Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “liquid cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

A neutron tomography study to visualize fluoride salt (FLiNaK) intrusion in nuclear-grade graphite

Manufactured graphite is a preferred material for in-core components of molten salt reactors and fluoride salt-cooled high-temperature reactors, which are in permanent contact with liquid salts. However, owing to the porous nature of nuclear graphite, under certain conditions, molten salts may intrude graphite's pores and affect graphite's properties and functionality. Therefore, a better understanding of molten salt intrusion (distribution across sample cross section and penetration depth) is needed to assess its effects. Here, in this work, we have demonstrated the use of neutron imaging (computed tomography) in the evaluation of salt penetration and distribution of a wide range of graphite grades with diverse microstructures that have been subjected to FLiNaK (LiF–NaF–KF) intrusion at 750 °C and 5 bar pressure for 12 h. Because of the great neutron attenuation contrast from scattering and adsorption between Li (from FLiNaK) and the graphite matrix, we have obtained direct visualization of FLiNaK salt distribution in the salt-impregnated graphites for the first time. Three-dimensional reconstructed images and cross-sectional concentration profiles demonstrate that salt penetration and density distribution are greatly dependent on the microstructural properties of the graphite grade.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Invisible ship tracks show large cloud sensitivity to aerosol

Cloud reflectivity is sensitive to atmospheric aerosol concentrations because aerosols provide the condensation nuclei on which water condenses. Increased aerosol concentrations due to human activity affect droplet number concentration, liquid water and cloud fraction, but these changes are subject to large uncertainties. Ship tracks, long lines of polluted clouds that are visible in satellite images, are one of the main tools for quantifying aerosol–cloud interactions. However, only a small fraction of the clouds polluted by shipping show ship tracks. Here we show that even when no ship tracks are visible in satellite images, aerosol emissions change cloud properties substantially. We develop a new method to quantify the effect of shipping on all clouds, showing a cloud droplet number increase and a more positive liquid water response when there are no visible tracks. We directly detect shipping-induced cloud property changes in the trade cumulus regions of the Atlantic, which are known to display almost no visible tracks. Our results indicate that previous studies of ship tracks were suffering from selection biases by focusing only on visible tracks from satellite imagery. The strong liquid water path response we find translates to a larger aerosol cooling effect on the climate, potentially masking a higher climate sensitivity than observed temperature trends would otherwise suggest.

54 ENVIRONMENTAL SCIENCES↗

Study of the water dynamics near hydrophilic, nanostructured CuO surfaces by quasielastic and inelastic neutron scattering

We have used quasielastic and inelastic neutron scattering to investigate the structure, dynamics, and phase transitions of water interacting with superhydrophilic CuO surfaces that not only possess a strong affinity for water but also a “grass-like” topography that is rough on both micro- and nanoscales. Here, we report quasielastic neutron scattering (QENS) measurements on two samples differing in water content at five temperatures below 280 K. The QENS spectra show water undergoing two different types of diffusive motion near the CuO surfaces: a “slow” translational diffusion occurring on a nanosecond time scale and a faster rotational motion. Further from the surfaces, there is “fast” translational diffusion comparable in rate to that of bulk supercooled water and the rotational motion occurring in the interfacial water. Analysis of the QENS spectra supports wetting of water to the CuO blades as seen in electron microscopy images. In addition, we observe an anomalous temperature dependence of the QENS spectra on cooling from 270 to 230 K with features consistent with a liquid–liquid phase transition. We suggest that the solvent-like properties of the coexisting bulk-like water in our CuO samples are a significant factor in determining the temperature dependence of the interfacial water’s dynamics. Our results are compared with those obtained from two well-studied substrate classes: (1) silicas that contain ordered cylindrical nanopores but have weaker hydrophilicity and (2) nanoparticles of other transition-metal oxides, such as TiO 2 , which share the strong hydrophilicity of our samples but lack their porosity.

