Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Resilience-Oriented DG Siting and Sizing Considering Stochastic Scenario Reduction

In this paper, a fuel-based distributed generator (DG) allocation strategy is proposed to enhance the distribution system resilience against extreme weather. The long-term planning problem is formulated as a two-stage stochastic mixed-integer programming (SMIP). The first stage is to make decisions of DG siting and sizing under the given budget constraint. In the second stage, a post-extreme-event-restoration (PEER) is employed to minimize the operating cost in an uncertain fault scenario. In particular, this study proposes a method to select the most representative scenarios for the SMIP. First, a Monte Carlo Simulation (MCS) is introduced to generate sufficient scenarios considering random fault locations and load profiles. Then, the number of scenarios is reduced by the K-means clustering algorithm. The advantage of scenario reduction is to make a trade-off between accuracy and computational efficiency. Finally, the SMIP is solved by the progressive hedging algorithm. Here, the case studies of the IEEE 33-bus and 123-bus test systems demonstrate the effectiveness of the proposed algorithm in reducing the expected energy not served (EENS), which is a critical criterion of resilience.

42 ENGINEERING↗

Optimal Design of Intensified Towers for CO2 Capture with Internal, Printed Heat Exchangers

Solvent-based carbon capture processes typically suffer from the temperature rise of the solvent due to the heat of absorption of CO2. This increased temperature is not thermodynamically favor-able and results in a significant reduction in performance in the absorber column. As opposed to interstage coolers, which only remove, cool, and return the solvent at discrete locations in the column, internal coolers that are integrated with the packing can cool the process inline, which can result in improved efficiency. This work presents the modeling of these internal coolers within an existing generic, equation-oriented absorber column model that can cool the process while allowing for simultaneous mass transfer. Optimization of this model is also performed, which is capable of optimally choosing the best locations to place these devices, such that heat removal and mass transfer area are balanced. Results of the optimization have shown that optimally placed cooling elements result in a significant increase in the capture efficiency of the process, compared to a similar column with no internal cooling, with a common trend being the cooling of the column in the temperature bulge region. It is observed that by optimally placing an internal cooler, the solvent flow rate can be decreased, and the CO2 lean loading can be increased while still maintaining the same efficiency. These process changes can lead to a substantial reduction in costs due to lower reboiler duty.

Summits, Stephen↗

An analytical method for identifying synergies between behind-the-meter battery and thermal energy storage

Electric utilities build generation capacity to meet the highest demand period, and they often pass on the costs associated with these peaking generators to building owners through demand charges. Building owners can minimize these demand charges by shifting energy use away from peak periods with behind-the-meter storage. This storage can include batteries, which can directly shift the metered load, or thermal energy storage, which can shift thermal-driven electric loads like air conditioning. However, there is a lack of research on how best to combine battery and thermal energy storage. In this study, we develop an analytical sizing method to calculate the potential demand reduction and annualized cost savings for different combinations of thermal and battery energy storage sizes. We show that adding batteries to a thermal energy storage system can increase the total system's load shaving potential. This is particularly true when the building has onsite photovoltaic generation or electric vehicle charging, which add significant variability to the load shape. We also show that for a given total storage size, selecting a higher fraction of thermal energy storage can significantly lower the cycling of the battery, and therefore extend the battery life. This, combined with the expected lower first cost of thermal energy storage materials compared to batteries, shows that hybrid energy storage systems can outperform a standalone battery or standalone thermal storage system. Assuming the thermal storage has a capital cost 6x lower than the battery, our analysis shows that the optimal system is 71% thermal energy storage and 29% battery energy storage for a scenario with electric vehicle charging. The annualized cost savings for this system are $48.6 k/yr, whereas an equivalently sized standalone thermal energy storage system would provide annualized cost savings of $28.5 k/yr and a standalone battery would lead to savings of $8.72 k/yr. The hybrid system also reduces battery cycling by 52% compared to a standalone battery, extending battery lifetime.

