Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “outdoor testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Human Response to Simulated Low-Intensity Sonic Booms

NASA's High Speed Research (HSR ) program in the 1990s was intended to develop a technology base for a future High-Speed Civil Transport (HSCT). As part of this program, the NASA Langley Research Center sonic boom simulator (SBS) was built and used for a series of tests on subjective response to sonic booms. At the end of the HSR program, an HSCT was deemed impractical, but since then interest in supersonic flight has reawakened, this time focusing on a smaller aircraft suitable for a business jet. To respond to this interest, the Langley sonic boom simulator has been refurbished. The upgraded computer-controlled playback system is based on an SGI O2 computer, in place of the previous DEC MicroVAX. As the frequency response of the booth is not flat, an equalization filter is required. Because of the changes made during the renovation (new loudspeakers), the previous equalization filter no longer performed as well as before, so a new equalization filter has been designed. Booms to be presented in the booth are preprocessed using the filter. When the preprocessed signals are presented into the booth and measured with a microphone, the results are very similar to the intended shapes. Signals with short rise times and sharp "corners" are observed to have a small amount of "ringing" in the response. During the HSR program a considerable number of subjective tests were completed in the SBS. A summary of that research is given in Leatherwood et al. (Individual reports are available at http://techreports.larc.nasa.gov/ltrs/ltrs.html.) Topics of study included shaped sonic booms, asymmetrical booms, realistic (recorded) boom waveforms, indoor and outdoor booms shapes, among other factors. One conclusion of that research was that a loudness metric, like the Stevens Perceived Level (PL), predicted human reaction much more accurately than overpressure or unweighted sound pressure level. Structural vibration and rattle were not included in these studies.

Sullivan, Brenda M.↗

Development and Calibration of a Field-Deployable Microphone Phased Array for Propulsion and Airframe Noise Flyover Measurements

A new aeroacoustic measurement capability has been developed consisting of a large channelcount, field-deployable microphone phased array suitable for airframe noise flyover measurements for a range of aircraft types and scales. The array incorporates up to 185 hardened, weather-resistant sensors suitable for outdoor use. A custom 4-mA current loop receiver circuit with temperature compensation was developed to power the sensors over extended cable lengths with minimal degradation of the signal to noise ratio and frequency response. Extensive laboratory calibrations and environmental testing of the sensors were conducted to verify the design's performance specifications. A compact data system combining sensor power, signal conditioning, and digitization was assembled for use with the array. Complementing the data system is a robust analysis system capable of near real-time presentation of beamformed and deconvolved contour plots and integrated spectra obtained from array data acquired during flyover passes. Additional instrumentation systems needed to process the array data were also assembled. These include a commercial weather station and a video monitoring / recording system. A detailed mock-up of the instrumentation suite (phased array, weather station, and data processor) was performed in the NASA Langley Acoustic Development Laboratory to vet the system performance. The first deployment of the system occurred at Finnegan Airfield at Fort A.P. Hill where the array was utilized to measure the vehicle noise from a number of sUAS (small Unmanned Aerial System) aircraft. A unique in-situ calibration method for the array microphones using a hovering aerial sound source was attempted for the first time during the deployment.

Humphreys, William M., Jr.↗

Smart Ventilation Controls Boost Energy Efficiency and Indoor Air Quality

The average American household spends more than $2,200 a year on energy, and heating, ventilating, and air conditioning (HVAC) costs comprise nearly half of the bill. This is one reason why home builders focus on tightening building envelopes to save energy. Yet, limiting the potential for air exchange can negatively impact indoor air quality (IAQ). When outdoor conditions are most extreme during occupied periods, there may be comfort implications from continuing high levels of ventilation during associated weather events. This is true even with heat recovery. To mitigate risks, the Florida Solar Energy Center developed and tested approaches for “smart” ventilation system controls that enable more reliable design, installation, and operation to achieve desired IAQ while also minimizing energy and comfort impacts.

Building America↗

Smart Ventilation Controls Boost Energy Efficiency and Indoor Air Quality

The average American household spends more than $2,200 a year on energy, and heating, ventilating, and air conditioning (HVAC) costs comprise nearly half of the bill. This is one reason why home builders focus on tightening building envelopes to save energy. Yet, limiting the potential for air exchange can negatively impact indoor air quality (IAQ). When outdoor conditions are most extreme during occupied periods, there may be comfort implications from continuing high levels of ventilation during associated weather events. This is true even with heat recovery. To mitigate risks, the Florida Solar Energy Center developed and tested approaches for “smart” ventilation system controls that enable more reliable design, installation, and operation to achieve desired IAQ while also minimizing energy and comfort impacts.

