Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantum tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Reconstruction of time-dependent coefficients: A check of approximation schemes for non-Markovian convolutionless dissipative generators

We propose a procedure to fully reconstruct the time-dependent coefficients of convolutionless non-Markovian dissipative generators via a finite number of experimental measurements. By combining a tomography-based approach with a proper data sampling, our proposal allows to relate the time-dependent coefficients governing the dissipative evolution of a quantum system to experimentally accessible quantities. The proposed scheme not only provides a way to retrieve the full information about potentially unknown dissipative coefficients, but also, most valuably, can be employed as a reliable consistency test for the approximations involved in the theoretical derivation of a given non-Markovian convolutionless master equation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Recent developments in guided wave travel time tomography

The concept of predictive maintenance using permanent sensors that monitor the integrity of an installation is an interesting addition to the current method of periodic inspections. Guided wave tomography had been developed to create a map of the wall thickness using the travel times of guided waves. It can be used for both monitoring and for inspection of pipe-segments that are difficult to access, for instance at the location of pipe-supports. An important outcome of the tomography is the minimum remaining wall thickness, as this is critical in the scheduling of a replacement of the pipe-segment. In order to improve the sizing accuracy we have improved the tomography scheme. A number of major improvements have been realized allowing to extend the application envelope to pipes with a larger wall thickness and to larger distances between the transducer rings. Simulation results indicate that the sizing accuracy has improved and that is now possible to have a spacing of 8 meter between the source-ring and the receiver-ring. Additionally a reduction of the number of sensors required might be possible as well.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-ray tomography of large objects with limited measurement angle

In this paper we present an efficient implementation of an algorithm for reconstructing a 3D volume from limited angle projection data, based on statistical inversion theory. We demonstrate the strength of the method for detecting structural defects in large composite aerospace components, whose dimensions prevent acquiring measurements over the full circle. In comparison with a number of other tomographic reconstruction methods that can be applied to the limited angle case, such as tomosynthesis or simultaneous algebraic reconstruction technique (SART), we achieve superior depth resolution with reduced noise and artifacts.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bayesian tomographic reconstruction of microsystems

The microtomography by X ray transmission plays an increasingly dominating role in the study and the understanding of microsystems. Within this framework, an experimental setup of high resolution X ray microtomography was developed at CEA-List to quantify the physical parameters related to the fluids flow in microsystems. Several difficulties rise from the nature of experimental data collected on this setup: enhanced error measurements due to various physical phenomena occurring during the image formation (diffusion, beam hardening), and specificities of the setup (limited angle, partial view of the object, weak contrast).To reconstruct the object we must solve an inverse problem. This inverse problem is known to be ill-posed. It therefore needs to be regularized by introducing prior information. The main prior information we account for is that the object is composed of a finite known number of different materials distributed in compact regions. This a priori information is introduced via a Gauss-Markov field for the contrast distributions with a hidden Potts-Markov field for the class materials in the Bayesian estimation framework. The computations are done by using an appropriate Markov Chain Monte Carlo (MCMC) technique.In this paper, we present first the basic steps of the proposed algorithms. Then we focus on one of the main steps in any iterative reconstruction method which is the computation of forward and adjoint operators (projection and backprojection). A fast implementation of these two operators is crucial for the real application of the method. We give some details on the fast computation of these steps and show some preliminary results of simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam hardening and smoothing correction effects on performance of micro-ct SkyScan 1173 for imaging low contrast density materials

We have designed and fabricated phantom mimicking breast cancer composition known as a region that has low contrast density. The used compositions are a microcalcifications, fatty tissues and tumor mass by using Al{sub 2}O{sub 3}, C{sub 27}H{sub 46}O, and hard nylon materials. Besides, phantom also has a part to calculate low cost criteria /CNR (Contrast to Noise Ratio). Uniformity will be measured at water distillation medium located in a part of phantom scale contrast. Phantom will be imaged by using micro ct-sky scan 1173 high energy type, and then also can be quantified CT number to examine SkyScan 1173 performance in imaging low contrast density materials. Evaluation of CT number is done at technique configuration parameter using voltage of 30 kV, exposure 0.160 mAs, and camera resolution 560x560 pixel, the effect of image quality to reconstruction process is evaluated by varying image processing parameters in the form of beam hardening corrections with amount of 25%, 66% and100% with each smoothing level S10,S2 and S7. To obtain the better high quality image, the adjustment of beam hardening correction should be 66% and smoothing level reach maximal value at level 10.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-ray microscopy of soft and hard human tissues

