Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “particle filter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

405 records · Page 23

Jefferson Laboratory C100 Superconducting Radio-Frequency Cavity Fault Data, 2020

The dataset was created to train machine learning models for the task of identifying the (1) cavity and (2) fault type from C100-type cryomodules at the Thomas Jefferson National Accelerator Facility (Jefferson Lab), thereby replacing the time-consuming efforts of a subject matter expert. Superconducting radio-frequency (SRF) cavity trips represent a significant source of accelerator downtime. Real-time – rather than post-mortem – identification of the offending cavity and classification of the fault type would give control room operators valuable feedback for corrective action planning. The anticipated benefit is increased beam-on-target time for users and provides performance metrics that can be used to improve future cavity designs. A series of 17 RF signals are recorded for each of the 8 cavities in a C100 cryomodule every time a cavity trips. These time-series signals are written to file using a specially designed data acquisition system. The dataset represents fault events recorded during Continuous Electron Beam Accelerator Facility (CEBAF) beam operations between January 18, 2019 and March 9, 2020. The following filtering steps were applied to collected data; (1) only 4 of the 17 signals per cavity are retained (GMES, GASK, CRFP, DETA2) (2) only events with data from each of the eight cavities in the cryomodule are kept, (3) only events that were sampled at 5 kHz were kept, (4) events from cryomodule 0L04 were neglected, (5) events occurring between February 4, 3PM and February 5, 12PM were neglected. As a result of preprocessing, the dataset is comprised of 2,375 unique events. The full dataset is comprised of three files: features.csv, cavity_labels.csv, fault_labels.csv. Each instance in faults.csv includes a timestamp (“date_time”), a label for the cryomodule which experienced the trip (“zone_label”), and 192 features (“feature_1”, “feature_2”... “feature_192”). The features correspond to 6 autoregressive features for each of 4 signals per cavity for each of the 8 cavities (6 × 4 signals/cavity × 8 cavities/cryomodule = 192). To deal with the large variation of signal amplitudes, time-series standardization via the z-score (standard score) function was applied prior to computing the features. For each instance, there is an associated label for the (1) cavity which faulted first (cavity_labels.csv) and (2) the type of fault that caused the trip (fault_labels.csv). The cavity identification can take values of [0, 1, 2, 3, 4, 5, 6, 7, 8] and the fault type can take values of [‘Microphonics’, ‘Quench_100ms’, ‘Controls_Fault’, ‘E_Quench’, ‘Quench_3ms’, ‘Single_Cav_Turn_Off’ , ‘Heat_Riser_Choke’, ‘Multi_Cav_Turn_Off’].

43 PARTICLE ACCELERATORS↗

Observation of radon mitigation in MicroBooNE by a liquid argon filtration system

We report the MicroBooNE liquid argon time projection chamber (LArTPC) maintains a high level of liquid argon purity through the use of a filtration system that removes electronegative contaminants in continuously-circulated liquid, recondensed boil off, and externally supplied argon gas. We use the MicroBooNE LArTPC to reconstruct MeV-scale radiological decays. Using this technique we measure the liquid argon filtration system's efficacy at removing radon. This is studied by placing a 500 kBq 222 Rn source upstream of the filters and searching for a time-dependent increase in the number of radiological decays in the LArTPC. In the context of two models for radon mitigation via a liquid argon filtration system, a slowing mechanism and a trapping mechanism, MicroBooNE data supports a radon reduction factor of greater than 97% or 99.999%, respectively. Furthermore, a radiological survey of the filters found that the copper-based filter material was the primary medium that removed the 222 Rn. This is the first observation of radon mitigation in liquid argon with a large-scale copper-based filter and could offer a radon mitigation solution for future large LArTPCs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First results of the CAST-RADES haloscope search for axions at 34.67 μ eV

We present results of the Relic Axion Dark-Matter Exploratory Setup (RADES), a detector which is part of the CERN Axion Solar Telescope (CAST), searching for axion dark matter in the 34.67 μeV mass range. A radio frequency cavity consisting of 5 sub-cavities coupled by inductive irises took physics data inside the CAST dipole magnet for the first time using this filter-like haloscope geometry. An exclusion limit with a 95% credibility level on the axion-photon coupling constant of g aγ ≳ 4 × 10 -13 GeV -1 over a mass range of 34.6738 μeV < m a < 34.6771 μeV is set. This constitutes a significant improvement over the current strongest limit set by CAST at this mass and is at the same time one of the most sensitive direct searches for an axion dark matter candidate above the mass of 25 μeV. The results also demonstrate the feasibility of exploring a wider mass range around the value probed by CAST-RADES in this work using similar coherent resonant cavities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Temperature Profile of a Stellar Flare Using Differential Chromatic Refraction

