Critical fluctuations in liquid–liquid extraction organic phases controlled by extractant and diluent molecular structure

Extractant aggregation in liquid–liquid extraction organic phases impacts extraction energetics and is related to the deleterious efficiency-limiting liquid–liquid phase transition known as third phase formation. Using small angle X-ray scattering, we find that structural heterogeneities across a wide range of compositions in binary mixtures of malonamide extractants and alkane diluents are well described by Ornstein–Zernike scattering. This suggests that structure in these simplified organic phases originates from the critical point associated with the liquid–liquid phase transition. To confirm this, we measure the temperature dependence of the organic phase structure, finding critical exponents consistent with the 3D Ising model. Molecular dynamics simulations were also consistent with this mechanism for extractant aggregation. Due to the absence of water or any other polar solutes required to form reverse-micellar-like nanostructures, these fluctuations are inherent to the binary extractant/diluent mixture. Further, we also show how the molecular structure of the extractant and diluent modulate these critical concentration fluctuations by shifting the critical temperature: critical fluctuations are suppressed by increasing extractant alkyl tail lengths or decreasing diluent alkyl chain lengths. This is consistent with how extractant and diluent molecular structure are known to impact metal and acid loading capacity in many-component LLE organic phases, suggesting phase behavior of practical systems may be effectively studied in simplified organic phases. Overall, the explicit connection between molecular structure, aggregation and phase behavior demonstrated here will enable the design of more efficient separations processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Discrete and Integrated Solutions for Hybrid PV Plants Without Momentary Cessation in Low SCR and High Penetration PE Grids

With the increased penetration of power electronic (PE) based loads and sources, advanced solutions may be required for the enhancement of grid stability in regions with low short circuit ratio (SCR) and high penetration PE grids. The requirement of advanced solutions arises from the gradual paradigm shift of the electric grid from the traditional electric machine dominant system to a high penetration of PE-based system. One of the major challenges with such systems in recent times is the momentary cessation during alternating current (ac) grid transmission faults. During momentary cessation, PE-based resources cease to operate, thus creating probable reliability challenges for the grid. In this paper, potential feasible options to provide continuity of operation during such scenarios are presented. The options are considered through identifying upgrades in existing and upcoming discrete development of photovoltaic (PV) and energy storage systems (ESS) termed as discrete hybrid PV plants. Additionally, an advanced concept of integrated development of PV and ESS connecting to ac transmission grid links called multi-port autonomous reconfigurable solar power plant (MARS) is evaluated. The developed new solutions are evaluated for different grid use cases and scenarios in PSCAD.

Marthi, Phani Ratna Vanamali↗

End-Use Load Profiles for the U.S. Building Stock: Practical Guidance on Accessing and Using the Data

End-use load profiles (EULP), which quantify how and when energy is used, are critically important to utilities, public utility commissions, state energy offices, and other stakeholders. Applications of EULPs focus on understanding how efficiency, demand response, and other distributed energy resources are valued and used in R&D prioritization, utility resource and distribution system planning, and state and local energy planning and regulations. Consequently, high-quality EULPs are critical for widespread adoption of electrification, demand flexibility, and grid-interactive efficient buildings. For example, EULPs can be used to forecast energy savings in buildings or to identify energy using activities that can be shifted to different times of the day.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Translytics: A Novel Approach for Runtime Selection of Database Layout Based on User’s Context

Currently, organizations have to maintain separate systems for transactions and analytics inside the company. Notably, different vendors provide the capabilities for either of these tasks that require specialized hardware or software. Data engineers are required to retrieve data from one source and transform it into another format to obtain the maximum benefit in a minimum time. Organizations strive for a competitive advantage that is achieved by fetching data from their customers and getting insights earliest for timely decision making. Present practices do not permit the view of the latest data for analytics since the first data have to be fetched from the source, transformed, and loaded to other systems to be utilized for analysis by relevant teams. This paper introduces a single system for both transactions and analytics. Our proposed solution would permit companies to seamlessly adapt our solution without the need to shift all of their data to newer systems and allow all the teams. It would grant all the teams to have a view of the latest available data without extra expertise and budget.

