Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light pulses”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

The role of catalyst acidity and microstructure on light olefin selectivity in polyethylene deconstruction in short contact time pulse Joule-heated reactors

The growing volume of plastics waste, compounded with a low recycling rate, has led to an alarming amount of plastics ending up in landfills or being incinerated. While pyrolysis offers a route for plastic waste deconstruction, its product distribution is often broad and poorly controlled due to unselective radical chemistry at high temperatures. We recently demonstrated that rapid pulse Joule-heated catalytic cracking over HZSM-5, combined with small fractions of steam, can achieve high selectivity (>80 %) toward C 2 -C 4 olefins, while significantly reducing coking compared to continuous Joule heating. Here, we investigate how acid catalyst properties, such as silica/alumina ratio, zeolite topology, and catalyst porosity, influence light olefin selectivity during polyethylene deconstruction via rapid pulse Joule heating. We demonstrate that silica-to-alumina ratios of ∼30 yield high light olefin selectivity, and small-pore zeolites favor light olefins at the expense of increased coke formation. To mitigate coking, we synthesize HZSM-5 nanosheets and hierarchical zeolites (MFI, FAU, and CHA). Furthermore, these catalysts achieve an ethylene selectivity of approximately 35 %, a twofold increase over prior catalytic pyrolysis. Additionally, co-feeding steam and incorporating hierarchical porosity reduce coke formation and enhance catalyst stability.

Catalytic cracking↗

A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat

CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of 100 Mo. It will operate at ~10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of 100 Mo-enriched Li 2 MoO 4 crystals, facing thin Ge-wafer-based bolometric light detectors. In the CUPID design, the detector structure is novel and needs to be validated. In particular, the CUORE cryostat presents a high level of mechanical vibrations due to the use of pulse tubes and the effect of vibrations on the detector performance must be investigated. In this paper we report the first test of the CUPID-design bolometric light detectors with NTD-Ge sensors in a dilution refrigerator equipped with a pulse tube in an above-ground lab. Light detectors are characterized in terms of sensitivity, energy resolution, pulse time constants, and noise power spectrum. Despite the challenging noisy environment due to pulse-tube-induced vibrations, we demonstrate that all the four tested light detectors comply with the CUPID goal in terms of intrinsic energy resolution of 100 eV RMS baseline noise. Indeed, we have measured 70–90 eV RMS for the four devices, which show an excellent reproducibility. We have also obtained high energy resolutions at the 356 keV line from a 133 Ba source, as good as Ge semiconductor γ detectors in this energy range.

47 OTHER INSTRUMENTATION↗

Spatio-temporally shaped deep UV laser source for ultrabright photocathodes using novel upconversion techniques (Final Report)

The goal of this project was to take a VUV laser system designed by Kapteyn-Murnane Labs (KMLabs)—the Hyperion VUV, and increase its functionality, efficiency, and applicability by further probing the fundamental physics taking place in the system and optimizing the system performance. More specifically, DOE accelerator applications—particularly for XFELs that require low-emittance electron beams, require precisely controlled ultrashort pulses in the deep-UV at 250-260 nm to drive the photocathode electron source. This is conventionally done using an ultrafast infrared laser, with subsequent stages of nonlinear upconversion in solid-state nonlinear-optical crystal media (principally BBO, which is commonly used for UV upconversion). However, maintaining high spatial mode beam quality, as well as precisely controlled temporal profile, has proven a persistent challenge. As a possible alternative to this approach, KMLabs has demonstrated a system that generates vacuum ultraviolet light (VUV) by upconverting pulses from an infrared ultrafast laser in a gas-filled hollow waveguide, driving a process of highly cascaded harmonic generation (HCHG). Because HCHG upconversion is done in a gas, rather than a solid, at high intensity in a guided-wave geometry, it retains an excellent beam spatial profile as well as a large spectral bandwidth that allows for control over the temperal structure of the pulse. A challenge, however, is in energy scaling of this HCHG technique to the ~1-20 μJ pulses required for photocathode applications. To-date, the pulse energies used in published HCHG work are sub-10-nJ. This project proposed to explore ways to generate higher-energy pulses using HCHG, as well as to investigate spectral and temporal shaping of the deep UV pulses by pulse shaping the infrared laser used to seed the process. Although we showed that our approach works for generating light at 259 nm, the total pulse energy achieved seems limited to approximately the same value as past work. However, the techniques we investigated may well have benefits for extending this source to much shorter wavelength output.

