Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “modern grid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Cybersecurity Value-at-Risk Framework: Preprint

As more variable renewable energy sources are added to the grid, the critical role of hydropower as a reliable baseline and firming resource is rapidly growing. However, the U.S hydropower fleet is not fully prepared to face modern issues such as cybersecurity threats. Hydropower accounts for 37% of U.S. utility-scale renewable electricity but is challenged by diverse infrastructure and legacy devices that predate modern security practices. While new cybersecurity solutions cannot simply be added to current hydropower generation and operation technologies, custom cybersecurity assessments can reveal system-specific threats and risk probabilities and identify mitigating enhancements.

cybersecurity valuation↗

Energy storage emerging: A perspective from the Joint Center for Energy Storage Research

Energy storage is an integral part of modern society. A contemporary example is the lithium (Li)-ion battery, which enabled the launch of the personal electronics revolution in 1991 and the first commercial electric vehicles in 2010. Most recently, Li-ion batteries have expanded into the electricity grid to firm variable renewable generation, increasing the efficiency and effectiveness of transmission and distribution. Important applications continue to emerge including decarbonization of heavy-duty vehicles, rail, maritime shipping, and aviation and the growth of renewable electricity and storage on the grid. This perspective compares energy storage needs and priorities in 2010 with those now and those emerging over the next few decades. The diversity of demands for energy storage requires a diversity of purpose-built batteries designed to meet disparate applications. Advances in the frontier of battery research to achieve transformative performance spanning energy and power density, capacity, charge/discharge times, cost, lifetime, and safety are highlighted, along with strategic research refinements made by the Joint Center for Energy Storage Research (JCESR) and the broader community to accommodate the changing storage needs and priorities. Innovative experimental tools with higher spatial and temporal resolution, in situ and operando characterization, first-principles simulation, high throughput computation, machine learning, and artificial intelligence work collectively to reveal the origins of the electrochemical phenomena that enable new means of energy storage. This knowledge allows a constructionist approach to materials, chemistries, and architectures, where each atom or molecule plays a prescribed role in realizing batteries with unique performance profiles suitable for emergent demands.

Trahey, Lynn↗

Distributed Grid-Sensing Service Layer: A System Architecture Blueprint

In this report, a scalable, decentralized, sensor-oriented communication blueprint is introduced. The proposed architecture has been specifically designed to support the mass deployment of sensors and also enable data consumers to access the underlying data streams using a distributed systems approach. With the proposed approach, sensors and data clients can be decoupled from the physical communication infrastructure and migrated into a modern, software-defined infrastructure ecosystem that can be configured to suit the end application’s requirements. In its current iteration, this blueprint defines the interactions, processes, and expected outcomes that each individual component within the architecture must support the overall ecosystem’s needs. Within this work, such an assembly of services is called the data bus; it represents the heart of the distributed grid sensing services architecture, a multiyear project that aims to design, implement, and test a reference sensor-data dissemination network that can support the needs of the extended grid state. We expect this blueprint to guide our future implementation efforts

24 POWER TRANSMISSION AND DISTRIBUTION↗

Artificial Intelligence-Driven Management of Sustainable Energy Resources: Visibility, Operation, and Control

The rapid global transition toward sustainable energy resources (SERs) is reshaping how modern power systems are observed, optimized, and controlled. While SERs have significantly advanced decarbonization, their weather dependence, variability, and inverter-dominated characteristics challenge traditional, centralized, and deterministic grid operation. At the same time, the proliferation of high-resolution data from inverters, smart meters, and sensors offers unprecedented visibility into system dynamics. Yet, it also exceeds the analytical capability of conventional model-based approaches. Artificial intelligence (AI) provides a new foundation for addressing these challenges by bridging physical laws with data-driven learning, enabling accurate state awareness, adaptive operation, and coordinated control across distributed assets. This article examines how AI transforms the management of SER-rich power systems along three critical dimensions: 1) enhancing visibility by inferring behind-the-meter (BTM) activities, assessing SER flexibility, and reconstructing system states from sparse or noisy measurements; 2) improving operation through AI-enhanced SER service provision, volt/var control (VVC), and dynamic operating envelopes (DOE) for efficiency and security; and 3) advancing control by embedding learning-based intelligence into inverter coordination, voltage and frequency regulation, and long-term dispatch. Together, these developments reveal how AI can convert the variability of SERs from an operational challenge into a source of flexibility, resilience, and intelligence, paving the way toward sustainable, adaptive, and self-optimizing power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SAM Finite Volume Method Development Status Update: GCR Application, Restart, and MultiApp