Tanvir, Muhammad Makhshif↗

Advanced Sensors & Controls FWP Overview

Fossil energy power generation is needed now and in the future, but its role is shifting from baseload operation to fulfilling dispatchable power needs in regions of the United States. Novel sensors and controls will help to increase efficiency, minimize emissions, and reduce operating costs of existing power generation technologies under this increased load following role; and help enable next generation power systems with high efficiency and greater operational flexibility.<br>

Buric, Michael↗

STOCHASTIC OPTIMAL POWER FLOW FOR REAL-TIME MANAGEMENT OF DISTRIBUTED RENEWABLE GENERATION AND DEMAND RESPONSE (Final Report)

To meet the grand challenge of a sustainable energy future, there has been a surge of interest in renewable energy. Today, the uncertainty associated with renewable resources is handled by using operating reserves. The high penetration of renewable resources, however, introduces difficult-to-control dynamics and challenges for power system operation. Decision support tools are necessary at the bulk system operational level to recognize and efficiently utilize renewable resources and distributed demand response products in concert with traditional grid resources. It is envisaged that responsive load can potentially have very significant cost advantages over either spinning or non-spinning ramping reserve. Critical decisions are made during hour(s)-ahead and real-time power system operation regarding the commitment and dispatch of generators to ensure power delivery is both reliable and economic. These decisions are typically made by a security constrained optimal flow, which determines future generator commitments, dispatches, and ensures adequate reserves are available in the event of a contingency (unexpected outage) or if future system conditions deviate from forecasts. However, security has been always based on a pre-specified subset of contingency constraints whose enforcement does not guarantee security under all possible future possibilities while also giving little or no weight to the likelihood of each contingent event or the severity of its consequences. Existing tools, which are based exclusively on deterministic optimization models, do not yield optimal operational decisions to address these new challenges, in terms of both reliability and cost-effectiveness. This project has focused on developing a stochastic optimal power flow (SOPF) framework, which integrates renewable resource uncertainty, load uncertainty, distributed storage (DS), demand response (DR) products, in a holistic manner to address the uncertainty associated with ever-increasing renewable resources, along with the inclusion of distributed demand response products in future power systems. A proof-of-concept problem was created using the Pennsylvania-Jersey-Maryland (PJM) power system network. Synthetic wind generation was added to the system to simulate 50% wind penetration. A 1-hour test of SOPF operation indicated more than 6% operational cost savings. The project continued by adding the Midwestern Independent System Operator (MISO) as a partner, with focus shifting from SOPF to Stochastic Look-Ahead Unit Commitment (SLAC). Unlike PJM, MISO is faced with significant renewable energy resources within its footprint and is challenged with substantial uncertainty in its operations. The SLAC distinguishes itself from existing tools that operators use. At best, today’s tools solve two to three cases independently, where one or two system parameters, such as forecasted load level (e.g., a low, base, and high forecast), are varied and the resulting scenarios are analyzed independently. The stochastic-based optimization of SLAC leverages statistical information from an ensemble of potential operational scenarios and their respective likelihood. The SLAC output can be translated into valuable information to the operator such as suggested commitments, optimal scheduling and dispatch of resources, reserve requirements at both locational and zonal resolutions, ramping availability and requirements, availability of demand response including operational guidance concerning the near-term and real-time coordination between distributed energy resources, and utilization of distributed storage resources. The developed SOPF/SLAC tool, a stand-alone tool compatible with existing EMSs, will provide system operators with unprecedented visibility, flexibility and predictability to these resources and operational guidance concerning the real-time coordination between DERs and DR/DS products. The game changing and practical impact of this disruptive technology will be dramatic and will usher in a new era in the electric power industry, wherein green energy concepts are fully embraced, and electric power costs are lowered throughout the nation.

