Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Capillary Pump Loop (CPL) heat pipe development status report

The capillary pump loop (CPL) was re-introduced as a potential candidate for the management of large heat loads. It is currently being evaluated for application in the thermal management of large space structures. Test efforts were conducted to establish the feasibility of the CPL heat pipe design.

Source record↗

Integrated Scalable Parallel Firewall and Intrusion Detection System for High-Speed Networks

This project developed a new scalable network firewall and Intrusion Protection System (IPS) that can manage increasing traffic loads, higher network speeds, and strict Quality of Service (QoS) requirements. This new approach provides a strong foundation for next-generation network security technologies and products that address growing and unmet needs in the government and corporate sectors by delivering Optimal Network Security. Controlling access is an essential task for securing networks that are vital to private industry, government agencies, and the military. This access can be granted or denied based on the packet header or payload contents. For example, a simple network firewall enforces a security policy by inspecting and filtering the packet headers. As a complement to the firewall, an Intrusion Detection System (IDS) inspects the packet payload for known threat signatures; for example, virus or worm. Similar to a firewall policy, IDS policies consist of multiple rules that specify an action for matching packets. Each rule can specify different items, such as the signature contents and the signature location within the payload. When the firewall and IDS are merged into one device, the resulting system is referred to as an Intrusion Protection System (IPS), which provides both packet header and payload inspections. Having both types of inspections is very desirable and more manageable in a single device.

97 MATHEMATICS AND COMPUTING↗

Techno-economic feasibility of borehole thermal energy storage system connected to geothermal heat pumps for seasonal heating load of two buildings in Fairbanks, Alaska

Borehole thermal energy storage (BTES) is an effective solution for managing imbalanced heating and cooling loads in cold regions. This study evaluated the long-term feasibility of a BTES system in the Fairbanks area, Alaska, through building energy modeling, resource characterization, and numerical modeling. The system was designed to store waste heat from a nearby coal power plant during summer and provide thermal energy during winter to geothermal heat pumps supplying heating loads in two buildings. Heating load profiles were modeled for the buildings using EnergyPlus, and the results indicated the annual heating load was 5.6 times greater than the cooling load. 40 borehole heat exchangers were pre-designed approximately 100 m away from the two buildings in terms of land availability and regulatorily optimized depth. The 20-year performance of the designed BTES system under two operational scenarios—one with a 5-year preheating period and one without—was numerically modeled using subsurface temperature and properties characterized through the literature review and thermal response tests. Both scenarios demonstrated that the BTES has the capacity to fully cover the heating loads in the two buildings throughout the 20-year lifetime. Production temperatures at central wells were 33 % higher on average than at outer wells in both scenarios. The 5-year preheating period increased subsurface and extraction temperatures, and correspondingly annual average and total thermal energy production was higher for 8 years than in the scenario without the preheating period. These results highlight the long-term reliability and sustainability of the BTES system in meeting heating demands over its lifetime, with the preheating period offering potential performance improvements. Implementing the BTES system in cold regions with high heating demand, such as Fairbanks, Alaska, could provide a long-term, sustainable energy solution for managing imbalanced heating and cooling loads.

15 GEOTHERMAL ENERGY↗

VersiCharge-SG - Smart Grid Capable Electric Vehicle Supply Equipment (EVSE) for Residential Applications

