Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nuclear pulse processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Review of current neutron detection systems for emergency response

Neutron detectors are utilized in a myriad of applications—from safeguarding special nuclear materials (SNM) to determining lattice spacing in soft materials. The transformational changes taking place in neutron detection and imaging techniques in the last few years are largely being driven by the global shortage of helium-3 ( 3 He). This article reviews the status of neutron sensors used specifically for SNM detection in radiological emergency response. These neutron detectors must be highly efficient, be rugged, have fast electronics to measure neutron multiplicity, and be capable of measuring direction of the neutron sources and possibly image them with high spatial resolution. Neutron detection is an indirect physical process: neutrons react with nuclei in materials to initiate the release of one or more charged particles that produce electric signals that can be processed by the detection system. Therefore, neutron detection requires conversion materials as active elements of the detection system; these materials may include boron-10 ( 10 B), lithium-6 ( 6 Li), and gadollinium-157 ( 157 Gd), to name a few, but the number of materials available for neutron detection is limited. However, in recent years, pulse-shape-discriminating plastic scintillators, scintillators made of helium-4 ( 4 He) under high pressure, pillar and trench semiconductor diodes, and exotic semiconductor neutron detectors made from uranium oxide and other materials have widely expanded the parameter space in neutron detection methodology. In this article we will pay special attention to semiconductor-based neutron sensors. Finally, modern microfabricated nanotubes covered inside with neutron converter materials and with very high aspect ratios for better charge transport will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rotation in attosecond vibronic coherence spectroscopy for molecules

Abstract Excitation or ionization of a molecule by ultrafast laser pulses can create a superposition of electronic states, whose dynamics is influenced by the interplay of electronic coherence and nuclear motion, resulting in charge migration and possibly charge transfer. Probing the vibronic coherence is therefore vital to monitoring electronic dynamics and controlling chemical reactivity, as recently demonstrated in molecules via attosecond transient absorption spectroscopy (ATAS). However, theories supporting the interpretation of ATAS experiments neglect the effects of molecular rotation, often leading to inaccurate interpretation of experimental data. Here, we develop a comprehensive theory for ATAS of molecules encompassing the entire pump-probe process. Applying the theory to N 2 , we demonstrate that the emergence of coherent signals critically depends on the consideration of molecular rotation. This work contributes to close the gap between theory and ATAS experiments, paving the way for monitoring electronic motion and controlling chemical reactivity in diverse molecular systems.

Physics↗

Structural dynamics of a thermally silent triiron( II ) spin crossover defect grid complex

The structural evolution of spin crossover (SCO) complexes during their spin transition at equilibrium and out-of-equilibrium conditions needs to be understood to enable their successful utilisation in displays, actuators and memory components. In this study, diffraction techniques were employed to study the structural changes accompanying the temperature increase and the light irradiation of a defect [2 × 2] triiron(II) metallogrid of the form [Fe II 3 L H 2 (HL H ) 2 ](BF 4 ) 4 ·4MeCN (FE3), L H = 3,5-bis{6-(2,2'-bipyridyl)}pyrazole. Although a multi-temperature crystallographic investigation on single crystals evidenced that the compound does not exhibit a thermal spin transition, the structural analysis of the defect grid suggests that the flexibility of the grid, provided by a metal-devoid vertex, leads to interesting characteristics that can be used for intermolecular cooperativity in related thermally responsive systems. Time-resolved photocrystallography results reveal that upon excitation with a ps laser pulse, the defect grid shows the first two steps of the out-of-equilibrium process, namely the photoinduced and elastic steps, occurring at the ps and ns time scales, respectively. Similar to a previously reported [2 × 2] tetrairon(II) metallogrid, FE3 exhibits a local distortion of the entire grid during the photoinduced step and a long-range distortion of the lattice during the elastic step. Although the lifetime of the pure photoinduced high spin (HS) state is longer in the tetranuclear grid than in the defect grid, suggesting that the global nuclearity plays a crucial role for the lifetime of the photoinduced species, the influence of the co-crystalising solvent on the lifetime of the photoinduced HS state remains unknown. This study sheds light on the out-of-equilibrium dynamics of a thermally silent defect triiron SCO metallogrid.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low latency optical-based mode tracking with machine learning deployed on FPGAs on a tokamak