43 PARTICLE ACCELERATORS↗

Direct-View Multi-Point Two-Component Interferometric Rayleigh Scattering Velocimeter

This paper describes an instantaneous velocity measurement system based on the Doppler shift of elastically scattered laser light from gas molecules (Rayleigh scattering) relative to an incident laser. The system uses a pulsed laser as the light source, direct-viewing optics to collect the scattered light, an interferometer to analyze spectrally the scattered light mixed with the incident laser light, and a CCD camera to capture the resulting interferogram. The system is capable of simultaneous, spatially (approximately 0.2 mm(exp 3)) and temporally (approximately 40 ns) resolved, multiple point measurements of two orthogonal components of flow velocity in the presence of background scattered light, acoustic noise and vibrations, and flow particulates. Measurements in a large-scale axi-symmetric Mach 1.6 H2-air combustion-heated jet running at a flow sensible enthalpy specific to Mach 5.5 hypersonic flight are performed to demonstrate the technique. The measurements are compared with CFD calculations using a finite-volume discretization of the Favre-averaged Navier-Stokes equations (VULCAN code).

Bivolaru, Daniel↗

Universal structure of propagation-invariant optical pulses

Space–time structuring of light—where spatial and temporal degrees of freedom are deliberately coupled and controlled—is an emerging area of optics that enables novel configurations of electromagnetic fields. Of particular importance for applications are optical pulses whose peak intensity travels at an arbitrary, tunable velocity while maintaining its spatiotemporal profile. Space–time wave packets (STWPs) and the ideal flying focus (FF) are two prominent realizations of these pulses. Here, we show that these realizations share an identical spatiotemporal field structure and that this structure represents a universal solution for constant-velocity, propagation-invariant pulses.

Almeida, R. (ORCID:0000000288435855)↗

Wireless Infrared Data Link

Infrared transmitter and receiver designed for wireless transmission of information on measured physical quantity (for example, temperature) from transducer device to remote-acquisition system. In transmitter, output of transducer amplified and shifted with respect to bias or reference level, then fed to voltage-to-frequency converter to control frequency of repetition of current pulses applied to infrared-light-emitting diode. In receiver, frequency of repetition of pulses converted back into voltage indicative of temperature or other measured quantity. Potential applications include logging data while drilling for oil, transmitting measurements from rotors in machines without using slip rings, remote monitoring of temperatures and pressures in hazardous locations, and remote continuous monitoring of temperatures and blood pressures in medical patients, who thus remain mobile.

Roth, Timothy E.↗

Airborne Laser Polar Nephelometer

A polar nephelometer has been developed at NCAR to measure the angular variation of the intensity of light scattered by air molecules and particles. The system has been designed for airborne measurements using outside air ducted through a 5-cm diameter airflow tube; the sample volume is that which is common to the intersection of a collimated source beam and the detector field of view within the airflow tube. The source is a linearly polarized helium-neon laser beam. The optical system defines a collimated field-of-view (0.5deg half-angle) through a series of diaphragms located behind a I72-mm focal length objective lens. A photomultiplier tube is located immediately behind an aperture in the focal plane of the objective lens. The laser beam is mechanically chopped (on-off) at a rate of 5 Hz; a two-channel pulse counter, synchronized to the laser output, measures the photomultiplier pulse rate with the light beam both on and off. The difference in these measured pulse rates is directly proportional to the intensity of the scattered light from the volume common to the intersection of the laser beam and the detector field-of-view. Measurements can be made at scattering angles from 15deg to 165deg with reference to the direction of propagation of the light beam. Intermediate angles are obtained by selecting the angular increments desired between these extreme angles (any multiple of 0.1deg can be selected for the angular increment; 5deg is used in normal operation). Pulses provided by digital circuits control a stepping motor which sequentially rotates the detector by pre-selected angular increments. The synchronous photon-counting system automatically begins measurement of the scattered-light intensity immediately after the rotation to a new angle has been completed. The instrument has been flown on the NASA Convair 990 airborne laboratory to obtain data on the complex index of refraction of atmospheric aerosols. A particle impaction device is operated simultaneously to collect particles from the same airflow tube used to make the scattered-light measurements. A size distribution function is obtained by analysis of the particles collected by the impaction device. Calculated values of the angular variation of the scattered-light intensity are obtained by applying Mie scattering theory to the observed size distribution function and assuming different values of the complex index of refraction of the particles. The calculated values are then compared with data on the actual variation of the scattered-light intensity obtained with the polar nephelometer. The most probable value of the complex refractive index is that which provides the best fit between the experimental light scattering data and the parameters calculated from the observed size distribution function.

