Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “operational processes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Multi-pass flow-through reductive catalytic fractionation

Reductive catalytic fractionation (RCF) is a promising lignin-first biorefining strategy that selectively extracts and depolymerizes lignin from whole biomass. Flow-through (FT)-RCF enables physical separation of the biomass and catalyst, but this process configuration typically operates at high solvent-to-biomass ratios. Here, we demonstrate multi-pass FT-RCF, wherein the lignin-enriched solvent obtained after an initial FT-RCF step is recycled and used in subsequent FT-RCF without intermediate lignin recovery. Multi-pass FT-RCF reduces the solvent-to-biomass ratio from 48 to 1.9 L/kg, which is a lower solvent loading than is accessible in batch reactors, without negative impacts on delignification and monomer yield with up to 12 wt % lignin in the solvent. Overall, this work demonstrates that solvent demand in RCF processes, which is a key cost and energy driver to enable this process at scale, can be reduced by recycling lignin oil between RCF reactions.

09 BIOMASS FUELS↗

Analyses of hot/warm CO2 removal processes for IGCC power plants

Abstract Compared with a pulverized coal power plant, the integrated gasification combined cycle (IGCC) has several advantages, including, among others better environmental performance and low CO 2 capture cost. Hot/warm CO 2 removal from syngas has also been a subject of research due to its potentially higher thermal efficiency. In this study, we proposed a generic adsorption based hot/warm CO 2 removal process for IGCC power plants. Through analyses of the proposed generic process we have demonstrated that higher temperature of the hot/warm CO 2 removal process will results in larger heat of adsorption, which in turns may increase energy consumption of the process. Under most of the operating temperature range, hot/warm CO 2 removal process will lead to more electricity loss compared to the baseline Selexol process. However, if the adsorption step takes place at a temperature close to or higher than the highest steam temperature in steam cycle, our analysis indicates that the process may lead to minimal electricity loss. The study also provided some other insights into the pathways for hot/warm CO 2 removal process to improve its energy performance through process and sorbent designs. Graphical Abstract

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Elucidating Compositional Differences in Halide Perovskites for Normal and Inverted Perovskite Solar Cells

Over the recent few years, extensive research efforts have shifted from normal (n-i-p) to inverted (p-i-n) perovskite solar cells (PSCs), owing to their promising efficiency and operational stability, enabled by low-temperature processing. Despite a fundamentally identical operation principle (only structurally inverted), the optimized perovskite compositions for normal and inverted PSCs differ significantly across the literature, suggesting an underlying design principle for perovskite composition. Here, we unveil the role of cesium cation in enhancing interfacial contact between the perovskite layer and the underlying hole-transporting layer (HTL) in inverted PSCs. Comprehensive in situ and device characterization reveal that cesium incorporation promotes the formation of initial nucleation seeds for heterogeneous nucleation at the perovskite/hydrophobic HTL interface, thereby improving their contact. The resulting compositional heterogeneity explains the focus of recent studies on resolving this issue. This study provides mechanistic insight into designing perovskite compositions to further enhance the performance and longevity of PSCs.

Park, Keonwoo↗

Technical Gaps in Hanford High-Level Waste Solids Settling Behavior and Settling Time Evaluation for Direct Feed High-Level Waste (DFHLW) Operations

