Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “malcolm”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

WE-Validate: An Open-Source Framework For Wind Power Validation

Grid operators rely on historical weather time series at existing and planned wind power plants to make informed decisions when planning for a future power grid with very high penetration of renewable power. While synthetic wind power time series have been developed based on historical weather models, their validation with actual power production data remains complex due to variations in modeling practices and methodologies. This paper introduces the WE-Validate framework, originally designed for wind speed validation and now enhanced for wind power validation with a graphical user interface to support users with minimal programming experience. Validation of wind power with WE-Validate is based on robust metrics consisting of RMSE, centered RMSE, average bias, average percent bias, mean absolute error, mean absolute percent error, cross correlation, and calculation of ramping magnitude, rate, and duration. This paper showcases WE-Validate with validation of synthetically derived power for a wind plant in Washington state for one month in 2018. Validation of the synthetic power from two comparison data sets compared with observations shows both comparison series have strong correlation with observed across weekly and monthly aggregations while suffering from persistent negative bias. The suite of metrics within WE-Validate facilitates immediate insight into the utility of the comparison data sets through compression across multiple axes. This user-friendly, open-source tool can be extended beyond wind power, making it a valuable resource for system planners and operators in different domains.

Moncheur de Rieudotte, Malcolm P.↗

Two-Level Switches for Advanced Time-Division Multiplexing

Superconducting quantum interference device (SQUID)-based time-division multiplexing (TDM) is a mature and widely implemented technology used to read out transition-edge sensor arrays. As the number of pixels in modern arrays continues to increase, a higher multiplexing factor is required to reduce the number of wires and amplifier channels. Yet, as the multiplexing factor is increased, the number of row-select wires (used to turn on a row of TDM SQUIDs in a two-dimensional configuration) also increases, limiting the reduction in array wires. We introduce a more advanced TDM architecture that enforces multi-level switching between subgroups of pixels. We show that this technique can dramatically reduce the number of required row-select lines. We also present the design, fabrication, and testing of a TDM multiplexer incorporating a two-level switch, which implements a second switch for each group of ten TDM pixels. In this application, a multiplexing factor of 100 can be addressed using ten group-select wiring pairs and ten row-select wiring pairs. We demonstrate multiplexer functionality and present measured operating margins of this new TDM multiplexer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Low-cost embedded optical sensing systems for distribution transformer monitoring

There is a mounting need for low-cost monitoring with online sensing technologies to maintain grid reliability and uptime. Here we introduce an innovative low-cost, embedded optical sensing technology initially focused on transformers that was developed and demonstrated at a major electric utility, Con Edison. A version of it that can be retrofitted onto existing transformers in the field was also developed. Two new 500 kVA distribution network transformers were built with embedded fiber-optic (FO) sensors and qualified per industry standards. Vibration, temperature, and corrosion were key parameters monitored. The first transformer with embedded FO sensors was installed at a Con Edison facility and monitored at our team’s office. The second one was installed in an urban street-side underground location with online data processing/feature extraction algorithms and monitored through a wireless router. Additionally, an older transformer was also retrofitted. Data analysis was done on these transformers showing promising correlations with their corresponding loading cycles. Furthermore, key events such as the transformer primary-side energizing, and other events were detected. In general, the technology was demonstrated over 6 months across the 3 transformers instrumented with promising results. Thus, it has the potential to enable predictive maintenance for transformers and other grid assets.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Exploration of a Combined LIBS and LA-ICP-MS Approach for Apatite Characterisation

A combined laser‐induced breakdown spectroscopy (LIBS) and laser ablation‐inductively coupled plasma‐mass spectrometry (LA‐ICP‐MS) method is demonstrated for comprehensive apatite analysis. These measurements provide elemental imaging that can be used as a screening technique for chemical selection of grains for subsequent analysis (e.g., U‐Pb geochronology) or can be used to understand elemental distributions within a single grain that would have direct textural‐chemical implications (e.g., zoning patterns). Adding LIBS as a simultaneous measurement, to LA‐ICP‐MS U‐Pb geochronology, allowed for the direct determination of F (H and O show promise for future applications) in addition to major and trace elements of interest. Here, the quantitative measurements were validated against a series of apatites with known values and used to characterise a wide range of samples. Fluorine detection limits were determined to be as low as 70 μg g ‐1 F (broadband CMOS detector) and 4.2 μg g ‐1 F (ICCD detector). U‐Pb age dating was simultaneously collected by LA‐ICP‐MS with the quantitative elemental data from LIBS, providing a comprehensive method for geochronology.