Active feedback control in magnetic confinement fusion devices is desirable to mitigate plasma instabilities and enable robust operation. Optical high-speed cameras provide a powerful, non-invasive diagnostic and can be suitable for these applications. Here, in this study, we process high-speed camera data, at rates exceeding 100 kfps, on in situ field-programmable gate array (FPGA) hardware to track magnetohydrodynamic (MHD) mode evolution and generate control signals in real time. Our system utilizes a convolutional neural network (CNN) model, which predicts the n = 1 MHD mode amplitude and phase using camera images with better accuracy than other tested non-deep-learning-based methods. By implementing this model directly within the standard FPGA readout hardware of the high-speed camera diagnostic, our mode tracking system achieves a total trigger-to-output latency of 17.6 μs and a throughput of up to 120 kfps. This study at the High Beta Tokamak-Extended Pulse (HBT-EP) experiment demonstrates an FPGA-based high-speed camera data acquisition and processing system, enabling application in real-time machine-learning-based tokamak diagnostic and control as well as potential applications in other scientific domains.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rubidium and Zirconium Production in Massive AGB Stars

A recent survey of a large sample of massive Galactic asymptotic giant branch (AGB) stars shows that significant overabundances of rubidium (up to 100 times solar), but merely solar zirconium, are present in these stars. These observations can set constraints on our theoretical notion of the slow neutron capture process (the s process) in AGB stars, as well as on the rates of the neutron capture reactions involved in the production of Rb and Zr. We use the Monash nucleosynthesis code with a recently extended network to try to reproduce these observations. We present results for AGB stars of masses 5, 6, and 6.5 M{center_dot} and solar metallicity. We also show results for different available choices of the neutron capture rates, as well as for the possible inclusion of a partial mixing zone (PMZ), leading to the activation of the {sup 13}C neutron source. We find increasing Rb overabundances with increasing stellar mass, as observed, but we are far from matching the highest observed Rb enhancements. Inclusion of a PMZ increases the Rb abundance, but also produces an overabundance of Zr, contrary to what is observed. Only if the third dredge up efficiency remains as high as before the onset of the superwind phase during the final few pulses of a massive AGB star, can we match the highest [Rb/Fe] ratios observed by Garcia-Hernandez et al. [l]. A better understanding of the third dredge up efficiency with decreasing envelope mass for massive AGB stars is essential for further investigation of this issue.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Enhanced High Resolution RBS System

Improvements in full spectrum resolution with the second NEC high resolution RBS system are summarized. Results for 50 A ring TiN/HfO films on Si yielding energy resolution on the order of 1 keV are also presented. Detector enhancements include improved pulse processing electronics, upgraded shielding for the MCP/RAE detector, and reduced noise generated from pumping. Energy resolution measurements on spectra front edge coupled with calculations using 0.4mStr solid angle show that beam energy spread at 400 KeV from the Pelletron registered accelerator is less than 100 eV. To improve user throughput, magnet control has been added to the automatic data collection. Depth profiles derived from experimental data are discussed. For the thin films profiled, depth resolutions were on the Angstrom level with the non-linear energy/channel conversions ranging from 100 to 200 eV.

