize the instantaneous shock structure in the streamwise and spanwise direction. Spanwise wrinkles on the order of half the boundary layer thickness were observed.

Smits, A. J.↗

Measured forces and moments on a delta wing during pitch-up

A series of low-speed wind tunnel tests on a 70-deg, sharp, leading-edge delta wing undergoing ramp pitching motion of high amplitude were performed to investigate the aerodynamic forces and moments. Forces and moments were obtained from a six-component interanl balance. Large amplitude oscillatory motion was produced by sinusoidally oscillating the model over a range of reduced frequencies. Ramp motion was produced by pitching the model through a half cycle of sinusoidal motion at a root chord Reynolds number of 1.54 million. The effect of ramp and oscillatory motions on the forces and moments are almost identical at matched pitch rates. Pitch rate had strong effect on the magnitude of the aerodynamic forces and moments. Upon completion of the model motion, some time is required for the forces and moments to decay to their static values. This convergence of the dynamic values to the static ones was a function of the pitch rate.

Bragg, M. B.↗

Investigation of several passive and active methods for turbulent flow separation control

Relative performance of several passive and active methods for controlling two-dimensional turbulent separated flow associated with a curved backward-facing ramp were investigated at low speeds. Surface static pressure measurement and oil flow visualization results indicate that submerged vortex generators, vortex generator jets, elongated arches at +-alpha, and large-eddy breakup devices at +-alpha placed near the baseline separation location reduce flow separation and increase pressure recovery. Spanwise cylinders reduce flow separation but decrease pressure recovery downstream. Arches with alpha = 0 deg, Helmholtz resonators, and Viets' fluidic flappers examined so far have no significant effect in reducing separation. Wall cooling computation indicates that separation delay on a partially cooled ramp is nearly the same as on a fully-cooled ramp while minimizing the frictional drag increase associated with the wall cooling process.

Lin, J. C.↗

A computational investigation of flow losses in a supersonic combustor

This computational investigation provides a detailed comparative study of both non-reacting and reacting supersonic combustor flow-fields and attendant flow losses. Three different injection configurations in the same combustor are examined; a swept-sided ramp with base hydrogen injection, a straight ramp with base hydrogen injection and a thirty-degree downstream directed wall jet. Detailed comparisons are made with available reacting experimental data for the swept and the unswept ramps. A seven reaction, seven species reaction model as well as a global (one reaction) model are used for all three reacting cases. Relative performance (as measured by thrust) of all cases are described. Details of the flow, mixing, and combustion processes are discussed.

Riggins, David W.↗