In his 2011 State of the Union address, President Obama called for one million electric vehicles on the road by 2015 [1]. With large-scale Electric Vehicle (EV) or Plug-in Electric Vehicle (PEV or EV for short) or Plug-in Hybrid Electric Vehicle (PHEV) penetration into the US market, there will be drastic reduction in fossil fuel consumption, thus significantly reducing our dependency on foreign oil [2-6]. There will also be significant reduction on Green House Gas (GHG) emissions and smog in the major US cities [3, 7, 8]. Similar studies have also been done other industrial counties [9]. For the fuel cost, with the home electricity rate around $0.13 per kWh, it would cost about $0.05 per mile for DC operation and $0.03 cents per mile for AC operation. But, assuming 25 miles per gallon for a typical vehicle and $4 per gallon, fossil fuel will cost $0.16 per mile [10]. The overall lifecycle cost of PEVs will be several folds lower than the existing fossil fueled vehicles. Despite the above advantages of the EVs, the current cost of EVSE is not affordable for the average consumer. Presently, the cost of installing state-of-the-art residential EVSE ranges from $1500 to $2500 [11]. Low priced EVSE technology, which is easy to install, and affordable to operate and maintain by an average consumer, is essential for the large-scale market penetration of EVs. In addition, the long-term success of this technology is contingent on the PEVs having minimal excessive load and shift impact on the grid, especially at peak times. In a report [2] published by the Pacific Northwest National Laboratory (PNNL), the exiting electric power generation infrastructure, if used at its full capacity 24 hours a day, would support up to 84% of the nation’s cars, pickup trucks and SUVs for an average daily drive of 33 miles. This mileage estimate is certainly much below what an average driver would drive his/her vehicle per day. Another report [3] by the National Renewable Energy Laboratory (NREL) shows that an increased PEV penetration would significantly increase pressure on the peak generation, if no controlled charging strategy was put in place. Investigations from Oak Ridge National Laboratory (ORNL) show that in many regions, additional power generation facilities must be put in place and operate in evening times to recharge the EVs [12]. By all accounts, large PEV penetration will bring to the power grid enormous challenges due to the excessive and stochastic demand, and can entirely change the peak time distribution and behavior, perhaps, into a bi-modal distribution capable of exhausting primary, secondary and even reserves (spinning or non-spinning). To minimize the infrastructure upgrade costs and risks to the grid, and to ensure that power quality and reliability remain within the set standards, the demand for EV plug-ins must then be controlled and coordinated locally and at regional levels. Novel control techniques must be devised to allow for close collaboration between neighboring plug-in requestors, between neighboring communities, and between these and more central power authorities. The concept of electric drive vehicle is not new. The development of electric vehicle has been around since 19th century [13]. But due to a number of reasons and practical limitations at the time, including lower cost of gasoline compared to electricity, excessive refueling times, and abundance of gasoline, the automobile industry embraced gasoline-powered vehicles worldwide [13]. With the global warming, ever reducing reservoirs of fossil oil around the world and increasing political pressure to reduce the national dependency on foreign oil, the last decade of the 20th century witnessed major technological breakthroughs in Alternative Fueled Vehicle (AFV) technologies, including electric vehicles. With GHG emissions and carbon footprint in the minds of many more consumers and politicians, the first decade of the 21stCentury witnessed more breakthroughs with some real life experimentation and sporadic deployment of these technologies [14]. By many accounts, the second decade of the 21st Century is expected to be the time when mass volume production and popular usage of these AFV technologies, especially EV, will materialize. The current DOE request for proposals recognizes the need for major technological changes to ensure that the above national goal is realizable. Two major challenges have been identified: (1) major reduction in the cost of ownership of EVSEs, and (2) managing additional EV loads in the power grid while maintaining power quality, reliability, and affordability. We note that the two challenges are closely linked – A holistic approach to true lifecycle cost of EVSE ownership will certainly include any taxes and surcharges that can be put in place for major potential investments in the grid, and higher electricity charges in case of more frequent and longer peak periods. From a societal perspective, this cost could also include the lost GDP (computed on a local basis) and revenue for businesses at local and regional levels when the grid is no longer capable of meeting the demand and unexpected outages occur. A typical end-point electrical distribution system delivers power to a residential EVSE from the neighborhood distribution pole, as shown in Fig.1. This pole has a transformer (neighboring step-down transformer) that steps down the utility medium voltage to dual 120VAC single phase (also called 240VAC split phase). This voltage is fed through a meter into the residential load control center. The load control center consists of branch circuit breakers and distributes the power supply within various areas of the residential unit. One of the branch circuits from the load control center feeds EV charging station for the unit. An electric vehicle charger is plugged into the socket of the EV charging station and other end of this charger is connected to the vehicle during charging. Figure 1 illustrates a typical configuration of the power grid. The left side of the figure shows the power grid from the power generation to the neighboring step-down transformer, while the right side of the figure shows multiple EVs with the respective charging stations. The typical step-down transformer has an upper limit representing the maximum load that can be requested from these neighboring houses altogether (typically 24 kW). In case the total load increases beyond the supported limit, the protection system (e.g. a circuit breaker) attached to the step-down transformer gets activated automatically.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of Additive Manufacturing Technologies for 3D Printing of Spacecraft Heat Shields

