Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical interferometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Tests of a full-scale ITER toroidal interferometer and polarimeter (TIP) prototype on the DIII-D tokamak (invited)

A full-scale ITER toroidal interferometer and polarimeter (TIP) prototype, including an active feedback alignment system, has been installed and tested on the DIII-D tokamak. In the TIP prototype, a two-color interferometry measurement of line-integrated density is carried out at 10.59 μm and 5.22 μm using a CO 2 and quantum cascade laser, respectively, while a separate polarimetry measurement of the plasma-induced Faraday effect is made at 10.59 μm. The TIP prototype is equipped with a piezo tip/tilt stage active feedback alignment system that minimizes noise in the measurement and keeps the diagnostic aligned throughout DIII-D discharges. The measured phase resolution for the polarimeter and interferometer is 0.05° (100 Hz bandwidth) and 1.9° (1 kHz bandwidth), respectively. Here, the corresponding line-integrated density resolution for the vibration-compensated interferometer is δnL = 1.5 × 10 18 m -2 , and the magnetic field-weighted line-integrated density from the polarimeter is δnBL = 1.5 × 10 19 Tm -2 . Both interferometer and polarimeter measurements during DIII-D discharges compare well with the expectations based on calculations using Thomson scattering measured density profiles and magnetic equilibrium reconstructions. Additionally, larger bandwidth interferometer measurements show that the diagnostic is a sensitive monitor of core density fluctuations with demonstrated measurements of Alfvén eigenmodes and tearing modes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental investigation of the compression and heating of an MHD-driven jet impacting a target cloud

Herein adiabatic compression has been investigated by having an MHD-driven plasma jet impact a gas target cloud. Compression and heating of the jet upon impact were observed and compared to theoretical predictions. Diagnostics for comprehensive measurements included a Thomson scattering system, a fast movie camera, a translatable fiber-coupled interferometer, a monochromator, a visible-light photodiode, and a magnetic probe array. Measurements using these diagnostics provided the time-dependent electron density, electron temperature, continuum emission, line emission, and magnetic field profile. Increases in density and magnetic field and a decrease in jet velocity were observed during the compression. The electron temperature had a complicated time dependence, increasing at first, but then rapidly declining in less than 1 μs which is less than the total compression time. Analysis indicates that this sudden temperature drop is a consequence of radiative loss from hydrogen atoms spontaneously generated via three-body recombination in the high-density compressed plasma. A criterion for how fast compression must be to outrun radiative loss is discussed not only for the Caltech experiment but also for fusion-grade regimes. In addition, the results are analyzed in the context of shocks the effects of which are compared to adiabatic compression.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of wire-array Z-pinches by laser probing diagnostics

Laser diagnostics provides powerful tools for the investigation of dense Z-pinches. In this paper, wire-array Z-pinches are investigated at the 1 MA Zebra generator using laser diagnostics at different wavelengths coupled with x-ray diagnostics. Plasma dynamics during the ablation, implosion, and stagnation stages are observed by multiframe diagnostics. Cascading and nonprecursor implosions are studied in wire arrays. Ultraviolet diagnostics allows deep penetration into the Z-pinch plasma at stagnation. End-on probing reveals the complicated structure of the precursor. Strong magnetohydrodynamic instabilities are found in a dense pinch hidden in the trailing plasma. Small-scale instabilities are seen in the Z-pinch plasma with micrometer resolution. Probing of the pinch from four directions shows asymmetrical trailing plasma in some configurations of wire arrays. Faraday rotation diagnostics reveals the magnetic fields and the current distribution in the plasma of the precursor and Z-pinch. Redistribution of current in the trailing plasma is seen during kink and sausage instabilities in the stagnation stage. The formation of micropinches and hot spots in the Z-pinch is analyzed with coupled laser and x-ray diagnostics. Different laser diagnostics allow the study of Z-pinch plasmas in all stages, including fast dynamics and instabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A semi-analytical model for laser induced densification in fused silica at elevated temperatures

A semi-analytical model for deterministic surface smoothing of fused silica below the evaporation temperature threshold is presented. Using this model, a method for calculating deterministic track depths for laser polishing fused silica is derived and validated with experiments. In this work, model predictions were in good agreement with experiment across varying laser preheating temperature and power. With the semi-analytical method presented here, deterministic laser smoothing can be achieved in the densification regime to close the process loop of laser polishing.