The System Analysis Module (SAM) is being developed as a modern system analysis code for advanced non-light-water-reactor safety analysis under the U.S. DOE NEAMS program. Previous feasibility studies have demonstrated that a staggered-grid finite volume method (SG-FVM), implemented under the MOOSE framework, can deliver more than an order of magnitude speedup over the existing continuous Galerkin finite element method (CG-FEM) solver for liquid-cooled, incompressible but thermally expandable flow systems. This work extends the previous effort to compressible, gas-cooled reactor applications, where pressure couples directly into the mass equation adding additional nonlinearity into the equation system. New code capabilities are implemented for pebble bed high-temperature gas-cooled reactor (PB-HTGR) analysis, including a pebble bed CoreChannel component, built-in pebble bed effective thermal conductivity model and channel-to-channel crossflow model. The capabilities are tested, benchmarked, and demonstrated for problems with increased level of model and physical complexities, including the HTTU effective thermal conductivity test, the SANA passive cooling test, and a demonstration case using the GPBR200 reactor design covering steady-state operation, DLOFC and PLOFC transients. Across all cases, the SG-FVM solver demonstrated strong robustness and efficiency, and the solutions agree well with reference results and data. The finding of this work proves that SG-FVM is a viable and efficient solver pathway for compressible, gas-cooled reactor system analysis in SAM. In addition, work has been done to successfully support SAM-FVM recover/restart code feature that is essential to reactor safety analysis applications, and MultiApp code feature that is essential to multi-scale and multi-physics simulations. In summary, this work continued from previous feasibility studies, and further demonstrated that the SG-FVM will serve as a strong foundation for SAM’s advanced solver algorithm for future deployment.

Zou, Ling↗

Comparative Study of Nonlinear Black-Box Modeling for Power Electronics Converters

With the increasing penetration level of renewable sources and power electronics loads in modern power systems, accurate and computationally efficient models are needed. Black-box model (BBM) could be a useful method in such systems. However, not very extensive research efforts have been made for power electronics BBM so far, and existing works mostly focus on steady-state operation, neglecting the important transient behaviors such as load transients, voltage transients, and faults. This paper presents a comparative study of three commonly used nonlinear BBM approaches for transient behaviors of power electronics converters. Comparison methods are proposed, and the evaluations are conducted under different transients using a grid-connected single-phase photovoltaic inverter. The findings of this study provide valuable references for further feasibility investigations on implementing BBMs in large-scale power electronics-rich power systems.

Qiao, Liang↗

Assessing the performance of global thermostat adjustment in commercial buildings for load shifting demand response

Abstract Efficiently leveraging new sources of flexibility is critical to mitigating load balancing challenges posed by variable renewable resources. The thermal inertia of commercial buildings allows us to shift their power consumption on minute to hourly timescales to provide demand response to the grid while maintaining occupant comfort. Global thermostat adjustment (GTA) provides a readily available and scalable approach for implementing load shifting demand response using commercial heating, ventilation, and air conditioning (HVAC) systems, since it leverages the inherent sophistication of modern building automation systems. However, there is an incomplete understanding of GTA’s performance for this purpose and its impact on building systems and occupant comfort. In this paper, we explore the performance of GTA by analyzing results from nearly nine hundred experiments on eight university campus buildings in Michigan and North Carolina. Using GTA, we manipulate each building’s thermostat setpoints causing the building to shift its power consumption with respect to its baseline. We quantify the magnitude of HVAC power response, energy use of HVAC subsystems, and impact on occupant comfort. Finally, we connect our experimental results with power system operation using an optimization model that coordinates GTA actions across a large collection of grid-interactive efficient buildings (GEBs) to reduce high ramp rates on the grid and mitigate renewable energy curtailment. Overall, our work finds that the impacts on HVAC subsystems are often complex, and may result in additional energy being consumed by fans and terminal reheat. These effects must be considered when using GTA for load shifting. Additionally, we demonstrate that occupant comfort, as assessed by indoor temperature and humidity, can be maintained during GTA events. From a societal perspective, our modeling work finds that the additional renewable energy that can be integrated through the use of GTA strategies eclipses any additional energy consumed by buildings.