36 MATERIALS SCIENCE↗

Overview and status of the Long-Baseline Neutrino Facility Far Site cryogenics system

The Sanford Underground Research Facility (SURF) will host the Far Detector of the Deep Underground Neutrino Experiment (DUNE), an international multi-kiloton Long-Baseline neutrino experiment that will be installed about one and a half kilometers underground in Lead, SD. Detectors will be located inside four cryostats filled with almost 70,000 metric tons of ultrapure liquid argon, with a level of impurities lower than 100 parts per trillion of oxygen equivalent contamination. The cryogenics infrastructure supporting this experiment is provided by the Long-Baseline Neutrino Facility (LBNF). This contribution presents modes of operation, layout, and main features of the LBNF Far Site cryogenic system, which is composed of three subsystems: Infrastructure, Proximity, and Internal cryogenics. The Infrastructure cryogenics supports the needs of the cryostat and Proximity cryogenics. It includes the equipment to receive the argon in liquid phase, vaporize it and transfer it underground as a gas, the nitrogen system (composed of the refrigeration system, liquid nitrogen buffer tanks and liquid and gaseous nitrogen distribution), liquid and gaseous argon distribution and process controls. The Proximity cryogenics receives fluids from the Infrastructure cryogenics and delivers them to the Internal cryogenics at the required temperature, pressure, purity and mass flow rate. It includes the argon condensers, liquid and gaseous argon purification and regeneration systems, nitrogen and argon phase separators, piping, valves, and instrumentation. The Internal cryogenics comprises the liquid and gaseous argon distribution inside the cryostats for the commissioning, cool down, fill, and steady state operations of the cryostats and detectors. An international engineering team is designing these systems and will manufacture, install, commission, and qualify them. This contribution describes the main features, performance, functional requirements, and modes of operation of the LBNF Far Site cryogenics system. It also presents the status of the design, along with present and future needs to support the DUNE experiment.

43 PARTICLE ACCELERATORS↗

Digital Twin Development of FASTR

This work package is focused on creating a digital twin (DT) of the Facility to Alleviate Salt Technology Risks (FASTR) experiment. FASTR is a high-profile facility tasked with maturing molten salt applications such as liquid salt energy storage, concentrated solar power facilities, and molten salt cooling systems supporting other advanced reactor technologies, all of which may be incorporated as components within the Integrated Energy Systems (IES) program. As part of creating a digital twin (DT), verification and validation (V&V) has been performed for the physics-based model, and gaps have been identified. Additionally, a preliminary integration of the FASTR model has been completed with the existing physics-based model of the Thermal Energy Distribution System (TEDS)/Microreactor AGile Non-nuclear Experimental Testbed (MAGNET) facility at Idaho National Laboratory (INL). A Functional Mock-up Unit (FMU) of the physics-based system model and a reduced-order model (ROM) were both used to test for a preliminary hardware in the loop operation when the physical loop was offline. Future tasks could include improving the physics-based model to better match the available experimental data, improving the hardware in the loop integration, and improving the integration with the TEDS model.

14 SOLAR ENERGY↗

Integrated desiccant-based cooling and dehumidification

Integrated systems comprising both i) heat and mass exchange systems and ii) electrolysis stacks are disclosed, together with related methods of use. The disclosed systems cool and/or dehumidify air using two streams of salt solutions as liquid desiccants.

Woods, Jason David↗

Integrated desiccant-based cooling and dehumidification

Integrated systems comprising both i) heat and mass exchange systems and ii) electrolysis stacks are disclosed, together with related methods of use. The disclosed systems cool and/or dehumidify air using two streams of salt solutions as liquid desiccants.

Woods, Jason David↗

Integrated desiccant-based cooling and dehumidification

Integrated systems comprising both i) heat and mass exchange systems and ii) electrolysis stacks are disclosed, together with related methods of use. The disclosed systems cool and/or dehumidify air using two streams of salt solutions as liquid desiccants.

Woods, Jason David↗

Non-Isochronal Behavior of Charge Transport at Liquid–Liquid and Liquid–Glass Transition in Aprotic Ionic Liquids

A reversible, first-order transition separating two liquid phases of a single-component material is a fascinating yet poorly understood phenomenon. Here, we investigate the liquid–liquid transition (LLT) ability of two tetraalkylphosphonium ionic liquids (ILs), [P 666,14 ]Cl and [P 666,14 ][1,2,4-triazolide], using differential scanning calorimetry and dielectric spectroscopy. The latter technique also allowed us to study the LLT at elevated pressure. We found that cooling below 205 K transforms [P 666,14 ]Cl and [P 666,14 ][Trz] from one liquid state (liquid 1) to another (the self-assembled liquid 2), while the latter facilitates the charge transport decoupled from structural dynamics. In contrast to temperature, pressure was found to play an essential role in the self-organization of a liquid 2 phase, resulting in different time scales of charge transport for rapidly and slowly compressed samples. Furthermore, τ σ (P LL ) was found to be much shorter than τ σ (T LL , P=atm), which constitutes the first example of non-isochronal behavior of charge transport at LLT. In turn, dielectric studies through the liquid–glass transition revealed the non-monotonic behavior of τ σ at elevated pressure for [P 666,14 ]Cl, while for [P 666,14 ][Trz] τ σ (P g ) was almost constant. These results highlight the diversity of liquid–liquid transition features within the class of phosphonium ionic liquids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

