Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Surface purity control during XMASS detector refurbishment

The XMASS project aims at detecting dark matter, pp and {sup 7}Be solar neutrinos, and neutrino less double beta decay using large volume of pure liquid xenon. The first physics target of the XMASS project is to detect dark matter with 835 kg liquid xenon. After the commissioning runs, XMASS detector was refurbished to minimize the background contribution mainly from PMT sealing material and we restarted data taking in November 2013. We report how we control surface purity, especially how we prevent radon daughter accumulation on the detector copper surface, during XMASS detector refurbishment. The result and future plan of XMASS are also reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of an underground HPGe array facility for ultra low radioactivity measurements

Low Level Counting techniques using low background facilities are continuously under development to increase the possible sensitivity needed for rare physics events experiments. The CUP (Center for Underground Physics) group of IBS is developing, in collaboration with Canberra, a ultra low background instrument composed of two arrays facing each other with 7 HPGe detectors each. The low radioactive background of each detector has been evaluated and improved by the material selection of the detector components. Samples of all the building materials have been provided by the manufacturer and the contaminations had been measured using an optimized low background 100% HPGe with a dedicated shielding. The evaluation of the intrinsic background has been performed using MonteCarlo simulations and considering the contribution of each material with the measured contamination. To further reduce the background, the instrument will be placed in the new underground laboratory at YangYang exploiting the 700m mountain coverage and radon-free air supplying system. The array has been designed to perform various Ultra Low background measurements; the sensitivity we are expecting will allow not only low level measurements of Ra and Th contaminations in Copper or other usually pure materials, but also the search for rare decays. In particular some possible candidates and configurations to detect the 0νECEC (for example {sup 106}Cd and {sup 156}Dy) and rare β decays ({sup 96}Zr, {sup 180m}Ta , etc ) are under study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analytico-numerical tool for studying the influence of the inhomogeneity on the behavior of cracked magneto-electro-elastic materials

Functionally graded materials (FGM) are extensively used in modern industry. They are composite materials with continuously varying properties in one or more special dimensions, according to the specific purpose. In view of the wide range of applications of FGM, stress analysis is important for their structural integrity and reliable service life. In this study we will consider functionally graded magneto-electro-elastic materials with one or more cracks subjected to SH waves. We assume that the material properties vary in one and the same way, described by an inhomogeneity function. The boundary value problem is reduced to a system of integro-differential equations based on the existence of fundamental solutions. Different inhomogeneity classes are used to obtain a wave equation with constant coefficients. Radon transform is applied to derive the fundamental solution in a closed form. Program code in FORTRAN 77 is developed and validated using available examples from literature. Simulations show the dependence of stress field concentration near the crack tips on the frequency of the applied time-harmonic load for different types of material inhomogeneity.

42 ENGINEERING↗

Lithosphere-Surfacesphere–Atmosphere-Ionosphere coupling model for Vrancea seismic zone in Romania

This paper presents a complex multidisciplinary approach concept to explain the nature of short-term earthquake precursors observed in land surface, atmosphere, ionosphere and magnetosphere for strong intermediate depth earthquakes recorded in Vrancea region in Romania. A developed Lithosphere-Surfacesphere-Atmosphere-Ionosphere (LSAI) coupling model can explain most of these presignals as a synergy between different anomalies of geophysical/geochemical parameters. These anomalies prior to medium to strong earthquakes are attributed to the thermodynamic, degassing and ionization processes in the Earth-Atmosphere system and micro-fracturing in the rocks especially along area’s active faults. The main outcome of this paper is an unified concept for systematic validation of different types of earthquake precursors of which Land Surface Temperature (LST), outgoing Long wave Radiation (OLR), Surface Latent Heat Flux (SLHF), Air Temperature (AT), radon gas concentration, ionospheric Total Electron Content (TEC) are the most reliable parameters within the chain of the processes described by LSAI model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Algebraic reconstruction and postprocessing in one-step diffuse optical tomography