Keskar, Aditya (ORCID:0000000244617980)↗

Deep Learning-Based Dynamic Modeling of Three-Phase Voltage Source Inverters

Inverter-based resource (IBR) models are necessary to analyze modern power system stability and create effective control strategies. Modeling IBRs in converter-rich power systems is crucial, yet challenging due to the lack of commercial information on converter topologies and control parameters. This paper proposes novel convolutional neural network (CNN)–based data-driven techniques for modeling IBRs, addressing adaptability and proprietary concerns without requiring internal system physics knowledge. The proposed method is tested using real grid-tied commercial IBR transient data and demonstrates effectiveness and accuracy. Furthermore, the developed modeling approach is integrated and implemented in the open-source power distribution simulation and analysis tool, GridLAB-D, to illustrate the potentiality of dynamic analysis of large-scale power systems with high IBRs.

deep learning, artificial intelligence↗

Impacts of Experimentally Obtained Harmonic Spectrums of Residential Appliances on Distribution Feeder

Owing to the increased use of power electronic based appliances and energy-efficient home equipment such as modern lighting loads, the percentage of nonlinear loads has increased in the distribution system, which can impact system performance, loss, and stability. Thus a comprehensive knowledge of their power quality and harmonic analysis is essential to improve the load models, voltage stability assessment, determination of possible interactions at harmonic frequencies, protection planning, and the effect of system impedance. This paper focuses on harmonic load flow analysis for multiple residential load types to determine the expected impacts on an modeled distribution secondary. For this study, the household appliances include lighting, power electronic, resistive, and motor loads with a nominal supply voltage of 120 V single-phase or 240 V split phase at a nominal frequency of 60 Hz. The harmonic spectrums, as obtained from the experimental evaluation of real loads, are used to inform the harmonic load flow for a detailed secondary network, including the distribution service transformer extracted from a real distribution feeder's model. Additionally, the impact of voltage harmonics on a three-phase test load is presented with experimental results. The harmonic data of the transformer terminal voltage, as obtained from the former load flow study, are scaled to generate the source voltage for the three-phase configuration of the grid simulator to make the test setup very similar to a typical secondary design in the U.S.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

The Distributed Grid Sensing Services (DGSS) platform: A scalable and decentralized sensor dissemination network

In this paper, a scalable, decentralized sensor-oriented, communication blueprint will be introduced. The proposed architecture has been specifically designed to support the mass deployment of sensors while enabling data consumers to access the underlying data streams using a distributed systems approach. With the proposed approach, sensors and data clients can be decoupled from the physical communication infrastructure and migrated into a modern, software-defined infrastructure ecosystem that can be configured to suit the end application’s demands. In its current iteration, the blueprint defines the interactions, processes, and expected outcomes that each individual component within the architecture must fulfill in order to support the overall ecosystem’s needs. Within this work, such assemble of services is referred the databus, and represents the heart of the Distributed Grid Sensing Services (DGSS) architecture, a multi-year project that aims to design, implement and test a dedicated sensor dissemination network that can support the needs of the extended grid state. It is our expectation, that the proposed blueprint presented in this paper will serve as a future guide to our implementation efforts

Sebastian Cardenas, David J.↗

Kinetic theory of particle-in-cell simulation plasma and the ensemble averaging technique