We present the first derivation of a stellar flare temperature profile from single-band photometry. Stellar flare DWF 030225.574−545707.45129 was detected in 2015 by the Dark Energy Camera as part of the Deeper, Wider, Faster program. The brightness (Δm g = −6.12) of this flare, combined with the high air mass (1.45 ≲ X ≲ 1.75) and blue filter (DES g, 398–548 nm) in which it was observed, provided ideal conditions to measure the zenithward apparent motion of the source due to differential chromatic refraction (DCR) and, from that, infer the effective temperature of the event. We model the flare’s spectral energy distribution as a blackbody to produce the constraints on flare temperature and geometric properties derived from single-band photometry. We additionally demonstrate how simplistic assumptions on the flaring spectrum, as well as on the evolution of flare geometry, can result in solutions that overestimate the effective temperature. Exploiting DCR enables studying chromatic phenomena with ground-based astrophysical surveys, and stellar flares on M dwarfs are a particularly enticing target for such studies due to their ubiquity across the sky and the heightened color contrast between their red quiescent photospheres and the blue flare emission. Our novel method will enable similar temperature constraints for a large sample of objects in upcoming photometric surveys like the Vera C. Rubin Legacy Survey of Space and Time.

Clarke, Riley W. [University of Delaware, Newark, ↗

Generalizing mkFit and its Application to HL-LHC

mkFit is an implementation of the Kalman filter-based track reconstruction algorithm that exploits both thread- and data-level parallelism. In the past few years the project transitioned from the R&D phase to deployment in the Run-3 offline workflow of the CMS experiment. The CMS tracking performs a series of iterations, targeting reconstruction of tracks of increasing difficulty after removing hits associated to tracks found in previous iterations. mkFit has been adopted for several of the tracking iterations, which contribute to the majority of reconstructed tracks. When tested in the standard conditions for production jobs, speedups in track pattern recognition are on average of the order of 3.5x for the iterations where it is used (3-7x depending on the iteration). Multiple factors contribute to the observed speedups, including vectorization and a lightweight geometry description, as well as improved memory management and single precision. Efficient vectorization is achieved with both the icc and the gcc (default in CMSSW) compilers and relies on a dedicated library for small matrix operations, Matriplex, which has recently been released in a public repository. While the mkFit geometry description already featured levels of abstraction from the actual Phase-1 CMS tracker, several components of the implementations were still tied to that specific geometry. We have further generalized the geometry description and the configuration of the run-time parameters, in order to enable support for the Phase-2 upgraded tracker geometry for the HL-LHC and potentially other detector configurations. The implementation strategy and high-level code changes required for the HL-LHC geometry are presented. Speedups in track building from mkFit imply that track fitting becomes a comparably time consuming step of the tracking chain.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A portable and monoenergetic 24 keV neutron source based on 124Sb-9Be photoneutrons and an iron filter

A portable monoenergetic 24 keV neutron source based on the 124Sb-9Be photoneutron reaction and an iron filter has been constructed and characterized. The coincidence of the neutron energy from SbBe and the low interaction cross-section with iron (mean free path up to 29 cm) makes pure iron specially suited to shield against gamma rays from 124Sb decays while letting through the neutrons. To increase the 124Sb activity and thus the neutron flux, a >1 GBq 124Sb source was produced by irradiating a natural Sb metal pellet with a high flux of thermal neutrons in a nuclear reactor. The design of the source shielding structure makes for easy transportation and deployment. A hydrogen gas proportional counter is used to characterize the neutrons emitted by the source and a NaI detector is used for gamma background characterization. At the exit opening of the neutron beam, the characterization determined the neutron flux in the energy range 20–25 keV to be 6.00±0.30 neutrons per cm2 per second and the total gamma flux to be 245±8 gammas per cm2 per second (numbers scaled to 1 GBq activity of the 124Sb source). A liquid scintillator detector is demonstrated to be sensitive to neutrons with incident kinetic energies from 8 to 17 keV, so it can be paired with the source as a backing detector for neutron scattering calibration experiments. This photoneutron source provides a good tool for in-situ low energy nuclear recoil calibration for dark matter experiments and coherent elastic neutrino-nucleus scattering experiments.