25 ENERGY STORAGE↗

The role of the Pt-group dehydrogenation catalyst in alkane metathesis for polyolefin deconstruction

Recent proposed approaches in the depolymerization of waste plastics employ an olefin intermediate to produce alkanes or alkenes using olefin metathesis in tandem chemistry. Here, in this study, we investigated the role of the dehydrogenation catalyst on reaction rate, kinetics, and product distribution in heterogeneous tandem dehydrogenation and olefin metathesis (alkane metathesis) of three different alkane reactants, including polyethylene. We found that many properties to which alkane dehydrogenation rates were sensitive-including metal composition, nanoparticle size, and surface doping of Re species also controlled activity in Tandem D/OM. When comparing Pd, Pt, and Pt 3 Sn 1 , supported Pd in tandem with a Re 2 O 7 olefin metathesis catalyst showed four-fold higher activity (surface area basis) compared to Pt or Pt 3 Sn 1 catalysts on the same support, mainly due to differences in the rate of hydrogenation. Catalyst preparation resulted in metal nanoparticles partially covered by ReO x , as seen from elemental mapping. Co-location of Re 2 O 7 and Pd correlated with increased rates of hydrogenation (i.e., an increase in the rate of alkane formation and simultaneous lowering of the rate of alkene formation), with a reaction order in catalyst study that further supported this conclusion. The Pd and Re 2 O 7 system displayed marked improvement compared to Pt or Pt 3 Sn 1 with Re 2 O 7 , and previous work, in the depolymerization rate of a linear polyethylene feedstock, with over 94 % reduction in polymer molecular weight in 15 h at 190 °C using less catalyst and increased reactant loadings, while keeping solvent to polymer consumption below 2.5.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultrafast x-ray diffraction of high-pressure phases in dynamically compressed TiO 2

Here, we investigate the high-pressure polymorphism of Ti⁢O 2 under laser-shock compression from 54(5) to 137(7) GPa using in situ femtosecond x-ray diffraction. Our results provide experimental evidence of the 𝑃⁢𝑐⁢𝑎⁢2 1 -type distorted fluorite structure formed from polycrystalline Ti⁢O 2 dynamically compressed to 54(5) GPa. Upon higher compression, we observe the direct formation of the ninefold coordinated F⁡e 2 ⁢P-type phase at 68(4) and 78(3) GPa in polycrystalline and [001]-oriented Ti⁢O 2 , respectively. This represents an unprecedented 100 GPa reduction in the shock synthesis pressure of the F⁡e 2⁢ P-type structure relative to quasihydrostatic loading conditions. On pressure release, the F⁡e 2⁢ P-type phase transforms to the α-Pb⁢O 2 structure and, at later times, reverts to rutile. Thus, the rutile →F⁡e 2⁢ P and α-Pb⁢O 2 →rutile transformations are both observed to occur on nanosecond timescales. Our results highlight the unique ability of high-strain-rate uniaxial compression to synthesize novel high-pressure phases and also indicate the importance of in situ atomic-level probes in developing pressure-temperature phase diagrams.

Crystal structures↗

Characterizing electrical demand and load diversity of low-power water and space heating appliances in US homes

Home renovation and remodeling projects can involve costly and time consuming electrical infrastructure upgrades at the household level. From the grid perspective they also lead to costly replacement of local infrastructure, such as transformers, and can add stress to the grid at peak times. The emergence of innovative, power-efficient household appliances offers a way to minimize these problems. These appliances are designed for lower power consumption, simplifying installation through standard plug-in connections, reducing the need for new electric circuits/panels/service, and minimizing the peak power demand for the home. Key examples include low-power heat pump water heaters (HPWHs) and cold climate window heat pumps that operate on standard 120V outlets. To assess the real-world impact of these solutions, we compiled and analyzed power metering data from several US field studies. This data provides insights into the effects on peak power demand of selecting lower-power appliances. Our analysis focuses on several key metrics, including the maximum power demand of individual appliances, their operational runtime, continuous operation and load diversity. While individual low-power 120V space and water heating appliances offer significant peak demand reductions compared to 240V heat pump or resistance alternatives, their longer runtimes might increase the likelihood of operation during whole-dwelling peak events, albeit at lower power levels.