The photon average trajectory method is considered, which is used as an approximate method of diffuse optical tomography and is based on the solution of the Radon-like trajectory integral equation. A system of linear algebraic equations describing a discrete model of object reconstruction is once inverted by using a modified multiplicative algebraic technique. The blurring of diffusion tomograms is eliminated by using space-varying restoration and methods of nonlinear colour interpretation of data. The optical models of the breast tissue in the form of rectangular scattering objects with circular absorbing inhomogeneities are reconstructed within the framework of the numerical experiment from optical projections simulated for time-domain measurement technique. It is shown that the quality of diffusion tomograms reconstructed by this method is close to that of tomograms reconstructed by using Newton-like multistep algorithms, while the computational time is much shorter. (special issue devoted to application of laser technologies in biophotonics and biomedical studies)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IONOSPHERIC POWER-SPECTRUM TOMOGRAPHY IN RADIO INTERFEROMETRY

A tomographic method is described to quantify the three-dimensional power spectrum of the ionospheric electron-density fluctuations based on radio-interferometric observations by a two-dimensional planar array. The method is valid for the first-order Born approximation and might be applicable in correcting observed visibilities for phase variations due to the imprint of the full three-dimensional ionosphere. It is shown that the ionospheric electron-density distribution is not the primary structure to model in interferometry, but rather its autocorrelation function or equivalently its power spectrum. An exact mathematical expression is derived that provides the three-dimensional power spectrum of the ionospheric electron-density fluctuations directly from a rescaled scattered intensity field and an incident intensity field convolved with a complex unit phasor that depends on the w-term and is defined on the full sky pupil plane. In the limit of a small field of view, the method reduces to the single phase-screen approximation. Tomographic self-calibration can become important in high-dynamic range observations at low radio frequencies with wide-field antenna interferometers because a three-dimensional ionosphere causes a spatially varying convolution of the sky, whereas a single phase screen results in a spatially invariant convolution. A thick ionosphere can therefore not be approximated by a single phase screen without introducing errors in the calibration process. By applying a Radon projection and the Fourier projection-slice theorem, it is shown that the phase-screen approach in three dimensions is identical to the tomographic method. Finally, we suggest that residual speckle can cause a diffuse intensity halo around sources due to uncorrectable ionospheric phase fluctuations in the short integrations, which could pose a fundamental limit on the dynamic range in long-integration images.

79 ASTRONOMY AND ASTROPHYSICS↗

Measuring temperature-dependent propagating disturbances in coronal fan loops using multiple SDO/AIA channels and the surfing transform technique

A set of co-aligned high-resolution images from the Atmospheric Imaging Assembly (AIA) on board the Solar Dynamics Observatory is used to investigate propagating disturbances (PDs) in warm fan loops at the periphery of a non-flaring active region NOAA AR 11082. To measure PD speeds at multiple coronal temperatures, a new data analysis methodology is proposed enabling a quantitative description of subvisual coronal motions with low signal-to-noise ratios of the order of 0.1%. The technique operates with a set of one-dimensional 'surfing' signals extracted from position-time plots of several AIA channels through a modified version of Radon transform. The signals are used to evaluate a two-dimensional power spectral density distribution in the frequency-velocity space that exhibits a resonance in the presence of quasi-periodic PDs. By applying this analysis to the same fan loop structures observed in several AIA channels, we found that the traveling velocity of PDs increases with the temperature of the coronal plasma following the square-root dependence predicted for slow mode magneto-acoustic waves which seem to be the dominating wave mode in the loop structures studied. This result extends recent observations by Kiddie et al. to a more general class of fan loop system not associated with sunspots and demonstrating consistent slow mode activity in up to four AIA channels.

