Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “proton”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Sci-Fri PM: Radiation Therapy, Planning, Imaging, and Special Techniques - 01: On the use of proton radiography to reduce beam range uncertainties and improve patient positioning accuracy in proton therapy

To present two related developments of proton radiography (pRad) to minimize range uncertainty in proton therapy. The first combines a pRad with an X-ray CT to produce a patient-specific relative stopping power (RSP) map. The second aims to improve the pRad spatial resolution for accurate registration prior to the first. The enhanced-pRad can also be used in a novel proton-CT reconstruction algorithm. Monte Carlo pRad were computed from three phantoms; the Gammex, the Catphan and an anthropomorphic head. An optimized cubic-spline estimator derives the most likely path. The length crossed by the protons voxel-by-voxel was calculated by combining their estimated paths with the CT. The difference between the theoretical (length×RSP) and measured energy loss was minimized through a least squares optimization (LSO) algorithm yielding the RSP map. To increase pRad spatial resolution for registration with the CT, the phantom was discretized into voxels columns. The average column RSP was optimized to maximize the proton energy loss likelihood (MLE). Simulations showed precise RSP (<0.75%) for Gammex materials except low-density lung (<1.2%). For the head, accurate RSP were obtained (µ=−0.10%1.5σ=1.12%) and the range precision was improved (ΔR80 of −0.20±0.35%). Spatial resolution was increased in pRad (2.75 to 6.71 lp/cm) and pCT from MLE-enhanced pRad (2.83 to 5.86 lp/cm). The LSO decreases the range uncertainty (R80σ<1.0%) while the MLE-enhanced pRad spatial resolution (+244%) and is a great candidate for pCT reconstruction.

60 APPLIED LIFE SCIENCES↗

On the possibility for precision measurements of differential cross sections for elastic proton–proton scattering at the Protvino accelerator

Elastic-scattering data were analyzed, and it was concluded on the basis of this analysis that precisionmeasurements of differential cross sections for elastic proton–proton scattering at the accelerator of the Institute for High Energy Physics (IHEP, Protvino, Russia) over a broad momentum-transfer range are of importance and topical interest. The layout of the respective experimental facility detecting the scattered particle and recoil proton and possessing a high momentum-transfer resolution was examined along with the equipment constituting this facility. The facility in question is able to record up to a billion events of elastic proton–proton scattering per IHEP accelerator run (20 days). Other lines of physics research with this facility are briefly discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Studies of a proton phase beam monitor for range verification in proton therapy

A primary subject of the present research in particle therapy is to ensure the precise irradiation of the target volume. The prompt gamma timing (PGT) method provides one possibility for in vivo range verification during the irradiation of patients. Prompt gamma rays with high energies are emitted promptly due to nuclear reactions of protons with tissue. The arrival time of these gammas to the detector reflects the stopping process of the primary protons in tissue and are directly correlated to the range. Due to the time resolution of the detector and the proton bunch time spread, as well as drifts of the bunch phase with respect to the accelerator frequency, timing spectra are smeared out and compromise the accuracy of range information intended for future clinical applications. Nevertheless, counteracting this limitation and recovering range information from the PGT measured spectra, corrections using a phase beam monitor can be performed. A first prototype of phase beam monitor was tested at GSI Darmstadt, where measurements of the energy profile of the ion bunches were performed. At the ELBE accelerator Helmholtz-Zentrum Dresden-Rossendorf (HZDR), set up to provide bremsstrahlung photons in very short pulses, a constant fraction algorithm for the incoming digital signals was evaluated, which is used for optimizing the time resolution. Studies of scattering experiments with different thin targets and detector positions are accomplished at Oncoray Dresden, where a clinical proton beam is available. These experiments allow a basic characterization of the proton bunch structure and the detection yield. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Use of Ionization Electron Columns for Space-Charge Compensation in High Intensity Proton Accelerators

We discuss a recent proposal to use strongly magnetized electron columns created by beam ionization of the residual gas for compensation of space charge forces of high intensity proton beams in synchrotrons and linacs. The electron columns formed by trapped ionization electrons in a longitudinal magnetic field that assures transverse distribution of electron space charge in the column is the same as in the proton beam. Electrostatic electrodes are used to control the accumulation and release of the electrons. Ions are not magnetized and drift away without affecting the compensation. Possible technical solution for the electron columns is presented. We also discuss the first numerical simulation results for space-charge compensation in the FNAL Booster and results of relevant beam studies in the Tevatron.