Settling of high-level waste (HLW) solids in process vessels is a key conceptual process step in providing HLW feed directly to the Hanford Waste Treatment and Immobilization Plant (WTP) HLW Vitrification Facility. Direct Feed High-Level Waste (DFHLW) is a potential approach to initiating HLW vitrification prior to completing of the WTP Pretreatment Facility. Settling would be used with subsequent supernatant decant to concentrate HLW feed. To support planning for DFHLW, Washington River Protection Solutions (WRPS) requested support from the Pacific Northwest National Laboratory to evaluate the current data set available to predict the time needed for HLW solids to settle, to identify gaps in the understanding and predictive capability of HLW solids waste settling times, and to provide scoping estimates of the potential settling time. Eight technical gaps were identified for predicting settling times and characteristics of the formed sediment layers including: Gap 1: In-Tank Settling Rates Faster than Settling of Laboratory Samples, Gap 2: Effect of Sludge Leaching/Washing on Predicted Settling Times, Gap 3: Predicting Waste Settling from Waste Chemistry (Waste Type), Gap 4: Predicting Waste Settling from Particle Size and Density Distributions (PSDDs), Gap 5: Insufficient Laboratory and In-Tank Settling Data to Represent Hanford Waste, Gap 6: Methods for Real-Time, In-Tank Tracking of Settling, Gap 7: Prediction of Sediment Erosion Resistance as a Function of Settling Time, and Gap 8: Prediction of Sediment Solids Content as a Function of Settling Time. In addition to the data gaps, an overarching observation of the settling rate and settled layer data is the significant variation in behavior. At similar solids concentrations, settling rates can vary by as much as 3 orders of magnitude depending on the source waste tank, and significantly different settling rates are noted between laboratory and in situ tests for the same waste tank. The range of average solids concentration in existing HLW sediment, which may have been quiescent for decades, can vary from less than 7 wt% to greater than 74 wt% solids. The shear strengths (or yield stresses) measured on laboratory samples range from less than 27 Pa to greater than 6400 Pa. These variations can challenge process planning for the application of a settle/decant process for DFHLW. This report describes the significance of the gaps to the settle/decant process and presents uncertainties by way of examples. Potential technical approaches for resolving these gaps are described and the estimated difficulty in resolving these gaps is evaluated. Based on the significance of the gap and the difficulty of resolution, recommendations are made to address specific gaps. Scoping estimates of the potential settling times for DFHLW solids have been made based on the existing data set with its associated gaps. Depending on the process vessel depth and final sediment concentration, substantial fractions of the scoping estimate results for settling times for characterized HLW exceed the 2-week period that has been previously assumed for process planning. There is also significant disparity, potentially greater than a factor of 5000 difference, in the estimated settling times depending on process vessel depth and final sediment solid concentration. This variation in results underscores the significance of the identified gaps and uncertainties with respect to process planning for utilizing settle/decant operations for DFHLW.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Biotic degradation of acetonitrile. Limitations, controls and conversion rates

This document has been prepared to support Washington River Protection Solutions (WRPS) in their evaluation of technologies to remediate organic compounds in the Liquid Effluent Retention Facility (LERF)/Effluent Treatment Facility (ETF) during direct feed low activity waste (DFLAW) operations at Hanford. This report summarizes the results of a review of the available literature describing aerobic and anaerobic biological treatment of acetonitrile and proposes a test matrix to evaluate microbial degradation rates of acetonitrile. Numerous studies describe acetonitrile degradation by pure culture strains of bacteria, fungi, and yeast; however, the purpose of this review was to provide estimations of degradation under conditions that more closely approximate the Liquid Effluent Retention Facility (LERF) basins at the Hanford Site. To this end, documented limitations, controls, and conversion rates are summarized for mixed and natural microbial communities being maintained or operated as a biological treatment for wastewater processing. Based on the literature evaluation, the inherent capacity and rates of microbial degradation of acetonitrile are sufficiently high that if applied in the LERF basins, acetonitrile removal would be achieved. To be clear, though, published studies have not been conducted under conditions that approximate or that could be directly related to the LERF basins. Thus, a focused test matrix the encompasses LERF relevant conditions to specifically measure microbial degradation of acetonitrile is proposed and the results would provide the strong technical justification for use of this low-cost efficient biological process at LERF during DFLAW operations and beyond.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Blockchain Empowered Provenance Framework for Sensor Identity Management and Data Flow Security in Fossil-based Power Plants

The overall goals of this project are divided into 3 important phases. First, a peer-to-peer SCADA network is to be established where identity profile of sensors from fossil-power plants will be stored in an immutable manner in order to verify data flow integrity in real time. Second, it is aimed to develop a Blockchain-based provenance platform to audit equipment operations along with data and process integrity violations. In this phase, various operational rules will be incorporated in the ledger on behalf of the operating sensor so its abnormal use can be easily detected. In addition, it is aimed to achieve provenance when the rate of transactions is exceedingly high, thus enabling to design a scalable provenance scheme that can work in real time when number of data collecting points or sensor units increase in fossil-based power plants. Finally, a working testbed will be developed to integrate the Blockchain platform with sensor-based fossil power plant comprising of Remote Terminal Units (RTU) and SCADA devices. Using multiple Raspberry-PIs mimicking the role of RTUs that are interfaced with multiple sensors devices will be deployed to serve as a critical component of fossil power plant and the performance metrics such as throughput, latency, bootstrapping time, etc., will be evaluated on the testbed.