30 DIRECT ENERGY CONVERSION↗

Tracer gas test in Net-Zero Energy Residential Test Facility

The Net-Zero Energy Residential Test Facility (NZERTF) at NIST was built in 2012 to support the development and adoption of cost-effective net-zero energy designs, technologies, and construction methods. It is two-story, and has four bedrooms, three bathrooms, and an open living room, dining room, and kitchen space. The NZERTF also has a basement and attic, both located within the conditioned space because the thermal and air-moisture barriers encompass the basement walls and attic roof. Transfer grilles link the living spaces to these two zones. The central heating and cooling system includes an air-toair heat pump, which delivers air to the basement, first and second floors. The heat pump has a cooling capacity of 7.6 kW and a heating capacity of 7.8 kW. The indoor unit is in the basement and ductwork runs along the basement ceiling. A balanced heat recovery ventilator (HRV) is installed in the basement and has its own dedicated ductwork. The HRV supplies 47 L/s of outdoor air to the house, with supplies on the first floor (in the kitchen/dining area) and in each of the three second-floor bedrooms. Air from the first-floor bathroom and both second-floor bathrooms is returned to the HRV before being exhausted, though the HRV was turned off during the tests. The house also has a range hood exhaust and a clothes dryer exhaust, both of which were turned off for the tests. The temperature of the house was measured and the operation of the space conditioning system, including its recirculating air distribution fan, were controlled by a commercially available thermostat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Are low-cost sensors good enough for IAQ controls?

This study used laboratory testing to evaluate low-cost (about $\$ 200$ US) IAQ monitors that measured PM2.5 to determine if they are suitable for controlling IAQ for ventilation or air cleaning systems. Current Indoor Air Quality (IAQ) standards and approaches to minimizing pollutants depend almost exclusively on using dilution with outdoor air for some generic, continuously generated contaminant (e.g., ASHRAE Standard 62.2-2016). Some standards include measurement of CO 2 (e.g., EN 13779 standard (CEN, 2007) and NEN 8088 (NEN, 2011)) – however this is not because CO 2 itself is a pollutant of concern, but rather because it can be used as an occupancy indicator or as something that correlates with bioeffluents. Ideally, we would like to measure contaminant concentrations directly and ventilate to control their concentration within acceptable limits. This would ensure that concentrations do not got too high (as they can if emission rates exceed our assumptions) and also allow for ventilation reductions, and resulting energy savings, if concentrations are low. Until recently, it was impractical to consider direct contaminant control in residential (and many commercial) spaces due to the high cost and maintenance requirements for monitoring equipment. In the past couple of years low-cost sensors have been developed for some contaminants of concern – the greatest example of which is for particles. These sensors have been incorporated into low-cost (<$250 US) IAQ monitors. Finally, this has opened up the possibility of direct control of ventilation (and filtration systems) by sensing particles. However, it is important to evaluate these monitors to determine if their results are sufficiently good to control a ventilation system.

47 OTHER INSTRUMENTATION↗

Numerical and experimental analysis of precooled desiccant system

This paper presents a numerical and experimental study of four novel, desiccant air-conditioning systems based on pre-cooling of the ambient air. The purpose of the study is to: 1) establish which configuration is most profitable for the future studies through numerical and experimental methods; 2) verify the concept of precooled system and confirm that it is working in experimental conditions (for this purpose two prototypes of evaporative cooling units were developed and compared for different operation arrangements with desiccant wheel); 3) Analyze practical aspects of the systems, which includes water consumption analysis, economic analysis and establishing operational modes during a cooling season in temperate climate conditions (the proposed solution has a significant advantage during operation in a temperate climate, since it can utilize its first evaporative cooler the only source of cooling energy when the humidity of outdoor air allows to to meet the latent cooling load). Four arrangements of the system with different dew point evaporative air cooler prototypes were selected and developed for comparative analysis. The system was simulated as a whole, also, each component was individually tested on measurement station. develop the optimal arrangement of the system through numerical and experimental analysis. Four different performance indicators were considered: thermal COP (Coefficient Of Performance), the ERR (Energy Efficiency Ratio), coefficient a describing the potential in compensating indoor cooling loads, water consumption ratio. Also costs of the systems were compared through economic analysis. It was established that arrangement which is characterized by best-averaged performance in terms of all considered factors is a unit combined with two different types of evaporative coolers (marked as System B)- this is caused by the favorable arrangement of two units, where one is better suited to the pre-cooler role, while the other is better suited as the post-cooler.

