Quantum simulations of laser-driven fractional quantum Hall system
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
A pulsed laser testing system for rapid screening of single-event latch-up (SEL) in microelectronics with real-time visualization of sensitive nodes via photo-emission is presented. We provide a detailed overview of the system, followed by SEL threshold measurements in an analog-to-digital converter (AD9240). We find that SEL thresholds are comparable to measurements taken with a low-repetition rate, fixed beam system, and demonstrate full-die scanning speeds can be an order of magnitude faster
The addition of hydrogen and oxygen to a hydrocarbon fuel mixture has a significant effect on its sooting tendencies at high pressures. Understanding the mechanism behind the formation of soot is key to proper chemical modeling of fireballs. The objective of this research is to investigate formation rates and soot induction times of intermediary chemicals resulting from energetic material combustion. Three intermediaries, acetylene (C2H2), ethylene (C2H4), and propyne (C3H4-P) are studied. Here, a laser spectroscopy system was utilized to measure soot formation, induction time, and detail the time histories of soot experiments performed using the University of Central Florida high pressure shock tube facility.
Mechanical testing campaigns are required to qualify materials for advanced reactor conditions, yet economical and safety limitations restrict the number of standardized mechanical tests that can be performed. Reducing the size of the sample is one approach to addressing these challenges and to accelerating testing. Previous research has shown that smaller mechanical test samples produce higher yield and ultimate stress values compared to values measured from standard sample sizes: the “smaller is stronger” effect. Specimens used in accelerated material testing campaigns must reflect bulk material performance to enable engineering scale material property measurement. The objective of this research project was to determine if engineering scale mechanical behavior—the yield stress—could be measured with micro-tensile test samples smaller than traditional standard testing geometries. The relationship between yield stress and sample size was explored with two different nuclear-relevant structural materials: Zircaloy-4 and tungsten. Mechanical testing of both metals demonstrated decreasing yield stress values with increasing sample gauge size across three different sizes. Yield stress values from the largest gauge size, fabricated with a femto-second laser ablation system, approach bulk material yield stress values reported in published literature. Preliminary analysis of the tungsten samples indicates the yield stress value depends on the grain characteristics within the gauge section, in addition to the gauge size. Accompanying modeling efforts, including response surface generation and crystal plasticity approaches, further demonstrated that the size of the sample gauge section alone cannot explain the change in yield stress values.
Double-walled containment cells are described as may be used for storage, transport, and examination of a sample held within the cell by use of optical analysis techniques. A double-walled containment cell can include multiple types of windows that can be located as desired on the containment cells and thereby provide for optical access to a sample for multiple optical analysis techniques. Disclosed containment cells can be sized and designed for use with existing optical analysis systems, e.g., laser ablation, X-ray diffraction, spectral analysis (e.g., Raman spectroscopy, infrared spectroscopy, laser-induced breakdown spectroscopy, etc.), imaging analysis, etc.
Tungsten is the leading plasma facing material candidate due to its exceptional properties. Understanding the response to neutron irradiation is crucial for the lifetime evaluation of tungsten. The limited space in nuclear reactors and the high levels of radioactivity of the specimens after irradiation are significant barriers to accurately measuring the mechanical properties after neutron irradiation. Testing of micro tensile specimens is one approach to reduce the total amount of irradiated material needed for a set of mechanical testing experiments. However, micro samples are not necessarily measuring the bulk material properties, as size effects produce higher measured mechanical properties than is observed in engineering size counterparts. Determining the minimal sample size for reliable bulk property measurement, combined with modeling efforts, is essential. We conducted room temperature tensile tests on tungsten micro tensile specimens fabricated with focused ion beam, plasma focused ion beam and femto-second laser ablation system to dimension of 2×2×7?µm³, 7×7×18?µm³, and 80×100×233?µm³ (width×thickness×gauge-length), respectively. Elevated tensile testing was performed up to 475°C on 5×5×18?µm³ specimens fabricated with focused ion beam. The smallest specimens exhibited a high degree of ductility and strength, whereas the largest specimens demonstrated behavior akin to bulk tungsten. To investigate the effects introduced by the micro specimen fabrication processes and to obtain the necessary bulk dislocation density for the crystal plasticity model, we employed X-ray diffraction depth profiling. This measurement was performed using different X-ray sources with varying penetration depths. Finally, the potential and limitations of micro mechanical tests for tungsten will be discussed.
