Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical losses”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Field retrieved photovoltaic backsheet survey from diverse climate zones: Analysis of degradation patterns and phenomena

Understanding the impact of climate stressors on photovoltaic (PV) backsheet degradation in real-use conditions is critical to improve the accelerated testing exposures, extend the backsheet lifetime, and increase the confidence in PV reliability. Here, in this work, a total of 33 PV module backsheets were retrieved from six climatic zones worldwide with 2 - 28 years of exposure. These modules included five types of backsheet air-side materials (or outer layer): poly(vinylidene fluoride) (PVDF), poly(tetrafluoroethylene-co-hexafluoropropylene-co-vinylidene fluoride) (THV), poly(vinyl fluoride) (PVF), poly(ethylene terephthalate) (PET), and polyamide (PA). Attenuated total reflection Fourier-transform infrared spectroscopy (ATR-FTIR) was used to identify air-side materials. The degradation induced color change, gloss loss, and chemical material changes analyzed using optical microscopy, differential scanning calorimetry (DSC), scanning electron microscopy (SEM), colorimetry (yellowness index (YI)), and gloss measurements. PVDF, THV, and PVF air-side layer backsheets, in particular PVF, had minimal degradation in the air-side layer appearance and chemical structures after exposure in different climatic zones. The PET air-side backsheets exhibited obvious color increase (22.55 YI units after about 9 years exposure) and the PA/PA/PA backsheets showed large gloss loss (up to 76.4 %) relative to the unexposed backsheets. Severe cracks between cells that penetrated through the entire thickness of backsheets are observed on PA/PA/PA backsheets after 4-6 years of exposure in 6 climatic zones. The current indoor exposure standards were not sufficient to identify this degradation type. However, fluoropolymer based PV backsheets showed lower levels of degradation predictors and increased climatic resistance. Specific samples (PVF) showed little change from baseline after 28 years of outdoor exposure.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Decomposition of the photoabsorption Schumann-Runge continuum in O2

The photoabsorption Schumann-Runge continuum in O2 has been decomposed into the contribution from states of both valence and Rydberg character. The decomposition of the experimental photoabsorption (or high-energy, zero-angle, electron energy-loss) data contains contributions from three valence states, four Rydberg states, and one state of unknown character. Information on the perturbed valence-state potential-energy curves in the Franck-Condon region obtained by this analysis substantiate the recent theoretical conclusions of strong valence-Rydberg perturbations in the 8-12 eV excitation region. There is presently no unambiguous identification for the state at 8.93 plus or minus 0.04 eV, found in the optical and all the electron energy-loss data.

Cartwright, D. C.↗

Oriented Scintillation Spectrometer Experiment observations of Co-57 in SN 1987A

The Oriented Scintillation Spectrometer Experiment (OSSE) on the Compton Gamma Ray Observatory has observed SN 1987A for two 2 week periods during the first 9 months of the mission. Evidence for gamma-ray line and continuum emission from Co-57 is observed with an intensity of about 10 exp -4 gamma/sq cm/s. This photon flux between 50 and 136 keV is demonstrated by Monte Carlo calculations to be independent of the radial distribution of Co-57 for models of low optical depth, viz., models having photoelectric absorption losses of 122 keV photons no greater than several percent. For such models the observed Co-57 flux indicates that the ratio Ni-57/Ni-56 produced in the explosion was about 1.5 times the solar system ratio of Fe-57/Fe-56. When compared with nearly contemporaneous bolometric estimates of the luminosity for SN 1987A, our observations imply that Co-57 radioactivity does not account for most of the current luminosity of the supernova remnant in low optical depth models. We suggest alternatives, including a large optical depth model that is able to provide the SN 1987A luminosity and is consistent with the OSSE flux. It requires a 57/56 production ratio about twice solar.

Kurfess, J. D.↗

Excited state absorption of pump radiation as a loss mechanism in solid-state lasers

The characteristics of optical pumping dynamics in laser-pumped, rare-earth-doped, solid-state laser materials are investigated by using a tunable alexandrite laser to pump Y3Al5O12:Nd(3+) in an optical cavity. It is found that the slope efficiency of the Nd laser operation depends strongly on the wavelength of the pump laser. For pump wavelengths resulting in low slope efficiencies, intense fluorescence emission is observed from the sample in the blue-green spectral region. This is attributed to the excited-state absorption of pump photons which occurs during radiationless relaxation from the pump band to the metastable state. This type of process is an important loss mechanism for monochromatic pumping of laser systems at specific pump wavelengths.

