Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “polar vortex”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

The Vector Vortex Coronagraph: Sensitivity to Low-Order Aberrations, Central Obscuration, Chromaticism, and Polarization

The Vector Vortex Coronagraph is a phase-based coronagraph, one of the most efficient in terms of inner working angle, throughput, discovery space, contrast, and simplicity. Using liquid-crystal polymer technology, this new coronagraph has recently been the subject of lab demonstrations in the near-infrared, visible and was also used on sky at the Palomar observatory in the H and K bands (1.65 and 2.2 micrometers, respectively) to image the brown dwarf companion to HR 7672, and the three extasolar planets around HR 8799. However, despite these recent successes, the Vector Vortex Coronagraph is, as are most coronagraphs, sensitive to the central obscuration and secondary support structures, low-order aberrations (tip-tilt, focus, etc), bandwidth (chromaticism), and polarization when image-plane wavefront sensing is performed. Here, we consider in detail these sensitivities as a function of the topological charge of the vortex and design properties inherent to the manufacturing technology, and show that in practice all of them can be mitigated to meet specific needs.

large ground-based telescopes↗

Quantifying Subsidence in the 1999-2000 Arctic Winter Vortex

Quantifying the subsidence of the polar winter stratospheric vortex is essential to the analysis of ozone depletion, as chemical destruction often occurs against a large, altitude-dependent background ozone concentration. Using N2O measurements made during SOLVE on a variety of platforms (ER-2, in-situ balloon and remote balloon), the 1999-2000 Arctic winter subsidence is determined from N2O-potential temperature correlations along several N2O isopleths. The subsidence rates are compared to those determined in other winters, and comparison is also made with results from the SLIMCAT stratospheric chemical transport model.

Greenblatt, Jeffery B.↗

Airborne lidar observations of Arctic polar stratospheric clouds

Polar stratospheric clouds (PSC's) have been detected repeatedly during Arctic and Antarctic winters since 1978/1979 by the SAM II (Stratospheric Aerosol Measurement II) instrument aboard the NIMBUS-7 satellite. PSC's are believed to form when supercooled sulfuric acid droplets freeze, and subsequently grow by deposition of ambient water vapor as the local stratospheric temperature falls below the frost point. In order to study the characteristics of PSC's at higher spatial and temporal resolution than that possible from the satellite observations, aircraft missions were conducted within the Arctic polar night vortex in Jan. 1984 and Jan. 1986 using the NASA Langley Research Center airborne dual polarization ruby lidar system. A synopsis of the 1984 and 1986 PSC observations is presented illustrating short range spatial changes in cloud structure, the variation of backscatter ratio with temperature, and the depolarization characterics of cloud layers. Implications are noted with regard to PSC particle characteristics and the physical process by which the clouds are thougth to form.

Poole, L. R.↗

The Effect of Dust on the Martian Polar Vortices

The influence of atmospheric dust on the dynamics and stability of the martian polar vortices is examined, through analysis of Mars Climate Sounder observations and MarsWRF general circulation model simulations. We show that regional and global dust storms produce transient vortex warming events that partially or fully disrupt the northern winter polar vortex for brief periods. Increased atmospheric dust heating alters the Hadley circulation and shifts the downwelling branch of the circulation poleward, leading to a disruption of the polar vortex for a period of days to weeks. Through our simulations, we find this effect is dependent on the atmospheric heating rate, which can be changed by increasing the amount of dust in the atmosphere or by altering the dust optical properties (e.g., single scattering albedo). Despite this, our simulations show that some level of atmospheric dust is necessary to produce a distinct northern hemisphere winter polar vortex.

Guzewich, Scott D.↗

Significance of semiannual waves in the mesospheric zonal wind and evidence of influence by the geomagnetic field

The recently described polar semiannual oscillations in zonal wind can explain midwinter weakening of the polar winter vortex and the relatively short stratospheric and mesospheric summer easterlies. This explanation implies that stratospheric sudden warmings may be caused or affected by the polar semiannual oscillation. Two potential physical mechanisms (not mutually exclusive) for the oscillation are presented: planetary wave action and changes in the radiation field. Radiation absorption changes are suggested to result from changes in ozone concentration during magnetic storms. Contours of amplitude of both the polar and tropical semiannual wind oscillations are more nearly congruent with geomagnetic than with geographic latitude.

