Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “lps”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Methylprednisolone Inhibits Tumor Growth and Peritoneal Seeding Induced by Surgical Stress and Postoperative Complications

Background: Surgery often introduce inflammatory response, which may promote tumor growth and metastasis of residual cancer cells. We investigated the impacts of methylprednisolone on the tumor growth and peritoneal seedings in mice treated with lipopolysaccharide (LPS), which mimics systemic inflammation induced by surgical stress and postoperative complications. Methods: The serum interleukin-6 (IL-6) levels, tumor volume, tumor weight, and the number of peritoneal nodules were investigated in tumor growth model and peritoneal seeding model using BALB/c mice and murine CT26 cancer cell lines in vivo. We conducted functional analyses of IL-6 in Western blotting and proliferation assays in vitro. We also investigated whether preoperative administration of methylprednisolone decreased postoperative serum IL-6 levels in cancer patients in a randomized clinical study. Results: In the in vivo study, methylprednisolone inhibited the LPS-induced increase of serum IL-6 levels (mean, 33,756 pg/ml vs. 5917 pg/ml; P < 0.001), tumor volume (mean, 397 mm{sup 3} vs. 274 mm{sup 3}; P = 0.019), tumor weight (mean, 0.38 g vs. 0.15 g; P = 0.020), and the number of peritoneal nodules (mean, 112 vs. 47; P = 0.002). In the in vitro study, IL-6 enhanced JAK/STAT signaling and increased the cell proliferation, and IL-6R-neutralizing antibody attenuated these effects. In the clinical study, serum IL-6 levels were significantly decreased by methylprednisolone (median, 97.5 pg/ml vs. 18.0 pg/ml; P = 0.030). Conclusions: Surgical stress and postoperative complications may enhance tumor growth due to the increase of IL-6. However, methylprednisolone can decrease serum IL-6 levels, thus inhibiting tumor growth and peritoneal seeding.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correlating transcription and protein expression profiles of immune biomarkers following lipopolysaccharide exposure in lung epithelial cells

Universal and early recognition of pathogens occurs through recognition of evolutionarily conserved pathogen associated molecular patterns (PAMPs) by innate immune receptors and the consequent secretion of cytokines and chemokines. The intrinsic complexity of innate immune signaling and associated signal transduction challenges our ability to obtain physiologically relevant, reproducible and accurate data from experimental systems. One of the reasons for the discrepancy in observed data is the choice of measurement strategy. Immune signaling is regulated by the interplay between pathogen-derived molecules with host cells resulting in cellular expression changes. However, these cellular processes are often studied by the independent assessment of either the transcriptome or the proteome. Correlation between transcription and protein analysis is lacking in a variety of studies. In order to methodically evaluate the correlation between transcription and protein expression profiles associated with innate immune signaling, we measured cytokine and chemokine levels following exposure of human cells to the PAMP lipopolysaccharide (LPS) from the Gram-negative pathogen Pseudomonas aeruginosa . Expression of 84 messenger RNA (mRNA) transcripts and 69 proteins, including 35 overlapping targets, were measured in human lung epithelial cells. We evaluated 50 biological replicates to determine reproducibility of outcomes. Following pairwise normalization, 16 mRNA transcripts and 6 proteins were significantly upregulated following LPS exposure, while only five (CCL2, CSF3, CXCL5, CXCL8/IL8, and IL6) were upregulated in both transcriptomic and proteomic analysis. This lack of correlation between transcription and protein expression data may contribute to the discrepancy in the immune profiles reported in various studies. The use of multiomic assessments to achieve a systems-level understanding of immune signaling processes can result in the identification of host biomarker profiles for a variety of infectious diseases and facilitate countermeasure design and development.

59 BASIC BIOLOGICAL SCIENCES↗

Technical Feasibility Assessment of LED Roadway Lighting on the Golden Gate Bridge