Kliewer, Michael L.↗

A Study of an Optical Lunar Surface Communications Network with High Bandwidth Direct to Earth Link

A lunar surface systems study explores the application of optical communications to support a high bandwidth data link from a lunar relay satellite and from fixed lunar assets. The results show that existing 1-m ground stations could provide more than 99% coverage of the lunar terminal at 100Mb/s data rates from a lunar relay satellite and in excess of 200Mb/s from a fixed terminal on the lunar surface. We have looked at the effects of the lunar regolith and its removal on optical samples. Our results indicate that under repeated dust removal episodes sapphire rather than fused silica would be a more durable material for optical surfaces. Disruption tolerant network protocols can minimize the data loss due to link dropouts. We report on the preliminary results of the DTN protocol implemented over the optical carrier.

lunar optical communications↗

NASA Glenn/AADC-Rolls Royce Collaborated to Measure Erosion Resistance on Coated Polymer Matrix Composites

Polymer matrix composites (PMCs) are increasingly used in aerospace and automotive applications because of their light weight and high strength-to-weight ratio relative to metals. However, a major drawback of PMCs is poor abrasion resistance, which restricts their use, especially at high temperatures. Simply applying a hard coating on PMCs to improve abrasion and erosion resistance is not effective since coating durability is short lived (ref. 1). Generally, PMCs have higher coefficients of thermal expansion than metallic or ceramic coatings have, and coating adhesion suffers because of poor interfacial adhesion strength. One technique commonly used to improve coating adhesion or durability is the use of bond coats that are interleaved between a coating and a substrate with vastly different coefficients of thermal expansion. An example of this remedy is the use of bondcoats for ceramic thermal barrier coatings on metallic turbine components (ref. 2). Prior collaborative research between the NASA Glenn Research Center and the Allison Advanced Development Company (AADC) demonstrated that bond coats sandwiched between PMCs and high-quality plasma-sprayed, erosion-resistant coatings substantially improved the erosion resistance of PMCs (ref. 3). One unresolved problem in this earlier collaboration was that there was no easy, accurate way to measure the coating erosion wear scar. Coating wear was determined by both profilometry and optical microscopy. Both techniques are time consuming. Wear measurement by optical microscopy requires sample destruction and does not provide a comprehensive measure of the entire wear volume. An even more subtle, yet critical, problem is that these erosion coatings contain two or more materials with different densities. Therefore, simply measuring specimen mass loss before and after erosion will not provide an accurate gauge for coating and/or substrate volume loss. By using a noncontact technique called scanning optical interferometry, which was recently developed at Glenn, researchers can accurately determine the wear performance of erosion-coated PMCs while preserving the sample. An example of this interferometry technique is shown in the preceding figure for an erosion-coated inlet guide vane from a Rolls Royce AE3007 regional gas turbine jet engine. Erosion was conducted with coated and uncoated PMC vanes, with the abrasive material moving at a velocity of 229 m/s at impingement angles of 20 and 90 degrees. The coatings for PMCs remarkably reduced the erosion volume loss by a factor of approximately 10. Currently, several erosion coatings for PMCs are being compared and downselected for engine testing at Rolls Royce.

Miyoshi, Kazuhisa↗

Electron-impact excitation of UF6 at an electron energy of 20 eV in the energy-loss range of 0-10 eV

A technique combining electron impact excitation and optical absorption spectroscopy was applied to UF6. The crucial features of the experiment were that: (1) the electron optics was differentially pumped relative to the scattering chamber and (2) the target UF6 beam was condensed on a liquid nitrogen cold trap placed immediately above the scattering center. Energy loss spectra are presented at an incident electron energy of 20 eV and at scattering angles between 20 and 135 degrees. It is shown that no transitions are found below the first-detected feature at 3.0 eV and an optically forbidden excitation is found at 4.2 eV. A fairly strong optical absorption at 4.8 eV is observed to 'fill-in' at a scattering angle of 20 degrees but is practically absent at higher angles.