42 ENGINEERING↗

Secondary-Side Active Rectifier Synchronization and Control in LCC-LC Compensated Inductive Power Transfer Systems

This paper proposes a communication-less synchronization and output power control strategy for LCC-LC compensated inductive power transfer systems with a secondaryside active rectifier. By replacing the passive rectifier with an active bridge, the proposed architecture eliminates the need for a separate secondary-side DC-DC converter and enables direct regulation of battery power. The key challenge in such a system is achieving robust synchronization of the secondary active bridge with the primary inverter without access to primary-side signals. To address this issue, the secondary-side variables are analyzed and the current through the secondary series inductor is identified as a load-independent synchronization variable with a fixed phase relationship to the primary excitation. A fixed-frequency second order generalized (SOGI)-based phase locked loop (PLL) is used to estimate the switching phase and frequency, and a phase-shift-based output power controller is developed using a phasor-transformer model of the active bridges. A modified control formulation is further introduced to remove phase-dependent loop-gain variation and simplify controller design. Simulation results validate the proposed method under both fixed and varying switching-frequency conditions, demonstrating successful frequency tracking from 82 kHz to 88 kHz and accurate output power regulation over a wide operating range. The proposed method offers a compact and effective solution for high-power IPT systems by enabling secondary-side synchronization and control without wireless communication or an additional DC-DC conversion stage.

Fernandes, Arnold Anthony [ORNL] (ORCID:0009000631↗

Submodule-Level Decentralized Control for Cascaded Quadruple Active Bridge-Based Medium-Voltage Converters

High-power, low-voltage DC (LVDC) loads, such as AI data centers, electric vehicle fast-charging hubs, and hydrogen electrolyzers, are accelerating the deployment of solid-state transformers (SSTs) that directly interface medium-voltage AC (MVAC) to LVDC, streamlining power delivery. This paper proposes a submodule-level decentralized control strategy for an SST comprising a cascaded H-bridge (CHB) active rectifier on the MVAC side and per-module quadruple-active-bridge (QAB) converters on the LVDC side with local controllers. The proposed strategy eliminates the need for high-fidelity, real-time cross-isolation communication by synchronizing all active bridges to a common heartbeat signal and enabling the primary- and secondary-side controllers to generate independent local control signals (phase shifts). The resultant phase shifts naturally govern average and double-line frequency power transfer between active bridges, enabling each side to meet its control objectives using only local measurements. Detailed controller design considerations are presented based on a stability analysis. Comprehensive electromagnetic-transient simulations demonstrate tight DC-link voltage regulation, high-quality grid currents, and robust operation under load transients and grid disturbances, without real-time communication among the submodule controllers. These results indicate that the proposed scheme can significantly enhance the reliability, scalability, and flexibility of cascaded bridge-based medium-voltage converters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Submodule-Level Decentralized Control for Cascaded Quadruple Active Bridge-Based Medium-Voltage Converters: Preprint

High-power, low-voltage DC (LVDC) loads, such as AI data centers, electric vehicle fast-charging hubs, and hydrogen electrolyzers, are accelerating the deployment of solid-state transformers (SSTs) that directly interface medium-voltage AC (MVAC) to LVDC, streamlining power delivery. This paper proposes a submodule-level decentralized control strategy for an SST comprising a cascaded H-bridge (CHB) active rectifier on the MVAC side and per-module quadruple-active-bridge (QAB) converters on the LVDC side with local controllers. The proposed strategy eliminates the need for high-fidelity, real-time cross-isolation communication by synchronizing all active bridges to a common heartbeat signal and enabling the primary- and secondary-side controllers to generate independent local control signals (phase shifts). The resultant phase shifts naturally govern average and double-line frequency power transfer between active bridges, enabling each side to meet its control objectives using only local measurements. Detailed controller design considerations are presented based on a stability analysis. Comprehensive electromagnetic-transient simulations demonstrate tight DC-link voltage regulation, high-quality grid currents, and robust operation under load transients and grid disturbances, without real-time communication among the submodule controllers. These results indicate that the proposed scheme can significantly enhance the reliability, scalability, and flexibility of cascaded bridge-based medium-voltage converters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sensitivity Effects of High Temperature Overhead Conductors to Line Rating Variables