Apatite↗

NanoSIMS analysis of arsenic and selenium in cereal grain

Cereals are an important source of selenium (Se) to humans and many people have inadequate intakes of this essential trace element. Conversely, arsenic (As) is toxic and may accumulate in rice grain at levels that pose a health risk. Knowledge of the localization of selenium and arsenic within the cereal grain will aid understanding of their deposition patterns and the impact of processes such as milling. High-resolution secondary ion mass spectrometry (NanoSIMS) was used to determine the localization of Se in wheat (Triticum aestivum) and As in rice (Oryza sativa). Combined synchrotron X-ray fluorescence (S-XRF) and NanoSIMS analysis utilized the strengths of both techniques. Selenium was concentrated in the protein surrounding the starch granules in the starchy endosperm cells and more homogeneously distributed in the aleurone cells but with Se-rich hotspots. Arsenic was concentrated in the subaleurone endosperm cells in association with the protein matrix rather than in the aleurone cells. NanoSIMS indicated that the high intensity of As identified in the S-XRF image was localized in micron-sized hotspots near the ovular vascular trace and nucellar projection. This is the first study showing subcellular localization in grain samples containing parts per million concentrations of Se and As. There is good quantitative agreement between NanoSIMS and S-XRF.

59 BASIC BIOLOGICAL SCIENCES↗

The auxin efflux carrier PIN1a regulates vascular patterning in cereal roots

Barley (Hordeum vulgare) is an important global cereal crop and a model in genetic studies. Despite advances in characterising barley genomic resources, few mutant studies have identified genes controlling root architecture and anatomy, which plays a critical role in capturing soil resources. Our phenotypic screening of a TILLING mutant collection identified line TM5992 exhibiting a short-root phenotype compared with wild-type (WT) Morex background. Outcrossing TM5992 with barley variety Proctor and subsequent SNP array-based bulk segregant analysis, fine mapped the mutation to a cM scale. Exome sequencing pinpointed a mutation in the candidate gene HvPIN1a, further confirming this by analysing independent mutant alleles. Detailed analysis of root growth and anatomy in Hvpin1a mutant alleles exhibited a slower growth rate, shorter apical meristem and striking vascular patterning defects compared to WT. Expression and mutant analyses of PIN1 members in the closely related cereal brachypodium (Brachypodium distachyon) revealed that BdPIN1a and BdPIN1b were redundantly expressed in root vascular tissues but only Bdpin1a mutant allele displayed root vascular defects similar to Hvpin1a. We conclude that barley PIN1 genes have sub-functionalised in cereals, compared to Arabidopsis (Arabidopsis thaliana), where PIN1a sequences control root vascular patterning.

59 BASIC BIOLOGICAL SCIENCES↗

Root angle in maize influences nitrogen capture and is regulated by calcineurin B-like protein (CBL)-interacting serine/threonine-protein kinase 15 ( ZmCIPK15 )