36 MATERIALS SCIENCE↗

The physical parameters of the retired a star HD 185351

We report here an analysis of the physical stellar parameters of the giant star HD 185351 using Kepler short-cadence photometry, optical and near infrared interferometry from CHARA, and high-resolution spectroscopy. Asteroseismic oscillations detected in the Kepler short-cadence photometry combined with an effective temperature calculated from the interferometric angular diameter and bolometric flux yield a mean density ρ{sub *} = 0.0130 ± 0.0003 ρ{sub ☉} and surface gravity log g = 3.280 ± 0.011. Combining the gravity and density we find R {sub *} = 5.35 ± 0.20 R {sub ☉} and M {sub *} = 1.99 ± 0.23 M {sub ☉}. The trigonometric parallax and CHARA angular diameter give a radius R {sub *} = 4.97 ± 0.07 R {sub ☉}. This smaller radius, when combined with the mean stellar density, corresponds to a stellar mass 1.60 ± 0.08 M {sub ☉}, which is smaller than the asteroseismic mass by 1.6σ. We find that a larger mass is supported by the observation of mixed modes in our high-precision photometry, the spacing of which is consistent only for M {sub *} ≳ 1.8 M {sub ☉}. Our various and independent mass measurements can be compared to the mass measured from interpolating the spectroscopic parameters onto stellar evolution models, which yields a model-based mass M {sub *,} {sub model} = 1.87 ± 0.07 M {sub ☉}. This mass agrees well with the asteroseismic value, but is 2.6σ higher than the mass from the combination of asteroseismology and interferometry. The discrepancy motivates future studies with a larger sample of giant stars. However, all of our mass measurements are consistent with HD 185351 having a mass in excess of 1.5 M {sub ☉}.

79 ASTRONOMY AND ASTROPHYSICS↗

VALIDATION OF 12 SMALL KEPLER TRANSITING PLANETS IN THE HABITABLE ZONE

We present an investigation of 12 candidate transiting planets from Kepler with orbital periods ranging from 34 to 207 days, selected from initial indications that they are small and potentially in the habitable zone (HZ) of their parent stars. Few of these objects are known. The expected Doppler signals are too small to confirm them by demonstrating that their masses are in the planetary regime. Here we verify their planetary nature by validating them statistically using the BLENDER technique, which simulates large numbers of false positives and compares the resulting light curves with the Kepler photometry. This analysis was supplemented with new follow-up observations (high-resolution optical and near-infrared spectroscopy, adaptive optics imaging, and speckle interferometry), as well as an analysis of the flux centroids. For 11 of them (KOI-0571.05, 1422.04, 1422.05, 2529.02, 3255.01, 3284.01, 4005.01, 4087.01, 4622.01, 4742.01, and 4745.01) we show that the likelihood they are true planets is far greater than that of a false positive, to a confidence level of 99.73% (3σ) or higher. For KOI-4427.01 the confidence level is about 99.2% (2.6σ). With our accurate characterization of the GKM host stars, the derived planetary radii range from 1.1 to 2.7 R {sub ⊕}. All 12 objects are confirmed to be in the HZ, and nine are small enough to be rocky. Excluding three of them that have been previously validated by others, our study doubles the number of known rocky planets in the HZ. KOI-3284.01 (Kepler-438b) and KOI-4742.01 (Kepler-442b) are the planets most similar to the Earth discovered to date when considering their size and incident flux jointly.

79 ASTRONOMY AND ASTROPHYSICS↗

Refractive Index Seen by a Probe Beam Interacting with a Laser-Plasma System

Here, we report the first complete set of measurements of a laser-plasma optical system’s refractive index, as seen by a second probe laser beam, as a function of the relative wavelength shift between the two laser beams. Both the imaginary and real refractive index components are found to be in good agreement with linear theory using plasma parameters measured by optical Thomson scattering and interferometry; the former is in contrast to previous work and has implications for crossed-beam energy transfer in indirect-drive inertial confinement fusion, and the latter is measured for the first time. The data include the first demonstration of a laser-plasma polarizer with 85$-$87% extinction for the particular laser and plasma parameters used in this experiment, complementing the existing suite of high-power, tunable, and ultrafast plasma-based photonic devices.

42 ENGINEERING↗

Cumulative fidelity of large-momentum-transfer clock atom interferometers in the presence of laser noise

Clock atom interferometry is an emerging technique in precision measurements that is particularly well suited for sensitivity enhancement through large momentum transfer (LMT). While current systems have demonstrated momentum separations of several hundreds of photon momenta, next-generation quantum sensors are targeting an LMT enhancement factor beyond 10 4 . However, the viability of LMT clock interferometers has recently come into question due to the potential impact of laser frequency noise. Here, in this work, we resolve this concern by analyzing the cumulative fidelity of sequential state inversions in an LMT atom interferometer. We show that the population error from 𝑛 pulses applied from alternating directions scales linearly with 𝑛. This is a significant advantage over the 𝑛 2 scaling that occurs when probing a two-level system 𝑛 times from the same direction. We further show that contributions to the interferometer signal from parasitic paths generated by imperfect pulses are negligible, for any loss mechanism. These results establish that laser frequency noise is not a practical limitation for the development of high-fidelity LMT clock atom interferometers.