Grams, Gerald W.↗

Determining Extinction Ratio Of A Laser Diode

Improved technique to determine extinction ratio of pulsed laser diode based partly on definition of extinction ratio applicable to nonideal laser pulses. Heretofore, determinations involved assumption of ideal laser pulses, and neglected optical power from background light. Because power fluctuates during real pulse, more realistic to define extinction ratio in terms of energy obtained.

Unger, Glenn L.↗

Coherent frequency combs from electrons colliding with a laser pulse

Highly coherent and powerful light sources capable of generating soft x-ray frequency combs are essential for high precision measurements and rigorous tests of fundamental physics. In this work, we derive the analytical conditions required for the emission of coherent radiation from an electron beam colliding with a laser pulse, modeled as a plane wave. These conditions are applied in a series of numerical simulations, where we show that a soft x-ray frequency comb can be produced if the electrons are regularly-spaced and sufficiently monoenergetic. High quality beams of this kind may be produced in the near future from laser-plasma interactions or linear accelerators. Furthermore, we highlight the advantageous role of employing few-cycle laser pulses in relaxing the stringent monoenergeticity requirements for coherent emission. The conditions derived here can also be used to optimize coherent emission in other frequency ranges, such as the terahertz domain.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical Phase Recovery and Locking in a PPM Laser Communication Link

Free-space optical communication holds great promise for future space missions requiring high data rates. For data communication in deep space, the current architecture employs pulse position modulation (PPM). In this scheme, the light is transmitted and detected as pulses within an array of time slots. While the PPM method is efficient for data transmission, the phase of the laser light is not utilized. The phase coherence of a PPM optical signal has been investigated with the goal of developing a new laser communication and ranging scheme that utilizes optical coherence within the established PPM architecture and photon-counting detection (PCD). Experimental measurements of a PPM modulated optical signal were conducted, and modeling code was developed to generate random PPM signals and simulate spectra via FFT (Fast Fourier Transform) analysis. The experimental results show very good agreement with the simulations and confirm that coherence is preserved despite modulation with high extinction ratios and very low duty cycles. A real-time technique has been developed to recover the phase information through the mixing of a PPM signal with a frequency-shifted local oscillator (LO). This mixed signal is amplified, filtered, and integrated to generate a voltage proportional to the phase of the modulated signal. By choosing an appropriate time constant for integration, one can maintain a phase lock despite long dark times between consecutive pulses with low duty cycle. A proof-of-principle demonstration was first achieved with an RF-based PPM signal and test setup. With the same principle method, an optical carrier within a PPM modulated laser beam could also be tracked and recovered. A reference laser was phase-locked to an independent pulsed laser signal with low-duty-cycle pseudo-random PPM codes. In this way, the drifting carrier frequency in the primary laser source is tracked via its phase change in the mixed beat note, while the corresponding voltage feedback maintains the phase lock between the two laser sources. The novelty and key significance of this work is that the carrier phase information can be harnessed within an optical communication link based on PPM-PCD architecture. This technology development could lead to quantum-limited efficient performance within the communication link itself, as well as enable high-resolution optical tracking capabilities for planetary science and spacecraft navigation.

Aveline, David C.↗

Pulse spreading and range correction analysis for satellite laser ranging

The pulse spreading resulting from light detection and ranging measurements of the range to earth-orbiting satellites is described. An analysis quantifying this pulse spreading and the calculation of corrections to be applied to the lidar range determination of satellites is detailed.