Chutjian, A.↗

Hubble Space Telescope: Faint object spectrograph instrument handbook. Version 1.1

The Faint Object Spectrograph (FOS) has undergone substantial rework since the 1985 FOS Instrument Handbook was published, and we are now more knowledgeable regarding the spacecraft and instrument operations requirements and constraints. The formal system for observation specification has also evolved considerably, as the GTO programs were defined in detail. This supplement to the FOS Instrument Handbook addresses the important aspects of these changes, to facilitate proper selection and specification of FOS observing programs. Since the Handbook was published, the FOS red detector has been replaced twice, first with the best available spare in 1985 (which proved to have a poor, and steadily degrading red response), and later with a newly developed Digicon, which exhibits a high, stable efficiency and a dark-count rate less than half that of its predecessors. Also, the FOS optical train was realigned in 1987-88 to eliminate considerable beam-vignetting losses, and the collimators were both removed and recoated for greater reflectivity. Following the optics and detector rework, the FOS was carefully recalibrated (although only ambient measurements were possible, so the far-UV characteristics could not be re-evaluated directly). The resulting efficiency curves, including improved estimates of the telescope throughput, are shown. A number of changes in the observing-mode specifications and addition of several optional parameters resulted as the Proposal Instructions were honed during the last year. Target-brightness limitations, which have only recently been formulated carefully, are described. Although these restrictions are very conservative, it is imperative that the detector safety be guarded closely, especially during the initial stages of flight operations. Restrictions on the use of the internal calibration lamps and aperture-illumination sources (TA LEDs), also resulting from detector safety considerations, are outlined. Finally, many changes have been made to the instructions for target acquisition specification.

Ford, Holland C.↗

A high-performance single-mode fiber-optic isolator assembly

A high-isolation single-mode fiber optic isolator assembly was designed and fabricated. The measured forward loss is 2.6 dB and the reverse loss (isolation) is greater than 70 dB. This is a 30-dB higher isolation than the isolation of the best fiber optic isolator previously reported. This isolator provides isolation between the semiconductor laser diode and the optical fiber in a precise reference frequency transmission system. The isolation of the laser greatly reduces the system's sensitivity to microphonics.

Lutes, G.↗

Millikelvin measurements of permittivity and loss tangent of lithium niobate

Lithium niobate is an electro-optic material with many applications in microwave and optical signal processing, communication, quantum sensing, and quantum computing. In this Letter, we present findings on evaluating the complex electromagnetic permittivity of lithium niobate at millikelvin temperatures. Measurements are carried out using a resonant-type method with a superconducting radio-frequency cavity operating at 7 GHz and designed to characterize anisotropic dielectrics. The relative permittivity tensor and loss tangent are measured at 50 mK with unprecedented accuracy.

36 MATERIALS SCIENCE↗

Fabrication Development for SPT-SLIM, a Superconducting Spectrometer for Line Intensity Mapping

Line Intensity Mapping (LIM) is a new observational technique that uses low-resolution observations of line emission to efficiently trace the large-scale structure of the Universe out to high redshift. Common mm/sub-mm emission lines are accessible from ground-based observatories, and the requirements on the detectors for LIM at mm-wavelengths are well matched to the capabilities of large-format arrays of superconducting sensors. We describe the development of an R = lambda/Delta lambda = 300 on-chip superconducting filter-bank spectrometer covering the 120-180 GHz band for future mm-LIM experiments, focusing on SPT-SLIM, a pathfinder LIM instrument for the South Pole Telescope. Radiation is coupled from the telescope optical system to the spectrometer chip via an array of feedhorn-coupled orthomode transducers. Superconducting microstrip transmission lines then carry the signal to an array of channelizing half-wavelength resonators, and the output of each spectral channel is sensed by a lumped element kinetic inductance detector (leKID). Key areas of development include incorporating new low-loss dielectrics to improve both the achievable spectral resolution and optical efficiency and development of a robust fabrication process to create a galvanic connection between ultra-pure superconducting thin-films to realize multi-material (hybrid) leKIDs. We provide an overview of the spectrometer design, fabrication process, and prototype devices.