Abstract We derive the kinetic theory of fluctuations in physically and numerically stable particle-in-cell (PIC) simulations of electrostatic plasmas. The starting point is the single-time correlation at the start of the simulation between the statistical fluctuations of the weighted densities of macroparticle centers in the plasma particle phase-space. The fluctuations are associated with different initial conditions, typically due to the random initial conditions (in velocity space) of the macroparticles/simulation plasma, assigned according to their initial distribution of probability. The single-time correlations at all time steps and in each spatial grid cell are then determined from the Laplace–Fourier transforms of the discretized Klimontovich-like equation for the macroparticles and Maxwell’s equations for the fields, as computed by modern PIC codes. We recover the expressions for the electrostatic field and the plasma particle density fluctuation autocorrelation spectra as well as the kinetic equations describing the average evolution of PIC-simulated plasma particles, first derived by Langdon (1970b Proc. 4th Conf. Numerical Simulation of Plasmas ) using a test macroparticle approach perturbing a discretized Vlasovian plasma and then averaging the obtained physical quantity over the initial macroparticle velocity distribution. We generalize and extend these results to the modern algorithms in PIC codes using arbitrary macroparticle weights. Analytical estimates of statistical fluctuation amplitudes are derived as a function of the plasma simulation parameters, using the central limit theorem in the limit of a large number of macroparticles per cell. The theory is then used to analyze the ensemble averaging technique of PIC simulations where statistical averages are performed over ensembles of PIC simulations, modeling the same plasma physics problem but using different statistical realizations of the initial distribution functions of the macroparticles. This method is illustrated by linear Landau damping uncovering (from noise, which is usually considered numerical) the physical fluctuations driven by a single small amplitude electrostatic wave perturbing a PIC simulation plasma in equilibrium.

fluctuations correlations↗

Stability Analysis of Power Systems with High Penetration of State-of-the-Art Inverter Technologies

With the increasing level of inverter-based resources (IBRs) in modern power systems, this paper presents a small-signal stability analysis for power systems comprising synchronous generators (SGs) and IBRs. Four types of inverter controls are considered: two grid-following (GFL) controls, with or without grid support functions; droop-based grid-forming (GFM) controls; and virtual oscillator control-based GFM. We also analyze the impact of STATCOM and synchronous condensers on system stability to assess their role in the energy mix transition. With the small-signal dynamic behavior of the major technologies modeled, this paper provides stringent stability assessments using the IEEE 39-bus benchmark system modified to simulate future power systems. The exhaustive test cases allow for (a) assessing the impacts of different types and controls of generation and supplementary grid assets, as well as system inertia and line impedance on grid stability, and (b) elucidating pathways for the stabilization of IBR-dominated power systems. The analysis also indicates that future power systems can be stabilized with only a fraction of the total generation as voltage sources without SGs or significant system inertia if they are well distributed. This study provides insights into future power system operations with a high level of IBRs that can also be used for planning and operation studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Rapid Monitoring and Defense Approach for Resilience Improvement of Grid Cyber Security

Cyber-physical systems and electric utilities significantly depend on the reliability and efficiency of information and operational technology. However, false data injection attacks based on synchrophasor measurement data pose a serious threat to the safe and reliable operation of modern power systems. Here, to mitigate this problem, a rapid monitoring and defense approach is proposed to defend against cyber attacks. Initially, the Time and Frequency based Convolutional neural Network (TFCN) is proposed to detect different types of attacks. Within the TFCN, the advances are that both time and frequency domain information can be fused without extra spectrum analysis methods, and can save detection time to speed the calculation efficiency using the developed time-frequency block. Next, a comprehensive defense strategy is developed for multiple cyber attacks to ensure the stability and resilience of the power system according to the feedback detection results. The advances of this strategy are that different control strategies can be automatically selected to recover the stability to the greatest extent according to the detected attacks. To verify the effectiveness of the proposed approach, the high-speed frequency measurements collected from the wide-area monitoring system are used. The results demonstrate that the cyber attack detection performance can reach 95.57% accuracy, outperforming both traditional and some advanced neural networks. Importantly, the defense strategy is conducted and verified in a modified IEEE 39 bus system as well, which illustrates profound performance in faster stability restoration.

Comprehensive defense strategy↗

An Overview of Renewable Energy Desk Activities for Power Grid Operations and Planning

This document summarizes how grid operators can address gaps in their planning and operations to maintain reliability as they pursue clean energy goals. When transitioning to higher renewable energy levels, many system operators configure a dedicated renewable energy desk to manage variable renewable energy resource operation. Establishing such a desk in the control room can be a key step in the modernization effort. A renewable energy desk in a control room is a specialized hub focused solely on monitoring, predicting, and managing the influx of energy from renewable sources.

