Investigation of Space Based Solid State Coherent Lidar

This report describes the work performed over the period of October 1, 1997 through March 31, 2001. Under this contract, UAH/CAO participated in defining and designing the SPAce Readiness Coherent Lidar Experiment (SPARCLE) mission, and developed the instrument's optical subsystem. This work was performed in collaborative fashion with NASA/MSFC engineers at both UAH/CAO and NASA/MSFC facilities. Earlier work by the UAH/CAO had produced a preliminary top-level system design for the Shuttle lidar instrument meeting the proposed mission performance requirements and the Space Shuttle Hitchhiker canister volume constraints. The UAH/CAO system design efforts had concentrated on the optical and mechanical designs of the instrument. The instrument electronics were also addressed, and the major electronic components and their interfaces defined. The instrument design concept was mainly based on the state of the transmitter and local oscillator laser development at NASA Langley Research Center and Jet Propulsion Laboratory, and utilized several lidar-related technologies that were either developed or evaluated by the NASA/MSFC and UAH/CAO scientists. UAH/CAO has developed a comprehensive coherent lidar numerical model capable of analyzing the performance of different instrument and mission concepts. This model uses the instrument configuration, atmospheric conditions and current velocity estimation theory to provide prediction of instrument performance during different phases of operation. This model can also optimize the design parameters of the instrument.

Amzajerdian, Farzin↗

Status and Progress on the Upgraded Infrared Spatial Interferometer

The U.C. Berkeley Infrared Spatial Interferometer is a two telescope stellar interferometer operating in the 9-12 micron atmospheric window, utilizing heterodyne detection with CO2 laser local oscillators. Science with the ISI has been focused on the measurements of the spatial distribution of dust and molecules around mass-losing late type stars, and more recently precision measurements of stellar diameters in the mid-infrared avoiding molecular lines. Also during the past few years, a NSF sponsored program of expansion from two to three telescopes has been underway. This expansion will allow the ISI to make visibility observations on three simultaneous baselines and a measure a closure phase. The third telescope was completed last year and shipped to Mt. Wilson, and more recently a Central Control Facility and Master Laser Oscillator Facility were also completed and recently shipped to Mt. Wilson. In this talk we report progress on this program and highlight some of the most recent astrophysical results.

Danchi, W. C.↗

Early Mission Orbit Determination Error Analysis Results for Low-Earth Orbiting Missions using TDRSS Differenced One-way Doppler Tracking Data

Differencing multiple, simultaneous Tracking and Data Relay Satellite System (TDRSS) one-way Doppler passes can yield metric tracking data usable for orbit determination for (low-cost) spacecraft which do not have TDRSS transponders or local oscillators stable enough to allow the one-way TDRSS Doppler tracking data to be used for early mission orbit determination. Orbit determination error analysis results are provided for low Earth orbiting spacecraft for various early mission tracking scenarios.

Marr, Greg C.↗

The Beauty and Limitations of 10 Micron Heterodyne Interferometry (ISI)

Until recently, heterodyne interferometry at 10 microns has been the only successful technique for stellar interferometry in the very difficult atmospheric window from 9-12 microns. For most of its operational lifetime the U.C. Berkeley Infrared Spatial Interferometer was a single-baseline two telescope (1.65 m aperture) system using CO2 lasers as local oscillators. This instrument was designed and constructed from 1983-1988, and first fringes were obtained at Mt. Wilson in June 1988. During the past few years, a third telescope was constructed and just recently the first closure phases were obtained at 11.15 microns. We discuss the history, physics and technology of heterodyne interferometry in the mid-infrared, and some key astronomical results that have come from this unique instrument.

Danchi, William C.↗

A Low Cost Single Chip VDL Compatible Transceiver ASIC

Recent trends in commercial communications system components have focussed almost exclusively on cellular telephone technology. As many of the traditional sources of receiver components have discontinued non-cellular telephone products, the designers of avionics and other low volume radio applications find themselves increasingly unable to find highly integrated components. This is particularly true for low power, low cost applications which cannot afford the lavish current consumption of the software defined radio approach increasingly taken by certified device manufacturers. In this paper, we describe a low power transceiver chip targeting applications from low VHF to low UHF frequencies typical of avionics systems. The chip encompasses a selectable single or double conversion design for the receiver and a low power IF upconversion transmitter. All local oscillators are synthesized and integrated into the chip. An on-chip I-Q modulator and demodulator provide baseband modulation and demodulation capability allowing the use of low power, fixed point signal processing components for signal demodulation. The goal of this program is to demonstrate a low cost VDL mode-3 transceiver using this chip to receive text weather information sent using 4-slot TDMA with no support for voice. The data will be sent from an experimental ground station. This work is funded by NASA Glenn Research Center.