43 PARTICLE ACCELERATORS↗

Proton Structure and Atomic Physics

We discuss a precise determination of the polarizability and other proton structure dependent contributions to the hydrogen hyperfine splitting, based heavily on the most recent published data on proton spin dependent structure functions from the EG1 experiment at the Jefferson Laboratory. As a result, the total calculated hyperfine splitting now has a standard deviation slightly under 1 part-per-million, and is about 1 standard deviation away from the measured value.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A detection system for very low-energy protons from {beta}-delayed proton decay

We have recently developed a gas based detection system called AstroBox, motivated by nuclear astrophysics studies. The goal was to detect very low-energy protons from {beta}-delayed p-decay with reduced beta background and improved energy resolution. The detector was tested using the {beta}-delayed proton-emitter 23Al previously studied with a set-up based on thin double-sided Si strip detectors. The proton spectrum obtained with AstroBox showed no beta background down to {approx}80 keV. The low energy (206 keV, 267 keV) proton peaks were positively identified, well separated, and the resolution was improved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low energy proton-proton scattering in effective field theory

Low energy proton-proton scattering is studied in pionless effective field theory. Employing the dimensional regularization and MS and power divergence subtraction schemes for loop calculation, we calculate the scattering amplitude in the {sup 1}S{sub 0} channel up to the next-to-next-to leading order and fix low-energy constants that appear in the amplitude by effective range parameters. We study the regularization scheme and scale dependence in the separation of the Coulomb interaction from the scattering length and effective range for the S-wave proton-proton scattering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Proton-proton bremsstrahlung: Consequences of different on-shell-point conditions

Background: Proton-proton bremsstrahlung (pp{gamma}) is investigated both theoretically and experimentally. The pp{gamma} amplitudes can be classified according to the number and location of on-shell points at which they are evaluated. Quantitative understanding of the effect on the pp{gamma} cross section of using different on-shell-point conditions is lacking, but it is essential to identifying the photon emission mechanism governing the pp{gamma} process. Method: Four different pp{gamma} amplitudes, which include four-on-shell-point amplitudes and one-on-shell-point amplitude, are generated from a realistic one-boson-exchange (ROBE) model for pp scattering. These ROBE amplitudes are used to investigate the consequence of using different on-shell-point conditions in calculating the pp{gamma} cross sections. Purpose: We verify the validity of the ROBE pp{gamma} amplitudes. We explore similarities between the four-on-shell-point ROBE and two-u-two-t special (TuTts) soft-photon pp{gamma} amplitudes and important differences with the one-on-shell-point ROBE and Low pp{gamma} amplitudes. We demonstrate that the precision Kernfysisch Versneller Instituut (KVI) data can only be described by the four-on-shell-point (ROBE or TuTts) amplitude. We use the ROBE four-on-shell-point amplitude and one-on-shell-point amplitude to investigate systematically the effect of using different on-shell-point conditions to calculate the pp{gamma} cross section. Furthermore, we identify a general principle that governs the process. This general principle is also applicable to other bremsstrahlung processes involving the scattering of two identical nucleons. Results: (i) The four-on-shell-point ROBE (or TuTts) amplitude describes the high-precision KVI data much better than does the one-on-shell-point ROBE (or Low) amplitude. Although the contribution from the anomalous magnetic moment of the proton is very significant, it does not completely dominate the KVI pp{gamma} cross sections. (ii) The four-on-shell-point ROBE (or TuTts) amplitude describes the TRIUMF data better than does the one-on-shell-point ROBE (or Low) amplitude. (iii) The effect on the pp{gamma} cross section of using different on-shell-point conditions is significant in the hard-photon region, i.e., for small proton scattering angles {theta} (={theta}{sub 3}={theta}{sub 4}, symmetric scattering angles) far from the elastic limit ({theta}{yields}45 deg.); in contrast, the effect becomes insignificant in the vicinity of the elastic limit. Near the limit as {theta} tends to 45 deg. (or as the photon energy K approaches zero), the four-on-shell-point and one-on-shell-point amplitudes approach one another, a general principle applicable to all bremsstrahlung processes because only kinematics is involved. Conclusion: The four-on-shell-point ROBE amplitude provides a quantitative description of pp{gamma} cross sections. The anomalous magnetic moment is an important component of the photon emission mechanism. The four-on-shell-point property of the full ROBE amplitude is essential to properly describing the complete range of the precision KVI data and the TRIUMF data, although the one-on-shell-point ROBE amplitude is adequate in the region near the elastic limit.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High temperature proton exchange membranes with enhanced proton conductivities at low humidity and high temperature based on polymer blends and block copolymers of poly(1,3-cyclohexadiene) and poly(ethylene glycol)