42 ENGINEERING↗

Research and Development of a Ventilation-Integrated Comfort System

From an indoor air quality perspective, the best residential ventilation strategies include filtering outdoor air and distributing that air to all occupied parts of a home. From an energy standpoint, it is desirable that energy be transferred from the exhaust air to the incoming outdoor air to limit heating and cooling impacts. Heat or energy recovery ventilators (HRVs or ERVs) can provide these functions, but researchers have seen many poor installations related to design, installation, and operation and maintenance. More robust ventilation systems may involve an ERV with a dedicated duct distribution system and controls. Such a duct system can be costly to install, and many builders reduce these costs by connecting an ERV to a central heating and cooling duct system. Although this can sometimes be done effectively, researchers have seen consistent challenges with low, inconsistent, or imbalanced flow rates; high electricity consumption; and—of greatest concern—outdoor air short-circuiting or not being delivered to occupied spaces at all. Most ERVs are designed to operate with their own duct system; they are not designed as an add-on to much larger heating, ventilating, and air-conditioning (HVAC) systems. The ventilation-integrated comfort system (VICS) is expressly designed to integrate with low-capacity, efficient, ducted heating and cooling systems. Overall, the latest VICS prototype consumed 40–75 watts (W), including the air handler power, to deliver 50–120 cfm of whole-dwelling ventilation. The large, cross-flow ERV core performed to match manufacturer values (73% winter sensible effectiveness, 64% summer total effectiveness), but further improvements are possible. The VICS system researched and tested during this project will provide efficient, controllable, balanced energy recovery ventilation that is integrated with heating and cooling systems. The integration reduces space and ductwork needed for separate ventilation systems, and there are no compromises to heating, cooling, or ventilation performance. The integrated nature of the device also reduces risks for improper installation and commissioning. Even when using the air handler blower to distribute outdoor air, the total power consumption is lower than that of most available ERV products in the same airflow range. This system has the potential to offer very high-performance ventilation with much smoother and simpler installation than conventional systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

PV module spectral response measurements - Data and Resources

"This dataset includes spectral response curves for 12 commercial silicon module types that are deployed at SNL in Albuquerque. The modules chosen for evaluation were originally purchased by SNL for the PV Lifetime project (renamed to Systems Long-Term Evaluation [SLTE]). The majority of those modules are deployed outdoors for long-term evaluation, but several modules of each type were placed in storage for future comparison purposes. One stored module of each type was sent to NREL for the spectral response measurements. NREL used the recently developed Module Quantum Efficiency (QE) test bed. What makes this system unique is that it scans the entire module automatically, taking one or more measurements on each cell. Using the mean of these measurements at each wavelength leads to improvements in spectral mismatch correction and module power measurements but having the individual measurements also makes it possible to identify outlier cells, which could be useful for investigating underperforming modules. All measurements were performed nominally at 25°C"

14 SOLAR ENERGY↗

Acoustic facilities for human factors research at NASA Langley Research Center: Description and operational capabilities

A number of facilities were developed which provide a unique test capability for psychoacoustics and related human factors research. The design philosophy, physical layouts, dimensions, construction features, operating capabilities, and example applications for these facilities are described. In the exterior effects room, human subjects are exposed to the types of noises that are experienced outdoors, and in the interior effects room, subjects are exposed to the types of noises and noise-induced vibrations that are experience indoors. Subjects are also exposed to noises in an echo-free environment in the anechoic listening room. An aircraft noise synthesis system, which simulates aircraft flyover noise at an observer position on the ground, is used in conjunction with these three rooms. The passenger ride quality apparatus, a device for studying passenger response to noise and vibration in aircraft, or in other vehicles, is described.