Belmont, A. D.↗

Arctic chemical Ozone Loss Observed by the AROTEL Instrument during the SOLVE Campaign, December 1999 - March 2000

During the winter of 1999-2000, the AROTEL instrument was deployed on the NASA DC-8 at Kiruna, Sweden for the SAGE III Ozone Loss Validation Experiment (SOLVE). Measurements of ozone, temperature and aerosols were made on 18 local science flights from December to March. Extremely low temperatures were observed throughout most of the Arctic vortex and polar stratospheric clouds were observed throughout the Arctic area during January. Significant ozone loss was measured after the sun began to rise on the vortex area in February. Ozone mixing ratios as low as 800 ppbv were observed during flights in March.

McGee, Thomas J.↗

Polar clearing in the Venus clouds observed from the Pioneer Orbiter

High data rate, high resolution observations made by the Pioneer Venus 1 Orbiter of Venus clouds in the polar region are reported. Data obtained by the Pioneer IR radiometer reveal the presence of a localized, very warm (260 K) feature at about 80 deg N, 359 deg E, indicating a cloud height differential of about 15 km between the depressed, but not totally absent, cloud level indicated by the temperature peak and the surrounding cold zones. The observations are considered to constitute new evidence for the presence of strong atmospheric subsidence near the poles, fitting a model of vortex-type polar circulation. Implications of the observations for the single cell model of the Venus stratosphere are noted.

Taylor, F. W.↗

Interhemispheric comparison of atmospheric circulation features as evaluated from Nimbus satellite data

General circulation parameters in the Northern Hemisphere are calculated using atmospheric thermal structure obtained from Nimbus 3 SIRS multi-channel radiance information. The thermal structure up to 10 mb is obtained by using a regression technique with thickness between pressure levels as the dependent variable. General circulation parameters calculated on a daily basis include zonal and eddy available potential energy, and zonal and eddy kinetic energy. A second set of calculations is performed using National Meteorological Center grid data. A comparison of the two sets of calculations indicates that, although the energies calculated from the SIRS-derived structure underestimate the actual energies, maxima, minima, and trends are well identified. An example of mid-stratospheric energy changes during a breakdown of the polar-night vortex is also given.

Reiter, E. R.↗

Global transport calculations with an equivalent barotropic system

Transport properties of the two-dimensional equations governing equivalent barotropic motion are investigated on the sphere. This system has ingredients such as forcing, equivalent depth, and thermal dissipation explicitly represented, and takes into account compression effects associated with vertical motion along isentropic surfaces. Horizontal transport properties of this system are investigated under adiabatic and diabatic conditions for different forms of dissipation, and over a range of resolutions. It is shown that forcing represetative of time-mean and amplified conditions at 10 mb leads to the behavior typical of observations at this level. The displacement of the polar night vortex and its distortion into a comma shape are evident, as is irreversible mixing under sufficiently strong forcing amplitude. It is shown that thermal dissipation influences the behavior significantly by inhibiting the amplification of unstable eddies and thereby the horizontal stirring of air.

Salby, Murry L.↗

An observational study of the ozone dilution effect: Ozone transport in the austral spring stratosphere

In a previous observational analysis, Atkinson et al (1989) ascribed a sudden decrease in Southern Hemisphere midlatitude total ozone during December 1987 to an 'ozone dilution effect' brought about by the breakup of the polar stratospheric vortex at that time. A question alluded to but unanswered by that study was the degree to which the observed total ozone decrease might have been caused by the quasi-horizontal equatorward transport of 'ozone hold' air from within the vortex, and to what degree by the vertical advection from lower levels of air naturally low in ozone, a dynamical adjustment process which must accompany the equatorward outbreak of a discrete high-latitude airmass. In the present study, analyses of Ertel potential vorticity, TOMS total ozone, and SAGE and ozone sonde vertical profile data are employed using a novel technique to examine the 1987 event in greater detail, to answer this question. Recent progress is then reported in refining the technique and extending the investigation to examine the dynamical evolution of the austral spring stratosphere during other recent years, to shed more light on the precise nature, frequency, and severity of such 'ozone dilution' events, and the effect that this process may have on long term ozone behavior in the Southern Hemisphere.