Introduction: Ablative heat shields are an enabling technology for entry into planetary atmospheres. From the PICA heatshields used for several Mars rovers to the carbon phenolic material used for Galileo’s Jupiter entry probe, the heat shield manages the heat load transferred to the payload, protecting the sensitive scientific instruments carried on entry probes. The Additive Manufacturing of Thermal Protection Systems (AMTPS) project, an Early Career Initiative (ECI) funded by NASA’s Space Technology Mission Directorate and led by NASA Johnson Space Center, seeks to develop materials and processes for 3D printing ablative heat shields for spacecraft. Current methods for producing ablative heat shields are extremely labor intensive and re-quire extensive hands-on processes and quality control characterization. Additive manufacturing (AM) offers the possibility of reduced production times, improved reliability, and enhanced performance via graded compositions. Costs will also be reduced by reducing the time and labor required for heat shield production. Direct integration of the heat shield onto the structure during processing simplifies integration and reduces risk. Material Development: A critical challenge for the project is development of a material system that can (1) be printed in a near-net shape process and (2) perform well as an ablator. Achieving printability requires the material to flow under applied pressure, but maintain its shape once extruded from the printer nozzle. Ablative performance is measured by a multitude of markers, including char yield, char strength, thermal conductivity, and recession rate. Furthermore, there are several mechanical and thermal property considerations for vehicle integration including coefficient of thermal expansion (CTE) and residual stress. AM technology will be leveraged to grade the material formulation and properties through the thickness of the heat shield, an architecture not possible with current manufacturing processes. To this end, “robust” material formulations have been pre-pared with higher density for use on the surface where most ablation will occur. “Insulative” material formulations, with lower density and lower thermal conductivity, are prepared for use in the depth of the heat shield. This graded architecture will re-duce the overall mass of the heat shield and reduce costs and/or increase scientific payload capacities. To achieve a material system with the required properties, multiple resins have been investigated in collaboration with NASA Ames Research Center. To tune printability and performance, resin additives were studied to improve flexibility of the cured material while maintaining acceptable ablative performance. Material coupons were printed and studied via a suite of mechanical and thermal characterization methods. Arc jet testing was conducted at NASA Ames Research Center to evaluate ablative performance and thermal protection under conditions expected in atmospheric entry. Manufacturing Scale-Up: A partnership with Oak Ridge National Laboratory (ORNL) aims to enable full-scale fabrication of a 3D printed heat shield. Leveraging expertise in manufacturing and 3D printing at ORNL, a mid-scale manufacturing demonstration unit will be built and tested, using a dual-layer ablative system printed directly onto the titanium structure. Work on robotic system integration is ongoing and efforts to scale up material mixing with a material compound will ensure accurate and homogenous composition. Flight Test: A hypersonic sub-orbital flight test will provide a rigorous test of material performance ranging from ablation, thermal management, and mechanical integrity. Design of the capsule has taken place in collaboration with the University of Kentucky. Data collected from the flight will inform future design efforts in material formulation, printing methodology, and heat shield-capsule integration.

additive manufacturing↗

Intracycle RPM control for vertical axis wind turbines

The wind energy market is currently dominated by horizontal axis wind turbines (HAWTs); however, vertical axis wind turbines (VAWTs) are emerging as a design alternative, especially for deep-water offshore siting due to their low center of gravity, ease of access to drivetrain components, and overall simplicity. Due to the absence of a pitch mechanism in large-scale Darrieus VAWTs, stall control has often been used to manage power and loads. Introducing a pitching mechanism in H-type VAWTs has been studied, but this diminishes the mechanical simplicity advantage, and the use of a pitching mechanism in a large-scale Darrieus-type VAWT is not practical. This work examines an innovative, alternative method to control the rotor dynamics of a large-scale 5 MW VAWT to maximize power while constraining loads without introducing any new or complex mechanical elements. This control strategy is termed intracycle revolution per minute (RPM) control, where the rotational speed of the turbine is allowed to vary in an optimal fashion with the azimuthal location of blades as opposed to typical constant RPM operation. An optimization framework is formulated for an open-loop optimal control problem and solved to maximize power subject to constraints on aerodynamic design loads. Results are presented to demonstrate the benefits and the performance limits of intracycle RPM control for large-scale 5 MW Darrieus VAWTs, namely, (1) power production (quantified in terms of AEP) that can be increased subject to baseline load limits and (2) opportunities to significantly increase AEP or decrease loads via intracycle RPM control that are examined for both two-bladed and three-bladed VAWTs.