Hot (at 120 °C) and dry (20% relative humidity) operating conditions benefit fuel cell designs based on proton exchange membranes (PEMs) and hydrogen due to simplified system design and increasing tolerance to fuel impurities. In this paper, presented are preparation, partial characterization, and multi-scale modeling of such PEMs based on cross-linked, sulfonated poly(1,3-cyclohexadiene) (xsPCHD) blends and block copolymers with poly(ethylene glycol) (PEG). These low cost materials have proton conductivities 18 times that of current industry standard Nafion at hot, dry operating conditions. Among the membranes studied, the blend xsPCHD-PEG PEM displayed the highest proton conductivity, which exhibits a morphology with higher connectivity of the hydrophilic domain throughout the membrane. Simulation and modeling provide a molecular level understanding of distribution of PEG within this hydrophilic domain and its relation to proton conductivities. Finally, this study demonstrates enhancement of proton conductivity at high temperature and low relative humidity by incorporation of PEG and optimized sulfonation conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Infrared spectroscopy of the protonated nitrogen dimer: The complexity of shared proton vibrations

The proton-bridged dimers of nitrogen, e.g., N{sub 2}-H{sup +}-N{sub 2} and N{sub 2}-D{sup +}-N{sub 2}, are produced in a pulsed-discharge supersonic nozzle source, mass selected in a reflectron time-of-flight spectrometer, and studied with infrared photodissociation spectroscopy using the method of messenger atom tagging with argon. Both complexes are studied from 700-4000 cm{sup -1}. These spectra reproduce the high frequency vibrations seen previously but discover many new vibrational bands, particularly those in the region of the shared proton modes. Because of the linear structure of the core ions, simple vibrational spectra are expected containing only the antisymmetric N-N stretch and two lower frequency modes corresponding to proton stretching and bending motions. However, many additional bands are detected corresponding to various combination bands in this system activated by anharmonic couplings of the proton motions. The anharmonic coupling is stronger for the H{sup +} system than it is for the D{sup +} system. Using anharmonic proton vibrations computed previously and combinations of computed harmonic frequencies, reasonable assignments can be made for the spectra of both isotopomers. However, advanced anharmonic computational treatments are needed for this system to confirm these assignments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-J-175: Proton Dose Calculation On Scatter-Corrected CBCT Image: Feasibility Study for Adaptive Proton Therapy

Purpose: To demonstrate feasibility of proton dose calculation on scattercorrected CBCT images for the purpose of adaptive proton therapy. Methods: Two CBCT image sets were acquired from a prostate cancer patient and a thorax phantom using an on-board imaging system of an Elekta infinity linear accelerator. 2-D scatter maps were estimated using a previously introduced CT-based technique, and were subtracted from each raw projection image. A CBCT image set was then reconstructed with an open source reconstruction toolkit (RTK). Conversion from the CBCT number to HU was performed by soft tissue-based shifting with reference to the plan CT. Passively scattered proton plans were simulated on the plan CT and corrected/uncorrected CBCT images using the XiO treatment planning system. For quantitative evaluation, water equivalent path length (WEPL) was compared in those treatment plans. Results: The scatter correction method significantly improved image quality and HU accuracy in the prostate case where large scatter artifacts were obvious. However, the correction technique showed limited effects on the thorax case that was associated with fewer scatter artifacts. Mean absolute WEPL errors from the plans with the uncorrected and corrected images were 1.3 mm and 5.1 mm in the thorax case and 13.5 mm and 3.1 mm in the prostate case. The prostate plan dose distribution of the corrected image demonstrated better agreement with the reference one than that of the uncorrected image. Conclusion: A priori CT-based CBCT scatter correction can reduce the proton dose calculation error when large scatter artifacts are involved. If scatter artifacts are low, an uncorrected CBCT image is also promising for proton dose calculation when it is calibrated with the soft-tissue based shifting.