43 PARTICLE ACCELERATORS↗

ATF Transient Prescription Tests in TREAT

EXECUTIVE SUMMARY The Transient Reactor Test facility (TREAT) was constructed in the late 1950’s and provided thousands of transient irradiations before being placed in standby mode in 1994. In 2017, it resumed operation in order to reclaim its crucial role in nuclear-heated safety research. TREAT is a transient reactor where inherently-safe core physics, a nimble transient rod drive system, and a philosophy of continual facility improvement work together to enable flexible power maneuvers for fuel safety research. While the facility’s flexible design and multi-mission nature saw historic experiments for numerous transient types, TREAT was not specifically adapted to optimize or demonstrate its full performance capability for Light Water Reactor (LWR) postulated accidents including Hot Zero Power Reactivity Initiated Accidents (HZP-RIA) and Loss of Coolant Accidents (LOCA). The physics of HZP-RIA drive very brief pulses with fairly large energy excursions. TREAT is currently capable of approaching HZP-RIA pulse widths through transients initiated on a large step insertion of reactivity and terminated shortly thereafter by rapid re-insertion of the transient rods (“clipping”). LOCAs are postulated to occur quite differently, starting from normal power operations followed by a long period of lower power decay heat. TREAT is able to simulate LOCA events with an initial flattop transient for tens of seconds, followed by a sizeable power reduction, to a longer segment where specimen fission heating represents internal decay heat generation. Two reactor physics testing campaigns were undertaken to address the HZP-RIA type transients, neither of which had been performed in any great measure historically to address data gaps in the timing, repeatability of clipping and effect of dynamic transient rod motions on core-to-specimen fission power coupling. The first campaign, referred to as the Accident Tolerant Fuel (ATF) transient prescription tests, employed dosimeters in the core to characterize the effect of rod motions on specimen power coupling for clipped, unclipped, and low-level steady state operations each with approximately the same moderate core energy release. This campaign was accompanied by efforts to measure dosimetry and compare results to analytic predictions. The other HZP-RIA campaign, referred to as Narrow Pulse Width (NPW) transient prescriptions, employed higher step insertions with increased core energy release to demonstrate TREAT’s capability in achieving the narrowest-possible pulse width. Additionally, a series of LOCA transient prescriptions were also performed to demonstrate how well TREAT could perform long-duration shaped transients. Both NPW and LOCA transient prescriptions did not include dosimeters but used existing plant power instrumentation to produce transient power data. All three transient prescription campaigns were successfully carried out in TREAT. The ATF-3 transient prescriptions showed that TREAT can perform clipped transients with remarkable repeatability. Measurement and modeling both showed that the power coupling in small, fissile dosimeters does not change by more than 8% between clipped, unclipped, and steady state runs while uncertainty sources in both the modeling and measurement methods were identified and found to be on the order of 20% in total. Overall, the ATF-3 transient prescription tests were successful in determining repeatability and consistency of dosimeter power coupling, developing processes for modeling and measuring this crucial parameter, and demonstrating the need for continued efforts in transient prescription work at TREAT in support of future experiment design and post test data interpretation. The NPW and LOCA transient prescriptions were also successfully performed to exhibit TREAT’s capability for these important LWR accident categories. The NPW transients showed pulse widths of ~90 ms, which were the narrowest ever achieved in TREAT to date and relevant for the upper end range of HZP-RIA simulation. This effort provided crucial data for calibrating kinetic models to be used in enhanced pulse-narrowing strategies in upcoming irradiations. Similarly, The LOCA transient prescriptions showed that TREAT can simulate the needed nuclear heating and event time scales for LOCA fuel safety research and provided essential data for future experiment design.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Relativistic Coulomb screening in pulsational pair instability supernovae

Pulsational pair-instability supernovae (PPISNe) and pair instability supernovae (PISNe) are the result of a thermonuclear runaway in the presence of a background electron-positron pair plasma. As such, their evolution and resultant black hole masses could possibly be affected by screening corrections due to the electron pair plasma. The sensitivity of PISNe and PPISNe to relativistic weak screening has been explored. In this paper a weak screening model that includes effects from relativistic pair production has been developed and applied at temperatures approaching and exceeding the threshold for pair production. This screening model replaces “classical” screening commonly used in astrophysics. Modifications to the weak screening electron Debye length were incorporated in a computationally tractable analytic form. In PPISNe the BH masses were found to increase somewhat at high temperatures, though this increase is small. The BH collapse is also found to occur at earlier times, and the pulsational morphology also changes. In addition to the resultant BH mass, the sensitivity to the screening model of the pulsational period, the pulse structure, the PPISN-to-PISN transition, and the shift in the BH mass gap has been analyzed. The dependence of the composition of the ejected mass was also examined.