For traditional overhead transmission lines, the maximum allowable conductor operating temperature on ASCR, AAC, or AAAC lines for determining the static line ratings can be quite low, typically well under 100 C. At these low temperatures, the primary driver for determining static line ratings are assumptions made about the wind speed and direction and the ambient temperature. Assumptions for solar loading and emitted thermal radiation, driven by line emissivity and absorptivity, are secondary factors, and only provide small changes to the static ratings. However, when considering newer high temperature conductors such as ACSS, ACCR, ZTACIR, and ACCC® the maximum allowable conductor temperatures can be significantly higher, up to 250° C. This higher temperature shifts the importance of the emissivity assumptions of the overhead transmission line, due to the nature of the T4 dependence of the radiative heat loss compared to the T1 dependence of the convective heat loss, as well as shifting the dependency on local wind conditions. Typical assumptions in the United States for the emissivity/absorptivity of overhead transmission lines in determining the static ratings are to use a value of 0.5 for both parameters or set a value in the range of 0.7 to 0.9. Recent experimental tests at EPRI have shown that higher emissivity aging assumptions may not be valid in some regions of the US, and that actual values may be much lower (0.25-0.45) than older studies have predicted (0.8-0.9). Here, the assumptions of different US Regional Transmission Operators (RTOs) and different utilities within RTOs are examined for the static ratings for traditional lower operating temperatures up to 100° C as well as with the higher maximum temperature conductors associated with newer conductor designs at 250° C. The sensitivity of the static ratings is examined at both lower and higher temperature conductors with respect to overhead line emissivity and absorptivity, wind speed, wind direction, and solar loading, and ambient temperature. It is shown that the effects of the conductor absorptivity, solar flux and ambient temperature on the static rating are increased when the transmission line has a lower maximum conductor temperature. The effects of the conductor emissivity, wind direction and wind speed have increased effects on the static rating when the transmission line has a higher maximum conductor temperature. In addition, example weather data is used to calculate the conductor temperature with different line emissivity and absorptivity assumptions. This shows the effect of assumptions made for emissivity only has a minor impact for low temperature lines, but for high temperature transmission lines can cause a 150-200° C temperature swing.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Crowded supported metal atoms on catalytically active supports may compromise intrinsic activity: A case study of dual-site Pt/α-MoC catalysts

Increasing the surface population of supported catalytic sites, assuming these sites are stable, is considered a straightforward approach to improving the overall catalytic performance. Here, we report an exception represented by the Pt/α-MoC catalysts featuring atomically dispersed Pt. The Pt/α-MoC catalysts display very high activity for the reverse water gas shift reaction with near 100% CO selectivity for CO 2 :H 2 ratios from 0.25 to 4 and from 250 to 400 °C. Despite the excellent performance, the intrinsic activity per Pt-centric catalytic center declines as the Pt loading increases from 0.1 to 1.0 wt%. With the dispersed Pt evolving from isolated atoms to fully exposed ensembles, the shrinking inter-Pt-atom space impedes CO 2 activation at the critical Pt-Mo interfaces, where the Pt shall temporarily take the -O intermediates. The Pt, even as atomically dispersed without noticeable sintering, is underutilized in such a crowded state. This caution for high-loading catalyst design is translational to other systems where the direct catalytic roles of the supports are crucial.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Incentivizing Distributed Energy Resource Participation in Grid Services

The bulk power system is experiencing a dramatic shift as renewable generation growth continues to accelerate. Large-scale renewables adoption will help societies transition to a low-carbon, low-cost, and environmentally friendly electrical power system. However, the transition from a paradigm of generation following load to one where load follows generation will require large-scale interconnection and coordinated operation of Distributed Energy Resources (DERs), supported by open communication protocols. In this future grid scenario, DER aggregations will provide critical grid services that enable high penetration levels of renewable generation. This position paper presents an Energy Service Interface (ESI) that defines scope for ensuring secure, trustworthy information exchange between grid service providers and DERs. The goal of the ESI is to encourage large-scale participation of DERs in order to provide grid services through dispatch of DER aggregations. This position paper also presents an open smart energy communications protocol that allows DERs to advertise their characteristics and participate in grid services, within constraints established by the ESI. The paper presents several monetization incentives that grid service providers could use to encourage large-scale DER participation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Understanding the Shift of Drivers of Soil Erosion and Sedimentation Based on Regional Process-Based Modeling in the Mississippi River Basin During the Past Century