Crops with reduced nutrient and water requirements are urgently needed in global agriculture. Root growth angle plays an important role in nutrient and water acquisition. A maize diversity panel of 481 genotypes was screened for variation in root angle employing a high-throughput field phenotyping platform. Genome-wide association mapping identified several single nucleotide polymorphisms (SNPs) associated with root angle, including one located in the root expressed CBL-interacting serine/threonine-protein kinase 15 (ZmCIPK15) gene (LOC100285495). Reverse genetic studies validated the functional importance of ZmCIPK15, causing a approximately 10° change in root angle in specific nodal positions. A steeper root growth angle improved nitrogen capture in silico and in the field. OpenSimRoot simulations predicted at 40 days of growth that this change in angle would improve nitrogen uptake by 11% and plant biomass by 4% in low nitrogen conditions. In field studies under suboptimal N availability, the cipk15 mutant with steeper growth angles had 18% greater shoot biomass and 29% greater shoot nitrogen accumulation compared to the wild type after 70 days of growth. We propose that a steeper root growth angle modulated by ZmCIPK15 will facilitate efforts to develop new crop varieties with optimal root architecture for improved performance under edaphic stress.

59 BASIC BIOLOGICAL SCIENCES↗

Soil penetration by maize roots is negatively related to ethylene‐induced thickening

Abstract Radial expansion is a classic response of roots to a mechanical impedance that has generally been assumed to aid penetration. We analysed the response of maize nodal roots to impedance to test the hypothesis that radial expansion is not related to the ability of roots to cross a compacted soil layer. Genotypes varied in their ability to cross the compacted layer, and those with a steeper approach to the compacted layer or less radial expansion in the compacted layer were more likely to cross the layer and achieve greater depth. Root radial expansion was due to cortical cell size expansion, while cortical cell file number remained constant. Genotypes and nodal root classes that exhibited radial expansion in the compacted soil layer generally also thickened in response to exogenous ethylene in hydroponic culture, that is, radial expansion in response to ethylene was correlated with the thickening response to impedance in soil. We propose that ethylene insensitive roots, that is, those that do not thicken and can overcome impedance, have a competitive advantage under mechanically impeded conditions as they can maintain their elongation rates. We suggest that prolonged exposure to ethylene could function as a stop signal for axial root growth.

Vanhees, Dorien J.↗

Suppression of Arabidopsis GGLT 1 affects growth by reducing the L‐galactose content and borate cross‐linking of rhamnogalacturonan‐ II

Summary Boron is a micronutrient that is required for the normal growth and development of vascular plants, but its precise functions remain a subject of debate. One established role for boron is in the cell wall where it forms a diester cross‐link between two monomers of the low‐abundance pectic polysaccharide rhamnogalacturonan‐ II ( RG ‐ II ). The inability of RG ‐ II to properly assemble into a dimer results in the formation of cell walls with abnormal biochemical and biomechanical properties and has a severe impact on plant productivity. Here we describe the effects on RG ‐ II structure and cross‐linking and on the growth of plants in which the expression of a GDP ‐sugar transporter ( GONST 3/ GGLT 1) has been reduced. In the GGLT 1 ‐silenced plants the amount of L‐galactose in side‐chain A of RG ‐ II is reduced by up to 50%. This leads to a reduction in the extent of RG ‐ II cross‐linking in the cell walls as well as a reduction in the stability of the dimer in the presence of calcium chelators. The silenced plants have a dwarf phenotype, which is rescued by growth in the presence of increased amounts of boric acid. Similar to the mur1 mutant, which also disrupts RG ‐ II cross‐linking, GGLT 1 ‐silenced plants display a loss of cell wall integrity under salt stress. We conclude that GGLT 1 is probably the primary Golgi GDP ‐L‐galactose transporter, and provides GDP ‐L‐galactose for RG ‐ II biosynthesis. We propose that the L‐galactose residue is critical for RG ‐ II dimerization and for the stability of the borate cross‐link.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of Long-Range Interaction in Lithium-Ion Battery Electrodes

The lithium-ion battery (LIB) electrode represents a complex porous composite, consisting of multiple phases including active material (AM), conductive additive, and polymeric binder. This study proposes a mesoscale model to probe the effects of the cathode composition, e.g., the ratio of active material, conductive additive, and binder content, on the electrochemical properties and performance. The results reveal a complex nonmonotonic behavior in the effective electrical conductivity as the amount of conductive additive is increased. Insufficient electronic conductivity of the electrode limits the cell operation to lower currents. Once sufficient electron conduction (i.e., percolation) is achieved, the rate performance can be a strong function of ion-blockage effect and pore phase transport resistance. In conclusion, even for the same porosity, different arrangements of the solid phases may lead to notable difference in the cell performance, which highlights the need for accurate microstructural characterization and composite electrode preparation strategies.