microstrip resonators↗

Single-Objective Airy Light-Sheet Imaging

Despite its massive potential, standard light-sheet imaging (LSI) faces key challenges, such as the incompatibility with common sample mounting techniques and low-resolution imaging. Single-objective LSI attempts to address these issues but often suffers from limited fields-of-view and throughput rates, or requires multiple optics that increase costs, alignment complexity, and losses. To overcome these challenges of standard single-objective LSI, we introduce single-objective Airy light-sheet imaging (SoALSI). SoALSI leverages the extraordinary self-acceleration properties of the Airy beam, achieving 5× higher imaging rates and enhanced imaging efficiency than standard single-objective LSI. Here, we demonstrate SoALSI’s versatility through rigorous contrast and resolution characterizations and by high-resolution imaging of diverse biological specimens, including malaria parasite-infected red blood cells and plant root tissue. SoALSI seamlessly integrates with any standard inverted microscope frame, enabling broader accessibility for the bioimaging community to explore biological processes in a wide range of specimens with enhanced resolution and imaging contrast.

airy beam↗

Optimizing Lunar Map Partitioning for Multipath Fade Loss Analyses

A methodology is presented pertaining to the run-time optimization of quasi-optical ray-tracing simulations. These shooting-and-bouncing ray methods are used for assessing multipath fade loss in cislunar communication links. Our approach employs partitioning lunar terrain maps in shapes that approximate two-dimensional projections of Fresnel zone cross-sections. This technique drastically reduces computational run-time without causing significant loss of simulation accuracy.

Digital elevation models↗

CMOS-fabricated ultraviolet light modulator using low-loss alumina piezo-optomechanical photonics

Ultra-violet (UV) and near-UV wavelengths are necessary for many important optical transitions for quantum technologies and various sensing mechanisms for biological and chemical detection. However, all well-known photonic platforms have excessively high losses in the UV, which has prevented photonic integrated circuits (PICs) being used to address these and other important application spaces. Photonic waveguides using low-loss alumina cores and silicon dioxide cladding have emerged as a promising solution because of alumina’s large optical bandgap and the high quality of films enabled by atomic layer deposition. These properties allow passive, low-loss waveguide operation down to at least 266 nm using multimode widths. However, to the best of our knowledge, active alumina PICs have only been realized using thermo-optic tuning, which precludes switching speeds shorter than approximately 100 microseconds, high circuit densities, and cryogenically compatible operation. Here, we introduce a CMOS-fabricated, piezo-optomechanical PIC platform using alumina waveguides and piezoelectric aluminum nitride strain actuators. The platform allows for sub-microsecond switching times, high circuit densities, and cryogenic operation which is desired in many UV PIC applications. We demonstrate a high-performance, reconfigurable optical filter operating at wavelengths as low as 320 nm. The filter has a 6-nanosecond switching time, a loaded linewidth of 3.3 GHz, tuning rate of 28 V/linewidth, and a hold power of less than 20 nW at one linewidth detuning. This work establishes the foundations for a new class of CMOS-fabricated, rapidly reconfigurable, and low-power UV photonic circuits compatible with wavelengths as low as 225 nm.

Castillo, Zachary A. [Sandia National Laboratories↗

Noncontact measurement of high temperature using optical fiber sensors

The primary goal of this research program was the investigation and application of noncontact temperature measurement techniques using optical techniques and optical fiber methods. In particular, a pyrometer utilizing an infrared optical light pipe and a multiwavelength filtering approach was designed, revised, and tested. This work was motivated by the need to measure the temperatures of small metallic pellets (approximately 3 mm diameter) in free fall at the Microgravity Materials Processing Drop Tube at NASA Marshall Space Flight Center. In addition, research under this program investigated the adaptation of holography technology to optical fiber sensors, and also examined the use of rare-earth dopants in optical fibers for use in measuring temperature. The pyrometer development effort involved both theoretical analysis and experimental tests. For the analysis, a mathematical model based on radiative transfer principles was derived. Key parameter values representative of the drop tube system, such as particle size, tube diameter and length, and particle temperature, were used to determine an estimate of the radiant flux that will be incident on the face of an optical fiber or light pipe used to collect radiation from the incandescent falling particle. An extension of this work examined the advantage of inclining or tilting the collecting fiber to increase the time that the falling particle remains in the fiber field-of-view. Those results indicate that increases in total power collected of about 15 percent may be realized by tilting the fiber. In order to determine the suitability of alternative light pipes and optical fibers, and experimental set-up for measuring the transmittance and insertion loss of infrared fibers considered for use in the pyrometer was assembled. A zirconium fluoride optical fiber and several bundles of hollow core fiber of varying diameters were tested. A prototype two-color pyrometer was assembled and tested at Virginia Tech, and then tested on the Drop Tube at Marshall Space Flight Center. Radiation from 5 mm diameter niobium drops falling in the Drop Tube was successfully detected, and recorded for later analysis. Subsequent analysis indicated that the imaging of light output from the light pipe onto the detector active areas was not identical for both detectors.