Soil erosion and sedimentation problems remain a major water quality concern for making watershed management policies in the Mississippi River Basin (MRB). It is unclear whether the observed decreasing trend of stream suspended sediment loading to the mouth of the MRB over the last eight decades truly reflects a decline in upland soil erosion in this large basin. Here, for this work, we improved a distributed regional land surface model, the Dynamic Land Ecosystem Model, to evaluate how climate and land use changes have impacted soil erosion and sediment yield over the entire MRB during the past century. Model results indicate that total sediment yield significantly increased during 1980–2018, despite no significant increase in annual precipitation and runoff. The increased soil erosion and sediment yield are mainly driven by intensified extreme precipitation (EP). Spatially, we found notable intensified EP events in the cropland-dominated Midwest region, resulting in a substantial increase in soil erosion and sediment yield. Land use change played a critical role in determining sediment yield from the 1910s to the 1930s, thereafter, climate variability increasingly became the dominant driver of soil erosion, which peaked in the 2010s. This study highlights the increasing influences of extreme climate in affecting soil erosion and sedimentation, thus, water quality. Therefore, existing forest and cropland Best Management Practices should be revisited to confront the impacts of climate change on water quality in the MRB.

54 ENVIRONMENTAL SCIENCES↗

Evolution of Energy Efficiency Programs Over Time: The Case of Standby Power

Issued in 2001, Presidential Executive Order 13221 directed federal agencies to purchase products with low standby power, with the goal of 1) reducing energy consumption in federal facilities, and 2) drawing attention to the problem of high standby power consumption, with guidance provided by the Federal Energy Management Program (FEMP). At that time, standby power was newly recognized as an increasing building energy load. Since then, procurement of products with low standby power have been set in place in acquisition processes, and the purchasing power of the federal government continues to influence manufacturers’ design decisions related to standby power. In recent years, FEMP has shifted effort from direct manufacturer outreach for data collection, to integrating low standby requirement into broader acquisition programs including Energy Star and Electronic Product Environmental Assessment Tool (EPEAT). Another milestone has been the labeling of low standby products on the GSA Advantage website to simplify and enhance compliance. Looking forward into the program’s future, this question arises “How do we design programs over time to reflect market and technology changes, by adjusting programmatic requirements while maintaining effectiveness?” This paper discusses that question for the case of standby power, which transitioned from covering a single to multiple environmental attributes, both in the context of the program’s past and future.

Payne, CT↗

Sensitivity measurements for a 250 MHz quartz shear-horizontal surface acoustic wave biosensor under liquid viscous loading

Surface acoustic wave (SAW) devices have been used in biochemical assays due to their high sensitivity. The device sensitivity is a function of changes in the density and viscosity of the liquid. Here, we studied the effect of fluid viscosity using a 250 MHz quartz shear-horizontal (SH)-SAW biosensor by monitoring different concentrations of binary aqueous/glycerol solutions. In this study, the sensitivity of the biosensor was determined by fitting the data to models derived from perturbation theory. Measurements in water were used as the reference. For a 0% to 50% glycerol solution, an 87°–204° separation in the phase shift was observed. The slope of the plot of the phase shift vs (ηρ)0.5 was used to indicate the sensor’s sensitivity. The sensitivity for our 250 MHz quartz SH-SAW sensors was calculated to be 3.7×10−3m2sKg. The corresponding mass sensitivity was determined to be 9.25 × 105m2Kg. The limit of detection was calculated to be 36 picograms (pg), while the limit of quantification or LOQ was calculated to be 109 pg. Traditionally, liquid phase measurements have been challenging for SAW devices because liquids dampen the vibrating sensors severely. This problem has been largely solved using a transverse (shear) wave instead of the more popular longitudinal or Rayleigh waves. Liquid measurements are now possible using transverse waves, also known as shear waves, because transverse waves are only minimally attenuated by liquids. Shear-horizontal SAW sensors (SH-SAW) show great promise as label-free biosensors because of their ability to handle liquid samples. However, the viscosity of the liquid still induces loading effects and can be measured when the liquid is loaded onto the SH-SAW propagating surface (delay line). When the liquid above the delay line is perturbed by physical or chemical changes, such as binding to a receptor, it alters the propagating acoustic wave. The SH-SAW device can measure these changes in liquid properties as a change in the wave’s phase compared to the original wave. The device’s phase shift was recorded as a function of the changes in the density and viscosity of the binary glycerol solution and used to determine the sensitivity in the linear dynamic range of responses.