17 WIND ENERGY↗

Status and performance of the GlueX DIRC

In support of the future physics program at Ce+BAF, we propose a prototype positron target. The prototype target consists of a tungsten disk mounted on a water-cooled copper support structure to enhance heat removal. The primary goals of this work are to benchmark CFD simulations, ensure vacuum integrity at the 10^-6 Pa level, achieve stable target rotation up to 10 Hz, and implement efficient water-based cooling for sustained high-power operation. To manage the thermal load, the target is designed to rotate, allowing the deposited heat to spread over a larger region, and thereby reducing localized thermal stress while maintaining the maximum temperature below 1000 K. To experimentally evaluate the thermal performance and structural stability of the target, we plan to conduct high-power laser heating tests at Laser Lab 5, LERF Building, JLab. These tests will serve as a stepping-stone for the positron production target at CEBAF.

Stevens, J.R. [College of William and Mary, Willia↗

Experimental demonstration and performance evaluation of a complex fenestration system for daylighting and thermal harvesting

Two significant design strategies for mitigating building energy consumption are daylight redirection and solar energy harvesting. Effective daylighting implementation enhances the amount of useful natural light within a space and offsets the need for electric lighting. Solar energy harvesting systems can mitigate energy costs from mechanical systems by managing incoming thermal loads or capturing solar energy that can be used to supplement thermal systems in the building. While there are many available façade-based technologies that can perform daylighting or solar thermal energy harvesting, there remains a limitation in available systems that can perform both of them simultaneously. This paper, describes the design and experimental demonstration of a Liquid Filled Prismatic Louver (LFPL) system, which combines both energy-saving strategies. The LFPL system was installed in a south-facing room in New York City and evaluated for indoor daylight penetration and potential for thermal energy harvesting. Daylight redirection is achieved through the prismatic louver geometry and proper orientation, whereas thermal energy harvesting is achieved through IR absorption from the liquid (e.g., water) within the prisms. Daylighting performance was evaluated by illuminance measurements at key locations within the space, whereas thermal harvesting performance was evaluated through temperature measurements and thermal imaging analysis. We show that the LFPL system, with all prismatic elements oriented at the same angle, achieve a 2-fold and 8-fold enhancement in daylight redirection to the ceiling, for prism orientations of 10° and 20°, respectively. We also demonstrate the system’s capability to adjust to specific lighting needs, within the space, through the dynamic individual orientation of prismatic elements; thus, achieving a concentrated ceiling illuminance enhancement of ~100 times and ~200 times at 2.5 and 4.3 m away from the window sill, providing workplane illuminance enhancement of 6 and 2 times more than in the case of the control room with regular windows. Furthermore, we illustrate a reduction of potential heating loads at locations close to the window from the combination of infrared absorption in the water volume and the redirection of the incoming solar radiation, leading to a reduction of the workplane temperature by an average of 7–10 °C.

14 SOLAR ENERGY↗

Environmental evaluation of municipal waste prevention

Highlights: > Influence of prevention on waste management systems, excluding avoided production, is relatively minor. > Influence of prevention on overall supply chain, including avoided production is very significant. > Higher relative benefits of prevention are observed in waste management systems relying mainly on landfills. - Abstract: Waste prevention has been addressed in the literature in terms of the social and behavioural aspects, but very little quantitative assessment exists of the environmental benefits. Our study evaluates the environmental consequences of waste prevention on waste management systems and on the wider society, using life-cycle thinking. The partial prevention of unsolicited mail, beverage packaging and food waste is tested for a 'High-tech' waste management system relying on high energy and material recovery and for a 'Low-tech' waste management system with less recycling and relying on landfilling. Prevention of 13% of the waste mass entering the waste management system generates a reduction of loads and savings in the waste management system for the different impacts categories; 45% net reduction for nutrient enrichment and 12% reduction for global warming potential. When expanding our system and including avoided production incurred by the prevention measures, large savings are observed (15-fold improvement for nutrient enrichment and 2-fold for global warming potential). Prevention of food waste has the highest environmental impact saving. Prevention generates relatively higher overall relative benefit for 'Low-tech' systems depending on landfilling. The paper provides clear evidence of the environmental benefits of waste prevention and has specific relevance in climate change mitigation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Realization of a gas puff imaging system on the Wendelstein 7-X stellarator