Subsequent to preliminary investigations by the Golden Gate Bridge Highway & Transportation District (GGB), in coordination with Pacific Gas & Electric (PG&E), the GATEWAY Demonstration program was asked to evaluate the technical feasibility of replacing existing roadway lighting on the bridge with products utilizing LED technology. GGB and PG&E also indicated interest in induction (i.e., electrodeless fluorescent) technology, since both light source types feature rated lifetimes significantly exceeding those of the existing high-pressure sodium (HPS) and low-pressure sodium (LPS) products. The goal of the study was to identify any solutions which would reduce energy use and maintenance without compromising the quantity or quality of existing illumination. Products used for roadway lighting on the historic bridge must be installed within the existing amber-lensed shoebox-style luminaire housings. It was determined that induction technology does not appear to represent a viable alternative for the roadway luminaires in this application; any energy savings would be attributable to a reduction in light levels. Although no suitable LED retrofit kits were identified for installation within existing luminaire housings, several complete LED luminaires were found to offer energy savings of 6-18%, suggesting custom LED retrofit kits could be developed to match or exceed the performance of the existing shoeboxes. Luminaires utilizing ceramic metal halide (CMH) were also evaluated, and some were found to offer 28% energy savings, but these products might actually increase maintenance due to the shorter rated lamp life. Plasma technology was evaluated, as well, but no suitable products were identified. Analysis provided in this report was completed in May 2012. Although LED technologies are expected to become increasingly viable over time, and product mock-ups may reveal near-term solutions, some options not currently considered by GGB may ultimately merit evaluation. For example, it would be preferable in terms of performance to simply replace existing luminaires (some of which may already be nearing end of life) with fully-integrated LED or CMH luminaires rather than replacing internal components. Among other benefits, this would allow reputable manufacturers to offer standard warranties for their products. Similarly, the amber lenses might be reformulated such that they do not render white light sources in a greenish cast, thereby allowing the use of off-the-shelf LED or CMH products. Last, it should be noted that the existing amber-lensed shoeboxes bear no daytime resemblance to the LPS luminaires originally used to light the roadway.

ceramic metal halide↗

Technical Feasibility Assessment of LED Roadway Lighting on the Golden Gate Bridge

Subsequent to preliminary investigations by the Golden Gate Bridge Highway & Transportation District (GGB), in coordination with Pacific Gas & Electric (PG&E), the GATEWAY Demonstration program was asked to evaluate the technical feasibility of replacing existing roadway lighting on the bridge with products utilizing LED technology. GGB and PG&E also indicated interest in induction (i.e., electrodeless fluorescent) technology, since both light source types feature rated lifetimes significantly exceeding those of the existing high-pressure sodium (HPS) and low-pressure sodium (LPS) products. The goal of the study was to identify any solutions which would reduce energy use and maintenance without compromising the quantity or quality of existing illumination. Products used for roadway lighting on the historic bridge must be installed within the existing amber-lensed shoebox-style luminaire housings. It was determined that induction technology does not appear to represent a viable alternative for the roadway luminaires in this application; any energy savings would be attributable to a reduction in light levels. Although no suitable LED retrofit kits were identified for installation within existing luminaire housings, several complete LED luminaires were found to offer energy savings of 6-18%, suggesting custom LED retrofit kits could be developed to match or exceed the performance of the existing shoeboxes. Luminaires utilizing ceramic metal halide (CMH) were also evaluated, and some were found to offer 28% energy savings, but these products might actually increase maintenance due to the shorter rated lamp life. Plasma technology was evaluated, as well, but no suitable products were identified. Analysis provided in this report was completed in May 2012. Although LED technologies are expected to become increasingly viable over time, and product mock-ups may reveal near-term solutions, some options not currently considered by GGB may ultimately merit evaluation. For example, it would be preferable in terms of performance to simply replace existing luminaires (some of which may already be nearing end of life) with fully-integrated LED or CMH luminaires rather than replacing internal components. Among other benefits, this would allow reputable manufacturers to offer standard warranties for their products. Similarly, the amber lenses might be reformulated such that they do not render white light sources in a greenish cast, thereby allowing the use of off-the-shelf LED or CMH products. Last, it should be noted that the existing amber-lensed shoeboxes bear no daytime resemblance to the LPS luminaires originally used to light the roadway.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A data-driven peridynamic continuum model for upscaling molecular dynamics

Nonlocal models, including peridynamics, often use integral operators that embed lengthscales in their definition. However, the integrands in these operators are difficult to define from the data that are typically available for a given physical system, such as laboratory mechanical property tests. In contrast, molecular dynamics (MD) does not require these integrands, but it suffers from computational limitations in the length and time scales it can address. To combine the strengths of both methods and to obtain a coarse-grained, homogenized continuum model that efficiently and accurately captures materials’ behavior, we propose a learning framework to extract, from MD data, an optimal Linear Peridynamic Solid (LPS) model as a surrogate for MD displacements. To maximize the accuracy of the learnt model we allow the peridynamic influence function to be partially negative, while preserving the well-posedness of the resulting model. To achieve this, we provide sufficient well-posedness conditions for discretized LPS models with sign-changing influence functions and develop a constrained optimization algorithm that minimizes the equation residual while enforcing such solvability conditions. This framework guarantees that the resulting model is mathematically well-posed, physically consistent, and that it generalizes well to settings that are different from the ones used during training. We illustrate the efficacy of the proposed approach with several numerical tests for single layer graphene. Our two-dimensional tests show the robustness of the proposed algorithm on validation data sets that include thermal noise, different domain shapes and external loadings, and discretizations substantially different from the ones used for training.