Less, Brennan↗

Grid Planning for Building Electrification: A Report by the Energy Systems Integration Group’s Grid Planning for Building Electrification Task Force

The increased electrification of buildings across the United States is being driven by technical advancements, cost reductions for some building technologies, consumer preferences, and policy goals for decarbonization. However, the effects of this load growth on the electric distribution system are often only a minor consideration in policymaking and long-term planning studies. The long lead time and useful life of power system equipment means that the decisions taken today are expected to support our society well into the 2060s and beyond. Distribution planning stakeholders can take steps today to establish a grid foundation that captures the new challenges presented by building electrification. This report focuses on building electrification for the residential and commercial sectors, focusing most heavily on space heating, as this end use stands to most strongly impact demand.1 Across all end uses, building electrification could require somewhere between 10% and 70% more electricity generation capacity than exists today depending on technology adoption and energy efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

FPGA-accelerated SpeckleNN with SNL for real-time X-ray single-particle imaging

We present the implementation of a specialized version of our previously published unified embedding model, SpeckleNN, for real-time speckle pattern classification in X-ray Single-Particle Imaging (SPI), using the SLAC Neural Network Library (SNL) on an FPGA platform. This hardware realization transitions SpeckleNN from a prototypic model into a practical edge solution, optimized for running inference near the detector in high-throughput X-ray free-electron laser (XFEL) facilities, such as those found at the Linac Coherent Light Source (LCLS). To address the resource constraints inherent in FPGAs, we developed a more specialized version of SpeckleNN. The original model, which was designed for broader classification across multiple biological samples, comprised ~5.6 million parameters. The new implementation, while reducing the parameter count to 64.6K (a 98.8% reduction), focuses on maintaining the model's essential functionality for real-time operation, achieving an accuracy of 90%. Furthermore, we compressed the latent space from 128 to 50 dimensions. This implementation was demonstrated on the KCU1500 FPGA board, utilizing 71% of available DSPs, 75% of LUTs, and 48% of FFs, with an average power consumption of 9.4W according to the Vivado post-implementation report. The FPGA performed inference on a single image with a latency of 45.015 microseconds at a 200 MHz clock rate. In comparison, running the same inference on an NVIDIA A100 GPU resulted in an average power consumption of ~73W and an image processing latency of around 400 microseconds. Our FPGA-accelerated version of SpeckleNN demonstrated significant improvements, achieving an 8.9 × speedup and a 7.8 × reduction in power consumption compared to the GPU implementation. Key advancements include model specialization and dynamic weight loading through SNL, which eliminates the need for time-consuming FPGA design re-synthesis, allowing fast and continuous deployment of models (re)trained online. These innovations enable real-time adaptive classification and efficient vetoing of speckle patterns, making SpeckleNN more suited for deployment in XFEL facilities. This implementation has the potential to significantly accelerate SPI experiments and enhance adaptability to evolving experimental conditions.

47 OTHER INSTRUMENTATION↗

Grey-box modeling and application for building energy simulations - A critical review