Schwartz, Jon A.↗

Exploring the Light-induced Dynamics in Solvated Metallogrid Complexes with Femtosecond Pulses Across the Electromagnetic Spectrum

Oligonuclear complexes of d 4 -d 7 transition metal ion centers that undergo spin-switching have long been developed for their practical role in molecular electronics. Recently, they also have appeared as promising photochemical reactants demonstrating improved stability. However, the lack of knowledge about their photophysical properties in the solution phase compared to their mononuclear congeners is currently hampering their inclusion into advanced light-driven reactions. In the present study, the ultrafast photoinduced dynamics in a solvated [2x2] iron(II) metallogrid complex are characterized by combining transient optical, infrared absorption and X-ray emission spectroscopic measurements on the femtosecond timescale. The analysis is supported by DFT calculations. The photocycle can be described in terms of intra-site transitions, where the Fe II in the low-spin (LS) state are independently photoexcited. The Franck-Condon state decays via the formation of a vibrationally-hot high-spin (HS) state that displays coherent behavior within a few picoseconds and thermalizes within tens of picosecond to yield a metastable HS state living for several hundreds of nanoseconds. Additionally, systematic comparison with the closely related mononuclear complex [Fe(terpy) 2 ] 2+ reveals that nuclearity has a profound impact on the photoinduced dynamics. Finally, this work provides guidelines for expanding the integration of oligonuclear complexes into new photoconversion schemes that may be triggered by ultrafast spin-switching.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Temperature dependent inverse spin Hall effect in Co/Pt spintronic emitters

In bilayers of ferromagnets and heavy metals, which form the so-called spintronic emitters, the phenomena of ultrafast demagnetization and the inverse spin Hall effect (ISHE) conspire to yield remarkably efficient emission of electric pulses in the THz band. Light-induced demagnetization of the ferromagnet launches a pulse of spin current into the heavy metal, wherein it bifurcates into a radiative charge transient due to the ISHE. The influence of temperature on this combined effect should depend on both the magnetic phase diagram and the microscopic origin of spin Hall conductivity, but its exact dependence remains to be clarified. Here, we experimentally study the temperature dependence of an archetypal spintronic emitter, the Co/Pt bilayer, using electro-optic sampling of the emitted THz pulses in the time domain. The emission amplitude is attenuated with decreasing temperature, consistent with an inverse spin Hall effect in platinum of predominantly intrinsic origin.

Physics↗

dlppi2 (b1)

The Doppler lidar (DL) is an active remote-sensing instrument that provides range- and time-resolved measurements of the line-of-sight component of air velocity (i.e., radial velocity) and attenuated aerosol backscatter. The DL operates in the near-infrared and is sensitive to backscatter from atmospheric aerosol, which are assumed to be ideal tracers of atmospheric wind fields. The DL works by transmitting short pulses of infrared laser light into the atmosphere. Atmospheric aerosols scatter a small fraction of that light energy back to the transceiver, where it is collected and recorded as a time-resolved signal. From the delay between the outgoing pulse and the backscattered signal, the instrument infers the distance to the scattering volume. Coherent detection is used to measure the Doppler frequency shift of the backscatter signal. This is accomplished by mixing the backscatter signal with a reference laser beam (i.e., local oscillator) of known frequency. The onboard signal processor then determines the Doppler frequency shift from the spectrum of the mixed signal. The Doppler frequency shift and thus the radial air velocity is determined from the peak of the Doppler spectrum. The attenuated backscatter is determined from the energy content of the Doppler spectra. The DL provides accurate measurements of radial velocity in regions of the atmosphere where aerosol concentrations are high enough to ensure good signal-to-noise ratio. Thus, valid data are usually limited to the atmospheric boundary layer where aerosol is ubiquitous. Valid measurements can also be obtained in elevated aerosol layers or in optically thin clouds above the boundary layer. Most of the ARM DLs have full upper-hemispheric scanning capability, enabling 3D mapping of turbulent flows in the atmospheric boundary layer. With the scanner pointed vertically, the DL provides height- and time-resolved measurements of vertical velocity.