homogenization↗

The Consequences of Rayleigh-Taylor Instabilities on Implosion Dynamics in Gas-puff Z-pinch Experiments (Final Report)

The Laboratory of Plasma Studies (LPS), Cornell University, proposed to carry out a comprehensive series of gas-puff z-pinch experiments on a 1 MA pulsed power machine for the purpose of understanding the dynamics of imploding magnetized high energy density plasmas in the presence of Rayleigh-Taylor Instabilities (RTI). Cornell’s pulsed power facilities, including the associated diagnostic instruments, are largely supported under the auspices of the Center for Pulsed-power-driven High-energy-density Plasmas (the Center), an NNSA-sponsored Center of Excellence. The proposed experiments were carried out predominantly by LPS graduate student, Sophia Rocco (the “primary grad student”), in collaboration with other graduate students and the scientific and technical staff of the Center using Cornell’s 1 MA COBRA pulsed power facility and all of its associated diagnostic instruments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lithium Dendrite-Free Li 7 N 2 I-LiOH Solid Electrolytes for High Energy Lithium Batteries

All-solid-state lithium batteries (ASSLBs) hold great potential to improve the safety and energy density of today’s lithium-ion batteries by using non-flammable inorganic solid electrolytes. Solid electrolytes (SEs) are believed to prevent Li dendrite growth because of high mechanical strength and high Li+ transference numbers. Significant advances in SE have been achieved, among which, Li7La3Zr2O12 (LLZO) and Li2S–P2S5 (LPS) are the most promising SEs for bulk-type solid-state lithium batteries because of high ionic conductivities (>10-4 S/cm2). However, in contrast to our expectations, the growth of lithium dendrites is not suppressed but is facilitated in LLZOs and LPSs regardless of dopants, porosity, and crystallinity of the electrolytes. Despite the unity Li transference number and over two-times of shear modulus than that of Li metal, the critical current densities for Li plating and stripping in these SEs are less than 1.0 mA cm-2, which is one-fourth to one-tenth of that in liquid electrolytes at room temperature. The incompatibility between LLZO and LPS with Li metal seriously limits the energy density of all-solid-state batteries. The mechanism for lithium dendrite formation and growth in SEs are still disputable. Lack of understanding of the Li dendrite formation mechanism seriously impeded the development of solid-state lithium batteries. The development of the criterion for Li dendrite suppression is essential for the success of solid electrolyte lithium batteries. In this project, a criterion for Li dendrite suppression will be developed through thermodynamics and kinetics analysis of lithium dendrite nucleation/growth, which will guide the solid-state electrolyte design. Li7N2I-LiOH, Li5NI2-LiOH and Li3YCl6 solid electrolyte with high ionic conductivity and low electronic conductivity were used to validate the criterion for lithium dendrite suppression. Different surface modifications were also explored to enhance the dendrite suppression capability of SSEs.

25 ENERGY STORAGE↗

Evaluating the feasibility of tidal energy extraction at non-operational gas platforms and effects of sedimentation and sea ice in Cook Inlet (Abstract)

Littoral Power Systems (LPS) has been granted a FERC preliminary permit for the Upper Cook Inlet Tidal Energy Project in an area that includes existing non-producing natural gas platforms. LPS is working to understand the feasibility of a 2 MW tidal energy project and is considering multiple technologies, the viability of using the platforms to support deployment and operation of the technologies, as well as the environmental conditions that will interact with tidal energy devices. The proposed TEAMER work will conduct a modeling study to understand 1) current velocity and turbulence; 2) the distribution of sea ice trajectories around the platform; and 3) the likelihood of seabed erosion and deposition through an analysis of shear stress in the seabed near the platforms. The results of this work will contribute to determining the feasibility of the site for tidal energy development.