A system for studying the spatiotemporal dynamics of fluctuations in the boundary of the W7-X plasma using the “Gas-Puff Imaging” (GPI) technique has been designed, constructed, installed, and operated. This GPI system addresses a number of challenges specific to long-pulse superconducting devices, such as W7-X, including the long distance between the plasma and the vacuum vessel wall, the long distance between the plasma and diagnostic ports, the range of last closed flux surface (LCFS) locations for different magnetic configurations in W7-X, and management of heat loads on the system’s plasma-facing components. The system features a pair of “converging–diverging” nozzles for partially collimating the gas puffed locally ≈135 mm radially outboard of the plasma boundary, a pop-up turning mirror for viewing the gas puff emission from the side (which also acts as a shutter for the re-entrant vacuum window), and a high-throughput optical system that collects visible emission resulting from the interaction between the puffed gas and the plasma and directs it along a water-cooled re-entrant tube directly onto the 8 × 16 pixel detector array of the fast camera. The DEGAS 2 neutral code was used to simulate the Hα (656 nm) and HeI (587 nm) line emission expected from well-characterized gas-puffs of H2 and He and excited within typical edge plasma profiles in W7-X, thereby predicting line brightnesses used to reduce the risks associated with system sensitivity and placement of the field of view. Operation of GPI on W7-X shows excellent signal-to-noise ratios (>100 at 2 Mframes/s) over the field of view for minimally perturbing gas puffs. The GPI system provides detailed measurements of the two-dimensional (radial and poloidal) dynamics of plasma fluctuations in the W7-X edge and scrape-off layer and in and around the magnetic islands outside the LCFS that make up the island divertor configuration employed on W7-X.

Instruments & Instrumentation↗

How Can Probabilistic Solar Power Forecasts Be Used to Lower Costs and Improve Reliability in Power Spot Markets? A Review and Application to Flexiramp Requirements

Net load uncertainty in electricity spot markets is rapidly growing. There are five general approaches by which system operators and market participants can use probabilistic forecasts of wind, solar, and load to help manage this uncertainty. These include operator situation awareness, resource risk hedging, reserves procurement, definition of contingencies, and explicit stochastic optimization. We review these approaches, and then provide a case study in which a method for using probabilistic solar forecasts to define needs for reserves is developed and evaluated. The case study has three parts. First, we describe building blocks for enhancing the Watt-Sun solar forecasting system to produce probabilistic irradiance and power forecasts. Second, relationships between Watt-Sun forecasts for multiple sites in California and the system's need for flexible ramp capability (flexiramp) are defined by machine learning and statistical methods. Third, the performance of present methods to defining flexiramp requirements, which are not conditioned on weather and renewables forecasts, is compared with that of probabilistic solar forecast-based requirements, using a multi-timescale production costing model with an 1820-bus representation of the WECC power system. Significant potential savings in fuel and flexiramp procurement costs from using solar-informed reserve requirements are found.

14 SOLAR ENERGY↗

Optimal Energy Dispatch Controller for Fuel Cell-Integrated Multi-Zone Building

Stationary fuel cells provide potential opportunities for energy savings when integrated with buildings. Through smart dispatch of both electrical power and heat generated by the fuel cells and managing the building loads, the buildings can achieve more efficient operation. In this paper, we develop an optimal energy dispatch controller to operate a fuel cell-integrated building. The controller leverages the inherent thermal storage and the dispatchable fuel cell to reduce its operating cost and to allow the building to participate in grid services. The proposed controller is implemented on two types of commercial buildings, a large office building and a large hotel, and the effectiveness of the controller is demonstrated through simulations. The results also indicate that the potential saving varies significantly with different system parameters, including season, fuel prices, and equipment sizing, which provide helpful insights for building operators and other stake holders.

39 EE - Hydrogen and Fuel Cell Technologies (EE-3F↗

Smart Grid Enabled L2 EVSE for the Commercial Market

In 2011, the DOE issued Funding Opportunity DE-FOA-0000554 as a means of addressing two major task areas identified by the Grid Integration Tech Team (GITT) that would help transition Electric vehicles from a market driven by early adopters and environmental supporters to a market with mainstream volumes. Per DE-FOA-0000554, these tasks were: To reduce the cost of Electric Vehicle Supply Equipment (EVSE), thereby increasing the likelihood of the build out of EV charging infrastructure. The goal of increasing the number of EVSE available was to ease concerns over range anxiety, and promote the adoption of electric vehicles: To allow EV loads to be managed via the smart grid, thereby maintaining power quality, reliability and affordability, while protecting installed distribution equipment. In December of that year, the DOE awarded one of the two contracts targeted toward commercial EVSE to Eaton, and in early 2012, we began in earnest the process of developing a Smart Grid Enable L2 EVSE for the Commercial Market (hereafter known as the DOE Charger). The design of the Smart Grid Enabled L2 EVSE was based primarily on the FOA requirements along with input from the Electric Transportation Infrastructure product line (hereafter ETI) marketing team who aided in development of the customer requirements.

