Design and performance evaluation of a cryogenic condenser for an in-pile experiment

An apparatus was designed to enable in-pile irradiation of materials in liquid hydrogen at cryogenic temperatures. One of the principal components of this apparatus was a horizontal tube condenser. The performance of the condenser was evaluated by running a liquid-nitrogen prototype of the apparatus at heat loads comparable to or greater than those expected during the irradiation. The test showed that the condenser was capable of handling the design heat load and that the design procedure was sound.

Graham, R. W.↗

A Pulsar-Inspired Timing Framework for Power System: Optimization and Performance Evaluation

Due to their excellent stability, neutron pulsar stars are considered promising candidate timing sources for power system applications. However, the complexity of pulsar signals necessitates advanced processing algorithms to provide accurate timing references. This paper presents the foundational framework for pulsar signal processing, serving as the basis for further optimization. To enhance the timing accuracy and computation efficiency in pulsar period searches, three algorithms are proposed as the initial optimization step: wavelet de-noising, fast folding, and cross-correlation for profile evaluation. Wavelet de-noising improves signal-to-noise ratio (SNR) by 36%–70%. Fast folding reduces computation time from hundreds of seconds to mere milliseconds. Cross-correlation works better than traditional SNR-based methods by effectively identifying the optimal period. The performance of the proposed algorithms is evaluated using observation data from telescopes. Together, these algorithms significantly improve pulsar timing performance, reducing the error of the Pulse Per Second (PPS) signal from hundreds to tens of microseconds.

Wu, Ori [ORNL] (ORCID:0000000326723410)↗

Performance evaluation of the Engineering Analysis and Data Systems (EADS) 2

The Engineering Analysis and Data System (EADS)II (1) was installed in March 1993 to provide high performance computing for science and engineering at Marshall Space Flight Center (MSFC). EADS II increased the computing capabilities over the existing EADS facility in the areas of throughput and mass storage. EADS II includes a Vector Processor Compute System (VPCS), a Virtual Memory Compute System (CFS), a Common Output System (COS), as well as Image Processing Station, Mini Super Computers, and Intelligent Workstations. These facilities are interconnected by a sophisticated network system. This work considers only the performance of the VPCS and the CFS. The VPCS is a Cray YMP. The CFS is implemented on an RS 6000 using the UniTree Mass Storage System. To better meet the science and engineering computing requirements, EADS II must be monitored, its performance analyzed, and appropriate modifications for performance improvement made. Implementing this approach requires tool(s) to assist in performance monitoring and analysis. In Spring 1994, PerfStat 2.0 was purchased to meet these needs for the VPCS and the CFS. PerfStat(2) is a set of tools that can be used to analyze both historical and real-time performance data. Its flexible design allows significant user customization. The user identifies what data is collected, how it is classified, and how it is displayed for evaluation. Both graphical and tabular displays are supported. The capability of the PerfStat tool was evaluated, appropriate modifications to EADS II to optimize throughput and enhance productivity were suggested and implemented, and the effects of these modifications on the systems performance were observed. In this paper, the PerfStat tool is described, then its use with EADS II is outlined briefly. Next, the evaluation of the VPCS, as well as the modifications made to the system are described. Finally, conclusions are drawn and recommendations for future worked are outlined.

Debrunner, Linda S.↗

Performance evaluation of a Doppler radar system for wind shear detection

Nonlinear stochastic differential equations are used to model wind shear, and extended Kalman filters are used to generate state estimates from measurements received from a Doppler radar onboard an aircraft. Likelihood-ratio tests are then used to detect the presence of wind shear. The performance of the system is evaluated by deriving theoretical expressions for the false alarm and miss error probabiilties. The approach uses a Fokker-Planck equation. The overall methodology is general and should be of interest in other applications.