Becker, Robert↗

High-Temperature Superconducting/Ferroelectric, Tunable Thin-Film Microwave Components

At the NASA Lewis Research Center, ferroelectric films such as SrTiO3 and Ba(sub x)Sr(sub 1-x)TiO3, are being used in conjunction with YBa(sub 2)Cu(sub 3)O(sub 7-delta) high-temperature superconducting thin films to fabricate tunable microwave components such as filters, phase shifters, and local oscillators. These structures capitalize on the variation of the dielectric constant of the ferroelectric film upon the application of a direct-current electric field, as well as on the low microwave losses of high-temperature superconductors relative to their conventional conductor counterparts. For example, the surface resistance for a YBa(sub 2)Cu(sub 3)O(sub 7-delta) thin film at 10 GHz and 77 K is more than two orders of magnitude lower than that of copper or gold at the same temperature and frequency. SrTiO3 and Ba(sub x)Sr(sub 1-x)TiO3 films are used because their crystal structure and lattice parameters are similar to those of YBa(sub 2)Cu(sub 3)O(sub 7-delta), thus enabling the growth of highly textured YBa(sub 2)Cu(sub 3)O(sub 7-delta) films with high critical current densities (i.e., greater than 1 MA/sq cm) on the underlying ferroelectric film, or alternatively, of highly textured ferroelectric film on the underlying YBa(sub 2)Cu(sub 3)O(sub 7-delta) film.

Miranda, Felix A.↗

RACE and Calculations of Three-dimensional Distributed Cavity Phase Shifts

The design for RACE, a Rb-clock flight experiment for the ISS, is described. The cold collision shift and multiple launching (juggling) have important implications for the design and the resulting clock accuracy and stability. We present and discuss the double clock design for RACE. This design reduces the noise contributions of the local oscillator and simplifies and enhances an accuracy evaluation of the clock. As we try to push beyond the current accuracies of clocks, new systematic errors become important. The best fountain clocks are using cylindrical TE(sub 011) microwave cavities. We recently pointed out that many atoms pass through a node of the standing wave microwave field in these cavities. Previous studies have shown potentially large frequency shifts for atoms passing through nodes in a TE(sub 013) cavity. The shift occurs because there is a small traveling wave component due to the absorption of the copper cavity walls. The small traveling wave component leads to position dependent phase shifts. To study these effects, we perform Finite Element calculations. Three-dimensional Finite Element calculations require significant computer resources. Here we show that the cylindrical boundary condition can be Fourier decomposed to a short series of two-dimensional problems. This dramatically reduces the time and memory required and we obtain (3D) phase distributions for a variety of cavities. With these results, we will be able to analyze this frequency shift in fountain and future space clocks.

Li, Ruoxin↗

Thin-Film Ferroelectric Tunable Microwave Devices Being Developed

Electronically tunable microwave components have become the subject of intense research efforts in recent years. Many new communications systems would greatly benefit from these components. For example, planned low Earth orbiting satellite networks have a need for electronically scanned antennas. Thin ferroelectric films are one of the major technologies competing to fill these applications. When a direct-current (dc) voltage is applied to ferroelectric film, the dielectric constant of the film can be decreased by nearly an order of magnitude, changing the high-frequency wavelength in the microwave device. Recent advances in film growth have demonstrated high-quality ferroelectric thin films. This technology may allow microwave devices that have very low power and are compact, lightweight, simple, robust, planar, voltage tunable, and affordable. The NASA Lewis Research Center has been designing, fabricating, and testing proof-of-concept tunable microwave devices. This work, which is being done in-house with funding from the Lewis Director's Discretionary Fund, is focusing on introducing better microwave designs to utilize these materials. We have demonstrated Ku- and K-band phase shifters, tunable local oscillators, tunable filters, and tunable diplexers. Many of our devices employ SrTiO3 as the ferroelectric. Although it is one of the more tunable and easily grown ferroelectrics, SrTiO3 must be used at cryogenic temperatures, usually below 100 K. At these temperatures, we frequently use high-temperature superconducting thin films of YBa2Cu3O7-8 to carry the microwave signals. However, much of our recent work has concentrated on inserting room-temperature ferroelectric thin films, such as BaxSr1- xTiO3 into these devices. The BaxSr1-xTiO3 films are used in conjuction with normal metal conductors, such as gold.

VanKeuls, Frederick W.↗

Cryogenic operation of GaAs based multiplier chains to 400 GHz

The FIRST/HIFI mission allows for the local oscillator frequency multiplier chains to be cooled to 120 - 150 K in order to increase available output power. This paper will discuss the implication of cooling on GaAs based planar Schottky diode varactors for flight applications.

cooled Schottky varactors↗

Fixed-Tuned Submillimeter Waveguide Multipliers Using MMIC Technology

In preparation for the insturment ammouncement of opportunity for the Far Infrared and Submillimeter Space Telescope, and ESA/NASA space astrophysics observatory mission, local oscillator sources at high frequencies (1200 GHz) are being developed. As part of a multiplier chain beginning at ~100 GHz we are developing single and multiple diode waveguide circuits up to 640 GHz.