Grey-box modeling, as one of the three fundamental modeling techniques for building energy models, has many advantages compared with black-box modeling and white-box modeling. Additionally, it has been widely applied to solve problems of building technologies, such as building load estimation, control and optimization, and building-grid integration. However, a thorough review of grey-box modeling is not available. This review study systematically investigated various aspects of grey-box modeling for buildings. First, the fundamental aspects of grey-box modeling are presented, including the theoretical background, modeling of building elements, modeling order, modeling diagram, and order reduction. Second, the detailed modeling approaches are discussed. Third, multiple applications of grey-box modeling are investigated for building energy domain, which are categorized into the following groups: heat dynamics analysis, thermal load estimation, building control and optimization, district/urban scale energy modeling, and building-grid integration. Finally, the available software packages for grey-box modeling are compared. Overall, the challenges of using grey-box modeling can be summarized as follows: (1) the theoretical limitations and assumptions of grey-box modeling are unclear; (2) grey-box model naming convention and structure are confusing; (3) grey-box model creation is vague; (4) suitable applications of grey-box models are unknown; and (5) grey-box models lack unified software solutions for wider adoption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sulfurized Polyacrylonitrile for High-Performance Lithium–Sulfur Batteries: In-Depth Computational Approach Revealing Multiple Sulfur’s Reduction Pathways and Hidden Li + Storage Mechanisms for Extra Discharge Capacity

Like no other sulfur host material, polyacrylonitrile-derived sulfurized carbon (SPAN) promises improved electrochemical performance for lithium–sulfur batteries, based on its compatibility with carbonate solvents and ability to prevent self-discharge and shuttle effect. However, a complete understanding of the SPAN’s lithiation mechanism is still missing because its structural features vary widely with synthesis conditions, and its electrochemical performance deviates from elemental sulfur. This study continues our research on the elucidation of the SPAN’s structural characteristics and lithiation mechanisms via computational approaches. Here, our models reproduce most experimental data regarding carbon’s graphitization level and conjugated ordering, sulfur–carbon covalent bonding, sulfur loading, and elemental composition. Our simulations emulate the discharge voltage observed in experiments for the first discharge, which reveals that sulfur follows multiple reduction pathways based on its interaction with the carbon backbone. Sulfur reduction takes place above 1.0 V vs Li/Li + mostly in the SPAN-like material, with no long-chain lithium polysulfide formation. Below 1.0 V vs Li/Li + , the backbone’s electrochemical activity occurs via multiple C–Li and N–Li interactions, mostly with edge carbon atoms and pyridinic nitrogen. Moreover, we identify Li + binding sites throughout the graphitized backbone that might lead to prohibited energy costs for Li + deintercalation, which may explain the irreversible capacity loss between the first and second discharges. This work improves understanding of lithiation mechanisms in sulfurized carbon, which is useful for rationally designing SPAN synthesis pathways tailored to increase sulfur loading and enhanced electrochemical performance.

25 ENERGY STORAGE↗

Highly durable fuel cell electrocatalyst with low-loading Pt-Co nanoparticles dispersed over single-atom Pt-Co-N-Graphene nanofiber

The limited durability of Pt electrocatalysis toward cathodic oxygen reduction reaction remains challenging, yet crucial for the development of Proton Exchange Membrane Fuel Cell. Here, we present a rational design of a robust catalyst consisting of PtCo nanoparticles supported on Pt-Co-N-graphene nanofiber prepared through electrospun Cobalt-Metal-Organic-Framework. The catalyst delivers unprecedented mass activity of 2.48 A·mgPt -1 , and retains 80% of initial value after 60,000 Accelerated-Stress-Test cycles. Operando X-ray absorption spectroscopies show that the electronic configurations of Pt sites in PtCo and Co sites in Co-N4 in the hybrid catalyst are modified toward high catalytic activities. Density Functional Theory unveils that the enhanced curvature of the substrate induced by the morphology engineering lowers the reaction thermodynamic barrier on Co-N4 sites, favoring the formation of H2O and suppressing that of H2O2. This result along with the strong affinity of PtCo nanoparticles to the Pt-Co-N-graphene fiber endows the catalyst an exceptional durability.