79 ASTRONOMY AND ASTROPHYSICS↗

Terahertz multiheterodyne spectroscopy using laser frequency combs

The terahertz region is of great importance for spectroscopy since many molecules have absorption fingerprints there. Frequency combs based on terahertz quantum cascade lasers feature broadband coverage and high output powers in a compact package, making them an attractive option for broadband spectroscopy. Here, we demonstrate the first multiheterodyne spectroscopy using two terahertz quantum cascade laser combs. Over a spectral range of 250 GHz, we achieve average signal-to-noise ratios of 34 dB using cryogenic detectors and 24 dB using room-temperature detectors, all in just 100 μs. As a proof of principle, we use these combs to measure the broadband transmission spectrum of etalon samples and show that, with proper signal processing, it is possible to extend the multiheterodyne spectroscopy to quantum cascade laser combs operating in pulsed mode. As a result, this greatly expands the range of quantum cascade lasers that could be suitable for these techniques and allows for the creation of completely solid-state terahertz laser spectrometers.

42 ENGINEERING↗

Improved neutron-gamma discrimination for a 3 He neutron detector using subspace learning methods

3 He gas based neutron linear-position-sensitive detectors (LPSDs) have been applied for many neutron scattering instruments. Traditional Pulse-Height Analysis (PHA) for Neutron-Gamma Discrimination (NGD) resulted in the neutron-gamma efficiency ratio on the orders of 10 5 -10 6 . The NGD ratios of 3 He detectors need to be improved for even better scientific results from neutron scattering. Digital Signal Processing (DSP) analyses of waveforms were proposed for obtaining better NGD ratios, based on features extracted from rise-time, pulse amplitude, charge integration, a simplified Wiener filter, and the cross-correlation between individual and template waveforms of neutron and gamma events. Fisher linear discriminant analysis (FLDA) and three multivariate analyses (MVAs) of the features were performed. The NGD ratios are improved by about 10 2 -10 3 times compared with the traditional PHA method. Finally, our results indicate the NGD capabilities of 3 He tube detectors can be significantly improved with subspace-learning based methods, which may result in a reduced data-collection time and better data quality for further data reduction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulating gas-filled neutron detector responses with DRiFT

– Gas-filled neutron detectors have numerous applications across the nuclear engineering and nuclear physics fields. The ability to accurately model and simulate these detectors is important for those applications but is currently limited by the lack of readily-useable detector response software. Recently, the capabilities of DRiFT, a Detector Response Function Toolkit, were expanded to model gas-filled, He-3 and BF3, neutron detectors so that, combined with the radiation transport capabilities of the MCNP code, a high-fidelity treatment of gas-filled neutron detectors can be obtained. Further, this model has been validated by an experiment carried out with the Epithermal Neutron Multiplicity Counter and its capabilities have been demonstrated in two additional experiments. This work shows that utilizing DRiFT to post-process MCNP outputs produces more accurate results than using the MCNP code alone, reducing the difference between experimental and simulated results for measurements taken near the end of a He-3 tube, where the MCNP code struggles to model inactive regions of the detector, from a maximum of 35% with the MCNP code alone to 15% with the MCNP code plus DRiFT. DRiFT's diagnostic capabilities are also demonstrated with measurements for scenarios when pulse pileup or room return effects are significant and must be considered. Altogether, these measurements underpin the ability of DRiFT to accurately model and predict the behavior of gas-filled neutron detectors, making it a valuable tool for the design and testing of systems and experiments that utilize these detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies of a proton phase beam monitor for range verification in proton therapy