HIDRA-MAT liquid metal droplet injector for liquid metal applications in HIDRA

A liquid metal droplet injector was explicitly designed for the Hybrid Illinois Device for Research and Applications Material Analysis Test-stand (HIDRA-MAT) at the University of Illinois Urbana-Champaign to prepare liquid metal plasma-facing components (PFCs) for plasma exposure. The design goals were to create a compact, reliable, and robust design that could apply liquid metal droplets in-vacuo to a variety of samples. The injector was designed for liquid metal use, and results discussed pertain to lithium. The injector can produce lithium droplets of consistent size by utilizing programmable piston movement. Here, droplet formation data is presented for four different piston step sizes (0.125 mm, 0.25 mm, 0.5 mm, and 1 mm) at three different nozzle temperatures (185 °C, 230 °C, and 270 °C). Droplets are formed on the injector nozzle tip and a linear shift mechanism vertically translates the droplet to the substrate for application. This design prevents the droplet from inadvertently detaching off the nozzle and falling to the sample. Application of the liquid metal droplet ensures placement consistency on the substrate and helps avoid damage to components in HIDRA-MAT that should not interact with liquid metals. A description of the liquid lithium droplet creation and application results is given and provides additional insight into the cooling and oxidation of lithium droplets under vacuum conditions. A second nozzle was fabricated and demonstrated repeatability in droplet diameter creation having a variance of ±0.14 mm for droplets created from the same number of piston steps. The end-use for the injector on HIDRA-MAT is to apply liquid metals to PFCs and expose them to HIDRA's plasma with subsequent intershot in-vacuo surface analysis in HIDRA-MAT for plasma-material interaction studies.

42 ENGINEERING↗

Assessing parallel path cooling tower performance via artificial neural networks

Real-time monitoring of a research nuclear reactor, a system in which all generated power is dissipated to the environment, can be performed via analysis of the heat rejection from the cooling system. Given an inlet water temperature and flow rate, the reactor power can be well-approximated from the outlet water temperature; however, the instrumentation to measure outlet conditions may not be robust or accurate. If we know how a cooling tower performs from historical data, but cannot measure the outlet temperature, a mathematical representation of the system can be inverted to obtain the outlet water temperature that describes the cooling capacity. Unfortunately, model inversion processes are computationally expensive. To address this, an artificial neural network (ANN) is implemented to assess the performance of a multi-cell cooling tower for a nuclear reactor. This approach leverages the Merkel model to obtain an extensive data set describing performance of the cooling tower cells throughout a wide array of potential operating conditions. The Merkel model is expressed as a function of four parameters: the inlet and outlet water temperatures, inlet air wet bulb temperature, and ratio of liquid-to-gas mass flow rates (L/G), which together provide a non-dimensional number indicative of cooling tower performance, called the Merkel integral. Computing a 4-dimensional data structure that describes finite combinations of the Merkel integral, an inverse model is then generated using an ANN to determine the cell outlet water temperature from the other three model parameters along with the computed Merkel integral. Compared to traditional model inversion methods, the ANN reduces the computational time by approximately 4 orders of magnitude, with effectively no sacrifice to solution accuracy, and could be applied for different cooling towers in the event the performance curve is known. Finally, three use cases of the ANN are then reviewed: (1) determining the cell outlet water temperatures when gas flow at rated conditions (GFRC) is known, (2) performing the prior case without knowledge of the GRFC, and (3) assessing performance differences between the individual tower cells.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Multiphysics Analysis of Li Cooled Divertor Substrate During Loss of Coolant Accident (LOCA)