60 APPLIED LIFE SCIENCES↗

MO-A-BRD-10: A Fast and Accurate GPU-Based Proton Transport Monte Carlo Simulation for Validating Proton Therapy Treatment Plans

Purpose: To build a GPU-based Monte Carlo (MC) simulation of proton transport with detailed modeling of elastic and non-elastic (NE) protonnucleus interactions, for use in a very fast and cost-effective proton therapy treatment plan verification system. Methods: Using the CUDA framework, we implemented kernels for the following tasks: (1) Simulation of beam spots from our possible scanning nozzle configurations, (2) Proton propagation through CT geometry, taking into account nuclear elastic and multiple scattering, as well as energy straggling, (3) Bertini-style modeling of the intranuclear cascade stage of NE interactions, and (4) Simulation of nuclear evaporation. To validate our MC, we performed: (1) Secondary particle yield calculations in NE collisions with therapeutically-relevant nuclei, (2) Pencil-beam dose calculations in homogeneous phantoms, (3) A large number of treatment plan dose recalculations, and compared with Geant4.9.6p2/TOPAS. A workflow was devised for calculating plans from a commercially available treatment planning system, with scripts for reading DICOM files and generating inputs for our MC. Results: Yields, energy and angular distributions of secondaries from NE collisions on various nuclei are in good agreement with the Geant4.9.6p2 Bertini and Binary cascade models. The 3D-gamma pass rate at 2%–2mm for 70–230 MeV pencil-beam dose distributions in water, soft tissue, bone and Ti phantoms is 100%. The pass rate at 2%–2mm for treatment plan calculations is typically above 98%. The net computational time on a NVIDIA GTX680 card, including all CPU-GPU data transfers, is around 20s for 1×10{sup 7} proton histories. Conclusion: Our GPU-based proton transport MC is the first of its kind to include a detailed nuclear model to handle NE interactions on any nucleus. Dosimetric calculations demonstrate very good agreement with Geant4.9.6p2/TOPAS. Our MC is being integrated into a framework to perform fast routine clinical QA of pencil-beam treatment plans. Hardware for such a system will cost under $5000. This work was funded in part by a grant from Varian Medical Systems, Inc.

61 RADIATION PROTECTION AND DOSIMETRY↗

The influence of patient positioning uncertainties in proton radiotherapy on proton range and dose distributions

Purpose: Proton radiotherapy allows radiation treatment delivery with high dose gradients. The nature of such dose distributions increases the influence of patient positioning uncertainties on their fidelity when compared to photon radiotherapy. The present work quantitatively analyzes the influence of setup uncertainties on proton range and dose distributions. Methods: Thirty-eight clinical passive scattering treatment fields for small lesions in the head were studied. Dose distributions for shifted and rotated patient positions were Monte Carlo-simulated. Proton range uncertainties at the 50%- and 90%-dose falloff position were calculated considering 18 arbitrary combinations of maximal patient position shifts and rotations for two patient positioning methods. Normal tissue complication probabilities (NTCPs), equivalent uniform doses (EUDs), and tumor control probabilities (TCPs) were studied for organs at risk (OARs) and target volumes of eight patients. Results: The authors identified a median 1σ proton range uncertainty at the 50%-dose falloff of 2.8 mm for anatomy-based patient positioning and 1.6 mm for fiducial-based patient positioning as well as 7.2 and 5.8 mm for the 90%-dose falloff position, respectively. These range uncertainties were correlated to heterogeneity indices (HIs) calculated for each treatment field (38% < R{sup 2} < 50%). A NTCP increase of more than 10% (absolute) was observed for less than 2.9% (anatomy-based positioning) and 1.2% (fiducial-based positioning) of the studied OARs and patient shifts. For target volumes TCP decreases by more than 10% (absolute) occurred in less than 2.2% of the considered treatment scenarios for anatomy-based patient positioning and were nonexistent for fiducial-based patient positioning. EUD changes for target volumes were up to 35% (anatomy-based positioning) and 16% (fiducial-based positioning). Conclusions: The influence of patient positioning uncertainties on proton range in therapy of small lesions in the human brain as well as target and OAR dosimetry were studied. Observed range uncertainties were correlated with HIs. The clinical practice of using multiple fields with smeared compensators while avoiding distal OAR sparing is considered to be safe.