A primary subject of the present research in particle therapy is to ensure the precise irradiation of the target volume. The prompt gamma timing (PGT) method provides one possibility for in vivo range verification during the irradiation of patients. Prompt gamma rays with high energies are emitted promptly due to nuclear reactions of protons with tissue. The arrival time of these gammas to the detector reflects the stopping process of the primary protons in tissue and are directly correlated to the range. Due to the time resolution of the detector and the proton bunch time spread, as well as drifts of the bunch phase with respect to the accelerator frequency, timing spectra are smeared out and compromise the accuracy of range information intended for future clinical applications. Nevertheless, counteracting this limitation and recovering range information from the PGT measured spectra, corrections using a phase beam monitor can be performed. A first prototype of phase beam monitor was tested at GSI Darmstadt, where measurements of the energy profile of the ion bunches were performed. At the ELBE accelerator Helmholtz-Zentrum Dresden-Rossendorf (HZDR), set up to provide bremsstrahlung photons in very short pulses, a constant fraction algorithm for the incoming digital signals was evaluated, which is used for optimizing the time resolution. Studies of scattering experiments with different thin targets and detector positions are accomplished at Oncoray Dresden, where a clinical proton beam is available. These experiments allow a basic characterization of the proton bunch structure and the detection yield. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Propagation dynamics of femtosecond pulse through subwavelength metallic hole arrays

We have studied the frequency-dependent transmission time delay of femtosecond (fs) laser pulses through subwavelength hole arrays in aluminum films using the up-conversion technique. The pulse delays measured at different wavelengths mainly follow the far-field transmission profile of the surface-plasmon polariton (SPP) resonances. Temporal delays of 60 and 100 fs were found at the major SPP resonance in the single-layer and double-layer samples. A coupled-SPP transmission model is used to explain the temporal dynamics of the transmission process. Our experiment shows that the weak coupling between the SPP waves on different metal-dielectric interfaces leads to the large temporal delay of the transmitted pulses.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Organic Scintillator Detector Response Simulations with DRiFT

Accurate detector modeling is a requirement to design systems in many non-proliferation scenarios; by determining a Detector’s Response Function (DRF) to incident radiation, it is possible characterize measurements of unknown sources. DRiFT is intended to post-process MCNP® output and create realistic detector spectra. Capabilities currently under development include the simulation of semiconductor, gas, and (as is discussed in this work) scintillator detector physics. Energy spectra and pulse shape discrimination (PSD) trends for incident photon and neutron radiation have been reproduced by DRiFT.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modified Purex first-cycle extraction for neptunium recovery

A new PUREX first-cycle flowsheet was devised to enhance the extraction yield of neptunium at the extraction step of this cycle. Simulation results (using a qualified process-simulation tool), le d to raising the nitric acid concentration of the feed from 3 M to 4.5 M to allow extraction of more than 99% of the neptunium. This flowsheet was operated in the shielded process cell of ATALANTE facility using pulsed columns and mixer-settlers banks. A 15 kg quantity of genuine oxide fuel of average burn up of 52 GWd/t with cooling time of nearly five years was treated, and the neptunium extraction yield obtained was greater than 99.6%. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Studies of a Proton Bunch Phase Monitor for Range Verification in Proton Therapy

A primary subject of the present research in particle therapy is to ensure the precise irradiation of the target volume. The prompt gamma timing (PGT) method provides one possibility for in vivo range verification during the irradiation of patients. Prompt gamma rays with high energies are emitted promptly due to nuclear reactions of protons with tissue. The arrival time of these gammas to the detector reflects the stopping process of the primary protons in tissue and is directly correlated to the range. Due to the time resolution of the detector and the proton bunch time spread, as well as drifts of the bunch phase with respect to the accelerator frequency, timing spectra are smeared out and compromise the accuracy of range information intended for future clinical applications. Nevertheless, counteracting this limitation and recovering range information from the PGT measured spectra, corrections using a bunch phase monitor can be performed. A first prototype of bunch phase monitor was tested at GSI Darmstadt, where measurements of the energy correlation profile of the ion bunches were performed. At the ELBE accelerator at Helmholtz-Zentrum Dresden-Rossendorf (HZDR), set up to provide bremsstrahlung photons in very short pulses, a constant fraction algorithm for the incoming digital signals was evaluated, which is used for optimizing the time resolution. Studies of scattering experiments with different thin targets and detector positions are accomplished at Onco Ray Dresden, where a clinical proton beam is available. These experiments allow a basic characterization of the proton bunch structure and the detection yield. (authors)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurement of Photoneutrons from Depleted Uranium and Comparison Study Using MCNPX-PoliMi