The simultaneous post mortem visualization of soft and hard tissues using absorption-based CT remains a challenge. If the photon energy is optimized for the visualization of hard tissue, the surrounding soft tissue components are almost X-ray transparent. Therefore, the combination with other modalities such as phase-contrast CT, magnetic resonance microscopy, and histology is essential to detect the anatomical features. The combination of the 2D and 3D data sets using sophisticated segmentation and registration tools allows for conclusions about otherwise inaccessible anatomical features essential for improved patient treatments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast entanglement detection for unknown states of two spatial qutrits

We investigate the practicality of the method proposed by Maciel et al. [Phys. Rev. A. 80, 032325 (2009).] for detecting the entanglement of two spatial qutrits (three-dimensional quantum systems), which are encoded in the discrete transverse momentum of single photons transmitted through a multislit aperture. The method is based on the acquisition of partial information of the quantum state through projective measurements, and a data processing analysis done with semidefinite programs. This analysis relies on generating gradually an optimal entanglement witness operator, and numerical investigations have shown that it allows for the entanglement detection of unknown states with a cost much lower than full state tomography.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Clinical application and validation of an iterative forward projection matching algorithm for permanent brachytherapy seed localization from conebeam-CT x-ray projections

Purpose: To experimentally validate a new algorithm for reconstructing the 3D positions of implanted brachytherapy seeds from postoperatively acquired 2D conebeam-CT (CBCT) projection images. Methods: The iterative forward projection matching (IFPM) algorithm finds the 3D seed geometry that minimizes the sum of the squared intensity differences between computed projections of an initial estimate of the seed configuration and radiographic projections of the implant. In-house machined phantoms, containing arrays of 12 and 72 seeds, respectively, are used to validate this method. Also, four {sup 103}Pd postimplant patients are scanned using an ACUITY digital simulator. Three to ten x-ray images are selected from the CBCT projection set and processed to create binary seed-only images. To quantify IFPM accuracy, the reconstructed seed positions are forward projected and overlaid on the measured seed images to find the nearest-neighbor distance between measured and computed seed positions for each image pair. Also, the estimated 3D seed coordinates are compared to known seed positions in the phantom and clinically obtained VariSeed planning coordinates for the patient data. Results: For the phantom study, seed localization error is (0.58{+-}0.33) mm. For all four patient cases, the mean registration error is better than 1 mm while compared against the measured seed projections. IFPM converges in 20-28 iterations, with a computation time of about 1.9-2.8 min/iteration on a 1 GHz processor. Conclusions: The IFPM algorithm avoids the need to match corresponding seeds in each projection as required by standard back-projection methods. The authors' results demonstrate {approx}1 mm accuracy in reconstructing the 3D positions of brachytherapy seeds from the measured 2D projections. This algorithm also successfully localizes overlapping clustered and highly migrated seeds in the implant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Capturing 3D atomic defects and phonon localization at the 2D heterostructure interface

The three-dimensional (3D) local atomic structures and crystal defects at the interfaces of heterostructures control their electronic, magnetic, optical, catalytic, and topological quantum properties but have thus far eluded any direct experimental determination. Here, we use atomic electron tomography to determine the 3D local atomic positions at the interface of a MoS 2 -WSe 2 heterojunction with picometer precision and correlate 3D atomic defects with localized vibrational properties at the epitaxial interface. We observe point defects, bond distortion, and atomic-scale ripples and measure the full 3D strain tensor at the heterointerface. By using the experimental 3D atomic coordinates as direct input to first-principles calculations, we reveal new phonon modes localized at the interface, which are corroborated by spatially resolved electron energy-loss spectroscopy. We expect that this work will pave the way for correlating structure-property relationships of a wide range of heterostructure interfaces at the single-atom level.