Here, we present the development of a flexible tape-drive target system to generate and control secondary high-intensity laser-plasma sources. Its adjustable design permits the generation of relativistic MeV particles and x rays at high-intensity (i.e., ≥1 × 10 18 W cm —2 ) laser facilities, at high repetition rates (>1 Hz). The compact and robust structure shows good mechanical stability and a high target placement accuracy (<4 μm RMS). Its compact and flexible design allows for mounting in both the horizontal and vertical planes, which makes it practical for use in cluttered laser-plasma experimental setups. The design permits ~170° of access on the laser-driver side and 120° of diagnostic access at the rear. A range of adapted apertures have been designed and tested to be easily implemented to the targetry system. The design and performance testing of the tape-drive system in the context of two experiments performed at the COMET laser facility at the Lawrence Livermore National Laboratory and at the Advanced Lasers and Extreme Photonics (ALEPH) facility at Colorado State University are discussed. Experimental data showing that the designed prototype is also able to both generate and focus high-intensity laser-driven protons at high repetition rates are also presented.
A laser-based manufacturing system is disclosed for fabricating non-planar three-dimensional layers. The system may have a laser for producing a laser beam with a plurality of optical wavelengths. An optically dispersive element may be used for receiving the laser beam and splitting the beam into a plurality of distinct beam components, wherein each beam component has spatially separated optical spectral components. A phase mask may be used which is configured to receive at least one of the beam components emerging from the dispersive element and to create a modified beam. One or more focusing elements may then be used to receive the modified beam emerging from the phase mask and to focus the modified beam into a non-planar light sheet for use in fabricating a part.
The Surveillance, Fabrication, and Off-Site Operations team at Lawrence Livermore National Laboratory is beginning an update to the nuclear material machining lab in Superblock. Plutonium and other nuclear materials tend to accelerate the aging process for equipment and machines that would otherwise be maintainable for long lives. They have their lifespans shortened from deteriorated seals, embrittled polymer components, accelerated corrosion, and damage to electronics from exposure to radioactive materials. The cost of installation of equipment into a glove box (GB) tends to outstrip the cost of the equipment itself. Due to the magnification of cost, the historical approach to equipment installs has been to purchase and install the highest-quality and most robust equipment available to maximize time between failures and updates. To make room for the installation of a new lathe, the inspection GB is being moved to a different location within the machining lab. As part of the overall effort, the equipment within the inspection GB is being revisited. Current measurement capabilities are antiquated and starting to become problematic due to age. Advances in metrology are sought for more comprehensive characterization of scientific samples. This document aims to identify several options for the replacement of current measurement equipment and identify a system for purchase and eventual installation. The intention is not to select the cheapest system, but rather to identify a system that best meets the needs of both the operators and principal investigators (PI). Following the convention of the SYSM-5620 Design Thinking and System Engineering, it was determined that a laser confocal measurement system from Keyence is the most suitable option for our programmatic need. Form factor, capability, and maintainability were considered. Along with stakeholder input, to ensure the best decision for the Nuclear Material Technology Program.
High-energy lasers (HELs) play an important role in both national defense and scientific research. In defense applications, HELs are used for target detection, tracking, and engagement. In research environments, they support studies of extreme physical conditions relevant to fusion energy and plasma science. These systems depend on the amplification of light through stimulated emission of radiation, allowing optical energy to be increased to the levels required for operation. This amplification occurs when light passes through an energized gain medium that receives energy from an external optical or electrical source. To achieve the desired output, laser systems often use multiple amplification stages, including high-gain preamplifiers and lower-gain power or booster amplifiers. At Lawrence Livermore National Laboratory (LLNL) and other national laboratories, many large-aperture laser amplifier systems are aging and rely on system-specific hardware, obsolete technologies, and incomplete documentation. These legacy systems create challenges for maintenance, supportability, and long-term operation. Their lack of standardization also increases the difficulty of sustaining reliable performance over time. As this infrastructure continues to age, the likelihood of unplanned downtime grows, which can negatively affect both national security missions and scientific research programs that depend on dependable HEL capabilities. The purpose of this document is to demonstrate the application of systems engineering fundamentals and design thinking through the development of a laser amplifier case study. The proposed system concept is intended as an academic exercise and not as a finalized engineering design. As a result, the development presented in this document is incomplete and may contain technical assumptions or errors that would require further investigation before any real-world implementation.
This paper focuses on laser-induced breakdown spectroscopy (LIBS) as an off-gas sensor and details a conceptual irradiation experiment to evaluate its performance in an environment that is more realistic of an operational molten salt reactor (MSR). MSRs are a promising advanced nuclear design that use high-temperature liquid salts as the coolant, fuel, or a combination of both. They will generate and subsequently evolve fission products into the reactor headspace during operation. These evolved fission products will necessitate an online off-gas system to treat the reactor cover gas before recycling it to the core. Such a system, especially during the early deployment phase, will benefit from online sensors to inform operators of the treatment system’s performance. Optical spectroscopy is well-suited to fit this task as it can be remotely deployed using fiber-optics and can detect most species at high frequencies. LIBS can detect nearly every element on the Periodic Table, stable or radioactive, making it an ideal candidate. The provided conceptual experiment discusses the facility requirements, salt capsule design, and detailed testing campaigns with corresponding simulated LIBS spectra.