79 ASTRONOMY AND ASTROPHYSICS↗

Towards optimal sensor placement for inverse problems in spaces of measures

The objective of this work is to quantify the reconstruction error in sparse inverse problems with measures and stochastic noise, motivated by optimal sensor placement. To be useful in this context, the error quantities must be explicit in the sensor configuration and robust with respect to the source, yet relatively easy to compute in practice, compared to a direct evaluation of the error by a large number of samples. In particular, we consider the identification of a measure consisting of an unknown linear combination of point sources from a finite number of measurements contaminated by Gaussian noise. The statistical framework for recovery relies on two main ingredients: first, a convex but non-smooth variational Tikhonov point estimator over the space of Radon measures and, second, a suitable mean-squared error based on its Hellinger–Kantorovich distance to the ground truth. To quantify the error, we employ a non-degenerate source condition as well as careful linearization arguments to derive a computable upper bound. This leads to asymptotically sharp error estimates in expectation that are explicit in the sensor configuration. Thus they can be used to estimate the expected reconstruction error for a given sensor configuration and guide the placement of sensors in sparse inverse problems.

97 MATHEMATICS AND COMPUTING↗

Harmonics in the dark-matter sky: directional detection in the Fourier-Bessel basis

Details about the velocity distribution of weakly interacting massive particle (WIMP) dark matter in our galaxy may be revealed by nuclear-recoil detectors with directional sensitivity. Previous studies have assumed that the velocity distribution takes a simple functional form characterized by a small number of parameters. More recent work has shown that basis-function expansions may allow for more general parameterization; such an approach has been considered for both the one-dimensional speed and momentum distributions, and also for three-dimensional velocity distributions obeying certain equilibrium conditions. In this work, I extend this basis-function approach to allow for arbitrary velocity distributions by working in the Fourier-Bessel basis, deriving an analytic expression for the directional recoil spectrum. Such an approach is completely general, and may be useful if the velocity distribution is too complex to be characterized by simple functional forms or is not completely virialized. Results concerning the three-dimensional Radon transform of the Fourier-Bessel basis functions may be of general interest for tomographic applications.

79 ASTRONOMY AND ASTROPHYSICS↗

Preliminary Work Toward a Transuranic Activity Estimation Method for Rapid Discrimination of Anthropogenic from Transuranic Activity in Alpha Air Samples

Radon ( 222 Rn) and thoron ( 220 Rn) progeny (primarily bismuth and polonium) are known interferents when rapid evaluation of transuranic content on air filters is of interest. These complexities stem from the overlapping energies of the progeny alpha particles onto the transuranic region of interest (3–5.5 MeV) where naturally-occurring alpha emitters can overwhelm the spectra. Due to the immediacy of the alpha counting methods employed, coupled with the half-life of thoron progeny dominated by 212 Pb (t 1/2 =10.6 h), a conservative transuranic activity estimate with rigorous uncertainty is being sought. A successful transuranic activity estimation method will incorporate any thoron progeny present on the filter providing 95% confidence decision levels in which a filter may be evaluated for emergency response applications. Twenty-three pairs of samples of various duration having no transuranic content were taken over a 2-mo period. The resulting filters were counted in a time series before non-linear least squares decay curve fitting was applied to the decay profile. For the samples considered, a transuranic activity estima-tor decision level was determined at 0.2 Bq for the given geographic location and months analyzed. In conclusion, validation of this method for other seasonal and geographic regions could provide enhanced emergency response capability when the presence of transuranic activity is suspected.

54 ENVIRONMENTAL SCIENCES↗

EVALUATION OF AN UPWARD TREND IN BACKGROUND COUNT RATES FROM A STACK PARTICULATE CONTINUOUS AIR MONITOR

The Pacific Northwest National Laboratory (PNNL) operates the Radiochemical Processing Laboratory (RPL), which is a multi-purpose, non-reactor nuclear research facility. Regulations require both continuous sampling and monitoring of radioactive particulates and tritium gas in the exhaust from the main stack. Releases of other radioactive gases, including planned releases of radon, are tracked separately in a database and reported. During the 2015 calibration of the RPL stack continuous air monitor (CAM), measured alpha and beta background count rates were much higher than expected, especially when compared to count rates from previous calibrations. The source of the higher background count rates was examined by trending of historical CAM measurements and a comparison to the sampler data. The analysis revealed that the sample results showed no increase in emissions, whereas the CAM showed a steady increase in count rates. Ultimately, the CAM filter was analyzed and found to contain higher-than-normal background levels of 220Rn progeny. Assessments were performed to determine the cause of the increased background values, including reviews of building research activities, radioactive material usage and storage, adequacy of procedures, and the potential for internal CAM contamination. Project reviews determined that a research activity involving 228Th was left in a semi-stored state, resulting in 220Rn being released from a hot cell into the exhaust system. The 228Th source material was subsequently repackaged and contained resulting in a decrease of CAM background count rates. An estimate of the 220Rn release was made and the contribution to the annual offsite dose from the facility was calculated. The released activity and reported dose results were well below the permit limits for the facility.

