Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pulse shaping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Characterization of the ORNL SiPM PSD ASIC's Basic Properties

ORNL has developed an ASIC intended for reading out arrays of Silicon Photomultipliers coupled to scintillator materials that exhibit neutron/gamma pulse shape discrimination. The ASIC's basic properties: power consumption, linearity, PSD FoM, and timing resolution have all been measured and the results are presented here.

47 OTHER INSTRUMENTATION↗

Application of the Cohn-alpha Method on Bare Highly Enriched Uranium Using Organic Scintillators [Poster]

The prompt neutron decay constant (α), can be used to calculate the lifetime of prompt fission chains within a multiplying system and verify reactor startup and shutdown. We analyze a fast, bare system consisting of highly enriched uranium (93% 235 U) hemisphere shells known as the Measurements of Uranium Subcritical and Critical (MUSiC). We measured the system with a three by-four array of organic scintillators (OSCAR) to obtain the gamma-ray and fast neutron signals. Pulse shape discrimination was used to isolate the neutron time series data. The Cohn-α method was used to estimate α for 3 supercritical measurements of Configurations 8 MUSiC. We use these estimates to linearly extrapolate α at delayed critical. These values can be compared to highly detailed simulations in MCNP6.2.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of ORNL PSD ASIC

The performance of the ORNL ASIC and its readout system was tested with pixelated organic scintillators. We use a pixelated trans-Stilbene scintillator array from Inrad Optics and a pixelated organic glass scintillator array developed at Sandia National Laboratories to characterize the energy and timing resolutions and the pulse-shape discrimination (PSD) figure-of-merit (FoM). The results are compared to previous work in which the same metrics were measured on waveforms digitized at 250 MHz with 14-bit resolution. We found that the PSD FoM at 340 keVee of the ASIC configuration compared to waveform data varied with the scintillator type. We measured a PSD FoM of 1.12 ± 0.14 with the ASIC configuration versus 1.39 ± 0.23 with waveform data using the trans-Stilbene array. We measured a PSD FoM of 0.52 ± 0.18 with the ASIC configuration versus 1.25 ± 0.19 with waveform data using the the organic glass scintillator array. The coincidence timing resolution was measured using two 6x6x6 mm 3 cubes of trans-Stilbene. It was measured to be 805 ± 9 ps with the ASIC configuration versus 300 ps on average with waveform data.

42 ENGINEERING↗

Field Test Report Neutron Scintillator Array Dry Storage Cask Scanner FY2024

During two weeks of Field Testing at the Idaho National Laboratory INTEC Cask Farm in July and August 2024, the LLNL Dry Storage Cask Scanner Array was lifted on top of an MC-10 dry storage fuel cask and operated to acquire neutron and gamma-ray data from the 24 fuel bundle positions. Neutron and gamma-ray data acquisition scans across the top of the cask of varying dwell times were performed July 15-18, 2024 and August 19-22, 2024 to evaluate the ability of the scanner data to reveal asymmetries in the fuel positions that reflect asymmetries in the MC-10 cask fuel bundle loading. The MC-10 cask 24 position fuel bundle loading at the INTEC Cask Farm is well documented, including the locations of six empty fuel bundle positions. This loading presents an opportunity to test the ability of the scanner system to detect diversion of spent fuel bundles as well as to validate the MC-10 cask MCNP modeling. The cask scanner array consists of six Stilbene crystal scintillator detectors and a linear actuator frame that moves the six detectors across the MC-10 dry storage cask to obtain data above each of the 24 fuel bundle positions. The detectors are connected to a pulse-shape discrimination data acquisition system capable of generating separate neutron and gamma-ray spectra for each detector and for each scan position. From the prior single detector Field Test in 2021 and iteration with MCNP modeling, the neutron and gamma-ray data were analyzed in multiple energy regions to identify an analysis method that would provide the strongest and most consistent signature of the asymmetric MC-10 cask fuel loading1 . From both the 2021 Field Test and the current Field Test results, the neutron capture gamma-ray count rate around 2.2 MeV provides the strongest signature of the asymmetric MC-10 cask fuel loading and has qualitative agreement with MCNP calculations. Counting all gamma-rays produces a similar signature. Neutrons emerging from the cask top are moderated and captured by the hydrogen in the polyethylene moderator and scintillator detector, producing a 2.2 MeV gamma ray which is seen in the scintillator gamma-ray spectrum. The count rate in the 2.2 MeV gamma-ray region is ~50 c/s, which is ~1000x higher than the ~0.05 n/s rate in the > 4MeV neutron region, and ~50x greater than the ~1 n/s rate in the neutrons > 500 keV region. Analysis of the 2.2 MeV neutron-capture Compton-scattered gamma-rays produces a statistically significant signature of the INTEC Cask Farm MC-10 asymmetric fuel loading. MCNP simulations indicate that the average neutron energy spectrum offers the potential to detect a large asymmetry from several missing bundles as well as individual missing fuel bundles. Testing this feature will require measurements on a cask with single missing elements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterization of Neutron Emission Rates of Commercial 252 Cf Sources