33 ADVANCED PROPULSION SYSTEMS↗

Transactive System: Part I: Theoretical Underpinnings of Payoff Functions, Control Decisions, Information Privacy, and Solution Concepts

The increased penetration of renewable energy has significantly changed the conditions and the operational timing of the electricity grid. More flexible, faster ramping resources are needed to compensate for the uncertainty and variability introduced by renewable energy. Distributed energy resources (DERs) such as distributed generators, energy storage, and controllable loads could help manage the power grid in terms of both economic efficiency and operational reliability. In order to realize the benefits of DERs, coordination and control approaches must be designed to enable seamless integration of DERs into the power grid. Transactive coordination and control is a new approach for DER integration, where individual resources are automated and engaged through market interaction. Transactive approaches use economic signals—prices or incentives—to engage DERs. These economic signals must reflect the true value of the DER contributions, so that they seamlessly and equitably compete for the opportunities that today are only available to grid-owned assets. Value signals must be communicated to the DERs in near-real time, the assets must be imbued with new forms of distributed intelligence and control to take advantage of the opportunities presented by these signals, and they must be capable of negotiating and transacting a range of market-driven energy services. The concepts of transactive energy systems are not new, but build upon evolutionary economic changes in financial and electric power markets. These concepts also recognize the different regional structures of wholesale power markets, electricity delivery markets, retail markets, and vertically integrated service provider markets. Although transactive energy systems are not revolutionary, they will be transformational in their ability to provide flexibility and operational efficiency. A main goal of this research is to establish useful foundation for analysis of transactive energy systems and to facilitate new transactive energy system design with demonstrable guarantees on stability and performance. Specifically, the goals are to (1) establish a theoretical basis for evaluating the performance of different transactive systems, (2) devise tools to address canonical problems that exemplify challenges and scenarios of transactive systems, and (3) provide guidelines for design of future transactive systems. This report, Part 1 of a two part series, advances the above-listed research objectives by reviewing existing transactive systems and identifying a theoretical foundation that integrates payoff functions, control decisions, information privacy, and mathematical solution concepts.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Transactive System: Part I: Theoretical Underpinnings of Payoff Functions, Control Decisions, Information Privacy, and Solution Concepts

The increased penetration of renewable energy has significantly changed the conditions and the operational timing of the electricity grid. More flexible, faster ramping resources are needed to compensate for the uncertainty and variability introduced by renewable energy. Distributed energy resources (DERs) such as distributed generators, energy storage, and controllable loads could help manage the power grid in terms of both economic efficiency and operational reliability. In order to realize the benefits of DERs, coordination and control approaches must be designed to enable seamless integration of DERs into the power grid. Transactive coordination and control is a new approach for DER integration, where individual resources are automated and engaged through market interaction. Transactive approaches use economic signals—prices or incentives—to engage DERs. These economic signals must reflect the true value of the DER contributions, so that they seamlessly and equitably compete for the opportunities that today are only available to grid-owned assets. Value signals must be communicated to the DERs in near-real time, the assets must be imbued with new forms of distributed intelligence and control to take advantage of the opportunities presented by these signals, and they must be capable of negotiating and transacting a range of market-driven energy services. The concepts of transactive energy systems are not new, but build upon evolutionary economic changes in financial and electric power markets. These concepts also recognize the different regional structures of wholesale power markets, electricity delivery markets, retail markets, and vertically integrated service provider markets. Although transactive energy systems are not revolutionary, they will be transformational in their ability to provide flexibility and operational efficiency. A main goal of this research is to establish useful foundation for analysis of transactive energy systems and to facilitate new transactive energy system design with demonstrable guarantees on stability and performance. Specifically, the goals are to (1) establish a theoretical basis for evaluating the performance of different transactive systems, (2) devise tools to address canonical problems that exemplify challenges and scenarios of transactive systems, and (3) provide guidelines for design of future transactive systems. This report, Part 1 of a two part series, advances the above-listed research objectives by reviewing existing transactive systems and identifying a theoretical foundation that integrates payoff functions, control decisions, information privacy, and mathematical solution concepts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Innovative Technologies for a Low Carbon Electricity System