Khalaf, Camille S.↗

Performance Evaluation of a High Bandwidth Liquid Fuel Modulation Valve for Active Combustion Control

At the NASA Glenn Research Center, a characterization rig was designed and constructed for the purpose of evaluating high bandwidth liquid fuel modulation devices to determine their suitability for active combustion control research. Incorporated into the rig s design are features that approximate conditions similar to those that would be encountered by a candidate device if it were installed on an actual combustion research rig. The characterized dynamic performance measures obtained through testing in the rig are planned to be accurate indicators of expected performance in an actual combustion testing environment. To evaluate how well the characterization rig predicts fuel modulator dynamic performance, characterization rig data was compared with performance data for a fuel modulator candidate when the candidate was in operation during combustion testing. Specifically, the nominal and off-nominal performance data for a magnetostrictive-actuated proportional fuel modulation valve is described. Valve performance data were collected with the characterization rig configured to emulate two different combustion rig fuel feed systems. Fuel mass flows and pressures, fuel feed line lengths, and fuel injector orifice size was approximated in the characterization rig. Valve performance data were also collected with the valve modulating the fuel into the two combustor rigs. Comparison of the predicted and actual valve performance data show that when the valve is operated near its design condition the characterization rig can appropriately predict the installed performance of the valve. Improvements to the characterization rig and accompanying modeling activities are underway to more accurately predict performance, especially for the devices under development to modulate fuel into the much smaller fuel injectors anticipated in future lean-burning low-emissions aircraft engine combustors.

Saus, Joseph R.↗

Indoor thermal performance evaluation of Daystar solar collector

The test procedures used and results obtained from a test program to obtain thermal performance data on a Daystar Model 21B, S/N 02210, Unit 2, liquid solar collector under simulated conditions are described. The test article is a flat plate solar collector using liquid as a heat transfer medium. The absorber plate is copper and coated with black paint. Between the tempered low iron glass and absorber plate is a polycarbonate trap used to suppress convective heat loss. The collector incorporates a convector heat dump panel to limit temperature excursions during stagnation. The following tests were conducted: (1) collector thermal efficiency; (2) collector time constant; (3) collector incident angle modifier; (4) collector heat loss coefficient; and (5) collector stagnation.

Shih, K., Sr.↗

Performance Evaluation of Drain Water Heat Recovery Exchangers for Heat Pump Water Heaters

Water heating constitutes approximately 18% of energy consumption and is the second largest energy expenses in United States homes. Heat pump water heaters (HPWHs) are energy efficient technologies with lower carbon footprints as compared to conventional water heating technologies, such as gas and electrical resistance heaters. The performance of water-source HPWHs can be improved by recovering heat from blackwater using drain heat recovery heat exchangers. Depending on water draw patterns of single family and multifamily residences, the operation and heat transfer performance of these heat exchangers are highly transient. This paper examines the thermo-hydraulic performance of a drain heat recovery heat exchanger during its transient and steady-state operations. The heat recovery performance of the exchanger was evaluated at different inlet temperatures and flow rates ranging from 9°C to 36°C and 0.03 kg/s to 0.28 kg/s, respectively. The obtained effectiveness varies from 45%–85% depending on the operating conditions. The test facility, steady-state and transient experimental procedures are reported in detail. Further, the effect of operating conditions on the effectiveness is discussed. The experimental approach and results of the study will provide insights into the transient operation of drain recovery heat exchangers as well as, guide sizing for various steady state conditions.

Krishnan, Easwaran↗

A Performance Evaluation of NACK-Oriented Protocols as the Foundation of Reliable Delay- Tolerant Networking Convergence Layers

Delay-Tolerant Networking (DTN) is an active area of research in the space communications community. DTN uses a standard layered approach with the Bundle Protocol operating on top of transport layer protocols known as convergence layers that actually transmit the data between nodes. Several different common transport layer protocols have been implemented as convergence layers in DTN implementations including User Datagram Protocol (UDP), Transmission Control Protocol (TCP), and Licklider Transmission Protocol (LTP). The purpose of this paper is to evaluate several stand-alone implementations of negative-acknowledgment based transport layer protocols to determine how they perform in a variety of different link conditions. The transport protocols chosen for this evaluation include Consultative Committee for Space Data Systems (CCSDS) File Delivery Protocol (CFDP), Licklider Transmission Protocol (LTP), NACK-Oriented Reliable Multicast (NORM), and Saratoga. The test parameters that the protocols were subjected to are characteristic of common communications links ranging from terrestrial to cis-lunar and apply different levels of delay, line rate, and error.