20 FOSSIL-FUELED POWER PLANTS↗

Inline Rolling Shear Alignment: Deposition and Long-Range Order of Block Polymer Templates in a Fast, Single-Step Process

We report the first demonstration of a rapid, single-step technique to align block polymer, thin-film nanostructures that is amenable to continuous speeds ≥10 mm/s. This method, termed Inline Rolling Shear Alignment (IRSA), uses an elastomeric roller coupled with an electric hysteresis brake to shear films before the casting solvent fully evaporates, and it can enable high throughput, large-area manufacturing of patterns such as nanowire templates. IRSA is adaptable to various polymer systems including diblock and triblock polymers, and a post-shear annealing step can yield high-quality nanostructures with orientation parameters >0.99 and defect densities as low as 5 defect-pairs/μm 2 . To demonstrate the effectiveness of IRSA, platinum nanowires were produced from this rapid deposition and alignment approach using poly(styrene-b-2-vinylpyridine), followed by open-air, atmospheric-pressure plasma etching. Furthermore, this integrated concept, with 50x faster operation than existing processes, could be leveraged for cost-effective manufacturing of macroscopically aligned nanostructures in roll-to-roll systems.

36 MATERIALS SCIENCE↗

Energy and exergy analysis of multi-stage vacuum membrane distillation integrated with mechanical vapor compression

Membrane distillation (MD) is a promising candidate for desalinating hypersaline brine, but its poor energy efficiency has remained a major barrier for widespread application. One possible solution to this issue is to recover the latent heat in the process. In this work, a multi-stage vacuum MD (MSVMD) was integrated with a mechanical vapor compressor (MVC) to enhance the latent heat recovery, and the energetic and exergetic performance of this integrated process was examined. A comprehensive energy and exergy analysis is provided to compare MSVMD and MSVMD-MVC processes for desalination of hypersaline brine. This analysis was conducted by examining the effect of the compression ratio on the energetic and exergetic performance, and the findings are reported in terms of specific thermal energy consumption (STEC), specific electricity consumption (SEC), and exergetic efficiency. The energy analysis shows that thermal energy consumption can be reduced as the compression ratio increases, due to the enhancement of latent heat recovery. The MSVMD-MVC process can be operated in a steady-state condition, without the need for thermal heat input; with STEC and SEC of 0 and 49 kWh/m 3 at the feed temperature of 50 °C and MVC compression ratio of 2.14. Moreover, exergy analysis demonstrates the efficacy of the eNRTL model in exergy calculation. Exergy destruction can be greatly reduced by increasing the compression ratio to an optimal value. For high salinity brine (124 g/L), MSVMD-MVC achieved a higher exergetic efficiency of 6.85%, compared to 2.42% in MSVMD. Furthermore, the result suggests that the application of MVC can intensify the energy efficiency and exergetic efficiency of the MSVMD system, although this process cannot outperform the current desalination technologies from the standard primary energy point of view.

42 ENGINEERING↗

Enabling fast-charging of lithium-ion batteries through printed electrodes

It has been well recognized that introducing secondary porous networks (SPNs) into the electrodes can effectively improve the electrochemical performance of lithium-ion batteries (LIBs), especially under fast-charging operations. However, the process complexity and high cost limit the commercial success of advanced electrodes with SPNs. To address this issue, we developed a facile screen-printing process to produce structured graphite electrodes with SPNs. The experimental results demonstrated that, by tuning the diameter and center-to-center (C2C) distance of emulsion dots on the stencil screen, the pore diameters and C2C pore distances of SPNs in screenprinted electrodes can be precisely controlled in the range of 100 mu m to 1 mm and 100 mu m to 3 mm respectively. In addition, the SPNs with hexagonal and square-shape pore alignments have also been imprinted onto the electrode coatings through adjusting the patterns of screen stencils. Used as anodes, the printed graphite electrodes demonstrated significantly reduced overpotential and voltage fluctuation under fast-charging operations from 2C to 6C. Coupled with LiNi 0.6 Mn 0.2 Co 0.2 O 2 (NMC622) cathodes, the full cells with printed graphite anodes exhibited an unprecedently stable performance with almost no capacity decay up to 170 cycles when charged to 80 % SOC at 2C. Observations from electron microscopy showed plated lithium undetectable at the surface of printed graphite electrodes after numerous cycles. The electrochemical analysis on the voltage evolution during the cell rest period indicated the significantly delayed onset of lithium plating in the presence of printed graphite electrodes. In conclusion, all these results suggest that the significantly improved cell performance is associated with the shortened Li-ion diffusion distance, reduced polarization and suppressed Li plating in the printed electrodes with patterned SPNs.