Mach-Zehnder atom interferometry↗

Naturally stable Sagnac–Michelson nonlinear interferometer

Interferometers measure a wide variety of dynamic processes by converting a phase change into an intensity change. Nonlinear interferometers, making use of nonlinear media in lieu of beamsplitters, promise substantial improvement in the quest to reach the ultimate sensitivity limits. Here we demonstrate a new nonlinear interferometer utilizing a single parametric amplifier for mode mixing conceptually, a nonlinear version of the conventional Michelson interferometer with its arms collapsed together. We observe up to 99.9% interference visibility and find evidence for noise reduction based on phase-sensitive gain. As a result, our configuration utilizes fewer components than previous demonstrations and requires no active stabilization, offering new capabilities for practical nonlinear interferometric-based sensors.

47 OTHER INSTRUMENTATION↗

Modeling and Design of a Sub-Nyquist PDV Digitization System

Photon-Doppler Velocimetry (PDV) uses interferometry of a transmitted optical signal reflected from a fast-moving device under test (DUT) to generate a product signal at a doppler shifted frequency which is proportional to the velocity of the object being measured. The technique has applications in shock physics, where it is used to measure fast-moving objects over a short lifespan of travel, such as a bullet, shrapnel, or other shock accelerated object.

42 ENGINEERING↗

ARMADA. I. Triple Companions Detected in B-type Binaries α Del and ν Gem

Ground-based optical long-baseline interferometry has the power to measure the orbits of close binary systems at ∼10 μas precision. This precision makes it possible to detect “wobbles” in the binary motion due to the gravitational pull from additional short-period companions. We started the ARrangement for Micro-Arcsecond Differential Astrometry (ARMADA) survey with the Michigan Infra-Red Combiner (MIRC)/MIRC-X instrument at the Center for High Angular Resoloution Astronomy (CHARA) array for the purpose of detecting giant planets and stellar companions orbiting individual stars in binary systems. We describe our observations for the survey, and introduce the wavelength calibration scheme that delivers precision at the tens of microarcseconds level for <02 binaries. We test our instrument performance on a known triple system, κ Peg, and show that our survey is delivering a factor of 10 better precision than previous similar surveys. We present astrometric detections of tertiary components to two B-type binaries: a 30 day companion to α Del, and a 50 day companion to ν Gem. We also collected radial velocity data for α Del with the Tennessee State University Automated Spectroscopic Telescope at Fairborn Observatory. We are able to measure the orbits and masses of all three components in these systems. We find that the previously published radial velocity orbit for the inner pair of ν Gem is not consistent with our visual orbit. The precision achieved for these orbits suggests that our ARMADA survey will be successful at discovering new compact triple systems to A/B-type binary systems, leading to better statistics of hierarchical system architectures and formation history.

47 OTHER INSTRUMENTATION↗

Applications of optical holography to applied mechanics.

This paper provides a brief summary of applications of optical holography and holographic interferometry to applied solid mechanics. Basic equations commonly used in fringe interpretation are described and used to reduce the data contained on holographic interferograms. A comparison of data obtained holographically with analytical prediction is given wherever possible. Applications contained herein include front surface physics, study of bomb breakup, transverse wave propagation, study of mode shapes of panels at elevated temperatures, nondestructive testing, and vibration analysis.

Aprahamian, R.↗

Dimensional stability of fused silica and several ultralow expansion materials

Description of a program of measurements of the dimensional stability of fused silica and several ultralow thermal expansion materials. The two techniques used are: (1) Fizeau interferometry employed by NBS-Corning, and (2) Fabry-Perot interferometry employed by the Optical Science Center, University of Arizona. In the latter, a measurement accuracy of one part in a billion is sought.

Jacobs, S. F.↗

TOPSAT: Global space topographic mission

Viewgraphs on TOPSAT Global Space Topographic Mission are presented. Topics covered include: polar region applications; terrestrial ecosystem applications; stereo electro-optical sensors; space-based stereoscopic missions; optical stereo approach; radar interferometry; along track interferometry; TOPSAT-VISTA system approach; ISARA system approach; topographic mapping laser altimeter; and role of multi-beam laser altimeter.

Vetrella, Sergio↗