25 ENERGY STORAGE↗

GT2023 Front Matter

Abstract The front matter for this proceedings is available by clicking on the PDF icon.

08 HYDROGEN↗

Design, Analysis, and Experimental Testing of Hydrogen Lean Direct Injection Nozzles at Elevated Pressure

Abstract There are many challenges of commissioning a hydrogen combustor into future gas turbine engines; especially regarding achieving emissions goals. Previously, Escudero et al. and Tran et al. conducted a study to adapt the liquid fuel Lean Direct Injection (LDI) concept from Jet-A to gaseous natural gas-hydrogen blends and pure hydrogen [1], [2]. Experimental data was collected at atmospheric conditions using a Box Behnken design of experiments. The design of experiments suggested that biasing the air split in favor of the inner air circuit and increasing the swirl strength of this inner air passage resulted in improved NOx emissions, while the inverse was true for stability, which was quantified by studying the lean blowoff point (LBO) [1], [2]. The trends revealed by the original experiment [1], [2] provided a design direction for further iterations of the experimental hardware. The study presented herein describes the further investigation of such LDI injectors through experimental methods and computational fluid dynamic (CFD) simulations at atmospheric conditions, which were used to identify potential flow behaviors driving enhanced emissions performance. Further evaluation of select injectors from both studies was then conducted at elevated pressures up to 6 atmospheres. The results from both experiments are presented in this study, which include flame observations, emissions measurements, and operational challenges. NOx emissions results are reported on a volume basis in ppmvd corrected to 15% O2 and corrected for fuel. A predictive model for relating NOx emissions to test conditions at atmospheric conditions show high significance to adiabatic flame temperature while little to no significance to fuel composition for the best performing configurations. The results illustrate the connection between atmospheric testing and testing elevated pressures. The design direction indicated by the initial tests and CFD results in promising configurations for implementation into a Multi-point LDI array.

08 HYDROGEN↗

Argon–germane in situ plasma clean for reduced temperature Ge on Si epitaxy by high density plasma chemical vapor deposition

We found that the demand for integration of near infrared optoelectronic functionality with silicon complementary metal oxide semiconductor (CMOS) technology has for many years motivated the investigation of low temperature germanium on silicon deposition processes. Our work describes the development of a high density plasma chemical vapor deposition process that uses a low temperature (<460 °C) in situ germane/argon plasma surface preparation step for epitaxial growth of germanium on silicon. It is shown that the germane/argon plasma treatment sufficiently removes SiO x and carbon at the surface to enable germanium epitaxy. Finally, the use of this surface preparation step demonstrates an alternative way to produce germanium epitaxy at reduced temperatures, a key enabler for increased flexibility of integration with CMOS back-end-of-line fabrication.

36 MATERIALS SCIENCE↗

Treatment head disassembly to improve the accuracy of large electron field simulation