25 ENERGY STORAGE↗

High Value Opportunities to Advance Automation in Electric Grid Control Rooms

Grid operators and electric utilities are increasingly driven to develop automated processes and introduce decision support tools to reduce cognitive demand on System Operations staff and aid in the operational decision-making process. However, System Operation staff are traditionally hesitant to implement and accept new solutions, automation processes, and tools within the control room. This paper explores high-value opportunities to advance automation in electric grid control rooms for the purpose of improving grid safety, reliability, and resiliency during normal and emergency operating conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

New perspectives on materials and device dynamics using time-resolved full-field diffraction X-ray imaging

Understanding how materials evolve during synthesis, processing, or device operation requires experimental access to structural dynamics across wide ranges of length and time scales, often in bulk samples or even within packaged devices. Time-resolved full-field diffraction X-ray microscopy has recently emerged as a powerful way to meet this need by combining the penetration and structural sensitivity of X-ray diffraction with objective-lens-based magnification, sensitive high-resolution X-ray imaging detectors, and pump-probe and real-time imaging strategies. Advances in full-field X-ray diffraction microscopy, often termed dark-field X-ray microscopy (DFXM), enable simultaneous imaging of extended fields of view while retaining crystallographic selectivity. Time-resolved DFXM promises to enable advances in materials processing and dynamics, electrochemical and photochemical processes, and the design of electronic devices. This Perspective summarizes the key instrumental concepts that define the performance of these methods, including the choice of imaging optics, detector considerations, and the impact of source time structure at synchrotron light sources and X-ray free-electron lasers (XFELs). We discuss the simultaneous use of complementary imaging modes that are increasingly used in practice. The early demonstrations of the potential of time-resolved DFXM include real-time defect and grain-boundary dynamics during metal annealing, stroboscopic imaging of functional devices with high strain sensitivity, and ultrafast pump-probe implementations at XFELs that directly visualize acoustic-wave propagation and energy dissipation in bulk crystals.

Dark-field X-ray microscopy↗

Session 077 - Panel: Wednesday US DOE Featured Site: Lexington, KY Office (Portsmouth and Paducah Sites) (R1.14)

This panel featured the DoE's Portsmouth Paducah Project Office (PPPO), which is responsible for the management and cleanup of at the Portsmouth, Ohio and Paducah, Kentucky former Gaseous Diffusion Plant sites. Portsmouth is primed for the first major skyline change at the site the upcoming demolition of the X-326 process building and initial operations of the Onsite Waste Disposal Facility. The Paducah site is working on the C-400 city block initiative allowing DOE to tackle the main source of groundwater contamination at the site, in conjunction with deactivation and demolition of the C-400 Cleaning Building. PPPO's DUF6 conversion plants have 7 lines in continuous operation at both sites providing the opportunity to ramp up cylinder processing. Panelists with presentations: DOE PPO Update (Robert Edwards, Joel Bradburne); Portsmouth/Paducah Project Office (PPPO) (Joel Bradburne, Robert Edwards); PADUCAH (Jennifer Woodard, Myrna Espinosa Redfield); Depleted Uranium Hexafluoride Conversion Project (Reinhard Knerr, Zack Smith); Paducah Deactivation and Remediation Project (Myrna Espinosa Redfield); Mid-America Conversion Services - Seven Lines One Project (Zack Smith)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FY23 ION Based Approaches to Address Labor and Knowledge Retention

This study will seek to outline the current problem facing the nuclear industry related to staffing, training, and retaining the necessary workforce for long-term sustainability. A review of published reports and knowledge gained by working in the nuclear energy sector will form the basis for this scoping study. This study will not seek to draw any conclusions regarding the underlying causes of these personnel issues but will attempt to ask questions and help outline future research. The Integrated Operations for Nuclear business model provides opportunities to partially mitigate some of the current issues facing staffing the nuclear fleet. Upgrading safety and control systems from analog to digital as advocated by the Integrated Operations for Nuclear process allows the nuclear facility to compete for the best and brightest candidates and offers them a broad and sustainable career path where their skills can be valued and utilized in the broader industrial sectors. This study will seek to identify the primary reasons that the nuclear industry is facing this labor crisis and seek to identify possible solutions that will be fully evaluated in future research.

42 ENGINEERING↗

PUR-1 Water Processing and Cooling System Upgrade

The project objective was to purchase equipment related to the safety and operational capability of PUR-1. Following a 10x power uprate and the return to an active operational cycle, a water process system replacement is required to maintain the bulk coolant temperature within the bounds of the Technical Specification limit at the PUR-1. The replacement project will ensure safety and availability of the PUR-1 for long duration operational cycles and applicability to the largest possible customer base. The equipment to be purchased for this work includes a new main coolant pump rated to at least 30 gallons per minute, a heat exchanger to remove heat from the primary coolant, and a chiller system to release the heat to the environment via city water. The proposed system exactly replicates the installed system with a slight increase in capacity.