radon, 220Rn, environmental assessment, air monito↗

Optical homodyne tomography with polynomial series expansion

We present and demonstrate a method for optical homodyne tomography based on the inverse Radon transform. Different from the usual filtered back-projection algorithm, this method uses an appropriate polynomial series to expand the Wigner function and the marginal distribution, and discretize Fourier space. We show that this technique solves most technical difficulties encountered with kernel deconvolution-based methods and reconstructs overall better and smoother Wigner functions. We also give estimators of the reconstruction errors for both methods and show improvement in noise handling properties and resilience to statistical errors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Extraction of nuclear fuels from coal using microwave induced plasma gasification and electromagnetic plasma separation processes

Coal is till today the most commonly used fuel worldwide for electricity generation, with the largest consumers being China, USA and India respectively. Coal contains small amounts of radioactive elements such as uranium, thorium, potassium-40, radium and radon, in the range of a few parts per million, which make their removal difficult and economically unfeasible through conventional industrial technologies. The concentrations gets amplified in the coal ash (fly ash), thereby presenting environmental and human health risks. In this preliminary paper, we propose an innovative clean coal technology, namely microwave induced plasma gasification (MIPG) to turn coal into syngas, while the molten residue is sent to a microwave-heated electromagnetic plasma separator for isolation of radioactive elements. With the adoption of this technology, coal producing and consuming nations will be able to satisfy a large portion of their nuclear fuel requirements from clean coal. (author)

01 COAL, LIGNITE, AND PEAT↗

MR/PET quantification tools: Registration, segmentation, classification, and MR-based attenuation correction

Purpose: Combined MR/PET is a relatively new, hybrid imaging modality. A human MR/PET prototype system consisting of a Siemens 3T Trio MR and brain PET insert was installed and tested at our institution. Its present design does not offer measured attenuation correction (AC) using traditional transmission imaging. This study is the development of quantification tools including MR-based AC for quantification in combined MR/PET for brain imaging. Methods: The developed quantification tools include image registration, segmentation, classification, and MR-based AC. These components were integrated into a single scheme for processing MR/PET data. The segmentation method is multiscale and based on the Radon transform of brain MR images. It was developed to segment the skull on T1-weighted MR images. A modified fuzzy C-means classification scheme was developed to classify brain tissue into gray matter, white matter, and cerebrospinal fluid. Classified tissue is assigned an attenuation coefficient so that AC factors can be generated. PET emission data are then reconstructed using a three-dimensional ordered sets expectation maximization method with the MR-based AC map. Ten subjects had separate MR and PET scans. The PET with [{sup 11}C]PIB was acquired using a high-resolution research tomography (HRRT) PET. MR-based AC was compared with transmission (TX)-based AC on the HRRT. Seventeen volumes of interest were drawn manually on each subject image to compare the PET activities between the MR-based and TX-based AC methods. Results: For skull segmentation, the overlap ratio between our segmented results and the ground truth is 85.2 ± 2.6%. Attenuation correction results from the ten subjects show that the difference between the MR and TX-based methods was <6.5%. Conclusions: MR-based AC compared favorably with conventional transmission-based AC. Quantitative tools including registration, segmentation, classification, and MR-based AC have been developed for use in combined MR/PET.