acidic electrolyte↗

High Solids Performance Testing in a Scaled TSCR System

The Tank Side Cesium Removal (TSCR) project is a technology demonstration that will pretreat Hanford tank waste supernatant in support of the Direct Feed Low-Activity Waste (DFLAW) mission. The TSCR system employs two key separation technologies: dead-end filtration (DEF) and ion exchange (IX) using crystalline silicotitanate (CST) media. DEF will be used to remove undissolved solids from tank waste to protect the functionality of the IX columns and the IX system will remove Cs-137 from tank waste. The separation technologies (DEF and IX) used in TSCR are technically mature and have also been successfully deployed at the Savannah River site in a similar facility known as the Tank Closure Cesium Removal (TCCR) system. While testing with simulants and real waste has been successfully performed under conditions expected during the initial operation of TSCR, test data is absent for assessing off normal high solids loading that may be in the TSCR waste feed. Normal TSCR treatment operations are expected to handle wastes with solids content on the order of 200 ppm, and off normal solids loading could be much larger than the nominal level. The testing program described in this report was conducted to understand the consequence of operating the TSCR system at elevated solids loadings up to the high-solids limit of 15,000 ppm [i.e., 1.5-wt%] identified in the TSCR design basis. Although the system is not required to make throughput above the nominal solids loading, the testing was intended to provide important information related to potential off normal operations. At off normal levels near the high-solids limit, there are potential implications for TSCR performance in the areas of throughput, DEF pressure drop, filter backflush frequency, and IX column pressure drop. In addition, intrusion of solids into the IX column was postulated to impact the Cs-137 loading behavior by promoting channeling or flow maldistribution in the column; since the magnitude of the postulated effect was unknown, assessing it was also of interest. The testing was performed using representative waste simulants and a prototypic, integrated TSCR system designed and assembled specifically to conduct the high solids performance assessment. Overall, the scaled TSCR testing demonstrated that full-scale unit operations can succeed in fulfilling their processing objectives in the presence of solids up to 3,000 ppm, but there are potential performance challenges to filtration operations at solids loadings as low as ~500 ppm. The severity of the challenge is likely to be dependent on the type and size distribution of solids, of which the current testing only examined a single type and size distribution. To provide some flexibility for future full-scale operations, the results of the testing suggest two possible risk reduction strategies that can be implemented without any changes in TSCR design or configuration. One option would be to enact an administrative limit on the solids loading to protect TSCR from feeds that are likely to require a high DEF swap frequency. Another option is to permit operation of the DEFs at differential pressures greater than 2 psid before swapping filters. The selection of a higher differential pressure target is not anticipated to adversely impact DEF backflushing efficacy and would reduce both swap frequency and the amount of waste sent to AP-108.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Codisposal Waste Package Loading Options for DOE SNF and HLW

The U.S. Department of Energy (DOE) is responsible for managing spent nuclear fuel (SNF) that is currently in, or will in the future come into, its possession. DOE must continue to safely store that SNF, transport it to an interim storage site or a repository, and dispose of it. These fuels come from a wide range of reactor types, such as light- and heavy-water-moderated reactors, graphite-moderated reactors, and breeder reactors, with various cladding materials and enrichments. Many of these reactors, now decommissioned, had unique design features, such as core configuration, fuel element and assembly geometry, moderator and coolant materials, operational characteristics, and neutron spatial and spectral properties resulting in a large diversity of reactor and fuel designs. Because of the wide variety and condition of SNF, a robust canister termed the DOE Standardized SNF Canister was proposed that would confine radionuclides and preclude moderator. The DOE Standard SNF Canister had four variations consisting of a 10- or 15-foot length and an 18- or 24-inch diameter. For ultimate disposal in the Yucca Mountain Repository these canisters were to be grouped with 24-inch diameter HLW canisters in a codisposal waste package. The 18-inch DOE Standardized SNF Canister could be placed in the middle of five HLW canisters. The 24-inch DOE Standardized SNF Canister would take the place of one the five HLW canister on the outer ring in the codisposal waste package. No DOE Standardized SNF Canisters have been loaded, and many fuel types can be loaded in multiple canisters. Depending on the selected diameter of the DOE Standardized SNF Canister for a particular fuel, the number of potential codisposal waste packages could vary. In addition, different types of DOE SNF may be able to be combined in a single canister. This could significantly change the number of DOE SNF canisters that are loaded and result in a decrease of the number of total potential codisposal waste packages. Ultimately, if too many HLW canisters need disposition, then a reduction in the number of DOE Standardized SNF Canisters will change the final total of codisposal waste packages very little. Likewise, if the ratio of DOE Standardized SNF Canisters to HLW canister produced is too high, then DOE Standardized SNF Canisters will not have enough HLW canisters to surround them in the codisposal waste package. This paper examines the results of differing loading strategies for a few DOE SNFs. It also compares the ranges of DOE Standardized SNF Canisters that may be produced to the ranges of HLW canisters that may be produced in order to determine potential scenarios.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hierarchical multi-time-scale predictive thermal management and fuel optimization for heavy-duty compression ignition engines