High-power lasers require enormous beam sizes to avoid optics damage; without plasma control of light, future higher-power systems will have prohibitive costs. The laser-induced formation of ionization patterns in gases provides an opportunity to manipulate the spatial and temporal properties of femtosecond to picosecond beams with precise control at high intensity, providing a path towards compact multi-petawatt lasers. In this project, we proposed new concepts of diffractive optics elements relying on ionization-based structures, including a holographic lens and a compression grating. The theoretical characterization of these optical elements was supported by particle-in-cell simulations. Experiments have been carried out to achieve reflective elements (i.e., plasma-based gratings) that demonstrated high robustness and efficiencies on the order of 50%, which validates the feasibility of our new concepts and paves the way for future plasma-based high-power laser systems.
This document outlines measurements made by Idaho National Laboratory (INL) staff at the Berkeley Lab Laser Accelerator (BELLA) Center. Measurements of a mono-energetic Thomson photon beam were made with various INL instruments. The photon beam was generated by a laser-plasma accelerator system. This project is referred to by the name Laser Wake. Key Lawrence Berkeley National Laboratory (LBNL) personnel involved include Liona Fan-Chiang, Cameron Geddes, Anthony Gonsalves, Robert Jacob, Tobias Ostermayr, and Hai-En Tsai.
The National Ignition Facility (NIF) at Lawrence Livermore National Laboratory precisely guides, amplifies, reflects, and focuses 192 powerful laser beams into a target about the size of a pencil eraser in a few billionths of a second, delivering more than 2 million joules of ultraviolet energy and 500 trillion watts of peak power. A crucial goal of the system is to trigger precise implosions of fuel capsules. This is achieved by delivering all 192 beams at user-specified times and locations on the target, minimizing any deviation from the requested performance. Power requirements can vary substantially on each experiment and the facility supports numerous amplifier pumping configurations and their attendant nonlinear effects. To achieve the tight performance required across such a broad array of configurations, constant comparison of measured and requested power delivery are tracked and long-term trends analyzed as a guide to understanding future performance. A very common question asked is given the current state of the laser today – how well would a similar experiment from the past perform today? Additionally, if one were to specify an alternate amplifier configuration using today’s model would and damage limits be exceeded and would there be an increase in performance. The physics model used to make these predictions and equipment protection checks is called the Virtual Beamline (VBL). VBL is used with an incoming desired pulse shape and energy to be delivered on target, and then does an iterative solve to predict the needed injected pulse in the front-end of the system to achieve this result. To effectively guide and predict future NIF experiment performance, laser scientists explore current amplifier configurations and compare them with historical data utilizing a tool called the Reverify Toolbox.
Systems for processing a material by submerging the material in a fluid and directing laser pulses at the fluid and the material for processing the material. An embodiment removes the surface of concrete, brick, or rock or minerals in a relatively gentle, energy-efficient, and controlled manner that also confines the material that is removed.
Systems for processing a material by submerging the material in a fluid and directing laser pulses at the fluid and the material for processing the material. An embodiment removes the surface of concrete, brick, or rock or minerals in a relatively gentle, energy-efficient, and controlled manner that also confines the material that is removed.
Systems for processing a material by submerging the material in a fluid and directing laser pulses at the fluid and the material for processing the material. An embodiment removes the surface of concrete, brick, or rock or minerals in a relatively gentle, energy-efficient, and controlled manner that also confines the material that is removed.
Conventional proteomics measures the averaged signal from mixed cell populations or bulk tissues, leading to the dilution of significant changes in subpopulations of cells that might serve as important biomarkers. Recent developments in bottom-up proteomics have enabled spatial mapping of cellular heterogeneity in tissue microenvironments. However, bottom-up proteomics cannot precisely infer the abundance changes of intact proteins, which are presented as proteoforms. Herein, we described a spatially resolved top-down proteomics (TDP) platform for proteoform identification and quantification directly on thin tissue sections. The spatial TDP platform consisted of a nanoPOTS (nanodroplet Processing in One pot for Trace Samples)-based sample preparation system and an LCM (laser capture microdissection)-based cell isolation system. We improved the nanoPOTS sample preparation by adding benzonase in the extraction buffer to enhance the coverage of nucleus proteins. Using ~200 cultured cells as model samples, the improved approach increased proteoform identifications from 493 to 700; newly identified proteoforms primarily corresponded to nuclear proteins. To demonstrate the spatial TDP platform in tissue samples, we analyzed LCM-isolated tissue voxels from rat brain cortex and hypothalamus regions. We quantified 426 proteoforms by combining identifications from TopPIC and TDPortal with the quantitation from ProMex. Several proteoforms corresponding to the same gene exhibited mixed abundance profiles between two tissue regions, suggesting potential PTM-specific spatial distributions. The spatial TDP workflow has prospects for biomarker discovery at proteoform level from small tissue sections.