In the ongoing study of potential designs for liquid metal (LM) plasma-facing components (PFCs), so-called “slow” and “fast” Li flow divertor concepts are under investigation. In the previous studies on design and analysis of the slow Li flow divertor and comparison with the fast Li flow divertor, the magnetohydrodynamics (MHD)/heat transfer effects of the Li flowing inside the substrate as a second coolant were comprehensively investigated under the normal steady-state operation conditions. Here, in the present study, the multiphysics analysis is extended to the unsteady abnormal divertor scenario where the Li layer on top of the substrate does not provide full coverage or even totally disappears for a certain period of time, so that the substrate becomes directly exposed to the incident high plasma heat flux. Such an unwanted event may happen regardless of the concept of the divertor and is worth detailed investigations, typically referred to as a loss of coolant accident (LOCA). To address this situation, a simplified scoping analysis is conducted first in 2-D, and then an integrated 3-D modeling is performed using a time-dependent multiphysics model in COMSOL Multiphysics that integrates LM MHD, heat transfer, and solid mechanics. The main goal is to evaluate conditions under which the major material limits, such as the maximum allowable temperature, stress, and displacement of the substrate, can still be met. It was shown that the maximum time over which the substrate of RAFM steel can retain structural integrity during the LOCA is around 0.2 ∼ 0.3 s. Any divertor concept that utilizes RAFM steel as a substrate material and liquid Li as a second coolant should take such a permitted time into consideration.

divertor↗

Primary solidification of ternary compounds in Al-rich Al–Ce–Mn alloys

Primary solidification of ternary compounds Al 20 Mn 2 Ce and Al 10 Mn 2 Ce were analyzed through the coupling of the thermodynamic modeling and classic nucleation theory. Thermodynamic models of Al 20 Mn 2 Ce and Al 10 Mn 2 Ce were developed using the CALPHAD approach based on first-principles calculated enthalpy of formation and experimental data obtained from this work and the literature. The analysis suggested that despite the larger thermodynamic driving force for nucleation of Al 10 Mn 2 Ce, nucleation is preferred for the Al 20 Mn 2 Ce phase in the highly undercooled liquid due to its smaller interfacial energy. Therefore, manufacturing methods with rapid cooling rates will favor primary solidification of Al 20 Mn 2 Ce for Al-rich Al–Ce–Mn alloys.

36 MATERIALS SCIENCE↗

Assessments of advanced reactor heat supply to high temperature industrial unit operations: Heat Engines and Heat Pumps

In this report, the feasibility of employing Advanced Nuclear Reactors to supply the necessary high-quality heat to Industrial Processes is investigated. As a first step, the most relevant industrial applications that could benefit from this coupling were identified. Four industries including petroleum refining (distillation, catalyst regeneration, hydro-steam cracking), chemical polymers, steel manufacturing (metals annealing/soaking) and cement manufacturing (calcination of limestone and dolomite industries) were considered. An overview of the heat duties, i.e., the temperatures and thermal powers required by representative plants of the different processes, was provided. Secondly, the thermodynamic conditions of the steam produced by representative designs of Advanced Reactor concepts (Liquid Metal Fast Breeder Reactors, Molten Salt Reactors, and High Temperature Gas-cooled Reactors) were summarized. The comparison between the requirements of the industrial processes and the capabilities of the candidate nuclear power plants showed that only a few processes could benefit from the coupling. Although Advanced Reactors operate at higher temperatures than Light Water Reactors, the thermodynamic conditions of the generated steam flow rates are generally not suitable for the selected applications. At the same time, data indicate that most of the processes can be suitably supplied if the temperature of steam is elevated to 900 °C. One possible solution to boost the quality of the steam from the nuclear island involves the use of a heat pump. Based on a technology similar to that found in refrigerators and air conditioners, heat pumps extract heat from a source, elevate its temperature and transfer it to where it is needed. A simple numerical example illustrating the viability of this method is described. Specifically, the energy conversion cycle of a conventional Pressurized Water Reactor was extended to incorporate a compressor to raise the heating value of the steam produced by the reactor. Two reference configurations, i.e., one where the industrial process coupled to the nuclear power plant exhausts saturated liquid and the other where it exhausts saturated steam, were considered. The thermal efficiencies achievable by increasing the heating value of the reactor steam in this way are significantly greater than by direct electric heating.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimental validation of an organic rankine-vapor compression cooling cycle using low GWP refrigerant R1234ze(E)