Hubbard, H. H.↗

Glass/glass photovoltaic module reliability and degradation: a review

Glass/glass (G/G) photovoltaic (PV) module construction is quickly rising in popularity due to increased demand for bifacial PV modules, with additional applications for thin-film and building-integrated PV technologies. G/G modules are expected to withstand harsh environmental conditions and extend the installed module lifespan to greater than 30 years compared to conventional glass/backsheet (G/B) modules. With the rapid growth of G/G deployment, understanding the outdoor performance, degradation, and reliability of this PV module construction becomes highly valuable. In this review, we present the history of G/G modules that have existed in the field for the past 20 years, their subsequent reliability issues under different climates, and methods for accelerated testing and characterization of both cells and packaging materials. We highlight some general trends of G/G modules, such as greater degradation when using poly(ethylene-co-vinyl acetate) (EVA) encapsulants, causing the industry to move toward polyolefin-based encapsulants. Transparent backsheets have also been introduced as an alternative to the rear glass for decreasing the module weight and aiding the effusion of trapped gaseous degradation products in the laminate. New amendments to IEC 61215 standard protocols for G/G bifacial modules have also been proposed so that the rear side power generation and UV exposure will be standardized. We further summarize a suite of destructive and non-destructive characterization techniques, such as current-voltage scans, module electro-optical imaging, adhesion tests, nanoscale structural/chemical investigation, and forensic analysis, to provide deeper insights into the fundamental properties of the module materials degradation and how it can be monitored in the G/G construction. This will set the groundwork for future research and product development.

14 SOLAR ENERGY↗

Glass/Glass Photovoltaic Module Reliability and Degradation: A Review - Figures

Glass/glass (G/G) photovoltaic (PV) module construction is quickly rising in popularity due to increased demand for bifacial PV modules, with additional applications for thin-film and building-integrated PV technologies. G/G modules are expected to withstand harsh environmental conditions and extend the installed module lifespan to greater than 30 years compared to conventional glass/backsheet (G/B) modules. With the rapid growth of G/G deployment, understanding the outdoor performance, degradation, and reliability of this PV module construction becomes highly valuable. In this review, we present the history of G/G modules that have existed in the field for the past 20 years, their subsequent reliability issues under different climates, and methods for accelerated testing and characterization of both cells and packaging materials. We highlight some general trends of G/G modules, such as greater degradation when using poly(ethylene-co-vinyl acetate) (EVA) encapsulants, causing the industry to move toward polyolefin-based encapsulants. Transparent backsheets have also been introduced as an alternative to the rear glass for decreasing the module weight and aiding the effusion of trapped gaseous degradation products in the laminate. New amendments to IEC 61215 standard protocols for G/G bifacial modules have also been proposed so that the rear side power generation and UV exposure will be standardized. We further summarize a suite of destructive and non-destructive characterization techniques, such as current-voltage scans, module electro-optical imaging, adhesion tests, nanoscale structural/chemical investigation, and forensic analysis, to provide deeper insights into the fundamental properties of the module materials degradation and how it can be monitored in the G/G construction. This will set the groundwork for future research and product development.

transparent backsheet↗

Outdoor annual algae productivity improvements at the pre-pilot scale through crop rotation and pond operational management strategies

The Development of Integrated Screening, Cultivar Optimization, and Verification Research (DISCOVR) collaborative consortium operated pre-pilot scale outdoor ponds to deliver much-needed multi-year, long-term and consistent, algae cultivation data relevant to understanding the current state of technology in terms of expected seasonal algae biomass productivity. Over the course of four years from 2018 to 2021, twelve identical 4.2 m 2 mini-ponds were run in triplicate sets to test strains and operational strategies demonstrated in small-, indoor photobioreactors, in pursuit of increasing overall algae areal productivity and projected farm yield. Fourteen different cultivars derived from a strain screening pipeline were tested. Through deliberate seasonal crop rotation and improvements in operational strategies, annual biomass productivity increased from 11.6 to 17.6 g m -2 day -1 , a > 50% increase over the 2018 baseline. Both brackish and marine strains were included and four out of the fourteen strains consistently yielded high productivity across multiple years; brackish strains Monoraphidium minutum (26BAM) and Scenedesmus obliquus (UTEX393), and marine strains Tetraselmis striata (LANL1001) and Picochlorum celeri (TG2). These freely available datasets, which represent nearly complete annual daily coverage of cultivation metrics including weather, pond temperature and pH, nutrients, and productivity, are unique in the public domain and seek to fill agronomic and operational knowledge gaps to help in the eventual commercialization of algal biofuels and bioproducts.