Far Infrared Submillimeter Space Telescope↗

An All-Optical Microwave Mixer with 8db RF Gain

An all-optical microwave mixer with an 8dB RF gain is demonstrated by using a semiconductor optical amplifier (SOA). 6GHz RF signal on a 1312 nm optical carrier is up-converted and down-converted to 1GHZ and 11 GHz by a 5GHz local oscillation (LO) signal on a 1320 nm optical carrier. Such a carrier could readily extend to millimeter wave range.

microwave mixer fiberoptics fiber optic transmissi↗

Progress Report on the Improved Linear Ion Trap Physics Package

This article describes the first operational results from the extended linear ion trap frequency standard now being developed at JPL. This new design separates the state selection/interrogation region from the more critical microwave resonance region where the multiplied local oscillator (LO) signal is compared to the stable atomic transition. Hg+ ions have been trapped, shuttled back and forth between the resonance and state selection traps. In addition, microwave transitions between the Hg+ clock levels have been driven in the resonance trap and detected in the state selection trap.

Linear Ion Trap↗

Low-Noise Wide Bandwith, Hot Electron Bolometer Mixers for Submillimeter Wavelengths

Recently a novel superconductive hot-electron micro-bolometer has been proposed which is both fast and sensitive (D. E. Prober, Appl. Phys. Lett. 62, 2119, 1993). This device has several important properties which make it useful as a heterodyne sensor for radioastronomy applications at frequencies above 1 THz. The thermal response time of the device is fast enough, several 10's of picoseconds, to allow for IF's of several GHz. This bolometer mixer should operate well up to at least 10 THz. There is no energy gap limitation as in an SIS mixer, since the mixing process relies on heating of the electron gas. In fact, rf power is absorbed more uniformly above the gap frequency. The mixer noise should be near quantum-limited, and the local oscillator (LO) power requirement is very low: / 10 nW for a Nb device. One of the unique features of this device is that it employs rapid electron diffusion into a normal metal, rather than phonon emission, as the thermal conductance that cools the heated electrons. In order for diffusion to dominate over phonon emission, the device must be short, less than 0.5.

Bolometer Mixers↗

Monolithic Power Amplifiers Covering 70-115 GHz

A number of monolithic W-band power amplifiers have been developed for local oscillators of the Far Infrared and Sub-millimeter Telescope.

power amplifiers monolithic microwave integrated c↗

LO sources for 1-3 THz: present status and future prospective

This talk will present an overview of the current technologies that are available for implementing local oscillator sources for 1-3 THz applications. Progress to date on specific components will be discussed in some detail. Outstanding issues and concerns regarding practical implementation of these new technologies will also be discussed.

Schottky diode multipliers↗

Initial Results of the Geosynchronous Synthetic Thinned Array Radiometer (GeoSTAR)

An error budget is presented to meet 1 Kelvin radiometric accuracy in a geostationary atmospheric sounder with 50 km spatial resolution on the earth. The gain and phase errors are weighted by the magnitude of visibility versus antenna separation, and requirements range between approx.0.5% and 0.3 degrees of amplitude and phase, respectively, for the closest spacings at the center of the array, and about 5% and 3 degrees for the majority of the array. The latter requirement is met by our design without any special testing or stabilizations by reference signals. The former is met using an internal noise diode reference and by measuring the detailed antenna patterns on the antenna range. Biases and other additive errors in the raw visibility samples must be below about 2 mK on average, and this requirement is met by a phase shifting scheme applied to the local oscillator distribution. An outline of the data processing is presented, along with the first images from this system.

Synthetic Thinned Aperture Radiometer (STAR)↗

Frequency and Phase-lock Control of a 3 THz Quantum Cascade Laser

We have locked the frequency of a 3 THz quantum cascade laser (QCL) to that of a far-infrared gas laser with a tunable microwave offset frequency. The locked QCL line shape is essentially Gaussian, with linewidths of 65 and 141 kHz at the -3 and -10 dB levels, respectively. The lock condition can be maintained indefinitely, without requiring temperature or bias current regulation of the QCL other than that provided by the lock error signal. The result demonstrates that a terahertz QCL can be frequency controlled with l-part-in-lO(exp 8) accuracy, which is a factor of 100 better than that needed for a local oscillator in a heterodyne receiver for atmospheric and astronomic spectroscopy.

Betz, A. L.↗