Dark Matter detectors (WIMPs, axions, etc.)↗

Interacting dark sector within ETHOS: Cosmological constraints from SPT cluster abundance with DES and HST weak lensing data

We use galaxy cluster abundance measurements from the South Pole Telescope enhanced by multicomponent matched filter confirmation and complemented with mass information obtained using weak-lensing data from Dark Energy Survey Year 3 (DES Y3) and targeted Hubble Space Telescope observations for probing deviations from the cold dark matter paradigm. Concretely, we consider a class of dark sector models featuring interactions between dark matter (DM) and a dark radiation (DR) component within the framework of the effective theory of structure formation (ETHOS). We focus on scenarios that lead to power suppression over a wide range of scales, and thus can be tested with data sensitive to large scales, as realized, for example, for DM–DR interactions following from an unbroken non-Abelian 𝑆⁢𝑈⁡(𝑁) gauge theory (interaction rate with power-law index 𝑛 = 0 within the ETHOS parametrization). Cluster abundance measurements are mostly sensitive to the amount of DR interacting with DM, parametrized by the ratio of DR temperature to the cosmic microwave background (CMB) temperature, 𝜉 DR = 𝑇 DR /𝑇 CMB . We find an upper limit 𝜉 DR < 17% at 95% credibility. When the cluster data are combined with Planck 2018 CMB data along with baryon acoustic oscillation (BAO) measurements we find 𝜉 DR < 10%, corresponding to a limit on the abundance of interacting DR that is around 3 times tighter than that from CMB + BAO data alone. We also discuss the complementarity of weak lensing informed cluster abundance studies with probes sensitive to smaller scales, explore the impact on our analysis of massive neutrinos, and comment on a slight preference for the presence of a nonzero interacting DR abundance, which enables a physical solution to the 𝑆 8 tension.

79 ASTRONOMY AND ASTROPHYSICS↗

Prototype acoustic positioning system for the Pacific Ocean Neutrino Experiment

We present the design and initial performance characterization of the prototype acoustic positioning system intended for the Pacific Ocean Neutrino Experiment. It comprises novel piezo-acoustic receivers with dedicated filtering- and amplification electronics installed in P-ONE instruments and is complemented by a commercial system comprised of cabled and autonomous acoustic pingers for sub-sea installation manufactured by Sonardyne Ltd. We performed an in-depth characterization of the acoustic receiver electronics and their acoustic sensitivity when integrated into P-ONE pressure housings. These show absolute sensitivities of up to -125 dB re V2/μPa2 in a frequency range of 10–40 kHz. We furthermore conducted a positioning measurement campaign in the ocean by deploying three autonomous acoustic pingers on the seafloor, as well as a cabled acoustic interrogator and a P-ONE prototype module deployed from a ship. Using a simple peak-finding detection algorithm, we observe high accuracy in the tracking of relative ranging times at approximately 230–280 μs at distances of up to 1600 m, which is sufficient for positioning detectors in a cubic-kilometer detector and which can be further improved with more involved detection algorithms. The tracking accuracy is further confirmed by independent ranging of the Sonardyne system and closely follows the ship's drift in the wind measured by GPS. The absolute positioning shows the same tracking accuracy with its absolute precision only limited by the large uncertainties of the deployed pinger positions on the seafloor.

Data analysis↗

Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission

We present an overview of the design and in-flight performance of the Resolve soft X-ray spectrometer on the X-Ray Imaging and Spectroscopy Mission that was successfully launched on September 7, 2023, on a JAXA H-IIA rocket from the Tanegashima Space Center of Japan. The instrument has a 36-pixel array of microcalorimeters, 35 of which are at the focus of a high-throughput grazing-incidence X-ray mirror. The instrument has achieved its required operational base temperature of 0.05 K and a spectral resolution of 4.5 eV (FWHM) at 6 keV. The cooling chain was designed to provide a lifetime of at least 3 years in orbit and operate with and without liquid helium to provide redundancy and the longest operational lifetime for the instrument. Early indications are that the cryogen lifetime may reach 6 years with a cryogen-free mode thereafter. A series of onboard X-ray calibration sources produces energy scale calibration lines simultaneously while observing celestial sources. The overall design and in-flight performance of Resolve are described.

Astronomy and AstroPhysics↗