There is a significant global opportunity to capture and utilize low grade waste heat to reduce fossil fuel consumption, greenhouse gas emissions, and improve energy efficiency across a wide range of industries. In this work, an advanced type of thermally activated cooling system, an organic Rankine-vapor compression cycle (ORVC) with novel heat integration strategies, was designed and tested at a relevant scale for industrial waste heat recovery (300 kW th cooling capacity). The ORVC linked an organic Rankine power cycle and a vapor compression cooling cycle using a turbine and compressor that shared a single shaft. The ORVC test facility absorbed waste heat from a liquid stream at 91 °C to simulate engine coolant in diesel generator sets, rejected heat to a glycol stream at 30 °C, and generated chilled water at 7 °C. A cooling capacity of 264 kW ± 3.5 kW was experimentally validated with a COP of 0.56 ± 0.01 during steady-state operation at the design temperatures. The thermal efficiency, accounting for pump work, of the Rankine cycle was 7.7% ± 0.22% and the COP of the vapor compression cycle was 5.25 ± 0.09. The centrifugal turbo-compressor operated at 31.5 kRPM ± 0.3 kRPM, with a turbine and compressor isentropic efficiencies of 76.7% ± 0.90% and 84.8% ± 0.54%, respectively, with near-perfect power transmission between these components. The pressure drop in the piping and heat exchangers were significantly larger than expected which had a detrimental impact on the performance of the ORVC. In addition, the condenser on the cooling cycle could not deliver the subcooling as specified from the design point modeling. Furthermore, the results from the sensitivity analysis showed that the higher condenser glycol outlet temperature had the largest impact on performance, which is consistent with other analytical models in the literature. When the ORVC simulations were updated with experimental values for isentropic efficiencies of the turbomachinery, the thermal COP was 0.66 which represents an estimate of the predicted performance if test facility limitations are overcome.

30 DIRECT ENERGY CONVERSION↗

Iron-rich microstructure records of high temperature multi-component silicate melt behavior in nuclear fallout

Above-ground nuclear explosions that interact with the surface of the earth entrain materials from the surrounding environment, influencing the resulting physical and chemical evolution of the fireball, which can affect the final chemical phase and mobility of hazardous radionuclides that are dispersed in the environment as fallout particles. The interaction of iron with a nuclear explosion is of specific interest due to the potential for iron to act as a redox buffer and because of the likelihood of significant masses of metals to be present in urban environments. We investigated fallout from a historic surface interacting nuclear explosion conducted on a steel tower and report the discovery of widespread and diverse iron-rich micro-structures preserved within the samples, including crystalline dendrites and micron-scale iron-rich spheres with liquid immiscibility textures. We assert these micro-structures reflect local redox conditions and cooling rates and can inform interpretation of high temperature events, enabling new insights into fireball condensation physics and chemistry when metals from the local environment (i.e. structural steel) are vaporized or entrained. Finally, these observations also significantly expand the availability of silicate immiscibility datasets applicable to rapidly quenched systems such as meteorite impact melt glass.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Investigation of Technologies to Improve Condenser Heat Transfer and Performance in a Relevant Coal-Fired Power Plant

Improvements in thermal power-generating plant performance is correlated directly to societal benefits including lower cost of reduced fuel consumption, resulting in lower cost of electricity for the consumer and reduced carbon emissions to the atmosphere. Warm steam exhausted from low-pressure steam turbines is condensed to liquid water on the exterior of thin-walled metal condenser tubes with cooling water passing through the tube interior. The condensation of steam creates a vacuum that supports turbine rotation and the concurrent generation of electricity. This vacuum is optimized when heat transfer across the wall of condenser tube is maximized. Common hindrances to heat transfer include foulants in cooling water that may form and adhere to the interior of condenser tubes, including mineral scale, microbiological films, and particulate deposition. Flowing cooling water may also include a laminar layer at the interior metal surfaces that travels more slowly than bulk water flow, serving to impede heat transfer. On the tube exterior, condensing steam forms an insulating layer of water that flows down the tube and reduces the effectiveness of cooling. Both the interior and exterior barriers to optimal heat transfer may be alleviated to some extent by surface treatments. On the tube interior, hydrophobic coatings may be applied that can reduced the adherence of foulants and of the laminar flow layer to the tube surface. On the tube exterior, hydrophobic coatings or mechanical treatments can be applied that may result in the termination of droplet growth and the departure of droplets from the surface rather than coalescence into a continuous layer of flowing water. Fourteen surface treatments were applied to condenser tubes in this study, including eight interior coatings and six exterior treatments, five of which were coatings and one a microstructural texture. Heat transfer measurement equipment simulating conditions in the condenser of an operating power plant was used to determine heat transfer coefficients by measuring sufficient flow, temperature, water chemistry and other data. Several of the tubes with interior surface treatments showed improvement in heat transfer coefficients compared with a plain (uncoated) tube, and several of the tubes with exterior surface treatments also showed enhanced heat transfer coefficients.

01 COAL, LIGNITE, AND PEAT↗