Materials Science↗

Si Microwire-Array Photocathodes Decorated with Cu Allow CO 2 Reduction with Minimal Parasitic Absorption of Sunlight

High loadings of Cu were integrated on the light-facing side of Si microwire arrays used under simulated sunlight for the photoelectrochemical reduction of CO 2 (aq) to hydrocarbons in 0.10 M KHCO 3 (aq). Radial-junction n + p-Si microwire arrays decorated with Cu exhibited absolute photocurrent densities comparable to an uncovered Si surface. Moreover, with respect to a Cu foil electrode, the positive shift in the onset potential for hydrocarbon formation at n + p-Si/Cu microwire arrays was equal to or greater than the photovoltage of the semiconductor alone. Selective electrodeposition of Cu on the tips and sidewalls of Si microwires was responsible for the minimal parasitic reflection and absorption exhibited by the catalyst, such that light-limited, absolute current densities >25 mA·cm –2 were sustained for 48 h under simulated sunlight. Photoelectrodes prepared from semiconductors with low diode quality factors and electrocatalysts with large Tafel slopes are shown to benefit from increased microstructured surface area. Si microwire arrays are thus suitable for photoelectrochemical reactions requiring high loadings of metallic and reflective electrocatalysts.

25 ENERGY STORAGE↗

Time-temperature-stress superposition of PBX 9502 compressive creep data for lifetime predictions

The plastic-bonded explosive (PBX) 9502 is a viscoelastic, high-solids loaded polymer bound composite comprised of 95 weight% (wt%) TATB explosive crystals and 5 wt% FK-800 polymer binder. The uniaxial quasi-static mechanical properties have been studied and characterized extensively over 25+ years, including creep. Creep is the strain evolution over time as a result of an asymmetric load typically at temperatures above ambient. Creep measurements to failure can take excessively long periods of time depending on various factors including applied stress, temperature, and loading rate that render a single test to failure impossible. Using the principles of time-temperature-stress superposition (TTSSP), short-term creep tests at various applied stresses and temperatures can be used for long-term creep predictions. The TTSSP model shifts short-term test data using two factors, one for temperature and stress, creating a master curve at a reference test condition. The master curve can be shifted to predict the creep response at any desired test condition. PBX 9502 compression specimens were tested at three temperatures and various applied stresses. This work discusses the TTSSP analysis of PBX 9502 compressive creep data to create a single comprehensive master curve.

36 MATERIALS SCIENCE↗

Analysis of Double-Output CLL Resonant Converter for All-Electric UAV Applications

This paper presents a double-output resonant converter with high-frequency isolation for unmanned aerial vehicle (UAV) applications. The proposed topology is developed by using a full-bridge resonant inverter and double-output half-bridge active rectifiers. For the control system, a phase-shifted pulse width modulation (PS-PWM) method is utilized to adjusts the power flow among the output rectifiers in a wide voltage range regulation with a central control. The theoretical analysis of the converter is explored using the system model under different load conditions with constant frequency. The proposed system is validated with experimental results using 60 V input source and generating 0 - 100 V in each output at a full power of 500 W with 96% maximum efficiency in the laboratory experimental setup.

Asa, Erdem↗