Claus, R. O.↗

Characterizing non-polarization-maintaining highly nonlinear fiber toward squeezed-light generation

Squeezed light, which is easily degraded by loss, could benefit from generation directly in optical fiber. Furthermore, highly nonlinear fiber could offer more efficient generation with lower pump power and shorter fiber lengths than standard single-mode fiber. We investigate non-polarization-maintaining highly nonlinear fiber (HNLF) for squeezed-light generation by characterizing possible sources of excess noise, including its zero-dispersion wavelength (ZDW) variation and polarization noise. We find significant ZDW variation and excess polarization noise. We believe the polarization noise is from non-linear polarization-mode dispersion. We model this polarization noise and find that it is likely to degrade Kerr squeezing but not squeezing from four-wave mixing.

47 OTHER INSTRUMENTATION↗

Development of a colinear Second-Harmonic Orthogonal Polarization (SHOP) interferometer for electron areal density measurements in Magnetically Insulated Transmission Lines (MITLs)

Experimental measurements of low density plasmas forming in Magnetically Insulated Transmission Line (MITL) regions are desired to improve our understanding of current loss and power flow. Therefore, a new optical interferometer diagnostic was commissioned via this LDRD project. To measure the expected 10 13 - 10 17 cm -3 electron densities inside the 0.5 - 6 mm Anode-Cathode (A-K) gaps, a colinear SHOP interferometer diagnostic was constructed. The diagnostic was initially fielded on the University of New Mexico (UNM) Helicon-Cathode (HelCat) plasma device which provided a highly repeatable and well understood plasma source for which the colinear SHOP interferometer’s functionality could be verified and measured. Utilizing the highly repeatable plasma source and shot averaging, the interferometer was able to achieve an areal density sensitivity of 1×10 14 cm -2 . This work at UNM lead to a Review of Scientific Instruments (RSI) publication [20], DOI:10.1063/5.0101687. After the diagnostic’s capability was proven at UNM, the colinear SHOP interferometer was commissioned for use on the Sandia National Laboratories (SNL) Mykonos accelerator. Here, it provided the first temporal areal density measurements of plasma formation in a parallel plate MITL. The diagnostic was able to achieve a single shot (no multi-shot averaging like at UNM) areal density sensitivity of 1×10 15 cm -2 along a ~ 2mm probing path length, which provided adequate capability to conduct fundamental physics research of MITL plasma formation. CHICAGO and ALEGRA simulations support the diagnostics experimental findings. More experimental and computational work will continue, likely leading to another publication(s). The smaller scale Mykonos accelerator work has also provided justification that the colinear SHOP interferometer is a capable diagnostic for measuring plasma areal densities in the inner MITL and convolute regions of larger TW-class accelerators like SNL’s Z machine.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

JWST Noise Floor. II. Systematic Error Sources in JWST NIRCam Time Series

The James Webb Space Telescope (JWST) holds great promise for characterizing atmospheres of transiting exoplanets, potentially providing insights into Earth-sized planets within the habitable zones of M-dwarf host stars if photon-limited performance can be achieved. Here, we discuss the systematic error sources that are expected to be present in grism time-series observations with the NIRCam instrument. We find that pointing jitter and high-gain antenna moves in addition to the detectors’ subpixel crosshatch patterns will produce relatively small variations (less than 6 parts per million, ppm). The time-dependent aperture losses due to thermal instabilities in the optics can also be kept to below 2 ppm. To achieve these low noise values, it is important to employ a sufficiently large (more than 11) extraction aperture. Persistence due to charge-trapping will have a minor (less than 3 ppm) effect on the time series 20 minutes into an exposure and is expected to play a much smaller role than it does for the Hubble Space Telescope WFC3 detectors. We expect detector temperature fluctuations to contribute less than 3 ppm. In total, our estimated noise floor from known systematic error sources is only 9 ppm per visit. We urge caution, however, because unknown systematic error sources could be present in flight and will only be measurable on astrophysical sources such as quiescent stars. We find that reciprocity failure may introduce a perennial instrument offset at the 40 ppm level, so corrections may be needed when a multi-instrument multi-observatory spectrum is stitched together over wide wavelength ranges.

47 OTHER INSTRUMENTATION↗