Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “material flows”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Simulations of Hayabusa2 Atmospheric Entry and Comparisons with Data from the Imaging Campaign

Results from flow and radiation simulations for the Hayabusa2 Sample Return Capsule (SRC) along its best-estimated trajectory (BET) are presented. Flow fields are first computed at several points along the best-estimated trajectory for a freestream consisting of N2, O2, Ar, CO2, and H2O; the last three are trace species in Earth’s atmosphere. The thermal response of an assumed ablative material is estimated and flow fields are recomputed at each time point with modified surface temperature distributions. The spectral radiance, from the combination of an aeroheated capsule and the high-temperature shock layer around it, is computed on an imaging plane for a given view angle and slant range at each time point. The radiance is transported through the intervening atmosphere between the Hayabusa2 SRC and the observing aircraft and upon integration over solid angle representing the field of view of the instruments converted to a spectral irradiance. The spectral irradiance is convolved with the instrument function to obtain results that can be directly compared with measurement. Fair to good comparisons with measurements required shifting the time coordinate of measurements by 7.5 s. The disagreement between prediction and measurement is substantial after about 72.5 s along the BET. Additional computations seem to support the idea of flow transition over the capsule.

Atmospheric entry↗

Simulations of Hayabusa2 Atmospheric Entry and Comparisons with Data from the Imaging Campaign

Results from flow and radiation simulations for the Hayabusa2 Sample Return Capsule (SRC) along its best-estimated trajectory (BET) are presented. Flow fields are first computed at several points along the best-estimated trajectory for a freestream consisting of N2, O2, Ar, CO2, and H2O; the last three are trace species in Earth’s atmosphere. The thermal response of an assumed ablative material is estimated and flow fields are recomputed at each time point with modified surface temperature distributions. The spectral radiance, from the combination of an aeroheated capsule and the high-temperature shock layer around it, is computed on an imaging plane for a given view angle and slant range at each time point. The radiance is transported through the intervening atmosphere between the Hayabusa2 SRC and the observing aircraft and upon integration over solid angle representing the field of view of the instruments converted to a spectral irradiance. The spectral irradiance is convolved with the instrument function to obtain results that can be directly compared with measurement. Fair to good comparisons with measurements required shifting the time coordinate of measurements by 7.5 s. The disagreement between prediction and measurement is substantial after about 72.5 s along the BET. Additional computations seem to support the idea of flow transition over the capsule.

Atmospheric entry↗

Heat Transfer Through Turbulent Friction Layers

The "general Prandtl number" Pr(exp 1) - A(sub q)/A Pr, aside from the Reynolds number determines the ratio of turbulent to molecular heat transfer, and the temperature distribution in turbulent friction layers. A(sub q) = exchange coefficient for heat; A = exchange coefficient for momentum transfer. A formula is derived from the equation defining the general Prandtl number which describes the temperature as a function of the velocity. For fully developed thermal boundary layers all questions relating to heat transfer to and from incompressible fluids can be treated in a simple manner if the ratio of the turbulent shear stress to the total stress T(sub t)/T in the layers near the wall is known, and if the A(sub q)/A can be regarded as independent of the distance from the wall. The velocity distribution across a flat smooth channel and deep into the laminar sublayer was measured for isothermal flow to establish the shear stress ratio T(sub t)/T and to extend the universal wall friction law. The values of T(sub t)/T which resulted from these measurements can be approximately represented by a linear function of the velocity in the laminar-turbulent transition zone. The effect of the temperature relationship of the material values on the flow near the wall is briefly analyzed. It was found that the velocity at the laminar boundary (in contrast to the thickness of the laminar layer) is approximately independent of the temperature distribution. The temperature gradient at the wall and the distribution of temperature and heat flow in the turbulent friction layers were calculated on the basis of the data under two equations. The derived formulas and the figures reveal the effects of the Prandtl number, the Reynolds number, the exchange quantities and the temperature relationship of the material values.