Atkinson, Roger J.↗

Dynamical and Chemical Behavior of the Lower Stratosphere and Interactions with the Troposphere

Equivalent-barotropic calculations, in tandem with Lagrangian analyses, reveal how changes of total ozone follow from vertical and horizontal transport by planetary waves. Those calculations also throw light on how diabatic motions comprising the Brewer-Dobson circulation develop from quasi-horizontal advection by planetary waves. Potential temperature along a material surface indicates organized subsidence inside the polar-night vortex, resembling tracer observations from UARS. Lagrangian histories illustrate that this sinking motion follows in large part from parcels being driven out of thermodynamic equilibrium by planetary waves, especially at high latitudes. Irreversible heat transfer then produces a net drift of air across isentropic surfaces as parcels orbit about the displaced vortex. By driving mean-meridional overturning in the stratosphere, this downward drift is ultimately responsible for transferring ozone from the tropics to the extratropical lower stratosphere. It also introduces horizontal structure into the distribution of total ozone, which surfaces clearly in ozone trends. High-resolution global cloud imagery constructed from 6 satellites simultaneously observing the Earth was used to investigate the spectrum of equatorial waves generated by tropical convection and propagating vertically into the stratosphere. The results indicate that temperature variability is dominated by planetary-scale equatorial waves like the Kelvin mode, which agrees with satellite observations of the tropical stratosphere. However, the Kelvin mode accounts for only about 30 - 50% of the eastward momentum flux radiating into the stratosphere, the remainder coming from gravity waves. An algorithm was developed to determine 3-dimensional atmospheric motion from satellite tracer measurements. Based on Lagrangian constraints, the algorithm circumvents limitations of the traditional scheme for inferring motion from temperature measurements and determines the circulation in the tropics as reliably as elsewhere. A study of deep convection revealed that the highest towers (those penetrating into stratospheric air and controlling tropopause height and composition through convective mixing) occur in close association with the diurnal cycle of convection. Clouds colder than 220 K develop almost entirely in association with the diurnal cycle of convection over tropical landmasses and substantially in association with it even over maritime regions.

Salby, Murry L.↗

2021 Antarctic Ozone Hole [in “State of the Climate in 2021"]

The 2021 Antarctic ozone hole was the 13th largest in 42 years of satellite observations since 1979, with an area of 23.34 × 106 km 2 (the average area for 7 September–13 October) and a minimum daily total ozone column of 92 DU. The 2021 polar stratospheric vortex was stable with consistently cold temperatures that created favorable conditions for ozone depletion. The meteorological conditions and seasonal development of the ozone hole in 2021 were similar to those in 2020. Weaker-than-usual amplitudes of planetary scale Rossby waves in the September–October period helped maintain a strong vortex and led to below-average Antarctic ozone columns in late austral spring and early summer.

Natalya A Kramarova↗

Why Do Antarctic Ozone Recovery Trends Vary?

We use satellite ozone records and Global Modeling Initiative (GMI) chemistry transport model (CTM) simulations integrated with MERRA2 meteorology to identify a metric that accurately captures the trend in Antarctic ozone attributable to the decline in ozone depleting substances (ODSs). The GMI CTM Baseline simulation with realistically varying ODS levels closely matches observed interannual to decadal scale variations in Antarctic September ozone over the past 4 decades. The expected increase or recovery trend is obtained from the differences between the Baseline simulation and one with identical meteorology and fixed 1995 ODS levels. The differences show that vortex-averaged column O3 has the greatest sensitivity to ODS change from 1-20 Sep. The observed vortex-averaged column O3 during this period produces a trend consistent with the expected recovery attributable to ODS decline. Trends from dates after 20 Sep have smaller sensitivity to ODS decline and are more uncertain due to transport variability. Simulations show that the greatest decrease in O3 loss (i.e., recovery) occurs inside the vortex near the edge. The polar cap metrics have vortex size-dependent bias and do not consistently sample this region. Because the 60-90oS 220 DU O3 mass deficit (OMD) metric does not sample the edge region, its trend is lower than the expected trend; this is improved by area weighting. The 250 DU OMD metric samples more of the edge region, which increases its trend. Approximately 25% of the September Antarctic O3 increase is due to higher O3 levels in June prior to winter depletion.

Antarctic ozone↗