Accurate knowledge of 252 Cf neutron emission rates is critical for modeling and fast-neutron experiments, yet commercial sources are often supplied without traceable calibration or uncertainty estimates. This report describes a method to characterize 252 Cf sources using a pulse-shape-discrimination (PSD) scintillator. The scintillator was efficiency-calibrated against a time-tagged 252 Cf fission chamber manufactured at ORNL over 40 years ago. Isotopic evolution of the calibration source was modeled using Bateman equations to account for changes in the effective average neutrons per fission at the time of measurement. The calibrated scintillator was then used to measure absolute emission rates of several commercial 252 Cf sources, revealing deviations of up to 12% from nominal manufacturer values. This methodology provides a practical approach for establishing uncertainty-quantified 252 Cf neutron emission rates, improving fidelity in simulations and supporting the accurate interpretation of measurements.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Current-Regulated Arc Modulator Optimization

n this study, the performance of a current-regulated arc modulator was investigated with a focus on its role in initiating and sustaining plasma discharge within the Magnetron Body of the LINAC system. The analysis centered on how switching components, circuit topology, and feedback loop architecture influence critical factors such as energy efficiency, discharge stability, and long-term plasma containment. Particular attention was given to variations in pulse termination behavior, as observed through oscilloscope traces, which revealed inconsistencies affecting the duty factor and cathode temperature. These fluctuations have downstream effects on the cesium-coated cathode surface, thereby impacting H⁻ ion production and beam reliability. Simulation-based testing in LTspice was used to evaluate noise suppression techniques and arc current regulation schemes, revealing how optimized snubber networks, improved pulse shaping, and feedback stability can mitigate modulator-induced noise. The results ide

Campos, Nathan↗

FNCL Enhancements Implementation (FY25 Annual Report)

The FNCL investigations team at Lawrence Livermore National Laboratory (LLNL) has completed research and development of hardware, signal processing, and analysis tools to enhance the measurement capabilities of both the current CAEN SyS VeryFuel Fast Neutron Collar (FNCL) instrument and a next-generation FNCL prototype. The team successfully built and commissioned the LLNL Demonstrator System: a fully integrated, three-panel detector system featuring higher segmentation, plastic scintillators (EJ-276D), Silicon Photomultipliers (SiPMs), no high-voltage requirement, a reduced electronic footprint, and the LLNL-developed Gaussian Mixture Model Pulse Shape Discrimination (GMM-PSD) signal processing. An extensive experimental campaign was conducted at LLNL’s Inherently Safe Subcritical Assembly (ISSA) facility using both the baseline FNCL and the LLNL Demonstrator. The campaign results validated system performance, calibration stability, and the effectiveness of advanced signal processing and analysis algorithms in a relevant environment.

and physical protection↗

Masked Symbol Modeling for Demodulation of Oversampled Baseband Communication Signals in Impulsive Noise-Dominated Channels

Recent breakthroughs in natural language processing show that attention mech- anism in Transformer networks, trained via masked-token prediction, enables models to capture the semantic context of the tokens and internalize the grammar of language. While the application of Transformers to communication systems is a burgeoning field, the notion of context within physical waveforms remains under-explored. This paper addresses that gap by re-examining inter-symbol con- tribution (ISC) caused by pulse-shaping overlap. Rather than treating ISC as a nuisance, we view it as a deterministic source of contextual information embedded in oversampled complex baseband signals. We propose Masked Symbol Model- ing (MSM), a framework for the physical (PHY) layer inspired by Bidirectional Encoder Representations from Transformers methodology. In MSM, a subset of symbol-aligned samples is randomly masked, and a Transformer predicts the missing symbol identifiers using the surrounding “in-between” samples. Through this objective, the model learns the latent syntax of complex baseband waveforms. We illustrate MSM’s potential by applying it to the task of demodulating sig- nals corrupted by impulsive noise, where the model infers corrupted segments by leveraging the learned context. Our results suggest a path toward receivers that interpret, rather than merely detect communication signals, opening new avenues for context-aware PHY layer design.