For heavy-duty diesel engines, NO X emissions reduction is strongly constrained by fuel efficiency. This paper presents a hierarchical model predictive controller (H-MPC) for coordinated control of tailpipe NO X emissions and fuel consumption. The H-MPC uses the separation of slow and fast dynamics that exist in the engine and its aftertreatment system. The controller is synthesized with an architecture in which a high-level MPC uses a longer prediction horizon compared to the low-level predictive controller which tracks the high-level controller command and manages the thermal dynamics of the aftertreatment system. Engine load preview enables the high-level controller to estimate the desired catalyst temperature ahead of time and addresses the selective catalytic reduction (SCR) slow thermal dynamics. Calculated by the high-level controller, the intake manifold pressure, and the start of injection (SOI) crank angle is used as reference trajectories in the low-level controller that regulates fast dynamical behaviors such as engine out NO X emissions. Hardware-in-the-loop (HIL) validation of this integrated H-MPC on a rapid prototype controller shows that when the SCR catalyst temperature is above light-off temperature (warmed-up condition), the engine operation is shifted to operate with the best fuel economy since the warmed-up SCR can efficiently reduce the engine-out NO X emissions. Results indicate that up to 0.8% benefit in cycle averaged BSFC along with a 13% reduction in tailpipe NO X compared to a stock engine calibration can be achieved with the coordinated engine and aftertreatment system through H-MPC.

Engineering↗

Fatigue performance of the Deeply Embedded Ring Anchor

Existing anchor solutions are limited in their applicability to the floating offshore wind industry, which demands prolonged load endurance in extreme weather conditions and varied seabed soils. This limitation restricts project feasibility and increases costs. In order to address these challenges, the Deeply Embedded Ring Anchor (DERA) is proposed to achieve substantial reductions in anchor costs through efficiency enhancements. Ensuring the long-term safety and reliability of the DERA, especially considering a minimum operational period of 25 years, necessitates a comprehensive understanding of fatigue damage. Induced by repetitive loading below material yield strength, fatigue poses a significant threat to structures exposed to waves and currents. Anchors, vital for station keeping, are susceptible to fatigue damage, particularly in the padeye area. This paper conducts a fatigue analysis, focusing on factors such as the wall thickness of the ring anchor, inner stiffeners, and stiffener thickness, to evaluate the performance of DERA in this context. The results showed that the stiffener significantly affects the elongation of the total life of the anchor. In conclusion, this paper focuses on advancing innovations like DERA, enabling the efficient utilization of offshore wind resources, and addressing safety concerns through meticulous fatigue analysis.