The electricity sector represents the centerpiece of decarbonization pathways for the state. Decrease in the cost of renewable electricity generation, combined with ample solar energy, wind and other renewable resources, presents a realistic way to achieve electricity generation that is nearly free of CO 2 emissions by mid-century. Expansion of renewable electricity supply could allow replacement of many CO 2 -emitting technologies with ones that use electricity—in transportation, buildings, and possibly industry. Key elements of the path for California’s electricity sector are: restrain electricity demand through higher efficiency, rapidly expand renewable electricity generation, develop electricity storage to complement renewable electricity, manage flexible electricity loads for a low-carbon electricity system, electrify where appropriate to reduce CO 2 emissions, and maintain reliable and resilient electricity supply. This report provides an overview of a multitude of innovative technologies in each of the above areas that have the potential to help the state meet its decarbonization goals, while lowering costs and promoting greater reliability. The information presented provides a portrait of the landscape of technology innovation that can help policymakers, state agencies, and interested parties develop strategies to meet the state’s goals and to target efforts to support and nurture technology innovation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

LIFE Materials: Fuel Cycle and Repository Volume 11

The fusion-fission LIFE engine concept provides a path to a sustainable energy future based on safe, carbon-free nuclear power with minimal nuclear waste. The LIFE design ultimately offers many advantages over current and proposed nuclear energy technologies, and could well lead to a true worldwide nuclear energy renaissance. When compared with existing and other proposed future nuclear reactor designs, the LIFE engine exceeds alternatives in the most important measures of proliferation resistance and waste minimization. The engine needs no refueling during its lifetime. It requires no removal of fuel or fissile material generated in the LIFE engine. It leaves no weapons-attractive material at the end of life. Although there is certainly a need for additional work, all indications are that the 'back end' of the fuel cycle does not to raise any 'showstopper' issues for LIFE. Indeed, the LIFE concept has numerous benefits: (1) Per unit of electricity generated, LIFE engines would generate 20-30 times less waste (in terms of mass of heavy metal) requiring disposal in a HLW repository than does the current once-through fuel cycle. (2) Although there may be advanced fuel cycles that can compete with LIFE's low mass flow of heavy metal, all such systems require reprocessing, with attendant proliferation concerns; LIFE engines can do this without enrichment or reprocessing. Moreover, none of the advanced fuel cycles can match the low transuranic content of LIFE waste. (3) The specific thermal power of LIFE waste is initially higher than that of spent LWR fuel. Nevertheless, this higher thermal load can be managed using appropriate engineering features during an interim storage period, and could be accommodated in a Yucca-Mountain-like repository by appropriate 'staging' of the emplacement of waste packages during the operational period of the repository. The planned ventilation rates for Yucca Mountain would be sufficient for LIFE waste to meet the thermal constraints of the repository design. (4) A simple, but arguably conservative, estimate for the dose from a repository containing 63,000 MT of spent LIFE fuel would have similar performance to the currently planned Yucca Mountain Repository. This indicates that a properly designed 'LIFE Repository' would almost certainly meet the proposed Nuclear Regulatory Commission standards for dose to individuals, even though the waste in such a repository would have produced 20-30 times more generated electricity than the reference case for Yucca Mountain. The societal risk/benefit ratio for a LIFE repository would therefore be significantly better than for currently planned repositories for LWR fuel.

42 ENGINEERING↗

Specification for a Program for an Interative Aeroelastic Solution (PIAS)

An engineering and software specification which was written for a computer program to calculate aeroelastic structural loads including the effects of nonlinear aerodynamics is presented. The procedure used in the program for an iterative aeroelastic solution (PIAS) is to alternately execute two computer codes: one to calculate aerodynamic loads for a specific wing shape, and another to calculate the deflected shape caused by this loading. A significant advantage to the design of PIAS is that the initial aerodynamic module can be replaced with others. The leading edge vortex (LEV) program is used as the aerodynamic module in PIAS. This provides the capability to calculate aeroelastic loads, including the effects of a separation induced leading edge vortex. The finite element method available in ATLAS Integrated structural analysis and design system is used to determine the deflected wing shape for the applied aerodynamics and inertia loads. The data management capabilities in ATLAS are used by the execution control monitor (ECM) of PIAS to control the solution process.

Manro, M. E.↗