09 BIOMASS FUELS↗

Outdoor Home Gardener Preferences for Environmental Attributes in Gardening Supplies and Use of Ecofriendly Gardening Practices

Home gardeners’ concerns for the environment are expressed both in the ecofriendly gardening practices they use and in environmental attributes they prefer in the gardening products they purchase. This study uses data from a 2018 survey of 601 Tennessee outdoor home gardeners and a multiple indicators multiple causes (MIMIC) model to illustrate how outdoor home gardener demographics, expenditures, information use, and attitudes influence use of ecofriendly gardening practices and preferences for environmental attributes in home gardening supplies. Practices considered include planting pollinator plants, using rainwater collectors, composting, recycling gardening supplies packaging, using organic gardening methods, and use of soil testing. Gardening supply product attributes include decreased need for fertilizer, pesticides, and water; native plant species; organically produced products; and recyclable packaging. The most widely used practice is recycling gardening supplies packaging, and the least used is soil testing. Gardeners with a greater propensity to use the six gardening practices include male, college graduates, who spend relatively more of their income on gardening supplies, and consider themselves as being knowledgeable about environmental issues. The gardening supply product attribute most widely considered as important is decreased need for pesticides, and least widely considered as important are native species and organically produced. Gardeners more likely to prefer the six gardening supply product attributes include older gardeners, who seek other gardeners for information, and who perceived themselves as being knowledgeable about the environment. This same group likes to grow their own food and feels responsibility for protecting the environment for future generations.

54 ENVIRONMENTAL SCIENCES↗

Advanced Perovskite Solar Cells and Modules

The “Advanced perovskite Cells and Modules” research project was the final agreement focused on enhancing perovskite solar cell (PSC) technologies funded by the US Department of Energy's Solar Energy Technologies Office. The project was designed to address three crucial areas in PSC development: stability, manufacturability, and efficiency. The project was then structured around three main tasks, each targeting one of these strategic goals. The team of experienced researchers in these materials worked collaboratively to address the targets outlined in the technical work plan. building on existing PSC research while also exploring promising new concepts arising in the field. An overview of each primary task is summarized below: Task 1 Stability: This first task, aims to identify material characteristics and metrics that can help predict the primary degradation mechanisms impacting PSC stability. This involved developing specific device tests based on hypotheses regarding mechanisms impacting stability, including fast failure procedures to speed up PSC development and improvement. Various strategies to enhance stability, like incorporating additives, post-treatments, novel contact materials etc. were developed using this fast feedback approach. The relationships between indoor and outdoor stresses were also validated. Task 2 Manufacturability: This second task, focused on creating a scalable production process for PSCs. Initially the objective is to establish a best-known method for a 182 cm2 minimodule. However, given resource limitations, these metrics were modified to focus on the other goal of outlined in the TWP. Specifically, this task worked to demonstrate the transferability of this best-known method to another research institution. Work scope in this area was expanded to material purity and understanding of reagent/process relationships. Examination of other difficulties in PSC production and potential solutions for large-scale production were also evaluated. Given challenges observed in process transfer, work to develop data infrastructure and recording tools for processing of material and devices was then also prioritized in this task. Task 3 Efficiency: This task was focused on improvements to PCE, while still considering Task 1 and Task 2 goal. The efforts targeted a PCE greater than 22% with a T95 exceeding 1000 hours at 25°C in a nitrogen environment for lab-scale devices (approximately 0.1 cm2 devices) across a range of solar-relevant perovskite compositions, including wide-gap (around 1.7 eV) and low-gap (around 1.3 eV) materials, using standard metal contacts. This work then provides a foundation for MHP-based tandem efforts undertaken in other projects and the All-MHP tandem efforts outlined in this projects TWP. Work in this project emphasized disseminating its findings through peer-reviewed publications (PRP), conference presentations, and industrial collaborations. Significant products were produced in all these areas, over 53 peer reviewed publications, 32 conference presentations and industrial investment based on NLR assistance on precompetitive challenges. The team also developed significant intellectual property and awards for their technical excellence, innovations and leadership. The team also leveraged traditional and social media platforms to engage with stakeholders and the public.