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗

Calculating Critical Inertia of a Power System

The increasing integration of renewable energy sources in modern power systems has led to a decline in system inertia, raising concerns about frequency stability following large disturbances. Determining critical inertia is essential to prevent excessive frequency decline and ensure grid stability. This paper evaluates four different methods for calculating critical inertia, using the Electric Reliability Council of Texas (ERCOT) system as a test case. The results highlight the importance of employing multiple methodologies to capture the full spectrum of inertia requirements.

Hakim sneha, Fariha [University of Tennessee, Knox↗

Demonstrating the Transient System Impact of Cyber-Physical Events Through Scalable Transmission and Distribution (T&D) Co-Simulation

Modern power systems become more vulnerable to cyber threats due to their growing interconnectivity, interdependence, and complexity. Widespread deployment of distributed energy resources (DERs) further expands the threat landscape to the grid edge, where fewer cybersecurity protections exist. In this article, a systematic cyber-physical events demonstration, enabled by an integrated transmission, distribution, and communication co-simulation framework, is performed. It analyzes cyber risks to power grid under DER-enabled automatic generation control from different angles. Unlike existing works, the simulation captures millisecond-to-minutes frequency and voltage transient dynamics at a cross-region system scale.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ExaWind: Open‐source CFD for hybrid‐RANS/LES geometry‐resolved wind turbine simulations in atmospheric flows

Abstract Predictive high‐fidelity modeling of wind turbines with computational fluid dynamics, wherein turbine geometry is resolved in an atmospheric boundary layer, is important to understanding complex flow accounting for design strategies and operational phenomena such as blade erosion, pitch‐control, stall/vortex‐induced vibrations, and aftermarket add‐ons. The biggest challenge with high‐fidelity modeling is the realization of numerical algorithms that can capture the relevant physics in detail through effective use of high‐performance computing. For modern supercomputers, that means relying on GPUs for acceleration. In this paper, we present ExaWind, a GPU‐enabled open‐source incompressible‐flow hybrid‐computational fluid dynamics framework, comprising the near‐body unstructured grid solver Nalu‐Wind, and the off‐body block‐structured‐grid solver AMR‐Wind, which are coupled using the Topology Independent Overset Grid Assembler. Turbine simulations employ either a pure Reynolds‐averaged Navier–Stokes turbulence model or hybrid turbulence modeling wherein Reynolds‐averaged Navier–Stokes is used for near‐body flow and large eddy simulation is used for off‐body flow. Being two‐way coupled through overset grids, the two solvers enable simulation of flows across a huge range of length scales, for example, 10 orders of magnitude going from O(μm) boundary layers along the blades to O(10 km) across a wind farm. In this paper, we describe the numerical algorithms for geometry‐resolved turbine simulations in atmospheric boundary layers using ExaWind. We present verification studies using canonical flow problems. Validation studies are presented using megawatt‐scale turbines established in literature. Additionally presented are demonstration simulations of a small wind farm under atmospheric inflow with different stability states.

17 WIND ENERGY↗

An Operational Resilience Metric to Evaluate Inertia and Inverter-based Generation on the Grid

In an effort to reduce carbon emissions and curtail the effects of climate change there has been considerable effort to increase the penetration of inverter-based renewable energy sources. The adoption of renewable generation over conventional inertia-based generation sources is forming considerable challenges for the operation and stability of the power system. The power system has been designed around generation units characterized by high inertia and primary frequency response (PFR), allowing them to respond to disturbances such as faults or generators tripping off line. In contrast, the modern inverter-based assets are characterized by no contribution to inertia and they typically provide stochastic generation at their maximum output, thus having no contribution to PFR during low-frequency disturbance events. Because of this, inertia in power systems is reducing, resulting in a faster rate of frequency change after a disturbance occurs. As more inverter-based generation units are added to the grid it is important to understand the stability of the system and the size of disturbance a system is capable of withstanding. This paper presents a resilience metric that evaluates the maximum size of disturbance a systems can withstand based on the system inertia and the primary frequency control of inverter and inertia-based generation. The results are shown visually and are based on the real-time operation of generation units and their characteristics such as latency, ramp rates, and energy constraints. It is demonstrated that the real-time positioning or bias of the generating units has an effect of the size of disturbance that a system can withstand, i.e. its resilience. It is expected that this type of analysis can help operators increase the resilience of power systems in the future.

13 HYDRO ENERGY↗