16 TIDAL AND WAVE POWER↗

Demonstration Assessment of Light-Emitting Diode (LED) Street Lighting Host Site: Lija Loop, Portland, Oregon

This report describes the process and results of a demonstration of solid-state lighting (SSL) technology in a residential street lighting application, under the U.S. Department of Energy GATEWAY Solid-State Lighting Technology Demonstration Program. In this project, eight 100W (nominal) high-pressure sodium cobra head fixtures were replaced with a like number of LED street light luminaires manufactured by Leotek, Inc. The Leotek product achieved an estimated payback in the Lija Loop installation of about 20 years for replacement scenarios and a much shorter 7.6 years for new installations. Much of the associated energy savings (55%) supporting these payback periods, however, were achieved by reducing average horizontal photopic illuminance a similar amount (53%). Examined from a different perspective, the measured performance suggests that the Leotek product is at approximate parity with the HPS cobra head in terms of average delivered photopic illumination for a given power consumption. HPS comprises the second most efficacious street lighting technology available, exceeded only by low pressure sodium (LPS). LPS technology is not considered suitable for most street lighting applications due to its monochromatic spectral output and poor color rendering ability; therefore, this LED product is performing at an efficiency level comparable to its primary competition in this application.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Bacteriophage-Induced Lipopolysaccharide Mutations in Escherichia coli Lead to Hypersensitivity to Food Grade Surfactant Sodium Dodecyl Sulfate

Bacteriophages (phages) are considered as one of the most promising antibiotic alternatives in combatting bacterial infectious diseases. However, one concern of employing phage application is the emergence of bacteriophage-insensitive mutants (BIMs). Here, we isolated six BIMs from E. coli B in the presence of phage T4 and characterized them using genomic and phenotypic methods. Of all six BIMs, a six-amino acid deletion in glucosyltransferase WaaG likely conferred phage resistance by deactivating the addition of T4 receptor glucose to the lipopolysaccharide (LPS). This finding was further supported by the impaired phage adsorption to BIMs and glycosyl composition analysis which quantitatively confirmed the absence of glucose in the LPS of BIMs. Since LPSs actively maintain outer membrane (OM) permeability, phage-induced truncations of LPSs destabilized the OM and sensitized BIMs to various substrates, especially to the food-grade surfactant sodium dodecyl sulfate (SDS). This hypersensitivity to SDS was exploited to design a T4–SDS combination which successfully prevented the generation of BIMs and eliminated the inoculated bacteria. Collectively, phage-driven modifications of LPSs immunized BIMs from T4 predation but increased their susceptibilities as a fitness cost. The findings of this study suggest a novel strategy to enhance the effectiveness of phage-based food safety interventions.

60 APPLIED LIFE SCIENCES↗

Granulibacter bethesdensis, a Pathogen from Patients with Chronic Granulomatous Disease, Produces a Penta-Acylated Hypostimulatory Glycero-D-talo-oct-2-ulosonic Acid–Lipid A Glycolipid (Ko-Lipid A)

Granulibacter bethesdensis can infect patients with chronic granulomatous disease, an immunodeficiency caused by reduced phagocyte NADPH oxidase function. Intact G. bethesdensis (Gb) is hypostimulatory compared to Escherichia coli, i.e., cytokine production in human blood requires 10–100 times more G. bethesdensis CFU/mL than E. coli. To better understand the pathogenicity of G. bethesdensis, we isolated its lipopolysaccharide (GbLPS) and characterized its lipid A. Unlike with typical Enterobacteriaceae, the release of presumptive Gb lipid A from its LPS required a strong acid. NMR and mass spectrometry demonstrated that the carbohydrate portion of the isolated glycolipid consists of α-Manp-(1→4)-β-GlcpN3N-(1→6)-α-GlcpN-(1⇿1)-α-GlcpA tetra-saccharide substituted with five acyl chains: the amide-linked N-3′ 14:0(3-OH), N-2′ 16:0(3-O16:0), and N-2 18:0(3-OH) and the ester-linked O-3 14:0(3-OH) and 16:0. The identification of glycero-d-talo-oct-2-ulosonic acid (Ko) as the first constituent of the core region of the LPS that is covalently attached to GlcpN3N of the lipid backbone may account for the acid resistance of GbLPS. In addition, the presence of Ko and only five acyl chains may explain the >10-fold lower proinflammatory potency of GbKo–lipidA compared to E. coli lipid A, as measured by cytokine induction in human blood. These unusual structural properties of the G.bethesdensis Ko–lipid A glycolipid likely contribute to immune evasion during pathogenesis and resistance to antimicrobial peptides.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Particulate contamination spectrometer. Volume 1: Technical report

A laser particulate spectrometer (LPS) system was developed to measure the size and speed distributions of particulate (dusts, aerosols, ice particles, etc.) contaminants. Detection of the particulates was achieved by means of light scattering and extinction effects using a single laser beam to cover a size range of 0.8 to 275 microns diameter and a speed range of 0.2 to 20 meter/second. The LPS system was designed to operate in the high vacuum environment of a space simulation chamber with cold shroud temperatures ranging from 77 to 300 K.