Reichardt, H.↗

Studies with the USF/NASA toxicity screening test method - Effect of air flow and effect of fabric dye

One sample each of commercial polyurethane and polychloroprene flexible foams were evaluated using the USF/NASA toxicity screening test method. Air flow rates of 0, 0.16, 16, and 48 ml/sec were used to determine the effect of air flow on relative toxicity. Time to first sign of incapacitation and time to death were substantially reduced with both polyurethane and polychloroprene flexible foams by the introduction of 16 to 48 ml/sec air flow. The relative toxicity rankings of these materials were not altered by changes in air flow. Under these test conditions, the polyurethane foam consistently appeared more toxic than the polychloroprene foam. Samples of six different colors from the same fabric were evaluated separately, using the USF/NASA toxicity screening test method, to determine the effect of fabric dye, if any. The material was an upholstery fabric, consisting of 46 percent cotton, 33 percent wool, and 21 percent nylon. There appeared to be no significant effect of fabric dye on relative toxicity, for this material under these test conditions.

Hilado, C. J.↗

Preparation for microgravity - The role of the Microgravity Material Science Laboratory

Experiments at the NASA Lewis Research Center's Microgravity Material Science Laboratory using physical and mathematical models to delineate the effects of gravity on processes of scientific and commercial interest are discussed. Where possible, transparent model systems are used to visually track convection, settling, crystal growth, phase separation, agglomeration, vapor transport, diffusive flow, and polymer reactions. Materials studied include metals, alloys, salts, glasses, ceramics, and polymers. Specific technologies discussed include the General Purpose furnace used in the study of metals and crystal growth, the isothermal dendrite growth apparatus, the electromagnetic levitator/instrumented drop tube, the high temperature directional solidification furnace, the ceramics and polymer laboratories and the center's computing facilities.

Johnston, J. Christopher↗

Characterization of a Laminate Flat Plate Diffusion Flame in Microgravity using PIV, Visible and CH Emissions

Motivated by fire safety concerns and the advent of long-term micro-gravity facilities, a cooperative program has been developed to study the mechanisms and material properties that control flow assisted (co-current) flame spread. This program has used as a common fire scenario a reacting steady-state boundary layer. Preliminary studies explored the aerodynamics of a reacting boundary layer by simulating a condensed fuel by means of a gas burner. Stability curves for ethane air flames were obtained and different burning regimes were identified. An important feature of this study was the independent identification of the different mechanisms leading to the instability of the flow. It was observed that fuel injection velocity and thermal expansion independently contributed to the separation of the flow at the leading edge of the burner. The occurrence of separation resulted in complex three-dimensional flow patterns that have a dominant effect on critical fire safety parameters such as the stand-off distance and flame length. This work was extended to a solid fuel (PMMA) leading to a Sounding Rocket experiment (Mini-Texus-6). The solid phase showed similar flow patterns, mostly present at low flow velocities (<100 mm/s) but the results clearly demonstrated that the thermal balance at the pyrolyzing fuel surface is the dominant mechanism that controls both stand-off distance and flame length. This thermal balance could be described in a global manner by means of a total mass transfer or "B" number. This "B" number incorporates surface re-radiation, radiative feedback and in-depth heat conduction as first prescribed by Emmons. The mass transfer number becomes the single parameter that determines the evolution of these fire safety variables (flame length, stand-off distance) and therefore can be used as a ranking criterion to assess the flammability of materials. The particular configuration is representative of the NASA upward flame spread test (Test 1) therefore this approach can be used in the interpretation of the results obtained from this test. Nevertheless, complete validation of this approach has not been fully achieved due, mainly because all the measurements necessary to compare with the theoretical predictions have not been obtained. Following these studies two different directions have been taken. The first attempts to elucidate the details of the gas phase combustion reaction and the associated flow field by means of quantitative and qualitative measurements. The second approach, a more practical one, is to apply this methodology to the assessment of material flammability. The former is currently being conducted with a gas burner because it allows for easier control and longer experimentation time. The results obtained so far will be presented in more detail. The latter is a new program therefore only a brief summary of the objectives will be presented.