42 ENGINEERING↗

Continuous-Variable Quantum State Designs: Theory and Applications

We generalize the notion of quantum state designs to infinite-dimensional spaces. We first prove that, under the definition of continuous-variable (CV) state t -designs from [Blume-Kohout , ], no state designs exist for t ≥ 2 . Similarly, we prove that no CV unitary t -designs exist for t ≥ 2 . We propose an alternative definition for CV state designs, which we call rigged t -designs, and provide explicit constructions for t = 2 . As an application of rigged designs, we develop a design-based shadow-tomography protocol for CV states. Using energy-constrained versions of rigged designs, we define an average fidelity for CV quantum channels and relate this fidelity to the CV entanglement fidelity. As an additional result of independent interest, we establish a connection between torus 2-designs and complete sets of mutually unbiased bases. Published by the American Physical Society 2024

Physics↗

Riemann–Hilbert problem approach for two-dimensional flow inverse scattering

We consider inverse scattering for the time-harmonic wave equation with first-order perturbation in two dimensions. This problem arises in particular in the acoustic tomography of moving fluid. We consider linearized and nonlinearized reconstruction algorithms for this problem of inverse scattering. Our nonlinearized reconstruction algorithm is based on the non-local Riemann–Hilbert problem approach. Comparisons with preceding results are given.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Fate of MAb targeted Cd125mTe/ZnS nanoparaticles in vivo

Nanoparticles (NP) have potential as carriers for drugs and radioisotopes. Quantitative measures of NP biodistribution in vivo are needed to determine the effectiveness of these carriers. We have used a model system of radiolabeled quantum dots to document the competition between efficient vascular targeting and interaction of the NP with the reticuloendothelial (RE) system. We have prepared (125m)Te-labeled CdTe NP that are capped with ZnS. Te-125m has a half-life and decay characteristics very similar to those for (125)I. The synthesized particles are stable in aqueous solution and are derivatized with mercaptoacetic acid and then conjugated with specific antibody. To evaluate specific targeting, we used the monoclonal antibody MAb 201B that binds to murine thrombomodulin expressed in the lumen of lung blood vessels. The MAb-targeted NP were tested for targeting performance in vivo using single-photon emission computed tomography (SPECT)/computed tomography (CT) imaging, tissue autoradiography and standard organ biodistribution techniques. Biodistribution was also determined in mice that had been depleted of phagocytic cells by use of clodronate-loaded liposomes. Cd(125m)Te/ZnS NP coupled with MAb 201B retained radioisotope and antibody activity and accumulated in lung (>400% injected dose [ID]/g) within 1 h of intravenous injection. Control antibody-coupled NP did not accumulate in lung (<10% ID/g) but accumulated in liver and spleen. Images from microSPECT/CT and autoradiography studies of the targeted NP document this specific uptake and demonstrate uniform distribution in lung with minor accumulation in liver and spleen. Within a few hours, a large fraction of lung-targeted NP redistributed to spleen and liver or was excreted. We hypothesized that NP attract phagocytic cells that engulfed and removed them from circulation. This was confirmed by comparing biodistribution of targeted NP in normal mice versus those depleted of phagocytic cells. In mice treated with clodronate liposomes, accumulation of NP in liver was reduced by fivefold, while accumulation in lung at 1 h was enhanced by approximately 50%. By 24 h, loss of the targeted NP from lung was inhibited by several-fold, while accumulation in liver and spleen remained constant. Thus, the treated mice had a much larger accumulation and retention of the NP at the target site and a decrease in dose to other organs except spleen. Nanoparticles composed of CdTe, labeled with (125m)Te and capped with ZnS, can be targeted with MAb to sites in the lumen of lung vasculature. In clodronate-treated mice, which have a temporary depletion of phagocytic cells, accumulation in liver was reduced dramatically, whereas that in spleen was not. The targeting to lung was several-fold more efficient in clodronate-treated mice due to larger initial accumulation and better retention of the MAb-targeted NP at that site. This model system indicates that targeting of NP preparations is a competition between the effectiveness of the targeting agent and the natural tendency for RE uptake of the particles. Temporary inhibition of the RE system may enhance the usefulness of NP for drug and radioisotope delivery.