14 SOLAR ENERGY↗

Algal Biomass Conversion to Fuels via Combined Algae Processing (CAP): 2022 State of Technology and Future Research

The annual State of Technology (SOT) assessment is an essential activity for platform research conducted under the Bioenergy Technologies Office (BETO). It allows for the impact of research progress (both directly achieved in-house at NREL and furnished by partner organizations) to be quantified in terms of economic improvements in the overall biofuel production process for a particular biomass processing pathway, whether based on terrestrial or algal biomass feedstocks. As such, initial benchmarks can be established for currently demonstrated performance, and progress can be tracked toward out-year goals to ultimately demonstrate economically viable biofuel technologies. NREL's algae SOT benchmarking efforts focus both on front-end algal biomass production and separately on back-end conversion to fuels through NREL's "combined algae processing" (CAP) pathway. The production model is based on outdoor long-term cultivation data, enabled by comprehensive algal biomass production trials conducted under Development of Integrated Screening, Cultivar Optimization, and Verification Research (DISCOVR) consortium efforts and driven by data furnished by Arizona State University's (ASU's) Arizona Center for Algae Technology and Innovation (AzCATI) test bed site. The CAP model is primarily based on experimental efforts conducted under NREL research and development projects, with some process parameters provided by partner organizations. Assumptions regarding the wet storage of algae use data provided by Idaho National Laboratory (INL), while parts of the polyurethane production process leverage BETO-funded research from collaborators at Algenesis and the University of California, San Diego (UCSD). This report focuses on back-end conversion of algal biomass through the CAP pathway, highlighting the 2022 updates to minimum fuel selling price (MFSP). This update incorporates improvements to fermentation performance for two biological pathways through carboxylic acid and 2,3-butanediol (BDO) intermediates, as demonstrated through parallel research on the biochemical conversion of corn stover. Improvements are applied to the glucose fraction of the biomass only, while parameters regarding the conversion of the mannose fraction (not a significant component in corn stover) are maintained consistently with prior CAP SOTs. Additional parameters are also updated to reflect the most current understanding of each pathway, including an increase in the catalyst loading requirement in the ketonization step of the acids pathway and a decrease in the fermentation productivity in the BDO pathway. Additionally, the biomass feedstock costs (minimum biomass selling price [MBSP]), yields, and seasonal variability from the upstream cultivation SOT model were also incorporated into downstream Aspen Plus CAP models.

09 BIOMASS FUELS↗

Influence of alkali-silica reaction on the shear capacity of reinforced concrete beams with minimum transverse reinforcement

A growing number of critical concrete infrastructure are affected by alkali-silica reaction (ASR) damage such as the Seabrook Nuclear Power Plant in New Hampshire, Parker arch-gravity dam in Arizona, and several highway bridges in California and Texas. ASR causes expansion and cracking and degrades the concrete mechanical properties. Despite a wealth of material level studies there is still limited large-scale experimental data regarding the effects of ASR on reinforced concrete (RC) members. Due to the brittle nature of the shear failure in RC structures, this study focuses on the shear response of full-scale ASR damaged RC beams with minimum shear reinforcement. Six RC beams were built with different levels of ASR susceptibility and conditioned in different environments during which continuous expansion monitoring was performed. The beams all contained reactive fine aggregate (sand) and two of them had additional alkali, 1.25% by weight of cement, to accelerate ASR. The highest expansion rate of the beams happened during the first 150 days and the expansions stayed constant after 240 days and 330 days for beams conditioned in outdoor and laboratory conditions, respectively, until the last measurement at 575 days. The highest expansion, 0.4%, was seen in the beams with additional alkali and conditioned outside with regular water spray. Out of the six beams, three were selected at different levels of ASR damage and two shear tests were performed on the minimally reinforced spans close to the ends of each beam. Results indicated that beams gain shear strength from ongoing cement hydration in the presence of moisture for ASR expansions less than 0.2%. Compared to one of the beams with 0.2% ASR expansion, one of the other samples with 0.4% expansion lost 6% of its shear strength, 25% of its shear stiffness, and showed about two times larger shear cracks and shear deformations at peak load. Finally, the shear reinforcement yielded at 20% less load in the beam with 0.4% expansion compared to the beam with 0.2% expansion.

42 ENGINEERING↗