High-energy photon interrogation is a nondestructive technique that is used to detect special nuclear materials and characterize nuclear waste. The development of such systems is complex and requires Monte Carlo simulations to optimize system performance. Monte Carlo simulations rely on various scattering, absorption, and photonuclear cross-section data. While the scattering and absorption cross-section data have been extensively studied and validated with experiments, the results obtained from photonuclear simulations are often found to underpredict measured results, indicating uncertainties in the photonuclear cross sections themselves. Thus, there is a need for new measured results that can be used to quantify underpredictions in simulations using photonuclear cross-section data. In the present work, we interrogated depleted uranium with a 9-MV electron linac and detected photoneutrons with trans-stilbene organic scintillators. The measurement of photoneutrons with organic scintillators is challenging due to the presence of the intense photon flux, which causes issues such as pulse pile-up, detector saturation, and poor signal-to-background ratio. To mitigate these challenges, we used iron and polyethylene shielding of varying thicknesses around the depleted uranium target and a neural network–based digital pulse processing algorithm to recover neutron and photon information from piled-up events. Our goal was to compare the measured photoneutron count rate with the simulated rate obtained using the MCNPX-PoliMi transport code. For a light output window of 0.28 to 2.67 MeVee (1.66- to 6.85-MeV proton recoil energy), we found that the simulated count rate obtained using the ENDF/B-VII photonuclear cross-section library underpredicts the measured rate by 32.8% 3.2%. Additionally, we compared the simulated and measured photoneutron light output distributions. For the least thicknesses of shielding, the simulation was found to underpredict measurements in the 0.70- to 2.67-MeVee light output window. For the greatest thicknesses of shielding, the simulation was found to underpredict the measurement across the entire light output window of 0.28 to 2.67 MeVee.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Structural Studies of Alloyed and Nanoparticle Transition Metal Dichalcogenides by Selenium-77 Solid-State Nuclear Magnetic Resonance Spectroscopy

Layered transition metal dichalcogenides (TMDCs) such as MoS 2 , MoSe 2 , and WSe 2 are under intense investigation because they are atomically thin semiconductors with photophysical properties that can be tuned by changing their composition or morphology. Mechanochemical processing has been proposed as a method to obtain alloyed TMDCs in the series Mo 1–x W x S y Se 2–y (x = 0–1; y = 0–2). However, elucidating the chemical transformations occurring at the atomic scale following mechanochemical processing can be challenging because the products are often amorphous or microcrystalline. To address this challenge, we probe TMDC mixing and alloying by using a combination of powder X-ray diffraction, Raman spectroscopy, diffuse reflectance spectroscopy, 77 Se solid-state nuclear magnetic resonance (SSNMR) spectroscopy, and planewave density functional theory (DFT) calculations. The nature of the milling material and reaction atmosphere are shown to be essential factors in limiting the formation of undesired oxide byproducts. We demonstrate acquisition of 77 Se SSNMR spectra using different combinations of Carr-Purcell Meiboom-Gill acquisition (CPMG) pulse sequences, magic angle spinning (MAS), and MAS dynamic nuclear polarization. Further, the combination of SSNMR with the other characterization methods clearly demonstrates that high energy impact ball milling induces molecular level alloying of Mo, W and chalcogen atoms in the family Mo 1–x W x S y Se 2–y . Gauge including projector augmented wave DFT calculations yield accurate 77 Se chemical shift (CS) tensor components. 77 Se SSNMR spectroscopy was also applied to study the structure of WSe 2 nanocrystals intercalated with ethylenediamine. The intercalated WSe 2 nanocrystals exhibit a more positive isotropic 77 Se CS as compared to bulk WSe 2 , however, the 77 Se CS anisotropy is the same, confirming the WSe 2 layers have a similar structure as in their bulk counterparts.

36 MATERIALS SCIENCE↗