60 APPLIED LIFE SCIENCES↗

Evaluation of the spline reconstruction technique for PET

Purpose: The spline reconstruction technique (SRT), based on the analytic formula for the inverse Radon transform, has been presented earlier in the literature. In this study, the authors present an improved formulation and numerical implementation of this algorithm and evaluate it in comparison to filtered backprojection (FBP). Methods: The SRT is based on the numerical evaluation of the Hilbert transform of the sinogram via an approximation in terms of “custom made” cubic splines. By restricting reconstruction only within object pixels and by utilizing certain mathematical symmetries, the authors achieve a reconstruction time comparable to that of FBP. The authors have implemented SRT in STIR and have evaluated this technique using simulated data from a clinical positron emission tomography (PET) system, as well as real data obtained from clinical and preclinical PET scanners. For the simulation studies, the authors have simulated sinograms of a point-source and three digital phantoms. Using these sinograms, the authors have created realizations of Poisson noise at five noise levels. In addition to visual comparisons of the reconstructed images, the authors have determined contrast and bias for different regions of the phantoms as a function of noise level. For the real-data studies, sinograms of an{sup 18}F-FDG injected mouse, a NEMA NU 4-2008 image quality phantom, and a Derenzo phantom have been acquired from a commercial PET system. The authors have determined: (a) coefficient of variations (COV) and contrast from the NEMA phantom, (b) contrast for the various sections of the Derenzo phantom, and (c) line profiles for the Derenzo phantom. Furthermore, the authors have acquired sinograms from a whole-body PET scan of an {sup 18}F-FDG injected cancer patient, using the GE Discovery ST PET/CT system. SRT and FBP reconstructions of the thorax have been visually evaluated. Results: The results indicate an improvement in FWHM and FWTM in both simulated and real point-source studies. In all simulated phantoms, the SRT exhibits higher contrast and lower bias than FBP at all noise levels, by increasing the COV in the reconstructed images. Finally, in real studies, whereas the contrast of the cold chambers are similar for both algorithms, the SRT reconstructed images of the NEMA phantom exhibit slightly higher COV values than those of FBP. In the Derenzo phantom, SRT resolves the 2-mm separated holes slightly better than FBP. The small-animal and human reconstructions via SRT exhibit slightly higher resolution and contrast than the FBP reconstructions. Conclusions: The SRT provides images of higher resolution, higher contrast, and lower bias than FBP, by increasing slightly the noise in the reconstructed images. Furthermore, it eliminates streak artifacts outside the object boundary. Unlike other analytic algorithms, the reconstruction time of SRT is comparable with that of FBP. The source code for SRT will become available in a future release of STIR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-45: Reconstruction of CT Images From Sparsely-Sampled Data Using the Logarithmic Barrier Method

Purpose: To develop and investigate whether the logarithmic barrier (LB) method can result in high-quality reconstructed CT images using sparsely-sampled noisy projection data Methods: The objective function is typically formulated as the sum of the total variation (TV) and a data fidelity (DF) term with a parameter λ that governs the relative weight between them. Finding the optimized value of λ is a critical step for this approach to give satisfactory results. The proposed LB method avoid using λ by constructing the objective function as the sum of the TV and a log function whose augment is the DF term. Newton's method was used to solve the optimization problem. The algorithm was coded in MatLab2013b. Both Shepp-Logan phantom and a patient lung CT image were used for demonstration of the algorithm. Measured data were simulated by calculating the projection data using radon transform. A Poisson noise model was used to account for the simulated detector noise. The iteration stopped when the difference of the current TV and the previous one was less than 1%. Results: Shepp-Logan phantom reconstruction study shows that filtered back-projection (FBP) gives high streak artifacts for 30 and 40 projections. Although visually the streak artifacts are less pronounced for 64 and 90 projections in FBP, the 1D pixel profiles indicate that FBP gives noisier reconstructed pixel values than LB does. A lung image reconstruction is presented. It shows that use of 64 projections gives satisfactory reconstructed image quality with regard to noise suppression and sharp edge preservation. Conclusion: This study demonstrates that the logarithmic barrier method can be used to reconstruct CT images from sparsely-amped data. The number of projections around 64 gives a balance between the over-smoothing of the sharp demarcation and noise suppression. Future study may extend to CBCT reconstruction and improvement on computation speed.