Joulain, P.↗

Effect of Non-Equilibrium Surface Thermochemistry in Simulation of Carbon Based Ablators

This study demonstrates that coupling of a material thermal response code and a flow solver using non-equilibrium gas/surface interaction model provides time-accurate solutions for the multidimensional ablation of carbon based charring ablators. The material thermal response code used in this study is the Two-dimensional Implicit Thermal-response and AblatioN Program (TITAN), which predicts charring material thermal response and shape change on hypersonic space vehicles. Its governing equations include total energy balance, pyrolysis gas mass conservation, and a three-component decomposition model. The flow code solves the reacting Navier-Stokes equations using Data Parallel Line Relaxation (DPLR) method. Loose coupling between the material response and flow codes is performed by solving the surface mass balance in DPLR and the surface energy balance in TITAN. Thus, the material surface recession is predicted by finite-rate gas/surface interaction boundary conditions implemented in DPLR, and the surface temperature and pyrolysis gas injection rate are computed in TITAN. Two sets of nonequilibrium gas/surface interaction chemistry between air and the carbon surface developed by Park and Zhluktov, respectively, are studied. Coupled fluid-material response analyses of stagnation tests conducted in NASA Ames Research Center arc-jet facilities are considered. The ablating material used in these arc-jet tests was Phenolic Impregnated Carbon Ablator (PICA). Computational predictions of in-depth material thermal response and surface recession are compared with the experimental measurements for stagnation cold wall heat flux ranging from 107 to 1100 Watts per square centimeter.

Chen, Yih-Kanq↗

Galileo Heat Shield Response Experiment Data Reduction and Analyses

The Galileo heat shield response experiment consists of 10 Analog Resistance Ablation Detectors (ARADs) embedded in the carbon phenolic heat shield. As the vehicle descends into the atmosphere of Jupiter, these ARADs will in effect measure the recession as a function of time at various locations on the heat shield. This recession data will be used to reconstruct the time-dependent shape of the vehicle. The shape data is of critical importance to the Atmospheric Reconstruction Experiment which must know mass and drag coefficient of the vehicle in order to determine the structure of the Jovian atmosphere. The data is also intrinsically useful as a database for evaluating the accuracy of our numerical codes and methodology for predicting highly radiating reentry flowfields and coupled heat shield material response. This paper will document the reduction of the data from the ARAD sensors, reconstruction of the heat shield shape history, and comparison of the actual heat shield response with previous calculations and experiments. If possible, we will also include results from new calculations which couple the shock layer flow with the transient material response.

Milos, Frank S.↗

Human life support during interplanetary travel and domicile. II - Generic Modular Flow Schematic modeling

This paper describes the Generic Modular Flow Schematic (GMFS) architecture capable of encompassing all functional elements of a physical/chemical life support system (LSS). The GMFS can be implemented to synthesize, model, analyze, and quantitatively compare many configurations of LSSs, from a simple, completely open-loop to a very complex closed-loop. The GMFS model is coded in ASPEN, a state-of-the-art chemical process simulation program, to accurately compute the material, heat, and power flow quantities for every stream in each of the subsystem functional elements (SFEs) in the chosen configuration of a life support system. The GMFS approach integrates the various SFEs and subsystems in a hierarchical and modular fashion facilitating rapid substitutions and reconfiguration of a life support system. The comprehensive ASPEN material and energy balance output is transferred to a systems and technology assessment spreadsheet for rigorous system analysis and trade studies.