17 WIND ENERGY↗

On Road vs. Off Road Low Load Cycle Comparison

Reducing criteria pollutants while reducing greenhouse gases is an active area of research for commercial on-road vehicles as well as for off-road machines. The heavy duty on-road sector has moved to reducing NOx by 82.5% compared to 2010 regulations while increasing the engine useful life from 435,000 to 650,000 miles by 2027 in the United States (US). An additional certification cycle, the Low Load Cycle (LLC), has been added focusing on part load operation having tight NOx emissions levels. In addition to NOx, the total CO2 emissions from the vehicle will also be reduced for various model years. The off-road market is following with a 90% NOx reduction target compared to Tier 4 Final for 130-560 kW engines along with greenhouse gas targets that are still being established. The off-road market will also need to certify with a Low Load Application Cycle (LLAC), a version of which was proposed for evaluation in 2021. Since the LLAC has not been finalized, this study is being conducted to compare and contrast the LLC for on-road with the LLAC for off-road as there might be some shared learnings. A US off-road production 2023 Fiat Powertrain 13L engine and aftertreatment system was chosen for this work. This engine is used in production for both off-road and on-road products, so it is a good choice for this study. The associated off-road aftertreatment system was aged for more relevant comparisons. The engine calibration was not altered for either of the low load cycles. This study shows that the cycles are quite different in nature as the market needs are different. The LLC includes a large fraction of operation at idle and lower speeds, representing products that use the engine primarily for motive power, where lower vehicle speed means a lower engine speed and load. The LLAC has more time and load spent at high speeds and slightly higher loads. The off-road products represented by this cycle often use the engine to drive auxiliary equipment which means higher parasitic loads and hand/fixed throttle. The comparison will include the use profiles, tailpipe NOx and greenhouse gas emissions (CO2, N2O).

McCarthy, James↗

Composite biopolymer electrolytes for high-performance reversible zinc-air batteries

Zinc-air batteries (ZABs) are regarded as one of the most promising candidates for next-generation energy storage systems due to their inherent safety, high energy density, and low cost. In this study, we optimized the composition of gel polymer electrolytes (GPEs), which play a crucial role in enhancing ZAB reversibility due to their water retention capabilities. The GPEs are synthesized using a combination of polyacrylic acid (PAA), polyacrylamide (PAM), and biopolymer kappa-carrageenan (KC), with and without additional additives. Among these, the composite GPE containing KC, PAA, and PAM demonstrated superior ionic conductivity (6.68 mS/cm at 30 °C) and enhanced water retention compared to the PAA–PAM-based GPE. Furthermore, this composite electrolyte operates within a wider electrochemical window of −1.0 V–2.2 V. A bifunctional catalyst, nickel–iron layered double hydroxide (NiFe-LDH), is electrochemically synthesized on a modified activated carbon cloth (CC). The catalyst loading is optimized based on oxygen evolution reaction (OER) performance, showing an overpotential of 555 mV. The oxygen reduction reaction (ORR) occurred at a half-wave potential of 0.620 V, which is lower than that of Pt/C (0.852 V), indicating better catalytic activity. The KC based cell exhibit better cycling stability than PAA–PAM-based GPE. The electrochemical performance of ZAB cells is evaluated under various atmospheres: ambient air and humid conditions and temperatures. Notably, in a humid environment, the cells achieved extended cycling stability, operating for over 500 h—significantly longer than under open-air conditions. Overall, this study highlights the importance of tailored GPE design and efficient bifunctional catalysts to enhance the performance and longevity of zinc-air batteries for long-duration energy storage applications.

Catalyst↗

End of Green Sahara amplified mid- to late Holocene megadroughts in mainland Southeast Asia

Between 5 and 4 thousand years ago, crippling megadroughts led to the disruption of ancient civilizations across parts of Africa and Asia, yet the extent of these climate extremes in mainland Southeast Asia (MSEA) has never been defined. This is despite archeological evidence showing a shift in human settlement patterns across the region during this period. We report evidence from stalagmite climate records indicating a major decrease of monsoon rainfall in MSEA during the mid- to late Holocene, coincident with African monsoon failure during the end of the Green Sahara. Through a set of modeling experiments, we show that reduced vegetation and increased dust loads during the Green Sahara termination shifted the Walker circulation eastward and cooled the Indian Ocean, causing a reduction in monsoon rainfall in MSEA. Our results indicate that vegetation-dust climate feedbacks from Sahara drying may have been the catalyst for societal shifts in MSEA via ocean-atmospheric teleconnections.

54 ENVIRONMENTAL SCIENCES↗