60 APPLIED LIFE SCIENCES↗

SU-E-J-174: Adaptive PET-Based Dose Painting with Tomotherapy

Purpose: PET imaging can be converted into dose prescription directly. Due to the variability of the intensity of PET the image, PET prescription maybe superior over uniform dose prescription. Furthermore, unlike the case in image reconstruction of not knowing the image solution in advance, the prescribed dose is known from a PET image a priori. Therefore, optimum beam orientations are derivable. Methods: We can assume the PET image to be the prescribed dose and invert it to determine the energy fluence. The same method used to reconstruct tissue images from projections could be used to solve the inverse problem of determining beam orientations and modulation patterns from a dose prescription [10]. Unlike standard tomographic reconstruction of images from measured projection profiles, the inversion of the prescribed dose results in photon fluence which may be negative and therefore unphysical. Two-dimensional modulated beams can be modelled in terms of the attenuated or exponential radon transform of the prescribed dose function (assumed to be the PET image in this case), an application of a Ram-Lak filter, and inversion by backprojection. Unlike the case in PET processing, however, the filtered beam obtained from the inversion represents a physical photon fluence. Therefore, a positivity constraint for the fluence (setting negative fluence to zero) must be applied (Brahme et al 1982, Bortfeld et al 1990) Results: Truncating the negative profiles from the PET data results in an approximation of the derivable energy fluence. Backprojection of the deliverable fluence is an approximation of the dose delivered. The deliverable dose is comparable to the original PET image and is similar to the PET image. Conclusion: It is possible to use the PET data or image as a direct indicator of deliverable fluence for cylindrical radiotherapy systems such as TomoTherapy.

60 APPLIED LIFE SCIENCES↗

The SRT reconstruction algorithm for semiquantification in PET imaging

Purpose: The spline reconstruction technique (SRT) is a new, fast algorithm based on a novel numerical implementation of an analytic representation of the inverse Radon transform. The mathematical details of this algorithm and comparisons with filtered backprojection were presented earlier in the literature. In this study, the authors present a comparison between SRT and the ordered-subsets expectation–maximization (OSEM) algorithm for determining contrast and semiquantitative indices of {sup 18}F-FDG uptake. Methods: The authors implemented SRT in the software for tomographic image reconstruction (STIR) open-source platform and evaluated this technique using simulated and real sinograms obtained from the GE Discovery ST positron emission tomography/computer tomography scanner. All simulations and reconstructions were performed in STIR. For OSEM, the authors used the clinical protocol of their scanner, namely, 21 subsets and two iterations. The authors also examined images at one, four, six, and ten iterations. For the simulation studies, the authors analyzed an image-quality phantom with cold and hot lesions. Two different versions of the phantom were employed at two different hot-sphere lesion-to-background ratios (LBRs), namely, 2:1 and 4:1. For each noiseless sinogram, 20 Poisson realizations were created at five different noise levels. In addition to making visual comparisons of the reconstructed images, the authors determined contrast and bias as a function of the background image roughness (IR). For the real-data studies, sinograms of an image-quality phantom simulating the human torso were employed. The authors determined contrast and LBR as a function of the background IR. Finally, the authors present plots of contrast as a function of IR after smoothing each reconstructed image with Gaussian filters of six different sizes. Statistical significance was determined by employing the Wilcoxon rank-sum test. Results: In both simulated and real studies, SRT exhibits higher contrast and lower bias than OSEM at the cold lesions. This improvement is achieved at the expense of increasing the noise in the reconstructed images. For the hot lesions, SRT exhibits a small improvement in contrast and LBR over OSEM with 21 subsets and two iterations; however, this improvement is not statistically significant. As the number of iterations increases, the performance of OSEM improves over SRT but again without statistical significance. The curves of contrast and LBR as a function of IR after Gaussian blurring indicate that the advantage of SRT in the cold regions is maintained even after decreasing the noise level by Gaussian blurring. Conclusions: SRT, at the expense of slightly increased noise in the reconstructed images, reconstructs images of higher contrast and lower bias than the clinical protocol of OSEM. This improvement is particularly evident for images involving cold regions. Thus, it appears that SRT should be particularly useful for the quantification of low-count and cold regions.

60 APPLIED LIFE SCIENCES↗