54 ENVIRONMENTAL SCIENCES↗

An anemometer for measuring velocities on the .25 to 4.25 M/sec range

A vane type anemometer was developed as a secondary standard for the on site calibration of wind velocity sensors. The instrument outputs an electrical pulse for each interruption of a light source by an eight vane fan. The pulse rate is proportional to the fan's angular speed and linearly related to wind velocity over the range 0.25 to 4.27 m/sec.

Carpini, T. D.↗

Spatiotemporal sampling of near-petahertz vortex fields

Measuring the field of visible light with high spatial resolution has been challenging, as many established methods only detect a focus-averaged signal. Here, we introduce a near-field method for optical field sampling that overcomes that limitation by employing the localization of the enhanced near-field of a nanometric needle tip. A probe field perturbs the photoemission from the tip, which is induced by a pump pulse, generating a field-dependent current modulation that can easily be captured with our electronic detection scheme. The approach provides reliable characterization of near-petahertz fields. We show that not only the spiral wavefront of visible femtosecond light pulses carrying orbital angular momentum (OAM) can be resolved but also the field evolution with time in the focal plane. Additionally, our method is polarization sensitive, which makes it applicable to vectorial field reconstruction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thundercloud radio emission from cosmic-ray-shower ionization electrons

The drift of shower ionization electrons in thundercloud fields constitutes a traveling current pulse whose amplitude is modulated by shower development and by the thundercloud field. The radio emission from such a pulse is calculated for a simple modulation model. The response of electric dipole antennas to such pulses is evaluated. To distinguish shower ionization radio pulses from random noise, the use of two receiver bands centered at a common frequency is proposed. It is shown that the ratio of the power in the two bands can be used to distinguish shower ionization radio signals from random noise. For modulated current pulses traveling above the speed of light in a medium, an inverse modulation effect is found. For unmodulated current pulses traveling above the speed of light in a medium, a new class of realizations of the Cerenkov effect is discovered.

Tompkins, D. R., Jr.↗

Measurement Capabilities of Single-Pulse Planar Doppler Velocimetry

Preliminary investigations are described of a method that is capable of measuring instantaneous, 3-D, velocity vectors everywhere in a light sheet generated by a pulsed laser. The technique, here called Planar Doppler Velocimetry (PDV), is a variation of a new concept for velocity measurements that was called Doppler Global Velocimetry (DGV) in its original disclosure. The concept relies on the use of a narrowband laser and measurements of the Doppler shift of scattered light from particles moving with a flow. The Doppler shift is recorded as a variation in transmission through a sharp-edged spectral filter provided by iodine vapor in a cell. Entire fields of velocity can be determined by using a solid-state camera to record the intensity variations throughout the field of view. However, the implementation of DGV has been centered principally on the use of high power, continuous-wave, ion lasers and measurement times that are determined by the 30-ms framing times of standard video cameras. Hence, they provide velocity fields that are averaged in time at least over that period. On the other hand, the PDV concept described in this presentation incorporates a high energy, repetitively pulsed, Nd-YAG laser that is injection-seeded to make it narrowband and then frequency-doubled to provide light at frequencies absorbed by the iodine vapor. The duration of each pulse is less than 10 nanoseconds. When used in combination with nonstandard, scientific quality, solid state cameras, a sequence of images can be obtained that provides instantaneous velocity vectors everywhere in the field of view. The investigations described in this paper include an accurate characterization of the iodine cell spectral behavior and its influence on the PDV measurements, a derivation of the PDV signal analysis requirements, and the unique aspects of the pulsed laser behavior related to this application. In addition, PDV measurements are to be demonstrated using data from a rotating wheel target and from the flow of a subsonic jet. Initially, single optical fiber light collection and photomultiplier detectors will be substituted for solid state cameras. Those results will allow the determination of the fundamental limitations of the PDV technique without the complications of image acquisition and processing. They will then be used to provide an analysis of the measurement capabilities of PDV both in small aerodynamic research wind tunnels and in large wind tunnels designed for production airframe and propulsion testing. Future plans include the implementation of solid state cameras and the development of the required image acquisition and processing software. Eventually, the PDV technique will be applied to an aerodynamic research program related to transonic wing flutter.

McKenzie, Robert L.↗