Purpose: The purposes of this study are to improve the accuracy of source and geometry parameters used in the simulation of large electron fields from a clinical linear accelerator and to evaluate improvement in the accuracy of the calculated dose distributions. Methods: The monitor chamber and scattering foils of a clinical machine not in clinical service were removed for direct measurement of component geometry. Dose distributions were measured at various stages of reassembly, reducing the number of geometry variables in the simulation. The measured spot position and beam angle were found to vary with the beam energy. A magnetic field from the bending magnet was found between the exit window and the secondary collimators of sufficient strength to deflect electrons 1 cm off the beam axis at 100 cm from the exit window. The exit window was 0.05 cm thicker than manufacturer's specification, with over half of the increased thickness due to water pressure in the channel used to cool the window. Dose distributions were calculated with Monte Carlo simulation of the treatment head and water phantom using EGSnrc, a code benchmarked at radiotherapy energies for electron scatter and bremsstrahlung production, both critical to the simulation. The secondary scattering foil and monitor chamber offset from the collimator rotation axis were allowed to vary with the beam energy in the simulation to accommodate the deflection of the beam by the magnetic field, which was not simulated. Results: The energy varied linearly with bending magnet current to within 1.4% from 6.7 to 19.6 MeV, the bending magnet beginning to saturate at the highest beam energy. The range in secondary foil offset used to account for the magnetic field was 0.09 cm crossplane and 0.15 cm inplane, the range in monitor chamber offset was 0.14 cm crossplane and 0.07 cm inplane. A 1.5%/0.09 cm match or better was obtained to measured depth dose curves. Profiles measured at the depth of maximum dose matched the simulated profiles to 2.6% or better at doses of 80% or more of the dose on the central axis. The profiles along the direction of MLC motion agreed to within 0.16 cm at the edge of the field. There remained a mismatch for the lower beam energies at the edge of the profile that ran parallel to the direction of jaw motion of up to 1.4 cm for the 6 MeV beam, attributed to the MLC support block at the periphery of the field left out of the simulation and to beam deflection by the magnetic field. The possibility of using these results to perform accurate simulation without disassembly is discussed. Phase-space files were made available for benchmarking beam models and other purposes. Conclusions: The match to measured large field dose distributions from clinical electron beams with Monte Carlo simulation was improved with more accurate source details and geometry details closer to manufacturer's specification than previously achieved.

61 RADIATION PROTECTION AND DOSIMETRY↗

Measurement of ionization chamber absorbed dose k{sub Q} factors in megavoltage photon beams

Purpose: Absorbed dose beam quality conversion factors (k{sub Q} factors) were obtained for 27 different types of ionization chamber. The aim was to obtain objective evidence on the performance of a wide range of chambers currently available, and potentially used for reference dosimetry, and to investigate the accuracy of the k{sub Q} calculation algorithm used in the TG-51 protocol. Methods: Measurements were made using the {sup 60}Co irradiator and Elekta Precise linac facilities at the National Research Council of Canada. The objective was to characterize the chambers over the range of energies applicable to TG-51 and determine whether each chamber met the requirements of a reference-class instrument. Chamber settling, leakage current, ion recombination and polarity, and waterproofing sleeve effects were investigated, and absorbed dose calibration coefficients were obtained for {sup 60}Co and 6, 10, and 25 MV photon beams. Only thimble-type chambers were considered in this investigation and were classified into three groups: (i) Reference chambers (''standard''0.6 cm{sup 3} Farmer-type chambers and their derivatives traditionally used for beam output calibration); (ii) scanning chambers (typically 0.1 cm{sup 3} volume chambers used for beam commissioning with 3-D scanning phantoms); and (iii) microchambers (very small volume ion chambers ({<=}0.01 cm{sup 3}) used for small field dosimetry). Results: As might be expected, 0.6 cm{sup 3} thimble chambers showed the most predictable performance and experimental k{sub Q} factors were obtained with a relative uncertainty of 0.1%. The performance of scanning and microchambers was somewhat variable. Some chambers showed very good behavior but others showed anomalous polarity and recombination corrections that are not fully explained at present. For the well-behaved chambers, agreement between measured and calculated k{sub Q} factors was within 0.4%; for some chambers, differences of more than 1% were seen that may be related to the recombination/polarity results. Use of such chambers could result in significant errors in the determination of reference dose in the clinic. Conclusions: Based on the experimental evidence obtained here, specification for a reference-class ionization chamber could be developed that would minimize the error in using a dosimetry protocol with calculated beam quality conversion factors. The experimental k{sub Q} data obtained here for a wide range of thimble chambers can be used when choosing suitable detectors for reference dosimetry and are intended to be used in the upcoming update/addendum to the AAPM TG-51 dosimetry protocol.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