Schmitt, R. J.↗

A laser particulate spectrometer for a space simulation facility

A laser particulate spectrometer (LPS) system was developed to measure the size and speed distributions of particulate contaminants. Detection of the particulates is achieved by means of light scattering and extinction effects using a single laser beam to cover a size range of 0.8 to 275 microns diameter and a speed range of 0.2 to 20 meters/second. The LPS system was designed to operate in the high-vacuum environment of a space simulation chamber with cold shroud temperatures ranging from 77 to 300 K.

Schmitt, R. J.↗

Launch processing system transition from development to operation

The Launch Processing System has been under development at Kennedy Space Center since 1973. A prototype system was developed and delivered to Marshall Space Flight Center for Solid Rocket Booster checkout in July 1976. The first production hardware arrived in late 1976. The System uses a distributed computer network for command and monitoring and is supported by a dual large scale computer system for 'off line' processing. A high level of automation is anticipated for Shuttle and Payload testing and launch operations to gain the advantages of short turnaround capability, repeatability of operations, and minimization of operations and maintenance (O&M) manpower. Learning how to efficiently apply the system is our current problem. We are searching for more effective ways to convey LPS system performance characteristics from the designer to a large number of users. Once we have done this, we can realize the advantages of LPS system design.

Paul, H. C.↗

Soft X-ray observations of large-scale coronal active region brightenings

One hundred fifty-six large-scale enhancements of X-ray emission from solar active regions were studied on full-disk filterheliograms to determine characteristic morphology and expansion rates for heated coronal plasma. The X-ray photographs were compared with H-alpha observations of flares, sudden filament disappearances, sprays, and loop prominence systems (LPS). Eighty-one percent of the X-ray events were correlated with H-alpha filament activity, but only 44% were correlated with reported H-alpha flares. The X-ray enhancements took the form of loops or arcades of loops ranging in length from 60,000 km to 520,000 km and averaging 15,000 km in width. Lifetimes ranged from at least 3 hr to more than 24 hr. The event frequency was approximately 1.4 per day. X-ray loop arcades evolved from sharp-edged clouds in cavities vacated by rising H-alpha filaments. Expansion velocities of the loops were about 50 km/s immediately after excitation and 1-10 km/s several hours later. These long-lived loop arcades are identified with LPS, and it is suggested that the loops outlined magnetic fields which were reconnecting after filament eruptions. Another class of X-ray-enhanced loops stretched outside active regions and accompanied sprays or lateral filament ejections. It is suggested that these loops outlined closed magnetic fields guiding slow-mode shocks from flares and filament eruptions.

Rust, D. M.↗

Software Reliability Issues Concerning Large and Safety Critical Software Systems

This research was undertaken to provide NASA with a survey of state-of-the-art techniques using in industrial and academia to provide safe, reliable, and maintainable software to drive large systems. Such systems must match the complexity and strict safety requirements of NASA's shuttle system. In particular, the Launch Processing System (LPS) is being considered for replacement. The LPS is responsible for monitoring and commanding the shuttle during test, repair, and launch phases. NASA built this system in the 1970's using mostly hardware techniques to provide for increased reliability, but it did so often using custom-built equipment, which has not been able to keep up with current technologies. This report surveys the major techniques used in industry and academia to ensure reliability in large and critical computer systems.

Kamel, Khaled↗

Energy Efficient Engine Low Pressure Subsystem Aerodynamic Analysis

The objective of this study was to demonstrate the capability to analyze the aerodynamic performance of the complete low pressure subsystem (LPS) of the Energy Efficient Engine (EEE). Detailed analyses were performed using three- dimensional Navier-Stokes numerical models employing advanced clustered processor computing platforms. The analysis evaluates the impact of steady aerodynamic interaction effects between the components of the LPS at design and off- design operating conditions. Mechanical coupling is provided by adjusting the rotational speed of common shaft-mounted components until a power balance is achieved. The Navier-Stokes modeling of the complete low pressure subsystem provides critical knowledge of component acro/mechanical interactions that previously were unknown to the designer until after hardware testing.

Hall, Edward J.↗

Energy Efficient Engine Low Pressure Subsystem Flow Analysis

The objective of this project is to provide the capability to analyze the aerodynamic performance of the complete low pressure subsystem (LPS) of the Energy Efficient Engine (EEE). The analyses were performed using three-dimensional Navier-Stokes numerical models employing advanced clustered processor computing platforms. The analysis evaluates the impact of steady aerodynamic interaction effects between the components of the LPS at design and off-design operating conditions. Mechanical coupling is provided by adjusting the rotational speed of common shaft-mounted components until a power balance is achieved. The Navier-Stokes modeling of the complete low pressure subsystem provides critical knowledge of component aero/mechanical interactions that previously were unknown to the designer until after hardware testing.

Hall, Edward J.↗