Iannicca, Dennis↗

Solar energy system performance evaluation. Seasonal report for Colt Pueblo, Pueblo, Colorado

The Colt-Pueblo solar energy system, designed to provide space heating and hot water preheating, is described and its operational performance for a 12 month period from February 1979 through January 1980 is evaluated. The space heating subsystem met 31 percent of the measured space heating load which was close to the expected 34 percent solar fraction. Although the hot water solar fraction was 79 percent, the overall energy saving capability was reduced because of the low hot water demand. The measured heating subsystem performance would have improved considerably if the uncontrolled losses primarily from transport piping could have been reduced to an inconsequential level. Fossil energy savings of 70.31 million BTUs are estimated.

Source record↗

Characteristic Performance Evaluation of a new SAGe Well Detector for Small and Large Sample Geometries

Environmental scientific research requires a detector that has sensitivity low enough to reveal the presence of any contaminant in the sample at a reasonable counting time. Canberra developed the germanium detector geometry called Small Anode Germanium (SAGe) Well detector, which is now available commercially. The SAGe Well detector is a new type of low capacitance germanium well detector manufactured using small anode technology capable of advancing many environmental scientific research applications. The performance of this detector has been evaluated for a range of sample sizes and geometries counted inside the well, and on the end cap of the detector. The detector has energy resolution performance similar to semi-planar detectors, and offers significant improvement over the existing coaxial and Well detectors. Energy resolution performance of 750 eV Full Width at Half Maximum (FWHM) at 122 keV γ-ray energy and resolution of 2.0 - 2.3 keV FWHM at 1332 keV γ-ray energy are guaranteed for detector volumes up to 425 cm{sup 3}. The SAGe Well detector offers an optional 28 mm well diameter with the same energy resolution as the standard 16 mm well. Such outstanding resolution performance will benefit environmental applications in revealing the detailed radionuclide content of samples, particularly at low energy, and will enhance the detection sensitivity resulting in reduced counting time. The detector is compatible with electric coolers without any sacrifice in performance and supports the Canberra Mathematical efficiency calibration method (In situ Object Calibration Software or ISOCS, and Laboratory Source-less Calibration Software or LABSOCS). In addition, the SAGe Well detector supports true coincidence summing available in the ISOCS/LABSOCS framework. The improved resolution performance greatly enhances detection sensitivity of this new detector for a range of sample sizes and geometries counted inside the well. This results in lower minimum detectable concentrations compared to Traditional Well detectors. The SAGe Well detectors are compatible with Marinelli beakers and compete very well with semi-planar and coaxial detectors for large samples in many applications. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal hydraulic analysis of the AFIP-7 irradiation test in the Advanced test Reactor – Model correlation and performance evaluation

We report as a system level code, RELAP5 is widely used in the nuclear field for the reactor hydraulic analysis. In the component/experimental level, it is frequently employed as well. This paper demonstrates that the RELAP5 flow simulation of the AFIP-7 irradiation experiment which has a complicated 3D geometry/flow path deviates by ~28% from the flow evaluation through a computational fluid dynamics (CFD) simulation, which has been validated against a flow test performed at Oregon State University. Thermal safety compliance analysis of an experiment planned to be irradiated in the Advanced Test Reactor is usually performed using the finite element analysis code, Abaqus. This research reveals the disadvantages of the Abaqus simulation in the flow instability and departure from nucleate boiling evaluations via a conjugate heat transfer analysis of the AFIP-7 irradiation experiment. As a result, a detailed CFD simulation is suggested for irradiation experiments with complicated flow paths, rather than a simplified RELAP5 simulation or hand calculations. The validated simulation approach will be integrated with the Boehmite correlations to investigate the oxide growth prediction on the fuel cladding in Part II of this research.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Brookfield Homes Passive House Performance Evaluation

TO4 3.1.3: Brookfield Homes Short-Term Results TO5 3.1.3: Brookfield Passive House Monitoring To further define its market position on high performance homebuilding, Brookfield worked with IBACOS and the Building America program to design and construct a Passive House (PH) certified model home in Denver, CO to evaluate advanced building technologies and to use as a marketing tool for potential homebuyers. Brookfield used a new architect and a new floor plan as a standard production model and constructed it to the PH standard as an upgrade option. This PH was completely built and certified in August 2013.

Array↗