Farral, Joseph F.↗

Complementary Barrier Infrared Detector

The complementary barrier infrared detector (CBIRD) is designed to eliminate the major dark current sources in the superlattice infrared detector. The concept can also be applied to bulk semiconductor- based infrared detectors. CBIRD uses two different types of specially designed barriers: an electron barrier that blocks electrons but not holes, and a hole barrier that blocks holes but not electrons. The CBIRD structure consists of an n-contact, a hole barrier, an absorber, an electron barrier, and a p-contact. The barriers are placed at the contact-absorber junctions where, in a conventional p-i-n detector structure, there normally are depletion regions that produce generation-recombination (GR) dark currents due to Shockley-Read- Hall (SRH) processes. The wider-bandgap complementary barriers suppress G-R dark current. The barriers also block diffusion dark currents generated in the diffusion wings in the neutral regions. In addition, the wider gap barriers serve to reduce tunneling dark currents. In the case of a superlattice-based absorber, the superlattice itself can be designed to suppress dark currents due to Auger processes. At the same time, the barriers actually help to enhance the collection of photo-generated carriers by deflecting the photo-carriers that are diffusing in the wrong direction (i.e., away from collectors) and redirecting them toward the collecting contacts. The contact layers are made from materials with narrower bandgaps than the barriers. This allows good ohmic contacts to be made, resulting in lower contact resistances. Previously, THALES Research and Technology (France) demonstrated detectors with bulk InAsSb (specifically InAs0.91Sb0.09) absorber lattice-matched to GaSb substrates. The absorber is surrounded by two wider bandgap layers designed to minimize impedance to photocurrent flow. The wide bandgap materials also serve as contacts. The cutoff wavelength of the InAsSb absorber is fixed. CBIRD may be considered as a modified version of the THALES double heterostructure (DH) p-i-n device, but with even wider bandgap barriers inserted at the contact layer/absorber layer interfaces. It is designed to work with either bulk semiconductors or superlattices as the absorber material. The superlattice bandgap can be adjusted to match the desired absorption cutoff wavelength. This infrared detector has the potential of high-sensitivity operation at higher operating temperatures. This would reduce cooling requirements, thereby reducing the power, mass, and volume of the equipment and allowing an increased mission science return.

Ting, David Z.↗

Flow through a wire-form transpiration-cooled vane

Results of recent research to develop techniques for analyzing coolant flow in transpiration-cooled vanes are summarized. Flow characteristics of the wire-form porous material are correlated; the effects on the flow characteristics of oxidation, coolant temperature, gas crossflow, and airfoil curvature are evaluated. An analytical method is presented for predicting coolant flows and pressures in a strut-supported vane.

Kaufman, A. S.↗

Zero-leakage valves

Valve action confines polymeric material in a metal groove effecting seal by compressive reaction of the polymer. As cold flow does not occur, sealing material resiliency is preserved over numerous operations.

Salvinski, R. J.↗

FTIR Study of Vapor Offgassing from Orbiter Tile Re-Waterproofing Materials

The work presented in this paper was performed to identify and quantify the offgassing behavior of alternative re-waterproofmg materials under investigation for application to Shuttle Orbiter Thermal Protection System (TPS) tile and blanket materials. The purpose was to determine whether the new materials would cause a problem with the operational analysis of residual vapors using the current portable vapor analyzer, a Miran 203. The materials investigated were limited to dimethylethoxysilane (DMES) and proposed solvent selected as suitable for use in re-waterproofing Orbiter TPS. The solvent was selected in another phase of the overall project. Obiter TPS tiles were injected with the re-waterproofing materials under constant conditions of temperature, relative humidity and air flow. The vapor concentrations of offgassing materials were monitored using Fourier Transform Infrared (FTIR) multi-component analysis, and with the Miran 203 instruments. The procedure was to record the time dependent concentrations of offgassing materials as analyzed by the FTIR, and the time response of the Miran 203 to the materials under consideration. The FTIR was calibrated for vapor phase DMES, tetramethyldisiloxane (TMDS), ethanol and the hydrocarbon solvents to be used to dilute the DMES for application to the TPS tile. The Miran 203 was calibrated for the operational measurement of DMES airborne vapors. The FTIR data, shows for the first time that the principal product which offgases from the tile after the first hour is not DMES, but TMDS and ethanol. The Miran 203 response to TMDS is the primary reading after the re-waterproofing operation is completed. The operational use of the Miran 203 to measure DMES vapors after re-waterproofmg operations has been responding to TMDS. The results of this study suggest that the historical complaints that have contributed to the low threshold limit value (TLV) for DMES concentrations, as read with the Miran 203, are actually based on instrumental responses to TMDS, for which no other toxicology information is available at this time. While there is some interference, the use of the tested hydrocarbon solvents does not adversely affect the response of the Miran 203.

Mattson, C. B.↗

Wind Tunnel Visualization of the Flow Over a Full-Scale F/A-18 Aircraft

The proposed paper presents flow visualization performed during experiments conducted on a full-scale F/A-18 aircraft in the 80- by 120-Foot Wind-Tunnel at NASA Ames Research Center. This investigation used both surface and off-surface flow visualization techniques to examine the flow field on the forebody, canopy, leading edge extensions (LEXs), and wings. The various techniques used to visualize the flow field were fluorescent tufts, flow cones treated with reflective material, smoke in combination with a laser light sheet, and a video imaging system. The flow visualization experiments were conducted over an angle of attack range from 20deg to 45deg and over a sideslip range from -10deg to 10deg. The results show regions of attached and separated flow on the forebody, canopy, and wings. Additionally, the vortical flow is clearly visible over the leading-edge extensions, canopy, and wings.