Bedir, Oguz↗

Passive Confirmation of the Presence Of High-Explosive Material Via Neutron Transmission Spectroscopy

The goal of this project was to explore a novel approach for identifying presence and potential types of high explosives (HE) in treaty-controlled items with passive neutron sources by using passive neutron transmission spectroscopy. We predominantly look to measure relative elemental abundance of Carbon, Hydrogen, Oxygen, and Nitrogen (CHON) since most relevant materials are certain mix of these elements, as shown in Table 1. Previously, most studies exploring potential identification of CHON elemental content of targets in the vicinity of passive neutron source were focused solely on gamma spectroscopy using high resolution gamma detectors. Using neutron transmission spectroscopy with pulse-shape discrimination (PSD) capable organic scintillators is not only a novel idea in of itself, but arguably necessary for accurate identification of the CHON elemental content of an interrogated target. While high resolution gamma spectroscopy in principle can determine a presence of hydrogen and nitrogen, it is effectively blind to a quantitatively measuring areal densities of C, O. The initially proposed approach, described in detail in the project proposal, was to leverage previous Monte Carlo study on neutron transmission spectroscopy using slab shaped target interrogated with well-collimated (“pencil”) neutron beam. In this study, a simulated test CO 2 target was interrogated by a pencil neutron beam and transmitted neutron spectra were measured using PSD capable organic scintillator using MLEM based unfolding technique. To establish relative elemental content of carbon and oxygen, the unfolded neutron spectrum was fit with a parametrized combination of their respective elemental spectral templates. The individual spectral template was calculated by convoluting ENDF neutron crosssection with the known resolution of the PSD detector used in the study. This approach in the studied configuration successfully quantitatively established relative elemental composition of carbon and oxygen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deuterated Xylene-Based Neutron Spectrometry

Deuterated scintillators, such as deuterated xylene (C8D10) have been theorized to offer better pulse shape discrimination (PSD) and neutron spectrometry performance than traditional protiated scintillators due to the anisotropy of neutron scattering on deuterium. However, the light output responses of said deuterated scintillators to monoenergetic has not been characterized in its entirety at both high and low energies. Several time-of-flight experiments were conducted at the Idaho national Laboratory to characterize a pair of EJ-301D deuterated xylene detectors. The low energy detector response to quasi-monoenergetic neutrons was measured using a Cf-252 source, and the high energy detector response was measured using a D-T source and angles of 20, 45, and 60 deg, corresponding to theoretical neutron energies of 13.2, 10.4, and 8.2 MeV. During post-processing, the neutron and gamma bands were clearly able to be separated, even at low light outputs, solidifying the superior PSD capability of deuterated xylene. An exponential of fit of LO=0.63E-2.22*(1-exp(-0.25E)), which has good agreement with previously measured data, was found as the light output response from deuteron recoils. Additionally, measurements of AmBe, D-T, and D-D sources were unfolded using the light output response curve, which resulted in favorable agreement with theoretical values. Further testing of the response matrix by unfolding more sources (such as PuBe) needs to be done, but the unfolding accuracy for currently available sources suggests that deuterated xylene can be used to measure and unfold both fission, monoenergetic, and continuous spectra.

scintillator↗

Fast-, Light-Cured Scintillating Plastic for 3D-Printing Applications

Additive manufacturing techniques enable a wide range of possibilities for novel radiation detectors spanning simple to highly complex geometries, multi-material composites, and metamaterials that are either impossible or cost prohibitive to produce using conventional methods. The present work identifies a set of promising formulations of photocurable scintillator resins capable of neutron-gamma pulse shape discrimination (PSD) to support the additive manufacturing of fast neutron detectors. The development of these resins utilizes a step-by-step, trial-and-error approach to identify different monomer and cross-linker combinations that meet the requirements for 3D printing followed by a 2-level factorial parameter study to optimize the radiation detection performance, including light yield, PSD, optical clarity, and hardness. The formulations resulted in hard, clear, PSD-capable plastic scintillators that were cured solid within 10 s using 405 nm light. The best-performing scintillator produced a light yield 83% of EJ-276 and a PSD figure of merit equaling 1.28 at 450–550 keVee.

Frandsen, Brian G. (ORCID:0000000319964320)↗

Versatile analog pulse height computer performs real-time arithmetic operations

Multipurpose analog pulse height computer performs real-time arithmetic operations on relatively fast pulses. This computer can be used for identification of charged particles, pulse shape discrimination, division of signals from position sensitive detectors, and other on-line data reduction techniques.

Brenner, R.↗