60 APPLIED LIFE SCIENCES↗

Benchmarking of a treatment planning system for spot scanning proton therapy: Comparison and analysis of robustness to setup errors of photon IMRT and proton SFUD treatment plans of base of skull meningioma

Purpose: Base of skull meningioma can be treated with both intensity modulated radiation therapy (IMRT) and spot scanned proton therapy (PT). One of the main benefits of PT is better sparing of organs at risk, but due to the physical and dosimetric characteristics of protons, spot scanned PT can be more sensitive to the uncertainties encountered in the treatment process compared with photon treatment. Therefore, robustness analysis should be part of a comprehensive comparison between these two treatment methods in order to quantify and understand the sensitivity of the treatment techniques to uncertainties. The aim of this work was to benchmark a spot scanning treatment planning system for planning of base of skull meningioma and to compare the created plans and analyze their robustness to setup errors against the IMRT technique. Methods: Plans were produced for three base of skull meningioma cases: IMRT planned with a commercial TPS [Monaco (Elekta AB, Sweden)]; single field uniform dose (SFUD) spot scanning PT produced with an in-house TPS (PSI-plan); and SFUD spot scanning PT plan created with a commercial TPS [XiO (Elekta AB, Sweden)]. A tool for evaluating robustness to random setup errors was created and, for each plan, both a dosimetric evaluation and a robustness analysis to setup errors were performed. Results: It was possible to create clinically acceptable treatment plans for spot scanning proton therapy of meningioma with a commercially available TPS. However, since each treatment planning system uses different methods, this comparison showed different dosimetric results as well as different sensitivities to setup uncertainties. The results confirmed the necessity of an analysis tool for assessing plan robustness to provide a fair comparison of photon and proton plans. Conclusions: Robustness analysis is a critical part of plan evaluation when comparing IMRT plans with spot scanned proton therapy plans.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proton dose calculation on scatter-corrected CBCT image: Feasibility study for adaptive proton therapy

Purpose: To demonstrate the feasibility of proton dose calculation on scatter-corrected cone-beam computed tomographic (CBCT) images for the purpose of adaptive proton therapy. Methods: CBCT projection images were acquired from anthropomorphic phantoms and a prostate patient using an on-board imaging system of an Elekta infinity linear accelerator. Two previously introduced techniques were used to correct the scattered x-rays in the raw projection images: uniform scatter correction (CBCT{sub us}) and a priori CT-based scatter correction (CBCT{sub ap}). CBCT images were reconstructed using a standard FDK algorithm and GPU-based reconstruction toolkit. Soft tissue ROI-based HU shifting was used to improve HU accuracy of the uncorrected CBCT images and CBCT{sub us}, while no HU change was applied to the CBCT{sub ap}. The degree of equivalence of the corrected CBCT images with respect to the reference CT image (CT{sub ref}) was evaluated by using angular profiles of water equivalent path length (WEPL) and passively scattered proton treatment plans. The CBCT{sub ap} was further evaluated in more realistic scenarios such as rectal filling and weight loss to assess the effect of mismatched prior information on the corrected images. Results: The uncorrected CBCT and CBCT{sub us} images demonstrated substantial WEPL discrepancies (7.3 ± 5.3 mm and 11.1 ± 6.6 mm, respectively) with respect to the CT{sub ref}, while the CBCT{sub ap} images showed substantially reduced WEPL errors (2.4 ± 2.0 mm). Similarly, the CBCT{sub ap}-based treatment plans demonstrated a high pass rate (96.0% ± 2.5% in 2 mm/2% criteria) in a 3D gamma analysis. Conclusions: A priori CT-based scatter correction technique was shown to be promising for adaptive proton therapy, as it achieved equivalent proton dose distributions and water equivalent path lengths compared to those of a reference CT in a selection of anthropomorphic phantoms.

60 APPLIED LIFE SCIENCES↗