Lanser, Wendy R.↗

Two phase flow and heat transfer in porous beds under variable body forces, part 2

Analytical and experimental investigations of a pilot model of a channel for the study of two-phase flow under low or zero gravity are presented. The formulation of dimensionless parameters to indicate the relative magnitude of the effects of capillarity, gravity, pressure gradient, viscosity, and inertia is described. The investigation is based on the principal equations of fluid mechanics and thermodynamics. Techniques were investigated by using a laser velocimeter for measuring point velocities of the fluid within the porous material without disturbing the flow.

Evers, J. L.↗

The 1950 sulfur flow of Mauna Loa: Considerations for Io

Some of the geological relationships observed in the Mauna Loa sulfur flow may apply in considering volcanic processes on Io. Given the presence of sulfur/sulfur compounds in the eruption plumes and on the surface of Io, it is likely that extensive secondary deposits of sulfur exist, some of which may be of fumarolic origin and analogous to the Mauna Loa deposit. Given the likelihood of silicate volcanism of Io based on the inferred material properties of some flows, and the attendant high temperatures for silicate volcanism, it is likely that the secondary surface deposits of sulfur would have been mobilized without being heated to the high viscosity stage. Mobilized sulfur flows on Io may flow long distances as a result of: (1) low viscosities in the melting range; (2) sustained effusion resulting from continued heating source area; (3) continued remobilization within the flow as a consequence of surges from the source; and (4) extension via lava tubes, or similar conduits through which there is little heat loss. Sulfur flows may form a relatively thin veneer over silicate flows and other surface units, given their fluidity and low mobilization temperature. Active splashing and splattering may spread sulfur over a wider area contributing the bright blooms observed in association with some Ionian flows.

Greeley, R.↗

Flows around sunspots and pores

Observations are reported yielding high-resolution white-light data regarding the flow pattern of penumbral material and granules around sunspots and pores. The data are culled from optical observations near the limit of the telescope modulation transfer function, and correlation tracking is employed to track the motions of penumbral features and granules. Dark fibrils and bright grains in the sunspots' inner penumbra regions move toward the umbra, and the opposite occurs in the outer penumbra. Before pore formation and during the pores existence granular flows are found to converge on the features. The paper also details the evolution of an emerging flux region, and two types of photospheric dark alignments are described in the region of new flux emergence.

Wang, Haimin↗

Continuous-Flow System Produces Medical-Grade Water

A continuous-flow system utilizes microwave heating to sterilize water and to thermally inactivate endotoxins produced in the sterilization process. The system is designed for use in converting potable water to medical-grade water. Systems like this one could be used for efficient, small-scale production of medical- grade water in laboratories, clinics, and hospitals. This system could be adapted to use in selective sterilization of connections in ultra-pure-water-producing equipment and other equipment into which intrusion by microorganisms cannot be tolerated. Lightweight, port - able systems based on the design of this system could be rapidly deployed to remote locations (e.g., military field hospitals) or in response to emergencies in which the normal infrastructure for providing medical-grade water is disrupted. Larger systems based on the design of this system could be useful for industrial production of medical-grade water. The basic microwave-heating principle of this system is the same as that of a microwave oven: An item to be heated, made of a lossy dielectric material (in this case, flowing water) is irradiated with microwaves in a multimode microwave cavity. The heating is rapid and efficient because it results from absorption of microwave power throughout the volume of the lossy dielectric material. In this system, a copper tube having a length of 49.5 cm and a diameter of 2.25 cm serves as both the microwave cavity and the sterilization chamber. Microwave power is fed via a coaxial cable to an antenna mounted inside the tube at mid-length (see figure). Efficient power transfer occurs due to the shift in wavelength associated with the high permittivity of water combined with the strong coupling of 2.45-GHz microwaves with rotational-vibrational transitions of the dipolar water molecule.

Akse, James R.↗