59 BASIC BIOLOGICAL SCIENCES↗

Design and development of an electrically-controlled beam steering mirror for microwave tomography

Microwave tomography has gained significant attention due to its reliability and unhazardous nature in the fields of NDE and medical industry. A new microwave tomography system is presented in this paper, which significantly reduces the design and operational complexities of traditional microwave imaging systems. The major component of the proposed system is a reconfigurable reflectarray antenna which is used for beam steering in order to generate projections from multiple angles. The design, modeling and fabrication of the building block of the antenna, a tunable unit cell, are discussed in this paper. The unit cell is capable of dynamically altering the phase of the reflected field which results in beam steering ability of the reflectarray antenna. A tomographically reconstructed image of a dielectric sample using this new microwave tomography system is presented in this work.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Generalized spatial filtering velocimetry and accelerometry for uniform and nonuniform objects

We present a technique to measure velocity, acceleration, and higher order derivatives of motion using periodic and nonperiodic spatial filters. The technique can be applied using a single detector or an array of detectors. In one configuration, the velocity distribution of an object such as a fluid can be measured by imaging the object onto an array of detectors. In another configuration, multiple projections of an object are used to reconstruct a cross-sectional velocity distribution using a tomography algorithm. The advantages and disadvantages of our technique applied to uniform and spatially varying motions are described.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Attenuation properties and percentage depth dose of tannin-based Rhizophora spp. particleboard phantoms using computed tomography (CT) and treatment planning system (TPS) at high energy x-ray beams

A set of tannin-based Rhizophora spp. particleboard phantoms with dimension of 30 cm x 30 cm was fabricated at target density of 1.0 g/cm{sup 3}. The mass attenuation coefficient of the phantom was measured using {sup 60}Co gamma source. The phantoms were scanned using Computed Tomography (CT) scanner and the percentage depth dose (PDD) of the phantom was calculated using treatment planning system (TPS) at 6 MV and 10 MV x-ray and compared to that in solid water phantoms. The result showed that the mass attenuation coefficient of tannin-based Rhizohora spp. phantoms was near to the value of water with χ{sup 2} value of 1.2. The measured PDD also showed good agreement with solid water phantom at both 6 MV and 10 MV x-ray with percentage deviation below 8% at depth beyond the maximum dose, Z{sub max}.

07 ISOTOPE AND RADIATION SOURCES↗

X-ray tomographic in-service inspection of girth welds - The European project TomoWELD

The new standard 'ISO 17636-2:2013: Non-destructive testing of welds - Radiographic testing - Part 2: X- and gamma-ray techniques with digital detectors', defines the practice for radiographic inspection of welded pipes for manufacturing and in-service inspection. It is applied in Europe for inspections of pipe welds in nuclear power plants as well as in chemical plants and allows a faster inspection with digital detector arrays (DDA) than with film. Nevertheless, it does not allow the evaluation of the depth and shape of volumetric and planar indications. In 2001 a planar tomography scanner, TomoCAR, was introduced for mechanized radiographic testing (RT) inspection and non-destructive measurement of cross sections. The project TomoWELD is based on a new concept of the scan geometry, an enhanced GPU based reconstruction, and the application of a new generation of photon counting DDAs based on CdTe crystal CMOS hybrids. The new detector permits the selection of energy thresholds to obtain an optimum energy range and reduction of the influence of scattered radiation. The concept and first measurements are presented. Flaw depth and shape of volumetric and planar irregularities can be determined.

36 MATERIALS SCIENCE↗

Ultrafast three-dimensional x-ray computed tomography

X-ray computed tomography (CT) is a well established visualization technique in medicine and nondestructive testing. However, since CT scanning requires sampling of radiographic projections from different viewing angles, common CT systems with mechanically moving parts are too slow for dynamic imaging, for instance of multiphase flows or live animals. Here, we introduce an ultrafast three-dimensional x-ray CT method based on electron beam scanning, which achieves volume rates of 500 s{sup -1}. Primary experiments revealed the capability of this method to recover the structure of phase boundaries in gas-solid and gas-liquid two-phase flows, which undergo three-dimensional structural changes in the millisecond scale.

42 ENGINEERING↗