42 ENGINEERING↗

Jacobian-based Model Diagnostics and Application to Equation Oriented Modeling of a Carbon Capture System

Equation-oriented (EO) modeling has the potential to enable the effective design and optimization of the operation of advanced energy systems. However, advanced modeling of energy systems results in a large number of variables and non-linear equations, and it can be difficult to search through these to identify the culprit(s) responsible for convergence issues. The Institute for the Design of Advanced Energy Systems Integrated Platform (IDAES-IP) contains a tool to identify poorly scaled constraints and variables by searching for rows and columns of the Jacobian matrix with small L2-norms so they can be rescaled. A further singular value decomposition can be per-formed to identify degenerate sets of equations and remaining scaling issues. This work presents an EO model of a flowsheet developed for post-combustion carbon capture using a monoethanolamine (MEA) solvent system as a case study. The IDAES diagnostics tools were successfully applied to this flowsheet to identify problems to improve model robustness and enable the optimization of process design and operating conditions of a carbon capture system.

Allan, Douglas↗

The Production of Low Ash Coals Using the Hydrophobic-Hydrophilic Separation Process with Novel Developments

Froth flotation is a common mineral processing method in coal preparation. This process becomes less efficient, however, as particle size is reduced, and ultrafine particles are often discarded prior to froth flotation, contributing to a substantial amount of coal waste in impoundments. Because of the land-use and risk of an impoundment failure, these impoundments pose an environmental liability. To address ultrafine coal rejection, researchers at Virginia Tech developed the hydrophobic-hydrophilic separation (HHS) process. Unlike in froth flotation, HHS uses an organic solvent to separate and dewater hydrophobic particles from hydrophilic minerals. Past work on the HHS process yielded promising results. In particular, the HHS process has produced a low-ash (<2%) and low moisture (<8%) product, which is a viable feed stock for carbon products. In this work, an investigation of the effects of auxiliary processes on the HHS process was conducted. The auxiliary processes included grinding, pre-concentration, and reagent conditioning. This work also contains an investigation on the interaction between two primary unit operations in the HHS process: oil agglomeration and de-emulsification. Lastly, to make the HHS process more viable for commercial scale-up, a novel unit operation was developed and tested that performs comparably to the current HHS process.

01 COAL, LIGNITE, AND PEAT↗

Options for the Removal of Cesium and Strontium from Acidic Uranyl Sulfate Solutions from Molybdenum-99 Production

A small laboratory-scale column process aimed at removing fission products from prototypical acidic sulfate solution wastes from a prototypical Mo-99 recovery process has been operated in a radioactive materials hood at Savannah River National Laboratory. This equipment has been operated with realistic concentrations of uranium (0.4 wt % 235 U), plutonium ( 239 Pu), neptunium ( 237 Np), non-radioactive surrogates of common fission products (including Cs and Sr) and two promising absorbents AMP-PAN and CST R91290-B. The goal of this work was to demonstrate the removal and concentration of high specific activity isotopes which are expected to dominate the classification of the low-level waste from the production of 99 Mo. Both AMP-PAN and CST R9120-B are attractive absorbents for the removal of 137 Cs from an acidic sulfate waste stream. They do not provide a solution for the removal of 90 Sr from the acidic solutions, but CST should be investigated at a higher pH. Limited removal of transuranic species and almost no removal of uranium was observed in this testing. This could be important due to the relatively large amount of uranium expected to be present in such waste streams. The capacity of these absorbents for 137 Cs will likely be dependent on the Cs concentration in the solutions processed but loading in the range of 0.2 to 5 mg Cs per gram of absorbent appears to be achievable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Data-Driven Adaptive Damping Controller for Wind Power Plants with Doubly-Fed Induction Generators

This paper presents an adaptive damping controller for wind power plants in which the turbines are equipped with doubly-fed induction generators. The controller is designed to respond to an input control signal that is triggered according to the system operating conditions. A processing unit continuously estimates the electromechanical modes of oscillation based on real-time streaming data acquired from a phasor measurement unit that is strategically positioned on the grid. The decision to trigger (or not trigger) the control signal is automatic, based on the relative damping of the dominant mode. The modes are estimated using the dynamic mode decomposition algorithm with time-delay embedding. Numerical simulations performed on the two-area system demonstrate that the proposed controller enhances the rotor angle stability for both small-signal and large disturbances, and is adaptive to changing grid conditions.

damping controller↗